At least 703 records · Page 39

Neural Net Safety Monitor Design

The National Aeronautics and Space Administration (NASA) at the Dryden Flight Research Center (DFRC) has been conducting flight-test research using an F-15 aircraft (figure 1). This aircraft has been specially modified to interface a neural net (NN) controller as part of a single-string Airborne Research Test System (ARTS) computer with the existing quad-redundant flight control system (FCC) shown in figure 2. The NN commands are passed to FCC channels 2 and 4 and are cross channel data linked (CCDL) to the other computers as shown. Numerous types of fault-detection monitors exist in the FCC when the NN mode is engaged; these monitors would cause an automatic disengagement of the NN in the event of a triggering fault. Unfortunately, these monitors still may not prevent a possible NN hard-over command from coming through to the control laws. Therefore, an additional and unique safety monitor was designed for a single-string source that allows authority at maximum actuator rates but protects the pilot and structural loads against excessive g-limits in the case of a NN hard-over command input. This additional monitor resides in the FCCs and is executed before the control laws are computed. This presentation describes a floating limiter (FL) concept1 that was developed and successfully test-flown for this program (figure 3). The FL computes the rate of change of the NN commands that are input to the FCC from the ARTS. A window is created with upper and lower boundaries, which is constantly floating and trying to stay centered as the NN command rates are changing. The limiter works by only allowing the window to move at a much slower rate than those of the NN commands. Anywhere within the window, however, full rates are allowed. If a rate persists in one direction, it will eventually hit the boundary and be rate-limited to the floating limiter rate. When this happens, a persistent counter begins and after a limit is reached, a NN disengage command is generated. The tunable metrics for the FL are (1) window size, (2) drift rate, and (3) persistence counter. Ultimate range limits are also included in case the NN command should drift slowly to a limit value that would cause the FL to be defeated. The FL has proven to work as intended. Both high-g transients and excessive structural loads are controlled with NN hard-over commands. This presentation discusses the FL design features and presents test cases. Simulation runs are included to illustrate the dramatic improvement made to the control of NN hard-over effects. A mission control room display from a flight playback is presented to illustrate the neural net fault display representation. The FL is very adaptable to various requirements and is independent of flight condition. It should be considered as a cost-effective safety monitor to control single-string inputs in general.

Larson, Richard R.↗

Implementation of an Adaptive Controller System from Concept to Flight Test

The National Aeronautics and Space Administration (NASA) at the Dryden Flight Research Center (DFRC) has been conducting flight-test research using an F-15 aircraft (figure 1). This aircraft has been specially modified to interface a neural net (NN) controller as part of a single-string Airborne Research Test System (ARTS) computer with the existing quad-redundant flight control system (FCC) shown in figure 2. The NN commands are passed to FCC channels 2 and 4 and are cross channel data linked (CCDL) to the other computers as shown. Numerous types of fault-detection monitors exist in the FCC when the NN mode is engaged; these monitors would cause an automatic disengagement of the NN in the event of a triggering fault. Unfortunately, these monitors still may not prevent a possible NN hard-over command from coming through to the control laws. Therefore, an additional and unique safety monitor was designed for a single-string source that allows authority at maximum actuator rates but protects the pilot and structural loads against excessive g-limits in the case of a NN hard-over command input. This additional monitor resides in the FCCs and is executed before the control laws are computed. This presentation describes a "floating limiter" (FL) concept that was developed and successfully test-flown for this program (figure 3). The FL computes the rate of change of the NN commands that are input to the FCC from the ARTS. A window is created with upper and lower boundaries, which is constantly "floating" and trying to stay centered as the NN command rates are changing. The limiter works by only allowing the window to move at a much slower rate than those of the NN commands. Anywhere within the window, however, full rates are allowed. If a rate persists in one direction, it will eventually "hit" the boundary and be rate-limited to the floating limiter rate. When this happens, a persistent counter begins and after a limit is reached, a NN disengage command is generated. The tunable metrics for the FL are (1) window size, (2) drift rate, and (3) persistence counter. Ultimate range limits are also included in case the NN command should drift slowly to a limit value that would cause the FL to be defeated. The FL has proven to work as intended. Both high-g transients and excessive structural loads are controlled with NN hard-over commands. This presentation discusses the FL design features and presents test cases. Simulation runs are included to illustrate the dramatic improvement made to the control of NN hard-over effects. A mission control room display from a flight playback is presented to illustrate the neural net fault display representation. The FL is very adaptable to various requirements and is independent of flight condition. It should be considered as a cost-effective safety monitor to control single-string inputs in general.

Larson, Richard R.↗

Active multi-mode data analysis to improve fault diagnosis in AHUs

Faults in heating, ventilation and air conditioning systems can lead to increased energy consumption, occupant comfort issues, and reduced equipment lifetime. Commercial fault detection and diagnosis (FDD) tools has been increasingly deployed in U.S. commercial buildings. While they are helping to achieve energy efficiency and operational reliability, there remain gaps in their fault diagnostic capabilities. The diagnostic results often contain multiple distinct candidate root causes (CRCs) or offer no insight into CRCs. This study developed a novel active rule-based multi-mode data analysis method to enhance diagnostic resolution by applying proven rule sets and additional new rules to data from multiple known operational modes. The proposed method was demonstrated using enhanced air handling unit performance assessment rule sets and validated with the simulated data of two air handling units. New metrics, namely, reduced number of CRCs and improvement ratio, were developed to quantify the improvement of fault diagnostic resolution. The validation results showed that the proposed method effectively reduced the number of CRCs in contrast to analyzing data solely for a single mode of operation. It achieved a median improvement ratio of 80% in 19 test cases.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Designing a decentralized fault-tolerant software framework for smart grids and its applications

The vision of the ‘Smart Grid’ anticipates a distributed real-time embedded system that implements various monitoring and control functions. As the reliability of the power grid is critical to modern society, the software supporting the grid must support fault tolerance and resilience of the resulting cyber-physical system. This paper describes the fault-tolerance features of a software framework called Resilient Information Architecture Platform for Smart Grid (RIAPS). The framework supports various mechanisms for fault detection and mitigation and works in concert with the applications that implement the grid-specific functions. The paper discusses the design philosophy for and the implementation of the fault tolerance features and presents an application example to show how it can be used to build highly resilient systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An analysis of redundancy management algorithms for asynchronous fault tolerant control systems

Redundancy management algorithms, commonly referred to as voters, are algorithms used in fault-tolerant control systems to vote on incoming redundant data, isolate bad signals, and output a single good value. In a synchronous environment, this algorithm is a straightforward signal-to-signal comparison with relatively low complexity. The technology of asynchronous control systems, recently realized in the Ultrareliable Fault Tolerant Control System research program at NASA Ames Research Center, requires more complex algorithms for fault detection and signal selection. A variety of algorithms used for this process, a means of testing them, and their basic performance under a simulated environment of the ultrareliable fault-tolerant control system are presented.

Davis, Gloria J.↗

NASA systems autonomy demonstration project: Advanced automation demonstration of Space Station Freedom thermal control system

The NASA Systems Autonomy Demonstration Project (SADP) was initiated in response to Congressional interest in Space station automation technology demonstration. The SADP is a joint cooperative effort between Ames Research Center (ARC) and Johnson Space Center (JSC) to demonstrate advanced automation technology feasibility using the Space Station Freedom Thermal Control System (TCS) test bed. A model-based expert system and its operator interface were developed by knowledge engineers, AI researchers, and human factors researchers at ARC working with the domain experts and system integration engineers at JSC. Its target application is a prototype heat acquisition and transport subsystem of a space station TCS. The demonstration is scheduled to be conducted at JSC in August, 1989. The demonstration will consist of a detailed test of the ability of the Thermal Expert System to conduct real time normal operations (start-up, set point changes, shut-down) and to conduct fault detection, isolation, and recovery (FDIR) on the test article. The FDIR will be conducted by injecting ten component level failures that will manifest themselves as seven different system level faults. Here, the SADP goals, are described as well as the Thermal Control Expert System that has been developed for demonstration.

Dominick, Jeffrey↗

NEXT Single String Integration Tests in Support of the Double Asteroid Redirection Test Mission

A system integration test has been performed utilizing a prototype model NEXT ion thruster, an engineering model power processing unit, and a laboratory model command and data handling system. The objectives of the test were to: a) verify that the integrated system meets performance requirements, b) demonstrate that the integrated system is functional across the anticipated thermal, power processor, and Xe propellant ranges for the DART mission, and to c) evaluate fault detection and operation of the command and data handling system. Measurements made during this test included: thruster performance, PPU input voltages, PPU electrical and thermal telemetry, software states, and fault flags. Additionally, a far-field electrostatic probe diagnostic was used to infer relative changes in the thrust vector across the various propellant flow splits. This manuscript presents the results of these tests, which include integrated ion propulsion system demonstrations of performance, details on the execution of DART flight algorithms, and software fault handling.

Thomas, Robert E.↗

NEXT Single String Integration Tests in Support of the Double Asteroid Redirection Test Mission

A system integration test has been performed utilizing a prototype model NEXT ion thruster, an engineering model power processing unit, and a laboratory model command and data handling system. The objectives of the test were to: a) verify that the integrated system meets performance requirements, b) demonstrate that the integrated system is functional across the anticipated thermal, power processor, and Xe propellant ranges for the DART mission, and to c) evaluate fault detection and operation of the command and data handling system. Measurements made during this test included: thruster performance, PPU input voltages, PPU electrical and thermal telemetry, software states, and fault flags. Additionally, a far-field electrostatic probe diagnostic was used to infer relative changes in the thrust vector across the various propellant flow splits. This manuscript presents the results of these tests, which include integrated ion propulsion system demonstrations of performance, details on the execution of DART flight algorithms, and software fault handling.

Thomas, Robert↗

Digital Twin Enabling Technologies for Online Condition Monitoring of Nuclear Power Plant Components

Online condition monitoring is an area of active research that may enable improved scheduling, maintenance, and safety of nuclear power plant components, reducing unnecessary derate while simultaneously improving operational capacity. Digital twins are one avenue to conduct online condition monitoring and are currently being explored by national laboratories and universities alike. Digital twins for online condition monitoring are, in essence, state concurrent models that emulate a physical process which predicts a parameter and compares it against a measured value. However, digital twins may also provide additional insights by combining and interpreting various sources of information. These insights may be used for preventative maintenance scheduling optimization or early fault detection and are projected to be valuable for meeting requirements under 10 CFR 50.55a. However, digital twin technologies are still under significant development; quantifying model uncertainties, improving unique fault identification, and multimodal sensor fusion are some areas under investigation. Therefore, in this work, we discuss and review the various enabling technologies, in the form of advanced sensors, instrumentation, and modelling methods, that may be used to implement and enhance digital twins for online condition monitoring. A potential use case for pump-motors is presented to demonstrate how these various pieces of enabling digital twin technologies may integrated together for online condition monitoring. Challenges and opportunities associated with the pump-motor digital twin enabling technologies are also identified and discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Digital-Twin-Enabling Technologies for Online Condition Monitoring of Nuclear Power Plant Components

Online condition monitoring is an area of active research that may enable improved scheduling, maintenance, and safety of nuclear power plant components, reducing unnecessary derates while simultaneously improving operational capacity. Digital twins are one avenue to conduct online condition monitoring and are currently being explored by national laboratories and universities alike. Digital twins for online condition monitoring are, in essence, state concurrent models that emulate a physical process which predicts a parameter and compares it against a measured value. However, digital twins may also provide additional insights by combining and interpreting various sources of information. These insights may be used for preventative maintenance scheduling optimization or early fault detection and are projected to be valuable for meeting requirements under 10 CFR 50.55a. However, digital twin technologies are still under significant development; quantifying model uncertainties, improving unique fault identification, and multimodal sensor fusion are some areas under investigation. Therefore, in this work, we discuss and review the various enabling technologies, in the form of advanced sensors, instrumentation, and modelling methods, that may be used to implement and enhance digital twins for online condition monitoring. A potential use case for pump-motors is presented to demonstrate how these various pieces of enabling digital twin technologies may integrated together for online condition monitoring. Challenges and opportunities associated with the pump-motor digital twin enabling technologies are also identified and discussed.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Forming Human-Robot Teams Across Time and Space

NASA pushes telerobotics to distances that span the Solar System. At this scale, time of flight for communication is limited by the speed of light, inducing long time delays, narrow bandwidth and the real risk of data disruption. NASA also supports missions where humans are in direct contact with robots during extravehicular activity (EVA), giving a range of zero to hundreds of millions of miles for NASA s definition of "tele". . Another temporal variable is mission phasing. NASA missions are now being considered that combine early robotic phases with later human arrival, then transition back to robot only operations. Robots can preposition, scout, sample or construct in advance of human teammates, transition to assistant roles when the crew are present, and then become care-takers when the crew returns to Earth. This paper will describe advances in robot safety and command interaction approaches developed to form effective human-robot teams, overcoming challenges of time delay and adapting as the team transitions from robot only to robots and crew. The work is predicated on the idea that when robots are alone in space, they are still part of a human-robot team acting as surrogates for people back on Earth or in other distant locations. Software, interaction modes and control methods will be described that can operate robots in all these conditions. A novel control mode for operating robots across time delay was developed using a graphical simulation on the human side of the communication, allowing a remote supervisor to drive and command a robot in simulation with no time delay, then monitor progress of the actual robot as data returns from the round trip to and from the robot. Since the robot must be responsible for safety out to at least the round trip time period, the authors developed a multi layer safety system able to detect and protect the robot and people in its workspace. This safety system is also running when humans are in direct contact with the robot, so it involves both internal fault detection as well as force sensing for unintended external contacts. The designs for the supervisory command mode and the redundant safety system will be described. Specific implementations were developed and test results will be reported. Experiments were conducted using terrestrial analogs for deep space missions, where time delays were artificially added to emulate the longer distances found in space.

Hambuchen, Kimberly↗

On the Investigation of Phase Fault Classification in Power Grid Signals: A Case Study for Support Vector Machines, Decision Tree and Random Forest

In monitoring the power grid, an ability to differentiate between fault types is essential to ensuring electrical safety. Accordingly, this study introduces a fault detection and classification method by considering different machine learning (ML) and feature extraction (FE) methods combinations. Specifically, the proposed method is established in two classification layers; the first layer determines the fault, and the second layer distinguishes the type of fault. Based on the proposed system model, this study seeks to determine the influential data attributes in a power grid signal using FE methods, including fast Fourier transform, power spectral density (PSD), auto-correlation, and wavelet transform (WT). A cross-comparison of the effectiveness of the Support Vector Machine (SVM), Decision Tree (DT), and Random Forest (RF) is also performed to accomplish the classification layers of the proposed method. The designed algorithm is analyzed under the various combinations of FE and ML methods, and outcomes are presented by considering the trade-off between computational complexity and prediction accuracy. The results reveal that the RF-based ML algorithm shows the most accurate classification performance with PSD, and the most time-saving of the models is the DT WT. Also, SVM emerges superior on a subsequent test of the simulated models on real-world signals.

Galbraith, Kelli↗

Evaluation of HVAC & refrigeration system fault behaviors and impacts: A systematic review

Achieving the goals of green buildings critically depends on the fault-free operation of heating, ventilation and air conditioning and refrigeration (HVAC&R) systems. However, faults frequently occur in these systems, causing a range of negative consequences, including increased energy consumption, diminished operational performance, compromised indoor environmental quality, higher operational costs, and shortened system lifespan. The evaluation of fault behaviors and impacts plays a critical role in revealing fault characteristics and consequently supports many research areas, including the design of the high-performance equipment, development of fault detection and diagnostics (FDD) and robust control approaches, as well as the enhancement of maintenance decision-making activities. This paper systematically reviews 112 research publications that reported the analysis and evaluation of fault behaviors and impacts in HVAC&R systems over the past thirty years. Here, we designed a review approach to address five crucial research questions, namely: 1) the objectives of analysis and evaluation of fault behaviors and impacts, 2) data sources, 3) equipment/system types and fault types, 4) evaluation methods including evaluation measures and associated metrics, and 5) challenges and future directions in the research on evaluating of fault behaviors and impacts. In-depth discussions on these questions help bridge the gap between the evaluation of fault behaviors and impacts and their practical applications, such as the development of high-performance systems, fault models, FDD methods, and maintenance decision-making tools within the HVAC&R FDD domain.

Chen, Yimin [Oak Ridge National Laboratory (ORNL),↗

Condition Monitoring of Wind Turbine Planetary Gearboxes Under Different Operating Conditions

Digitally enhanced services for wind power could reduce Operations and Maintenance (O&M) costs as well as the Levelised Cost Of Energy (LCOE). Therefore, there is a continuous need for advanced monitoring techniques which can exploit the opportunities of Internet of Things (IoT) and Big Data Analytics, revolutionizing the future of the energy sector. The heart of wind turbines is a rather complex epicyclic gearbox. Among others, extremely critical gearbox components which are often responsible for machinery stops are the rolling element bearings. The vibration signatures of bearings are rather weak compared to other components, such as gears, and as a result an extended number of signal processing techniques and tools have been proposed during the last decades, focusing towards accurate, early, and on time bearing fault detection with limited false alarms and missed detections. Envelope Analysis is one of the most important methodologies, where an envelope of the vibration signal is estimated usually after filtering around a frequency band excited by impacts due to the bearing faults. Different tools, such as Kurtogram, have been proposed in order to accurately select the optimum filter parameters (center frequency and bandwidth). Cyclic Spectral Correlation and Cyclic Spectral Coherence, based on Cyclostationary Analysis, have been proved as very powerful tools for condition monitoring. The monitoring techniques seem to have reached a mature level in case a machinery operates under steady speed and load. On the other hand, in case the operating conditions change, it is still unclear whether the change of the monitoring indicators is due to the change of the health of the machinery or due to the change of the operating parameters. Recently, the authors have proposed a new tool called IESFOgram, which is based on Cyclic Spectral Coherence and can automatically select the filtering band. Furthermore, the Cyclic Spectral Coherence is integrated along the selected frequency band leading to an Improved Envelope Spectrum. In this paper, the performance of the tool is evaluated and further extended on cases operating under different speeds and different loads. The effectiveness of the methodology is tested and validated on the National Renewable Energy Laboratory (NREL) wind turbine gearbox vibration condition monitoring benchmarking data set which includes various faults with different levels of diagnostic complexity as well as various speed and load operating conditions.

17 WIND ENERGY↗

What's in a Name? Developing a Standardized Taxonomy for HVAC System Faults

Faults occurring in heating, ventilation and air-conditioning (HVAC) systems have significantly negative impacts on building energy consumption, occupant comfort, and indoor air quality. In the past thirty years, extensive research has been conducted on fault detection and diagnostics (FDD) methods, and there are now dozens of commercially available FDD software tools. Growing adoption of FDD tools has the potential to generate a massive and useful data set on fault characteristics. However, the lack of a unifying taxonomy is a significant barrier to efficient analysis and evaluation of FDD outputs. Therefore, there is a strong need to develop a robust taxonomy which can better represent and interpret FDD output data. This paper documents the development of a unifying taxonomy for HVAC system faults in commercial buildings, with initial focus on air handling units, variable air volume terminal units, and roof top unit systems. The developed fault taxonomy employs both a physical hierarchy of HVAC equipment and a cause-effect relationship model as tools to better understand and support root cause analysis for HVAC faults. A variable air volume terminal unit is used as an example to demonstrate the application of the developed fault taxonomy. The taxonomy has short-term application in a major U.S. study on fault prevalence, and promises longer term benefits to FDD software developers and building operators by creating a foundation for improved approaches to identifying and resolving HVAC faults.

Chen, Yimin↗

Expert systems for automated maintenance of a Mars oxygen production system

A prototype expert system was developed for maintaining autonomous operation of a Mars oxygen production system. Normal operation conditions and failure modes according to certain desired criteria are tested and identified. Several schemes for failure detection and isolation using forward chaining, backward chaining, knowledge-based and rule-based are devised to perform several housekeeping functions. These functions include self-health checkout, an emergency shut down program, fault detection and conventional control activities. An effort was made to derive the dynamic model of the system using Bond-Graph technique in order to develop the model-based failure detection and isolation scheme by estimation method. Finally, computer simulations and experimental results demonstrated the feasibility of the expert system and a preliminary reliability analysis for the oxygen production system is also provided.

Ash, Robert L.↗

Phasor Measurement Unit and Its Application in Modern Power Systems

The introduction of phasor measuring units (PMUs) in power systems significantly improves the possibilities for monitoring and analyzing power system dynamics. Synchronized measurements make it possible to directly measure phase angles between corresponding phasors in different locations within the power system. Improved monitoring and remedial action capabilities allow network operators to utilize the existing power system in a more efficient way. Improved information allows fast and reliable emergency actions, which reduces the need for relatively high transmission margins required by potential power system disturbances. In this chapter, the applications of PMU in modern power systems are presented. Specifically, the topics touched in this chapter include state estimation, voltage and transient stability, oscillation monitoring, event and fault detection, situation awareness, and model validation. A case study using Characteristic Ellipsoid method based on PMU to monitor power system dynamic is presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving EV Charger Resiliency for MW Charging Systems

In this paper, the resiliency of a megawatt-scale EV charging station is investigated. Fault detection and tolerance methodologies are presented, based on monitoring the voltage offsets in DABs and switch-level currents in three-phase inverters, with the goal of maintaining operation at rated power during single faults and at reduced power under multiple fault conditions. To validate the effectiveness of the proposed strategy, simulation results at the rated 1 MW power of the charging station are carried out, followed by controller hardware-in-the-loop (CHIL) experiments on a 250 kW section of the station. The results highlight the feasibility of the integrated fault-tolerant methods for resilient, high-power EV charging infrastructure.

Adib, Aswad [ORNL] (ORCID:000000020997056X)↗