Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Reply to “Comment on ‘Comparative study of ab initio nonradiative recombination rate calculations under different formalisms’ ”

As pointed out by the comments of Wickramaratne et al., there was indeed an algebra error in our original publication [Phys. Rev. B 91, 205315 (2015)] in calculating the 1D model. We have corrected this error, and did a renewed calculation and comparison of the 1D model and other approximated models. The revised comparison provides some insights for the origin of the difference between the full phonon spectrum electron-phonon coupling static formula results and other approximated results, especially for how to evaluate the amplitude of electron-phonon coupling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the estimation of gravitational wave spectrum from cosmic domain walls

We revisit the production of gravitational waves from unstable domain walls analyzing their spectrum by the use of field theoretic lattice simulations with grid size 1024{sup 3}, which is larger than the previous study. We have recognized that there exists an error in the code used in the previous study, and the correction of the error leads to the suppression of the spectrum of gravitational waves at high frequencies. The peak of the spectrum is located at the scale corresponding to the Hubble radius at the time of the decay of domain walls, and its amplitude is consistent with the naive estimation based on the quadrupole formula. Using the numerical results, the magnitude and the peak frequency of gravitational waves at the present time are estimated. It is shown that for some choices of parameters the signal of gravitational waves is strong enough to be probed in the future gravitational wave experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Automated label flows for excited states of correlation functions in lattice gauge theory

Extracting excited states from lattice gauge theory correlation functions can be achieved through $χ^2$ minimization fits or algebraic approaches such as the variational method and Prony's method. Performing any kind of error analysis often leads to overlapping confidence regions of model parameters, even when the spectrum is not particularly dense. To correctly estimate errors, one must beware of mislabeling the states. In this work, we provide an algorithm that we call automated label flows which consistently and systematically identifies a deterministic labeling of states. This is a black-box approach in the sense that it gives a sensible set of labels without user guidance. Further, as an example, we pair one black box method with another, analyzing a lattice correlation function from real data using automated label flows in the context of Prony's method.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Differential spectral responsivity measurement of photovoltaic detectors with a light-emitting-diode-based integrating sphere source

We present an experimental realization of differential spectral responsivity measurement by using a light-emitting diode (LED)-based integrating sphere source. The spectral irradiance responsivity is measured by a Lambertian-like radiation field with a diameter of 40mm at the peak wavelengths of the 35 selectable LEDs covering a range from 280 to 1550nm. The systematic errors and uncertainties due to lock-in detection, spatial irradiance distribution, and reflection from the test detector are experimentally corrected or considered. In addition, we implemented a numerical procedure to correct the error due to the broad spectral bandwidth of the LEDs. The overall uncertainty of the DSR measurement is evaluated to be 2.2% (k=2) for Si detectors. To demonstrate its application, we present the measurement results of two Si photovoltaic detectors at different bias irradiance levels up to 120mW/cm{sup 2}.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility study of real-time planning for stereotactic radiosurgery

Purpose: 3D rotational setup errors in radiotherapy are often ignored by most clinics due to inability to correct or simulate them accurately and efficiently. There are two types of rotation-related problems in a clinical setting. One is to assess the affected dose distribution in real-time if correction is not applied and the other one is to correct the rotational setup errors prior to the initiation of the treatment. Here, the authors present the analytical solutions to both problems. Methods: (1) To assess the real-time dose distribution, eight stereotactic radiosurgery (SRS) cases were used as examples. For each plan, two new sets of beams with different table, gantry, and collimator angles were given in analytical forms as a function of patient rotational errors. The new beams simulate the rotational effects of the patient during the treatment setup. By using one arbitrary set of beams, SRS plans were recomputed with a series of different combinations of patient rotational errors, ranging from (-5 Degree-Sign , -5 Degree-Sign , -5 Degree-Sign ) to (5 Degree-Sign , 5 Degree-Sign , 5 Degree-Sign ) (roll, pitch, and yaw) with an increment of 1 Degree-Sign and compared with those without rotational errors. For each set of rotational errors, its corresponding equivalent beams were computed using the analytical solutions and then used for dose calculation. (2) To correct for the rotational errors, two new sets of table, gantry, and collimator angles were derived analytically to validate the previously published derivation. However, in the derivation, a novel methodology was developed and two sets of table, gantry, and collimator angles were obtained in analytical forms. The solutions provide an alternative approach to rotational error correction by rotating the couch, gantry, and collimator rather than the patient. Results: For demonstration purpose, the above-derived new beams were implemented in a treatment planning system (TPS) to study the rotational effects on the SRS cases. For each case, the authors have generated ten additional plans that accounted for different rotations of the patient. They have found that rotations have an insignificant effect on the minimal, maximum, mean doses, and V{sub 80%} of the planning target volume (PTV) when the rotations were relatively small. This was particularly true for the small and near-spherical targets. They, however, did change V{sub 95%} significantly when the rotations approached 5 Degree-Sign . The theory has been validated with clinical SRS cases and proven to be practical and viable. The preliminary results demonstrate that the rotational effects are patient-specific and depend on several important factors, such as the PTV size, the PTV location, and the beam configuration. The solutions given in this paper are of great potential values in clinical applications. Conclusions: They have derived the analytical solutions to a new set of table, gantry, and collimator angles for a given treatment beam configuration as a function of patient rotational errors. One solution was used to assess the dosimetric effects of an imperfect patient setup and the other one was used to correct for the setup errors without rotating the patient. Compared to the widely adopted method of rotation effect assessment by importing the rotational CT images into TPS, the equivalent beam approach is simple and accurate. The analytical solutions to correcting for rotational setup errors prior to treatment were also derived. Based on the initial clinical investigations, they firmly believe that clinically viable real-time treatment planning and adaptive radiation therapy are feasible with this novel method.

60 APPLIED LIFE SCIENCES↗

New analysis of neutron-lifetime experiments

The experiments on measuring the neutron lifetime have been analyzed. The newest and most exactly measured neutron lifetime [Phys. Lett. B 605, 72 (2005)] (878.5 {+-} 0.8 s) differs from the world average value [Phys. Lett. B 667, 1 (2008)] (885.7 {+-} 0.8 s) by 6.5 standard deviations. In this context, an analysis and Monte Carlo simulation of the experiments [Phys. Lett. B 483, 15 (2000)] and [Phys. Rev. Lett. 63, 593 (1989)] have been performed. Systematic errors of about -6 s are found in both experiments. A table with the results of measuring the neutron lifetime is presented with corrections and additions. The new world average value for the neutron lifetime is found to be 880.0 {+-} 0.9 s.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Errata Sheet for the Closure Report for Corrective Action Unit 538: Spill Sites, Nevada Test Site, Nevada with ROTC-1, Revision 0

This Erratum is being issued to DOE/NV--1185 ROTC-1 for the CAU 538 Closure Report to correct three items. The original ROTC which was issued on November 30, 2011 corrected the Use Restriction for CAS 12-29-06 to remove a coordinate point from the Use Restriction. However, the ROTC contained three errors as follows: 1. The number of digits after the decimal place on the UR form was one while the map displayed two digits after the decimal place. The UR form and map were aligned as part of this Erratum so that only a single digit was shown after the decimal place. 2. On the figure (Figure 1) included with the UR form issued as part of ROTC-1, CAU 538 was incorrectly called out as CAU 583. This error was corrected as part of this Erratum. 3. The coordinates on the UR form were developed from NAD 27 while the coordinate system stated on the form was UTM, Zone 11, NAD 83 meters. The coordinates were corrected on the UR form, developed as part of this Erratum, to reflect the UTM, Zone 11, NAD 83 meters system.

54 ENVIRONMENTAL SCIENCES↗

First principle calculations of effective exchange integrals: Comparison between SR (BS) and MR computational results

First principle calculations of effective exchange integrals (J) in the Heisenberg model for diradical species were performed by both symmetry-adapted (SA) multi-reference (MR) and broken-symmetry (BS) single reference (SR) methods. Mukherjee-type (Mk) state specific (SS) MR coupled-cluster (CC) calculations by the use of natural orbital (NO) references of ROHF, UHF, UDFT and CASSCF solutions were carried out to elucidate J values for di- and poly-radical species. Spin-unrestricted Hartree Fock (UHF) based coupled-cluster (CC) computations were also performed to these species. Comparison between UHF-NO(UNO)-MkMRCC and BS UHF-CC computational results indicated that spin-contamination of UHF-CC solutions still remains at the SD level. In order to eliminate the spin contamination, approximate spin-projection (AP) scheme was applied for UCC, and the AP procedure indeed corrected the error to yield good agreement with MkMRCC in energy. The CC double with spin-unrestricted Brueckner's orbital (UBD) was furthermore employed for these species, showing that spin-contamination involved in UHF solutions is largely suppressed, and therefore AP scheme for UBCCD removed easily the rest of spin-contamination. We also performed spin-unrestricted pure- and hybrid-density functional theory (UDFT) calculations of diradical and polyradical species. Three different computational schemes for total spin angular momentums were examined for the AP correction of the hybrid (H) UDFT. HUDFT calculations followed by AP, HUDFT(AP), yielded the S-T gaps that were qualitatively in good agreement with those of MkMRCCSD, UHF-CC(AP) and UB-CC(AP). Thus a systematic comparison among MkMRCCSD, UCC(AP) UBD(AP) and UDFT(AP) was performed concerning with the first principle calculations of J values in di- and poly-radical species. It was found that BS (AP) methods reproduce MkMRCCSD results, indicating their applicability to large exchange coupled systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement and correction of leaf open times in helical tomotherapy

Purpose: The binary multileaf collimator (MLC) is one of the most important components in helical tomotherapy (HT), as it modulates the dose delivered to the patient. However, methods to ensure MLC quality in HT treatments are lacking. The authors obtained data on the performance of the MLC in treatments administered in their department in order to assess possible delivery errors due to the MLC. Correction methods based on their data are proposed. Methods: Twenty sinograms from treatments delivered using both of the authors HT systems were measured and analyzed by recording the fluence collected by the imaging detector. Planned and actual sinograms were compared using distributions of leaf open time (LOT) errors, as well as differences in fluence reconstructed at each of the 51 projections into which the treatment planning system divides each rotation for optimization purposes. They proposed and applied a method based on individual leaf error correction and the increase in projection time to prevent latency effects when LOT is close to projection time. In order to analyze the dosimetric impact of the corrections, inphantom measurements were made for four corrected treatments. Results: The LOTs measured were consistent with those planned. Most of the mean errors in LOT distributions were within 1 ms with standard deviations of over 4 ms. Reconstructed fluences showed good results, with over 90% of points passing the 3% criterion, except in treatments with a short mean LOT, where the percentage of passing points was as low as 66%. Individual leaf errors were as long as 4 ms in some cases. Corrected sinograms improved error distribution, with standard deviations of over 3 ms and increased percentages of points passing 3% in the fluence per angle analysis, especially in treatments with a short mean LOT and those that were more subject to latency effects. The minimum percentage of points within 3% increased to 86%. In-phantom measurements of the corrected treatments showed that, while treatments affected by latency effects were improved, those affected by individual leaf errors were not. Conclusions: Measurement of MLC performance in real treatments provides the authors with a valuable tool for ensuring the quality of HT delivery. The LOTs of MLC are very accurate in most cases. Sources of error were found and correction methods proposed and applied. The corrections decreased the amount of LOT errors. The dosimetric impact of these corrections should be evaluated more thoroughly using 3D dose distribution analysis.

07 ISOTOPE AND RADIATION SOURCES↗

Symmetry-protected self-correcting quantum memory in three space dimensions

Whether self-correcting quantum memories can exist at nonzero temperature in a physically reasonable setting remains a great open problem. Furthermore, it has recently been argued that symmetry-protected topological (SPT) systems in three space dimensions subject to a strong constraint—that the quantum dynamics respect a 1-form symmetry—realize such a quantum memory. We illustrate how this works in Walker-Wang codes, which provide a specific realization of these desiderata. In this setting we show that it is sufficient for the 1-form symmetry to be enforced on a subvolume of the system. This strongly suggests that the SPT character of the state is not essential. We confirm this by constructing an explicit example with a trivial (paramagnetic) bulk that realizes a self-correcting quantum memory. We therefore show that the enforcement of a 1-form symmetry on a measure-zero subvolume of a three-dimensional system can be sufficient to stabilize a self-correcting quantum memory at nonzero temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Precise method of compensating radiation-induced errors in a hot-cathode-ionization gauge with correcting electrode

To compensate pressure-measurement errors caused by a synchrotron radiation environment, a precise method using a hot-cathode-ionization-gauge head with correcting electrode, was developed and tested in a simulation experiment with excess electrons in the SPring-8 storage ring. This precise method to improve the measurement accuracy, can correctly reduce the pressure-measurement errors caused by electrons originating from the external environment, and originating from the primary gauge filament influenced by spatial conditions of the installed vacuum-gauge head. As the result of the simulation experiment to confirm the performance reducing the errors caused by the external environment, the pressure-measurement error using this method was approximately less than several percent in the pressure range from 10{sup −5} Pa to 10{sup −8} Pa. After the experiment, to confirm the performance reducing the error caused by spatial conditions, an additional experiment was carried out using a sleeve and showed that the improved function was available.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical Errors in Ice Microphysics Parameterizations and their Effects on Simulated Regional Climate

The major characteristics of ice microphysics in Weather Research and Forecasting (WRF) Double-Moment 6-class (WDM6) bulk-type cloud microphysics originate from the diagnosed ice number concentration, which is a function of the cloud-ice mixing ratio. In this study, we correct numerical errors in ice microphysics processes of the WDM6, in which the cloud-ice shape is assumed as single bullets and examine the impact on regional climate simulations. Here, by rederiving the relationships between cloud microphysics characteristics, including the one linking the cloud-ice mixing ratio and number concentration, we remove numerical errors intrinsic to the description of cloud-ice characteristics in the original WDM6 microphysics scheme. The revised WDM6 is tested using a WRF framework for regional climate simulations over the East Asian region. We find that our correction to the WDM6 improves the model’s performance in capturing the observed distribution of the monsoon rain band. A reduction in cloud ice is significant in the revised WDM6, which strengthens the Western North Pacific High. By conducting the additional sensitivity experiment in which the characteristics of cloud-ice shape are revised as the one for the column type, our study also finds out that the impacts of the existing numerical errors on the simulated monsoon is as large as the ones of the changes in cloud-ice shape.

54 ENVIRONMENTAL SCIENCES↗

Visual Sensing and Image Processing for Error Detection in Laser Metal Wire Deposition

Laser metal deposition with wire (LMD-w) involves feeding metal wire through a nozzle and melting the wire with a high-power laser. With efficient process control, comprising sensing, processing and feedback correction of errors, the technology has a potential of changing the course of manufacturing. However, the limitation most often encountered in LMD is the difficulty in controlling the process. Monitoring and control of metal additive manufacturing processes has been mostly researched on powder-based systems, and has not yet been investigated to much extent on the side of metal wire feed arrangements. This work proposes a method for detecting cavities in a deposited layer in the LMD-w process via optical inspection and processing of images obtained from a high-resolution camera. The aim is to develop an effective sensing module which automatically detects discontinuities in each layer before proceeding to subsequent layers, to reduce part porosity and improve inter-layer bond integrity.

Adediran, Adeola↗

Erratum: “Adiabatic matching of particle bunches in a plasma-based accelerator in the presence of ion motion” [Phys. Plasmas 28 , 053102 (2021)]

We would like to correct an error affecting the horizontal scale of panels (c) and (d) of Fig. 4 in Ref. 1. A scale factor of k p was neglected when generating the plots. The correct figure is shown below. Further, the authors would like to thank Yujian Zhao for pointing out this issue. We would also like to correct a typo introduced during the preparation of the proofs and affecting Eq. (25); the correct equation reads. (Formula presented). All the conclusions of the paper are unaffected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Image Guidance During Head-and-Neck Cancer Radiation Therapy: Analysis of Alignment Trends With In-Room Cone-Beam Computed Tomography Scans

Purpose: On-board cone-beam computed tomography (CBCT) is currently available for alignment of patients with head-and-neck cancer before radiotherapy. However, daily CBCT is time intensive and increases the overall radiation dose. We assessed the feasibility of using the average couch shifts from the first several CBCTs to estimate and correct for the presumed systematic setup error. Methods and Materials: 56 patients with head-and-neck cancer who received daily CBCT before intensity-modulated radiation therapy had recorded shift values in the medial-lateral, superior-inferior, and anterior-posterior dimensions. The average displacements in each direction were calculated for each patient based on the first five or 10 CBCT shifts and were presumed to represent the systematic setup error. The residual error after this correction was determined by subtracting the calculated shifts from the shifts obtained using daily CBCT. Results: The magnitude of the average daily residual three-dimensional (3D) error was 4.8 {+-} 1.4 mm, 3.9 {+-} 1.3 mm, and 3.7 {+-} 1.1 mm for uncorrected, five CBCT corrected, and 10 CBCT corrected protocols, respectively. With no image guidance, 40.8% of fractions would have been >5 mm off target. Using the first five CBCT shifts to correct subsequent fractions, this percentage decreased to 19.0% of all fractions delivered and decreased the percentage of patients with average daily 3D errors >5 mm from 35.7% to 14.3% vs. no image guidance. Using an average of the first 10 CBCT shifts did not significantly improve this outcome. Conclusions: Using the first five CBCT shift measurements as an estimation of the systematic setup error improves daily setup accuracy for a subset of patients with head-and-neck cancer receiving intensity-modulated radiation therapy and primarily benefited those with large 3D correction vectors (>5 mm). Daily CBCT is still necessary until methods are developed that more accurately determine which patients may benefit from alternative imaging strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fabrication-conscious neural network based inverse design of single-material variable-index multilayer films

Multilayer films with continuously varying indices for each layer have attracted great deal of attention due to their superior optical, mechanical, and thermal properties. However, difficulties in fabrication have limited their application and study in scientific literature compared to multilayer films with fixed index layers. In this work we propose a neural network based inverse design technique enabled by a differentiable analytical solver for realistic design and fabrication of single material variable-index multilayer films. This approach generates multilayer films with excellent performance under ideal conditions. We furthermore address the issue of how to translate these ideal designs into practical useful devices which will naturally suffer from growth imperfections. By integrating simulated systematic and random errors just as a deposition tool would into the optimization process, we demonstrated that the same neural network that produced the ideal device can be retrained to produce designs compensating for systematic deposition errors. Furthermore, the proposed approach corrects for systematic errors even in the presence of random fabrication imperfections. The results outlined in this paper provide a practical and experimentally viable approach for the design of single material multilayer film stacks for an extremely wide variety of practical applications with high performance.

36 MATERIALS SCIENCE↗