Electric-field level-crossing spectroscopy.
Differential Stark effect in second excited state of alkali metal atoms described, using electric field level crossing spectroscopy
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Differential Stark effect in second excited state of alkali metal atoms described, using electric field level crossing spectroscopy
In this study, a multi-proxy approach combining {sup 29}Si, {sup 27}Al and {sup 1}H MAS-NMR, FEG-EPMA, XANES at the Cu K-edge and XRD analytics with hydrochemical tools such as ICP-OES analyses, oxygen-isotope signatures, and thermodynamic modelling was applied to K-silicate-activated metakaolin specimens - with and without CuSO{sub 4}·5H{sub 2}O addition - exposed to sulfuric acid at pH = 2 for 35 days. The results revealed a multistage deterioration mechanism governed by (i) acid diffusion, (ii) leaching of K-A-S-H, (iii) microstructural damage related to precipitation of expansive (K,Ca,Al)-sulfate-hydrate phases (iv) complete dissolution of the K-A-S-H framework, (v) and formation of silica gel in the outermost corroded regions. Copper ions were mainly located in layered spertiniite-chrysocolla-like phases in the as-cured materials. The results demonstrate an overall negative effect of Cu addition on chemical material durability, implying that the reported higher durability of Cu-doped AAM in biocorrosion environments can be best explained by bacteriostatic effects.
TES V5 CH4 captures latitudinal gradients, regional variability and interannual variation in the free troposphere. V5 joint retrievals offer improved sensitivity to lower troposphere. Time series extends from 2004 to present. V5 reprocessing in progress. Upper tropospheric bias. Mitigated by N2O correction. Appears largely spatially uniform, so can be corrected. How to relate free-tropospheric values to surface emissions.
Structural materials used in nuclear reactor environments are subjected to coupled extremes such as high temperature, irradiation, and corrosion which act in concert to degrade their functional performance. Connecting alloy microstructure such as grain boundaries, and accumulating point defects with corrosion attack and pore morphology is critical to understanding underlying mechanisms. We uncover the compositional variations and morphology at multiple length scales in corrosion-damaged Ni-Cr alloy after exposure to oxidants in molten fluoride salts. A complex network of dense corrosion pores is detected by surface-level SEM observations. The corrosion pores take on a 1-dimensional morphology and are enriched with Ni and depleted of Cr 1–5 µm from the pore surface. STEM-EDS and 4D-STEM strain maps acquired simultaneously highlight the local variations in composition and structure of a ≤ 200 nm Cr-rich layer identified from a cross-section taken at the bottom of an isolated corrosion pore between the Ni-Cr alloy matrix and the embedded salt. However, the absence of an observed interface between the Ni-Cr alloy matrix and the FCC-structured Cr-rich layer suggests that Cr plating from the salt did not transpire. These findings support a proposed Cr lattice diffusion mechanism rather than Cr-precipitation from the salt to accommodate temperature transient conditions during sample cooling. Through the development of a 1D phase field model, these results are rationalized by formation energies for the Ni- and Cr-oxidation into the molten salt. This study reveals the locally altered microstructure caused by high temperature corrosion in non-steady-state molten salt nuclear reactor environments.
Bayesian inference applied to x-ray spectroscopy data analysis enables uncertainty quantification necessary to rigorously test theoretical models. However, when comparing to data, detailed atomic physics and radiation transfer calculations of x-ray emission from non-uniform plasma conditions are typically too slow to be performed in line with statistical sampling methods, such as Markov Chain Monte Carlo sampling. Furthermore, differences in transition energies and x-ray opacities often make direct comparisons between simulated and measured spectra unreliable. Here, we present a spectral decomposition method that allows for corrections to line positions and bound–bound opacities to best fit experimental data, with the goal of providing quantitative feedback to improve the underlying theoretical models and guide future experiments. In this work, we use a neural network (NN) surrogate model to replace spectral calculations of isobaric hot-spots created in Kr-doped implosions at the National Ignition Facility. The NN was trained on calculations of x-ray spectra using an isobaric hot-spot model post-processed with Cretin, a multi-species atomic kinetics and radiation code. The speedup provided by the NN model to generate x-ray emission spectra enables statistical analysis of parameterized models with sufficient detail to accurately represent the physical system and extract the plasma parameters of interest.
A calculation of the A2 sigma --> X2 pi (0, 0) band emission rate factors and line center absorption cross sections of OH applicable to its measurement using solar resonant fluorescence in the terrestrial atmosphere is presented in this paper. The most accurate available line parameters have been used. Special consideration has been given to the solar input flux because of its highly structured Fraunhofer spectrum. The calculation for the OH atmospheric emission rate factor in the solar resonant fluorescent case is described in detail with examples and intermediate results. Results of this calculation of OH emission rate factors for individual rotational lines are on average 30% lower than the values obtained in an earlier work.
The Perseverance rover (Mars 2020) mission, the first step in NASA’s Mars Sample Return (MSR) program, will select samples for caching based on their potential to improve understanding Mars’ astrobiological, geological, geochemical, and climatic evolution. Geochronologic analyses will be among the key measurements planned for returned samples. Assessing a sample’s shock history will be critical because shock metamorphism could influence apparent sample age. Shock effects in one Mars-relevant mineral class, plagioclase feldspar, have been well- documented using various spectroscopy techniques (thermal infrared reflectance, emission, and transmission spectroscopy, Raman, and luminescence). A subset of these data will be obtained with the SuperCam and SHERLOC (Scanning Habitable Environments with Raman & Luminescence for Organics & Chemicals) instruments onboard Perseverance to inform caching decisions for MSR. Here, we review shock indicators in plagioclase feldspar as revealed in Raman, luminescence, and IR spectroscopy lab data, with an emphasis on Raman spectroscopy. We consider how this information may inform caching decisions for selecting optimal samples for geochronology measurements. We then identify challenges and make recommendations for both in situ measurements performed with SuperCam and SHERLOC and for supporting lab studies to enhance the success of geochronologic analyses after return to Earth.
The conceptual design and structural analysis for the Spectroscopy of the Atmosphere using Far Infrared Emission (SAFIRE) Instrument are provided. SAFIRE, which is an international effort, is proposed for the Earth Observing Systems (EOS) program for atmospheric ozone studies. A concept was developed which meets mission requirements and is the product of numerous parametric studies and design/analysis iterations. Stiffness, thermal stability, and weight constraints led to a graphite/epoxy composite design for the optical bench and supporting struts. The structural configuration was determined by considering various mounting arrangements of the optical, cryo, and electronic components. Quasi-static, thermal, modal, and dynamic response analyses were performed, and the results are presented for the selected configuration.
We report on experiments investigating heat transport in laser-generated plasmas using directly driven chromium spheres. The spheres are fielded at the OMEGA laser facility and are driven with laser intensities of 5×10 14 Wcm −2 . Plasma conditions in the corona and scattered light are measured experimentally and compared against predictions from two-dimensional (2D) radiation-hydrodynamic simulations using different heat transport models. Spectroscopic analysis of x-ray self-emission is used as an additional diagnostic. X-ray emission is integrated over a large region of the plasma, probing regions that are not observed by localized optical Thomson scattering. In particular, x-ray emission peaks near the plasma critical density, so emission from optically thin lines provides information on plasma conditions where nonlocal transport is most likely to be significant. Three common heat transport models are considered: local transport with flux limiters f = 0.15 and f = 0.03, and the nonlocal Schurtz–Nicolai–Busquet (SNB) model. Consistent with previous work, both the high-flux (f = 0.15) and SNB models show good agreement with experimentally measured plasma conditions in the corona despite overpredicting laser absorption, whereas the low-flux (f = 0.03) model fails to match any experimental data. Conditions inferred from x-ray self-emission line ratios support this conclusion during the period of laser peak power, although synthetic spectra for all models fail to match the experiment during the transient portions of the pulse. For these reasons, the low-flux model is again rejected.
We report isotopic shifts and hyperfine structures of selected U transitions employing tunable spectroscopy viz: laser-induced fluorescence and laser absorption spectroscopy of laser ablation plumes. The laser-produced plasmas were produced during ns laser ablation on a natural U metal which contains 0.7% 235U. Our results show that isotopic shifts between 238U and 235U are entangled with hyperfine structures of 235U. The isotopic ratio obtained using laser-induced fluorescence is affected by optical saturation effect. Time-resolved laser absorption spectroscopy is carried out for evaluating the optical absorption and estimating the hyperfine constants.
The recent detection of a neutron star merger by the LIGO collaboration has renewed interest in laboratory studies of r-process elements. Accurate modeling and interpretation of the electromagnetic transients following the mergers requires computationally expensive calculations of both the structure and opacity of all trans-iron elements. To date, the necessary atomic data to benchmark structure codes are incomplete or, in some cases, absent entirely. Within the available laboratory studies, the literature on Au i and Au ii provides incomplete reports of the emission lines and level structures. We present a new study of Au i and Au ii lines and levels by exposing a solid gold target to plasma in the Compact Toroidal Hybrid (CTH) experiment at Auburn University. A wavelength range from 187 to 800 nm was studied. In Au i, 86 lines are observed, 43 of which are unreported in the literature, and the energies of 18 $5{d}^{9}6s6p$ levels and 16 of the 18 known $5{d}^{9}6s6d$ levels are corroborated by a least-squares level energy optimization. In Au ii, 76 emission lines are observed, and 51 of the lines are unreported in the literature. For both Au i and Au ii, the new lines predominantly originate from the most energetic of the known levels, and over half of the new Au ii lines have wavelengths longer than 300 nm. For the estimated electron parameters of CTH plasmas at the gold target (ne ~ 10 12 cm -3 , T e ~ 10 eV), two-electron transitions are similar in intensity to LS-allowed one-electron transitions.
A new coherence imaging spectroscopy (CIS) diagnostic optimized to measure the C 2+ impurity ion temperature T i spatial distribution in the divertor plasma of the W7-X stellarator is designed, tested, and validated. Using CIS to obtain T i in the edge of magnetically confined plasmas has historically been challenging because Doppler broadening and Zeeman splitting have comparable effects on the shape of spectral emission lines. To distinguish between these two mechanisms, a novel approach to birefringent crystal design is employed to minimize the diagnostic’s sensitivity to Zeeman splitting. The recently developed pixelated multi-delay CIS approach is also used to obtain four times as much spectral information as traditional CIS approaches. The T i -optimized CIS diagnostic is validated in a long-pulse W7-X plasma by comparison with a high-resolution spectrometer whose sightlines overlap with the CIS field of view. The CIS and spectrometer T i profiles have the same shape and agree to within 10% on average and 25% in the worst case. Images of the T i distribution near the divertor show toroidally elongated bands aligned with the magnetic field, with T i ranging between 10 and 40 eV.
MeV-range ions generated in inertial confinement fusion (ICF) and high-energy-density physics experiments carry a wealth of information, including fusion reaction yield, rate, and spatial emission profile; implosion areal density; electron temperature and mix; and electric and magnetic fields. Here, the principles of how this information is obtained from data and the charged particle diagnostic suite currently available at the major US ICF facilities for making the measurements are reviewed. Time-integrating instruments using image plate, radiochromic film, and/or CR-39 detectors in different configurations for ion counting, spectroscopy, or emission profile measurements are described, along with time-resolving detectors using chemical vapor deposited diamonds coupled to oscilloscopes or scintillators coupled to streak cameras for measuring the timing of ion emission. A brief description of charged-particle radiography setups for probing subject plasma experiments is also given. The goal of the paper is to provide the reader with a broad overview of available capabilities, with reference to resources where more detailed information can be found.
Detection of protium, deuterium and tritium using ultrafast LIBS with rapid, and standoff capability in addition to no sample preparation requirement which are crucial to nuclear nonproliferation, safeguards, and security
The conditions in laser-produced plasmas are frequently determined with x-ray spectroscopy by comparing calculated to measured spectra. Line spectra from K-shell transitions of low- to mid-atomic number elements are most often used since the important physical processes are well understood and reliable spectra can be readily measured and calculated. Radiation transfer effects due to large optical depths of strong lines can influence the spectra. In this work, the effects of radiation transfer on the emission spectra of short-laser pulse-heated targets are studied. The possible errors made in inferring electron temperature by not including radiation transfer are quantified. The inclusion of radiative transfer in spectral calculations improves the accuracy of typical temperature diagnostics and allows the use of strong lines for diagnostics.
BEEM spectroscopy has been performed at room temperature and at 77K on Au/Si(111) structures. Au thickness was varied in the range 75-300U At 77K a direct signature of parallel momentum conservation is observed in the BEEM spectra of samples with thick Au layers.
The Early Release Observations (EROs) of JWST beautifully demonstrate the promise of JWST in characterizing the universe at Cosmic Dawn. We analyze the Near Infrared Spectrograph ERO spectra of three z ~ 8 galaxies to determine their metallicities, gas temperatures, and ionization. These galaxies offer the first opportunity to understand the physical properties of Epoch-of-Reionization galaxies through detailed rest-optical emission-line spectroscopy. We show that these objects have metal abundances $12+\mathrm{log}[{\rm{O}}/{\rm{H}}]\,\approx$ 6.9–8.3, based on both the T e method and on a recent calibration of the R 23 metallicity indicator. Since the spectra are some of the earliest science data from JWST, we compare several line ratios with values expected from robust physics, to validate our measurement procedures. We compare the abundances and emission-line ratios to a nearby sample of Green Pea galaxies—a population of nearby emission-line galaxies whose UV properties resemble Epoch-of-Reionization galaxies, and which often have large Lyman continuum escape fractions. The JWST data show striking further similarities between these high-redshift galaxies and nearby Green Peas. The z ~ 8 galaxies span the metallicity range covered by Green Peas. They also show the compact morphology that is typical of emission-line-dominated galaxies at all redshifts. Based on these similarities with Green Peas, it is likely that these are the first rest-optical spectra of galaxies that are actively driving cosmological reionization.
Nuclear security is one of the defining challenges of our time. Nuclear threats range from deliberate dispersal of radioactive material to contaminate the vital infrastructure to diversion and smuggling of special nuclear material for clandestine nuclear programs and nuclear terrorism, respectively. There is an associated need to develop and sustain the nuclear forensics capabilities, which requires the understanding of complex processes that occur in plasmas of nuclear materials. The area of nuclear safety has seen a resurgence of public interest, and there is a concomitant need to safely store used nuclear fuel and detect structural material failure in nuclear power systems, especially in innovative reactor designs envisioned for future adoption. Laser-produced plasmas are complicated extreme environments that can generate intense and rich, highly specific signatures of nuclear and radiological materials, which can then be explored in a wide range of applications. They include interdiction and rapid detection of nuclear materials, including their isotopic composition, detection over long distances, laboratory simulation of weapons effects, monitoring the condition of structural materials in dry cask storage containers, and novel instrumentation for nuclear power systems. We present a compilation of recent representative examples of the application of laser spectroscopy, and laser-induced breakdown spectroscopy in particular, to nuclear safety and security problems. A case is made that spectroscopic techniques based on laser-produced plasmas offer complementary, and sometimes unique, capabilities that motivate the continued exploration of their efficient production and understanding of the signatures they produce