Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronics analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Validation of Atmosphere/Ionosphere Signals Associated with Major Earthquakes by Multi-Instrument Space-Borne and Ground Observations

The latest catastrophic earthquake in Japan (March 2011) has renewed interest in the important question of the existence of pre-earthquake anomalous signals related to strong earthquakes. Recent studies have shown that there were precursory atmospheric/ionospheric signals observed in space associated with major earthquakes. The critical question, still widely debated in the scientific community, is whether such ionospheric/atmospheric signals systematically precede large earthquakes. To address this problem we have started to investigate anomalous ionospheric / atmospheric signals occurring prior to large earthquakes. We are studying the Earth's atmospheric electromagnetic environment by developing a multisensor model for monitoring the signals related to active tectonic faulting and earthquake processes. The integrated satellite and terrestrial framework (ISTF) is our method for validation and is based on a joint analysis of several physical and environmental parameters (thermal infrared radiation, electron concentration in the ionosphere, lineament analysis, radon/ion activities, air temperature and seismicity) that were found to be associated with earthquakes. A physical link between these parameters and earthquake processes has been provided by the recent version of Lithosphere-Atmosphere-Ionosphere Coupling (LAIC) model. Our experimental measurements have supported the new theoretical estimates of LAIC hypothesis for an increase in the surface latent heat flux, integrated variability of outgoing long wave radiation (OLR) and anomalous variations of the total electron content (TEC) registered over the epicenters. Some of the major earthquakes are accompanied by an intensification of gas migration to the surface, thermodynamic and hydrodynamic processes of transformation of latent heat into thermal energy and with vertical transport of charged aerosols in the lower atmosphere. These processes lead to the generation of external electric currents in specific regions of the atmosphere and the modifications, by dc electric fields, in the ionosphere-atmosphere electric circuit. We retrospectively analyzed temporal and spatial variations of four different physical parameters (gas/radon counting rate, lineaments change, long-wave radiation transitions and ionospheric electron density/plasma variations) characterizing the state of the lithosphere/atmosphere coupling several days before the onset of the earthquakes. Validation processes consist in two phases: A. Case studies for seven recent major earthquakes: Japan (M9.0, 2011), China (M7.9, 2008), Italy (M6.3, 2009), Samoa (M7, 2009), Haiti (M7.0, 2010) and, Chile (M8.8, 2010) and B. A continuous retrospective analysis was preformed over two different regions with high seismicity- Taiwan and Japan for 2003-2009. Satellite, ground surface, and troposphere data were obtained from Terra/ASTER, Aqua/AIRS, POES and ionospheric variations from DEMETER and COSMIC-I data. Radon and GPS/TEC were obtaining from monitoring sites in Taiwan, Japan and Italy and from global ionosphere maps (GIM) respectively. Our analysis of ground and satellite data during the occurrence of 7 global earthquakes has shown the presence of anomalies in the atmosphere. Our results for Tohoku M9.0 earthquake show that on March 7th, 2011 (4 days before the main shock and 1 day before the M7.2 foreshock of March 8, 2011) a rapid increase of emitted infrared radiation was observed by the satellite data and an anomaly was developed near the epicenter. The GPS/TEC data indicate an increase and variation in electron density reaching a maximum value on March 8. From March 3 to 11 a large increase in electron concentration was recorded at all four Japanese ground-based ionosondes, which returned to normal after the main earthquake. Similar approach for analyzing atmospheric and ionospheric parameters has been applied for China (M7.9, 2008), Italy (M6.3, 2009), Samoa (M7, 2009), Haiti (M7.0, 2010) and Chile (M8.8, 2010) eahquakes. Results have revealed the presence of related variations of these parameters implying their connection with the earthquake process. The second phase (B) of this validation included 102 major earthquakes (M>5.9) in Taiwan and Japan. We have found anomalous behavior before all of these events with no false negatives. False alarm ratio for false positives is less then 10% and has been calculated for the same month of the earthquake occurrence for the entire period of analysis (2003-2009). The commonalities for detecting atmospheric/ionospheric anomalies are: i.) Regularly appearance over regions of maximum stress (i.e., along plate boundaries); ii.) Anomaly existence over land and sea; and iii) association with M>5.9 earthquakes not deeper than 100km. Due to their long duration over the same region these anomalies are not consistent with a meteorological origin. Our initial results from the ISTF validation of multi-instrument space-borne and ground observations show a systematic appearance of atmospheric anomalies near the epicentral area, one to seven (average) days prior to the largest earthquakes, and suggest that it could be explained by a coupling process between the observed physical parameters and the pre-earthquake preparation processes.

Ouzounov, Dimitar↗

A study of power conditioning and power distribution and components

A comprehensive simulation and analysis performed on the operation of the regulator part of the Charger/Battery/Regulator Module (CBRM) are detailed. The CBRM is utilized as an integral component of the Skylab/Apollo Telescope Mount (ATM) electrical power system and contains a switching mode electronic regulator. Implementing circuit analysis techniques, pertinent voltages and currents are calculated; these, in turn, are incorporated into the regulator system study. Investigation of the turn-on and turn-off times associated with the switching circuitry is performed and an examination is made on these calculations. A simulation model computer program is utilized to generate graphs that relate various CBRM parameters to one another.

Horton, H. M.↗

Coordinated Microstructural and Isotopic Characterization of Diamond Inclusions within the Kenna Ureilite

Introduction: The origin of diamonds in ureilitic meteorites, a major family of ultramafic achondrites, has long been debated, with various formation mechanisms inferred, including: 1) shock conversion of preexisting graphite due to a hypervelocity impact on the ureilite parent body [e.g., 1]; 2) vapor deposition during condensation of the solar nebula [e.g., 2]; or 3) static transformation in the mantle of a large planetesimal (>1000 km in diameter) [e.g., 3]. The Kenna ureilite is a 10.9 kg stone that was found in Kansas in 1972 and is dominantly composed of olivine and pigeonite (68% and 22% modal abundance, respectively), together with minor metal and carbon-rich regions. Within the carbon-rich domains researchers have identified microdiamonds up to ~10 µm in size [4]. Methods: Due to the proximity of the extremely hard microdiamonds with soft graphite and moderately hard silicates, achieving an appropriately flat surface for electron backscatter diffraction (EBSD) analysis has proven challenging. We have, therefore, employed a Hitachi ArBlade 5000 broad beam Ar ion milling system to prepare a sample with an adequately uniform surface flatness across the various minerals. The ion milling dramatically im-proved indexing of the EBSD patterns and facilitated high-resolution microstructural analysis of the carbon-rich domains. After microstructural EBSD analyses using an Oxford Symmetry detector we collected coordinated hy-perspectral cathodoluminescence (CL) analyses using a Gatan Monarc system mounted on a JEOL 7900F field emission (FE) scanning electron microscope at NASA Johnson Space Center. A focused ion beam (FIB) foil was extracted from a region of interest and analyzed using a JEOL 2500 FE scanning transmission electron microscope (STEM). In situ carbon and nitrogen isotopic analyses were collected from diamond-bearing domains using a Cameca NanoSIMS 50L at NASA JSC. Results: The carbon rich regions occur as tabular domains between polygonal olivine and pigeonite, and are composed of aggregates of micrometer-scale diamond with intermediate graphite, oxides and metal grains. Within the microdiamonds, {111} twins are abundant, many of which form ragged lamellae consistent with mechanical twinning. The microdiamond assemblages appear to pseudomorph tabular graphite habits, which together with the abundant deformation twins, support a shock transformation mechanism for microdiamond formation within the Kenna meteorite. Further supporting this observation, the diamond laths show close alignment of <111> and <110> between domains, consistent with a solid-state transformation from graphite along <0001> and <1-210>, respec-tively [5]. A FIB foil was extracted from a region with mechanical twins, and high resolution STEM analyses reveal cross-cutting veins of graphite and oriented kamacite crystals together with additional sets of {111} nano-twins formed in at least three orientations. Isotopic analyses of C and N reveal sector zoning patterns [cf. 3] that are unre-lated to the diamond substructure identified by EBSD yet consistent with hyperspectral CL images. Conclusions: These data provide new constraints on microdiamond formation within ureilites. The microdia-monds exhibit orientation variants defined by aligned <111> and <110> axes consistent with inherited crystallo-graphic orientations from transformation of a single hexagonal graphite parent crystal [5]. Crosscutting the micro-diamonds are veins of graphite and kamacite, together with additional {111} nanotwins. Taken together these data suggest that microdiamonds from ureilites formed from a solid state, diffusionless transformation from graphite, likely associated with a major shock event, which was subject to subsequent reversion either during decompression or a later deformation event. The N and C isotopic sector zoning is unrelated to diamond microstructures and likely reflects inheritance from the parent graphite crystal.

Ureilite↗

Microcircuit failure analysis using the SEM

The scanning electron microscope adds a new dimension to the knowledge that can be obtained from a failed microcircuit. When used with conventional techniques, SEM assists and clarifies the analysis, but it does not replace light microscopy. The most advantageous features for microcircuit analysis are long working distances and great depth of field. Manufacturer related failure modes of microcircuits are metallization defects, poor bonding, surface and particle contamination, and design and fabrication faults. User related failure modes are caused by abuse, such as overstress. The Physics of Failure Procedure followed by the Astrionics Laboratory in failure analysis is described, which is designed to obtain maximum information available from each step.

Nicolas, D. P.↗

Coaxial carbon plasma gun deposition of amorphous carbon films

A unique plasma gun employing coaxial carbon electrodes was used in an attempt to deposit thin films of amorphous diamond-like carbon. A number of different structural, compositional, and electrical characterization techniques were used to characterize these films. These included scanning electron microscopy, scanning transmission electron microscopy, X ray diffraction and absorption, spectrographic analysis, energy dispersive spectroscopy, and selected area electron diffraction. Optical absorption and electrical resistivity measurements were also performed. The films were determined to be primarily amorphous, with poor adhesion to fused silica substrates. Many inclusions of particulates were found to be present as well. Analysis of these particulates revealed the presence of trace impurities, such as Fe and Cu, which were also found in the graphite electrode material. The electrodes were the source of these impurities. No evidence of diamond-like crystallite structure was found in any of the film samples. Details of the apparatus, experimental procedure, and film characteristics are presented.

Sater, D. M.↗

Verification of computer-aided designs of traveling-wave tubes utilizing novel dynamic refocusers and graphite electrodes for the multistage depressed collector

A computational procedure for the design of TWT-refocuser-MDC systems was used to design a short dynamic refocusing system and highly efficient four-stage depressed collector for a 200-W, 8- to 18-GHz, TWT. The computations were carried out with advanced, multidimensional computer programs which model the electron beam as a series of disks of charge and follow their trajectories from the RF input of the TWT, through the slow-wave structure and refocusing section, to their points of impact in the depressed collector. Secondary emission losses in the MDC were treated semi-quantitatively by injecting a representative beam of secondary electrons into the MDC analysis at the point of impact of each primary beam. A comparison of computed and measured TWT and MDC performance showed very good agreement. The electrodes of the MDC were fabricated from a particular form of isotropic graphite that was selected for its low secondary electron yield, ease of machinability, and vacuum properties. This MDC was tested (at CW) for more than 1000 hr with negligible degradation in TWT and MDC performances.

Ramins, P.↗

Verification of an improved computational design procedure for TWT-dynamic refocuser-MDC systems with secondary electron emission losses

A computational procedure for the design of TWT-refocuser-MDC systems was used to design a short 'dynamic' refocusing system and highly efficient four-stage depressed collector for a 200-W 8-18-GHz TWT. The computations were carried out with advanced multidimensional computer programs which model the electron beam as a series of disks of charge and follow their trajectories from the RF input of the TWT, through the slow-wave structure and refocusing section, to their points of impact in the depressed collector. Secondary emission losses in the MDC were treated semiquantitatively by injecting a representative beam of secondary electrons into the MDC analysis at the point of impact of each primary beam. A comparison of computed and measured TWT and MDC performance showed very good agreement. The electrodes of the MDC were fabricated from a particular form of isotropic graphite that was selected for its low secondary electron yield, thermal expansion characteristics, ease of machinability and vacuum properties. This MDC was tested at CW for more than 1000 h with negligible degradation in TWT and MDC performances.

Ramins, P.↗

Preentry communication design elements for outer planets atmospheric entry probe

Four related tasks are discussed for data transmission from a probe prior to entering the atmosphere of Jupiter to an orbiting spacecraft in a trajectory past the planet: (1) link analysis and design; (2) system conceptual design; (3) Doppler measurement analysis; and (4) an electronically despun antenna. For tasks 1, 3, and 4, an analytical approach was developed and combined with computational capability available to produce quantitative results corresponding to requirements and constraints given by NASA, ARC. One constraint having a major impact on the numerical results of the link analysis was the assumption of a nonsteerable antenna on a spinning orbiter. Other constraints included the interplanetary trajectory and the approach trajectory. Because the Jupiter Orbiter Probe (JOP) program is currently in a state of evolution, all requirements and constraints applied during this study are subject to change. However, the relationships of parameters as developed will remain valid and will aid in planning Jupiter missions.

Source record↗

Preparation of ultra small samples for optical and microprobe analysis

This paper describes a simple but satisfactory new method for the preparation of tiny, varied and specialized specimens for electron or ion-microprobe analysis developed over the past five years. Microtektites, individual chondrules, single grains, blebs from lunar samples and meteoritic minerals have been prepared by this technique. A description of the preparation of these usually difficult samples from the initial mounting through the various polishing steps to their final polish is presented in detail. The procedures used to prevent any contamination of these specimens by the polishing agents and to prevent cross contamination to the other samples used for geochronology studies are presented.

Inman, C. S.↗

X-Ray Photoelectron Spectroscopy

The interaction of photon and the electron goes back to the early part of 19th century emanating from the photo-electric effect depicted by none other than Albert Einstein (Ref 1) described in 1905, and the redistribution of kinetic energy resulting from the interaction of x-ray and solids reported during early part of the century (Ref.2). The spectrum resolutions obtained at that time was not sufficient to observe distinct peaks in spectra for materials. Thus, these phenomena hardly attracted any attention for many years following these discoveries. The modern X-ray Photoelectron Spectroscopy (XPS) has been possible by the extensive and significant contribution from Kai Siegbahn and others (Ref.3, 4) of Uppsala University. Siegbahn developed and employed a high-resolution electron spectrometer that revealed electron peaks in a spectrum emerging from the interaction of x-rays and solids. Eventually, Kai Siegbahn received Nobel Prize in 1981 for his contributions to XPS. Around 1958, shifts in elemental peaks were realized in compounds when the same elements are bound to other but different elements. This discovery resulted in the chemical state identification in various chemicals as well as the oxidation states of atoms in compounds. Because of these useful physical effects, the Uppsala group named XPS with a synonymous name of ESCA (Electron Spectroscopy for Chemical Analysis) used widely today and will be used here alternatively. Therefore, XPS or ESCA not only identifies the element, but also the compound these elements form, from their chemical shifts. Compared to other micro-analytical techniques such as Energy Dispersive (EDS) or Wavelength Dispersive (WDS) techniques, XPS analyzes only few atomic layers present on the surface. This was discovered early in 1966 (Ref. 5). While this has awarded a merit to the analytical technique to analyze very thin layers such as films and coatings, it often analyzes the adsorbed superficial gases and contaminations on a sample introduced to its analytical chamber. This necessitates the surface is cleaned and the underlying material, material of interest, is exposed in a clean environment such that the material of interest is analyzed. The cleaning is accomplished by a scanning ion gun within the analytical chamber of the instrument. Ion gun uses an argon gas and is commonly attached in most modern machines. Reliable and efficient vacuum systems employed in modern machines does not allow adsorbed layers to rebuild after the surface is cleaned. Development of efficient and reliable vacuum pumps over these developmental years is yet another important step in the commercialization of XPS machines. Vacuum levels of better than 10-7 torr are essential to increase the mean free path of electrons released from the sample surface. Thus, modern machines are equipped with high capacity ion, turbo or cryogenic pumps in their analytical chambers. Today, XPS has advanced from an applied physics laboratory to industry for use in quality control as well as analysis of contaminants and has taken a dominant role in microanalysis. Its uniqueness arises from the fact that it is considered non-destructive compared to other common micro-analytical techniques using the electron and ion excitation sources. Polymers and plastics could be analyzed since the binding energies of saturated and unsaturated bonds in atoms could be separated. Extremely thin layers could be analyzed including materials with layered structures. The technique, though did not advance for many years, has now opened a new window for research as well as applications in industry due to its ability to separate and measure the chemical shifts in bound elements. Principles

Panda, Binayak↗

Structural characterization and gas reactions of small metal particles by high resolution in-situ TEM (Transmission Electron Microscopy) and TED (Transmission Electron Diffraction)

The detection and size analysis of small metal particles supported on amorphous substrates becomes increasingly difficult when the particle size approaches that of the phase contrast background structures of the support. An approach of digital image analysis, involving Fourier transformation of the original image, filtering, and image reconstruction was studied with respect to the likelihood of unambiguously detecting particles of less than 1 nm diameter on amorphous substrates from a single electron micrograph.

Heinemann, K.↗

Detailed analysis of low energy plasma data under the Voyager Uranus data analysis program

Research effort included the PLS data analysis program where modifications to the data fitting procedure and elimination of possible noise and electron contamination were made. The analysis code corrections were used in checking the Neptune data gathered during the Voyager 2 encounter and for analyzing selected plasma spectra from the warm Io torus. A major task accomplished was the summary of Uranus-related research in the U.S. National Report to the International Union of Geodesy and Geophysics for the 1987 - 1990 quadrennium. A limited amount of work was accomplished on assessing the Pedersen conductivity of the ionosphere and comparing it with inferred values from shielding by the Uranian ring current. Under this grant there has been a great deal of effort expended on identifying and classifying plasma waves and oscillations in the magnetosheath and solar wind downstream from Uranus. Large amplitude oscillations in plasma parameters are found in the magnetosheath, with density changes of up to a factor of ten occurring on times scales of minutes. New algorithms developed for analyzing the inbound bow shock crossing of Neptune will probably be applied to a more detailed analysis of the Uranus shock in the near future.

Mcnutt, Ralph L., Jr.↗

Space Shuttle Columbia Aging Wiring Failure Analysis

A Space Shuttle Columbia main engine controller 14 AWG wire short circuited during the launch of STS-93. Post-flight examination divulged that the wire had electrically arced against the head of a nearby bolt. More extensive inspection revealed additional damage to the subject wire, and to other wires as well from the mid-body of Columbia. The shorted wire was to have been constructed from nickel-plated copper conductors surrounded by the polyimide insulation Kapton, top-coated with an aromatic polyimide resin. The wires were analyzed via scanning electron microscope (SEM), energy dispersive X-Ray spectroscopy (EDX), and electron spectroscopy for chemical analysis (ESCA); differential scanning calorimetry (DSC) and thermal gravimetric analysis (TGA) were performed on the polyimide. Exemplar testing under laboratory conditions was performed to replicate the mechanical damage characteristics evident on the failed wires. The exemplar testing included a step test, where, as the name implies, a person stepped on a simulated wire bundle that rested upon a bolt head. Likewise, a shear test that forced a bolt head and a torque tip against a wire was performed to attempt to damage the insulation and conductor. Additionally, a vibration test was performed to determine if a wire bundle would abrade when vibrated against the head of a bolt. Also, an abrasion test was undertaken to determine if the polyimide of the wire could be damaged by rubbing against convolex helical tubing. Finally, an impact test was performed to ascertain if the use of the tubing would protect the wire from the strike of a foreign object.

McDaniels, Steven J.↗

Transport properties of monatomic carbon. II - Contributions from excited electronic states

The aim of the present analysis is to verify the conventional assumption that the transport properties of atoms and molecules in excited electronic states are nearly the same as in the ground state. Reasonably exact calculations of the transport properties of excited-state carbon atoms are obtained on the basis of available experimental and theoretical data on the interactions between carbon atoms in excited electronic states. A comparison with results obtained with several models that have been used to estimate the transport properties of excited species indicates that the assumption under consideration is correct, but that the models do not predict very accurately the transport properties of excited species.

Biolsi, L.↗

Io plasma torus electrons - Voyager 1

A thermal Maxwellian component of the electron distribution function, together with a suprathermal, non-Maxwellian one, are featured in the present analysis of in situ plasma electron observations made by the Voyager 1 plasma science experiment in the Io plasma torus. A large difference in the hot electron pressure P(H) is noted between the inbound and the outbound data; this is interpreted as a latitudinal gradient, with P(H) being maximum at the magnetic equator. The presence of a neutral corona around Io is inferred from the observed decrease and symmetry with respect to Io of the cold electron temperature.

Sittler, E. C., Jr.↗

The application of surface analysis to polymer/metal adhesion

The use of scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) in the analysis of Ti 6-4 adherend surfaces is described. Differences in Ti 6-4 surface composition as determined by XPS after different chemical pretreatments are detailed. Analysis of fractured surfaces by SEM/XPS is used to establish the failure mode. The surface acidity of Ti 6-4 coupons can be established by reflectance visible spectroscopy using indicator dyes.

Wightman, J. P.↗