Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Origin and characterization of single-electron events in Skipper-CCDs for light dark matter searches

This manuscript summarizes the work carried out within the SENSEI (Sub-Electron-Noise Skipper-CCD Experimental Instrument) collaboration, an effort focused on the search for light dark matter using Skipper-CCDs. Firstly, it presents the data acquisition and processing protocol developed to establish a selection criteria for events compatible with the dark matter signal. This protocol also enabled the structure and tools used for the study and characterization of phenomena that impact the quality of measurements made in the search for dark matter (measurement of the Fano factor, determination of the Compton background, and characterization of the high-energy surface background), which were carried out during this work. Secondly, it discusses the comprehensive study conducted on the origin of single-electron events in Skipper-CCDs, which allowed for the selection of detector operating parameters and improved the detection sensitivity in the search for dark matter. It is highlighted the characterization of the spatial correlation between single-electron events and high-energy events, among other developed event selection criteria, and the optimization of the output device to reduce sources of luminescence during its operation. As a result of this study, the lowest levels of dark current and spurious charge ever measured in a CCD are reported. Finally, the latest published results from SENSEI are presented. The obtained limits for the scattering of a light mediator are the best reported to date across the entire investigated mass range, while for the heavy mediator, they are the best for masses below 10 MeV. In terms of dark matter absorption, the most restringent limits below 10 eV are reported. These results, achieved with only a very small fraction of the total projected exposure for SENSEI, position Skipper-CCDs as leaders in the search for light dark matter worldwide.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the underground muon detector of the Pierre Auger Observatory

To obtain direct measurements of the muon content of extensive air showers with energy above 10 16.5 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m 2 -modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m 2 close to the intersection of the shower axis with the ground to much less than one per m 2 when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A LArTPC with Vertical Drift for the DUNE Far Detector

The Far Detector of the Deep Underground Neutrino Experiment (DUNE) will be a large LArdetector located at a baseline of 1300 kilometers, 1.5 km deep underground. It is planned to bemade up of four modules, each with a total mass of 17 kt of LAr, at least the first two of which willconsist in Liquid Argon Time Projection Chambers (LArTPCs). To prove the feasibility of theLArTPC technology at the kiloton scale, the ProtoDUNE Single and Dual-Phase detectors wereconstructed and operated at the CERN Neutrino facility.This document describes the Vertical Drift detector concept, which is proposed to instrument thesecond DUNE module. It consists of a TPC where the electrons drift vertically, with a cathodesuspended at mid-height, towards anodes placed at the bottom and top of the detector. The anodeswould be made out of printed PCBs instead of wires, and the new disposition would allow the topreadout electronics to be accessible during the lifetime of the experiment. An enhanced photo-detection system is also proposed, with the photo-sensors placed on the cryostat walls and thecathode, but posing a challenge in terms of power and signal transmission. Studies are ongoingboth to overcome the technical challenges of this new design and to finalize the concept.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of skipper CCDs for cosmological applications

We characterize the response of a novel 250 µm thick, fully-depleted Skipper Charged-Coupled Device (CCD) to visible/near-infrared light with a focus on potential applications for astronomical observations. We achieve stable, single-electron resolution with readout noise &sigma; 0.18 e - rms/pix from 400 non-destructive measurements of the charge in each pixel. We verify that the gain derived from photon transfer curve measurements agrees with the gain calculated from the quantized charge of individual electrons to within < 1%. We also perform relative quantum efficiency measurements and demonstrate high relative quantum efficiency at optical/near- infrared wavelengths, as is expected for a thick, fully depleted detector. Finally, we demonstrate the ability to perform multiple non-destructive measurements and achieve sub-electron readout noise over configurable sub- regions of the detector. This work is the first step toward demonstrating the utility of Skipper CCDs for future astronomical and cosmological applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exclusive J/$\psi$ detection and physics with ECCE

The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been recommended as a reference design for the proposed Electron-Ion Collider (EIC) program. Here, this paper presents simulation studies of exclusive J/$\psi$ detection and selected physics impact results in EIC using the projected ECCE detector concept. Exclusive quarkonium photoproduction is one of the most popular processes in EIC, which has a large cross section and a simple final state. Due to the gluonic nature of the exchange Pomeron, this process can be related to the gluon distributions in the nucleus. Preliminary results estimate the excellent statistics benefited from the large cross section of J/$\psi$ photoproduction and superior performance of ECCE detector concept. The precise measurement of exclusive J/$\psi$ photoproduction at EIC will help us to more deeply understand nuclear gluon distributions, near threshold production mechanism and nucleon mass structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform

The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of 7.2× 6.1× 7.0 m3. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV/c to 7 GeV/c. Beam line instrumentation provides accurate momentum measurements and particle identification. The ProtoDUNE-SP detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment, and it incorporates full-size components as designed for that module. This paper describes the beam line, the time projection chamber, the photon detectors, the cosmic-ray tagger, the signal processing and particle reconstruction. It presents the first results on ProtoDUNE-SP's performance, including noise and gain measurements, dE/dx calibration for muons, protons, pions and electrons, drift electron lifetime measurements, and photon detector noise, signal sensitivity and time resolution measurements. The measured values meet or exceed the specifications for the DUNE far detector, in several cases by large margins. ProtoDUNE-SP's successful operation starting in 2018 and its production of large samples of high-quality data demonstrate the effectiveness of the single-phase far detector design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development, construction and tests of the Mu2e electromagnetic calorimeter mechanical structures

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the charged lepton flavour violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of the existence of physics beyond the standard model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. In particular, the calorimeter provides excellent electron identification, a fast calorimetric online trigger, and complementary information to aid pattern recognition and track reconstruction. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total expected ionizing dose of 12 krad and a neutron fluence of 5 × 10$^{10}$ n/cm$^{2}$ @ 1 MeV$_{eq}$ (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on scintillating materials, sensors, electronics and on the design of the detector mechanical structures and material choice. The support structure of each 674 crystal matrix is composed of an aluminum hollow ring and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and front-end electronics for the readout of each crystal are inserted in a machined copper holder and make a unique mechanical unit. The resulting 674 mechanical units are supported by a machined plate of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics are hosted in aluminum custom crates positioned on the external lateral surface of the disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system. In this paper we report on the calorimeter mechanical structure design, the mechanical and thermal simulations that have determined the design technological choices, and the status of component production, quality assurance tests and plans for assembly at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-Stage Cryogenic HEMT-Based Amplifier for Low-Temperature Detectors

To search for dark matter candidates with masses below $\mathcal{O}$ (MeV), the SPLENDOR (Search for Particles of Light dark mattEr with Narrow-gap semiconDuctORs) experiment is developing novel narrow-bandgap semiconductors with electronic bandgaps on the order of 1–100 meV. In order to detect the charge signal produced by scattering or absorption events, SPLENDOR has designed a two-stage cryogenic HEMT-based amplifier with an estimated charge resolution approaching the single-electron level. A low-capacitance (~ 1.6 pF) HEMT is used as a buffer stage at T = 10 mK to mitigate effects of stray capacitance at the input. The buffered signal is then amplified by a higher-capacitance (~ 200 pF) HEMT amplifier stage at T = 4 K. Importantly, the design of this amplifier makes it usable with any insulating material—allowing for rapid prototyping of a variety of novel detector materials. Here, we present the two-stage cryogenic amplifier design, preliminary voltage noise performance, and estimated charge resolution of 7.2 electrons.

47 OTHER INSTRUMENTATION↗

The Mu2e experiment — Searching for charged lepton flavor violation

The Mu2e experiment will search for a Standard Model violating rate of neutrinoless conversion of a muon into an electron in the presence of an aluminum nucleus. Observation of this charged lepton flavor violating process would be an unambiguous sign of new physics. Mu2e will improve upon previous searches for this process by four orders of magnitude. This requires the world’s highest-intensity muon beam, a detector system capable of efficiently reconstructing the 105 MeV/c conversion electron signal, and minimizing sensitivity to background events. A pulsed 8 GeV proton beam strikes a target, producing pions that decay into muons. Beam outside the pulse must be suppressed to < 1 0 – 10 to reduce beam-related backgrounds. The muon beam is guided from the production target along the transport system and onto the aluminum stopping target. Conversion electrons leave the stopping target and propagate inside a solenoidal magnetic field to the tracker and electromagnetic calorimeter. The tracker is a system of straw tube panels filled with Ar/CO 2 at 1 atm that tracks particles inside of a solenoidal B-field and measures their momenta with ~ 100 keV/c resolution to resolve signal events from decay-in-orbit backgrounds. The CsI calorimeter provides E / p and is used to seed the track reconstruction algorithm with σ E / E ~ 10 % and σ t < 500 ps . Additionally, a novel cosmic ray veto with greater than 99.99% efficiency brings the expected number of background events to fewer than one over three years of running. Finally, to normalize the experiment, the stopping target monitor measures the rate of capture photons from muons incident on the stopping target by using a system of high-purity germanium and lanthanum bromide scintillators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Limits on Millicharged Particles Using the ArgoNeuT Experiment at Fermilab

A search for millicharged particles, a simple extension of the standard model, has been performed with the ArgoNeuT detector exposed to the Neutrinos at the Main Injector beam at Fermilab. The ArgoNeuT liquid argon time projection chamber detector enables a search for millicharged particles through the detection of visible electron recoils. We search for an event signature with two soft hits (MeV-scale energy depositions) aligned with the upstream target. For an exposure of the detector of 1.0×10 20 protons on target, one candidate event has been observed, compatible with the expected background. This search is sensitive to millicharged particles with charges between 10 -3 $e$ and 10 -1 $e$ and with masses in the range from 0.1 to 3 GeV. This measurement provides leading constraints on millicharged particles in this large unexplored parameter space region.

43 PARTICLE ACCELERATORS↗

First Direct-Detection Results on Sub-GeV Dark Matter Using the SENSEI Detector at SNOLAB

Here, we present the first results from a dark matter search using six Skipper-CCDs in the SENSEI detector operating at SNOLAB. We employ a bias-mitigation technique of hiding approximately 46% of our total data and aggressively mask images to remove backgrounds. Given a total exposure after masking of 100.72 gram-days from well-performing sensors, we observe 55 two-electron events, 4 three-electron events, and no events containing 4–10 electrons. The two-electron events are consistent with pileup from one-electron events. Among the 4 three-electron events, 2 appear in pixels that are likely impacted by detector defects, although not strongly enough to trigger our “hot-pixel” mask. We use these data to set world-leading constraints on sub-GeV dark matter interacting with electrons and nuclei.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of the spatial shift in detector response for polarized protons within a calorimeter

Measurement of the helicity dependent elastic electron-proton scattering cross section provides a key means of investigating parity violation within the proton. However, such measurements exhibit potential instrumental effects associated with the detection of polarized recoiled protons. In particular, spin-orbit interactions within a massive detector induce a systematic spatial shift in the detector signal. In this study, we determine the size of this shift using the Geant4 simulation toolkit. For a typical hadron calorimeter, we found a polarization dependent shift on the order of 0.01-0.1 mm, multiple orders of magnitude smaller than the typical spatial resolution seen in hadronic calorimeters. Additionally, we provide the custom modifications required of the Geant4 source code to implement the quasi-elastic scattering of polarized protons incident on nuclei in the detector. The modifications are readily extendable to generic matter sources, and can be used for the study of additional spin dependent observables in Geant4.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-standard neutrino interactions in light mediator models at reactor experiments

Compared to other neutrino sources, the huge anti-neutrino fluxes at nuclear reactor based experiments empower us to derive stronger bounds on non-standard interactions of neutrinos with electrons mediated by light scalar/vector mediators. At neutrino energy around 200 keV reactor anti-neutrino flux is at least an order of magnitude larger compared to the solar flux. The atomic and crystal form factors of the detector materials related to the details of the atomic structure becomes relevant at this energy scale as the momentum transfers would be small. Non-standard neutrino-electron interaction mediated by light scalar/vector mediator arises naturally in many low-scale models. We also propose one such new model with a light scalar mediator. Here, we investigate the parameter space of such low-scale models in reactor based neutrino experiments with low threshold Ge and Si detectors, and find the prospect of probing/ruling out the relevant parameter space by finding the projected sensitivity at 90% confidence level by performing a $χ$ 2 -analysis. We find that a detector capable of discriminating between electron recoil and nuclear recoil signal down to a very low threshold such as 5 eV placed in reactor based experiment would be able to probe a larger region in parameter space compared to the previously explored region. A Ge (Si) detector with 10 kg-yr exposure and 1 MW reactor anti-neutrino flux would be able to probe the scalar and vector mediators with masses below 1 keV for coupling products $\sqrt{g_vg_e}$ ~ 1 × 10 -6 (9.5 × 10 -7 ) and 1 × 10 -7 (8 × 10 -8 ), respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for pair production of scalar leptoquarks decaying into first- or second-generation leptons and top quarks in proton–proton collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

A search for pair production of scalar leptoquarks, each decaying into either an electron or a muon and a top quark, is presented. This is the first leptoquark search using ATLAS data to investigate top-philic cross-generational couplings that could provide explanations for recently observed anomalies in B meson decays. This analysis targets high leptoquark masses which cause the decay products of each resultant top quark to be contained within a single high-p T large-radius jet. The full Run 2 dataset is exploited, consisting of 139 fb -1 of data collected from proton–proton collisions at √s=13 TeV from 2015 to 2018 with the ATLAS detector at the CERN Large Hadron Collider. In the absence of any significant deviation from the background expectation, lower limits on the leptoquark masses are set at 1480 GeV and 1470 GeV for the electron and muon channel, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Construction status of the Mu2e crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged-lepton flavor violating neutrino-less conversion of a negative muon into an electron in the field of an aluminum nucleus. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter plays an important role in providing excellent particle identification capabilities and a fast online trigger filter, while aiding the track reconstruction capabilities. Calorimeter requirements are to provide a large acceptance for 0~10 MeV electrons and reach: i) a time resolution better than 0.5 ns; ii) an energy resolution better than 10%; and iii) a position resolution of 1 cm. The calorimeter consists of two disks, each one made of 674 pure CsI crystals. Each crystal is readout by two large area 2×3 arrays of UV-extended SiPMs of 6×6 mm2 dimensions. A large scale prototype (Module-0) has been tested at an electron beam. We report here the tests done to finalize the calorimeter design, the results obtained with Module-0 and the status of production. At this time, the performance characteristics of 85% of the crystals and all of the SiPMs have been measured. The calorimeter engineering drawings have been completed and the large mechanical components are under fabrication. Analog and digital electronics have been prototyped and tested with irradiation dose. Their serial production is being organized. The calorimeter assembly phase is planned for mid-2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Charge collection and electrical characterization of neutron irradiated silicon pad detectors for the CMS High Granularity Calorimeter

The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and timing information on electromagnetic and hadronic showers in the immense pileup of the HL-LHC. The High Granularity Calorimeter (HGCAL) will use 120-, 200-, and 300-$\mu\textrm{m}$ thick silicon (Si) pad sensors as the main active material and will sustain 1-MeV neutron equivalent fluences up to about $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$. In order to address the performance degradation of the Si detectors caused by the intense radiation environment, irradiation campaigns of test diode samples from 8-inch and 6-inch wafers were performed in two reactors. Characterization of the electrical and charge collection properties after irradiation involved both bulk polarities for the three sensor thicknesses. Since the Si sensors will be operated at -30 $^\circ$C to reduce increasing bulk leakage current with fluence, the charge collection investigation of 30 irradiated samples was carried out with the infrared-TCT setup at -30 $^\circ$C. TCAD simulation results at the lower fluences are in close agreement with the experimental results and provide predictions of sensor performance for the lower fluence regions not covered by the experimental study. All investigated sensors display 60$\%$ or higher charge collection efficiency at their respective highest lifetime fluences when operated at 800 V, and display above 90$\%$ at the lowest fluence, at 600 V. The collected charge close to the fluence of $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$ exceeds 1 fC at voltages beyond 800 V.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correlated single- and few-electron backgrounds milliseconds after interactions in dual-phase liquid xenon time projection chambers

In this work, we characterize single- and few-electron backgrounds that are observed in dual-phase liquid xenon time projection chambers at timescales greatly exceeding a maximum drift time after an interaction. These instrumental backgrounds limit a detector's sensitivity to dark matter and cosmogenic neutrinos. Using the ~150g liquid xenon detector at Purdue University, we investigate how these backgrounds, produced after 122keV 57 Co Compton interactions, behave under different detector conditions. We find that the rates of single- and few-electron signals follow power-laws with time after the interaction. We observe linearly increasing rates with increased extraction field, and increased rates in the single-electron background with increased drift field. Normalizing the rates to the primary interaction's measured ionization signal, the rates increase linearly with the depth of the interaction. We test the hypothesis that infrared photons (1550nm) would stimulate and accelerate electron emission via photodetachment from impurities, but find that even 1 Watt of infrared light fails to reduce these backgrounds. We thus provide a characterization that can inform background models for low-energy rare event searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large-volume CdZnTe bar detectors characterized by laser-induced transient currents

In this work, we studied the free-carrier transport properties and space-charge formation/polarization in a CdZnTe bar-shaped radiation detector using the Laser-Induced Transient Current technique. We found out that a steady-state space charge ranging from 8 x 10 8 to 2.1 x 10 9 cm -3 is formed throughout the detector at about 0.5 s following biasing. The measured current waveforms were modeled by Monte Carlo simulations after taking into account the electric and weighting fields inside the detector and shielding box. Modeling of the unpolarized waveforms revealed an exceptionally high electron mobility-lifetime product μ e τ e ≥0.095cm 2 V -1 . The observed formation of positive space charge in the biased detector and linear scaling of the current waveform shapes on applied bias revealed that the detector polarization is attributed to carrier injection at the anode. In conclusion, measurements in pulsed and DC bias in modified electrode geometry proved the surface-charge formation.

47 OTHER INSTRUMENTATION↗