Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Maximizing Uptake of Hygroscopic Hydrogels Through Extreme Swelling-Induced Salt Loading

Hygroscopic hydrogels have emerged as scalable and low-cost materials with the potential of high-performance vapor sorption for atmospheric water harvesting, dehumidification, and passive cooling. Despite extensive research interest aimed at improving hygroscopic hydrogels, devices using these materials still exhibit insufficient performance, partly due to limited water uptake of the hydrogels. In this work, we study the swelling dynamics of hydrogels in aqueous lithium chloride solutions and use this to achieve extreme salt loading of hygroscopic hydrogels. By rationally tuning the salt concentration used for swelling we achieve successful synthesis of hygroscopic hydrogels with high water uptake of 1.76 g/g, 2.53 g/g, 3.80 g/g at relative humidites of 30%, 50%, and 70%, respectively, exceeding previous hydrogels by over 19%. These water uptakes bring the performance of hydrogels within ≈91% of the fundamental limit of commonly used hygroscopic salts, while still avoiding leakage problems common in salt solutions. Furthermore, we elucidate via models the maximum uptake achievable without leakage as a function of the operating relative humidity and hydrogel swelling ratio. The insights from this work can be used to design hygroscopic hydrogels with exceptional performance for a wide variety of sorption applications to tackle global challenges such as water scarcity and energy efficiency.

25 ENERGY STORAGE↗

Enhancing building energy performance by effectively using phase change material and dynamic insulation in walls

Deploying phase change materials (PCMs) in building envelopes can be efficacious in reducing space heating/cooling loads and providing load shedding and shifting capacity. However, the full potential of PCM-integrated envelopes can only be harnessed if the PCM undergoes phase change using free ambient heating/cooling, and the stored energy is effectively transferred between the exterior and the interior environments. Traditional thermal insulation (with a fixed thermal resistance) limits PCM utilization, which restrains the energy saving potential of a PCM-integrated envelope to a small percentage. Proposed dynamic insulation material and system (DIMS) provides the option of varying its thermal resistance based on the indoor and outdoor conditions. Although it has been established that employing PCM as well as DIMS in building envelopes separately improves buildings’ energy performance, no prior studies that analyzed the combined influence of both technologies were identified. In this study, we examine a novel wall design, comprising a layer of PCM between two layers of DIMS. We note that the PCM-DIMS-integrated wall provides significantly higher energy saving potential than the DIMS-only integrated wall or the PCM-only integrated wall in all the climates and wall orientations analyzed in this study. Depending on the climate, the PCM-DIMS-integrated wall could provide 15–72% reduction in annual heat gain and 7–38% reduction in annual heat loss. The analysis presented in this study supports the need to develop scalable dynamic insulations combined with thermal energy storage systems for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Co-existence of atomically dispersed Ru and Ce 3+ sites is responsible for excellent low temperature N 2 O reduction activity of Ru/CeO 2

Nitrous oxide N 2 O reduction is a big challenge due to high global warming potential of N 2 O. (~300 times higher compared with CO 2 ). The best known catalysts, such as Rh/ceria, require relatively high temperatures for N 2 O decomposition. Herein, we report that Ru/ceria catalysts with low Ru loading of ~0.25 wt% efficiently catalyze low temperature N 2 O reduction by CO starting at 100 °C (full N 2 O conversion below 200 °C) under industrially relevant flow rates and gas concentrations. Further, this remarkable performance stems from maintaining isolated Ru cations even on reduced ceria surface and, simultaneously, the propensity of Ru to affect ceria surface to form labile surface oxygen thereby creating large number of oxygen vacancies (Ce +3 cations) in the presence of CO. In contrast, for Rh/CeO 2 catalysts with equivalent metal loading, the activity is much lower because atomically dispersed Rh sinters into metallic clusters at the onset reaction temperature (~200 °C): these clusters are much less effective than isolated single Ru ions, with lower Ce +3 concentration maintained on reduced Rh/CeO 2 catalyst. Our study highlights the benefits of gaining molecular-level insight into the dynamic nature of catalytically active sites under reaction conditions for preparing catalysts containing low loading of precious metals with unsurpassed low temperature activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improving Primary Frequency Response in Networked Microgrid Operations using Multilayer Perceptron-Driven Reinforcement Learning

Individual microgrids can improve the reliability of power grids during extreme events, and networked microgrids can further improve efficiency through resource sharing and increase the resilience of critical end-use loads. However, networked microgrid operations are subject to large switching transients, which can cause dynamic instability and lead to system collapse. These transients are especially prevalent in microgrids with high penetrations of inverter-connected renewable energy resources, which do not provide the system inertia needed to mitigate the transients. Existing generator controls can be modified to invoke a drop in terminal voltage in response to a frequency deviation, thereby reducing load and improving frequency response. This paper investigates the use of a reinforcement-learning--based controller trained over several switching transient scenarios to modify generator controls during large frequency deviations. Compared to previously used proportional integral controllers, the proposed controller can improve primary frequency response while adapting to changes in system topologies and events.

Radhakrishnan, Nikitha↗

Active liquid crystals powered by force-sensing DNA-motor clusters

Significance Single-molecule techniques have elucidated how isolated molecular motors generate piconewton forces with unprecedented detail. However, in diverse biological and synthetic settings, force-generating proteins collectively power nonequilibrium dynamics, including continuous large-scale rearrangements and persistent fluid flows. Characterizing motor-generated forces in these dense and dynamical environments remains a challenge. We assembled a reversible DNA-based force-sensing probe that, by an optical readout, reveals the molecular arrangements and the force loads experienced by kinesin motors. These probes provide insight into motor-generated forces that collectively power the unique dynamics of microtubule-based active nematics, a noteworthy example of an internally driven active matter system. DNA-based force probes can be extended to study forces and stresses in various synthetic systems as well as diverse cellular environments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tuning of Nacelle Feedback Gains for Floating Wind Turbine Controllers Using a Two-DOF Model

Designing a collective blade pitch controller for floating offshore wind turbines (FOWTs) poses unique challenges due to the interaction of the controller with the dynamics of the platform. The controller must also handle the competing objectives of power production performance and fatigue load management. Existing solutions either detune the controller with the result of slowed response, make use of complicated tuning methods, or incorporate a nacelle velocity feedback gain. With the goal of developing a simple control tuning method for the general FOWT researcher that is easily extensible to a wide array of turbine and hull configurations, this last idea is built upon by proposing a simple tuning strategy for the feedback gain. This strategy uses a two degree-of-freedom (DoF) turbine model that considers tower-top fore-aft and rotor angular displacements. For evaluation, the nacelle velocity term is added to an existing gain scheduled proportional-integral controller as a proportional gain. The modified controller is then compared to baseline land-based and detuned controllers on an example system for several load cases. First-pass results are favorable, demonstrating how researchers can use the proposed tuning method to efficiently schedule gains for adequate controller performance as they investigate new FOWT configurations.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Applying Quantum Computing to Simulate Power System Dynamics

Power system dynamics are generally modeled by high dimensional nonlinear differential-algebraic equations due to a large number of generators, loads, and transmission lines. Thus, its computational complexity grows exponentially with the system size. This paper demonstrates the potential use of quantum computing algorithms to model the power system dynamics. Leveraging a symbolic programming framework, we equivalently convert the power system dynamics’ differential algebraic equations (DAEs) into ordinary differential equations (ODEs), where the data of the state vector can be encoded into quantum computers via amplitude encoding. The system's nonlinearity is captured by Taylor polynomial expansion, the quantum state tensor, and Hamiltonian simulation, whereas state variables can be updated by a quantum linear equation solver. Our results show that quantum computing can simulate the dynamics of the power system with high accuracy, whereas its complexity is polynomial in the logarithm of the system dimension. Our work also illustrates the use of scientific machine learning tools for implementing scientific computing concepts, e.g., Taylor expansion, DAEs/ODEs transform, and quantum computing solver, in the field of power engineering.

Tran, Huynh↗

Existing Methods for Grid Strength Assessment and Role of Hydropower in Future Grids

The power system is undergoing rapid evolution with increasing penetration of inverter-based resources (IBRs), large loads, microgrids, and power electronic devices. Ensuring reliable and stable operation of the modern power grid is a multi-faceted challenge that requires detailed understanding of this complex system. Dynamic stability is a major concern in maintaining the security of power grids as the generation mixes and large loads transitions to include high shares of power electronic devices. The operation of IBRs in regions with low system strength and higher grid impedances has been found to be the main reason behind many of the power system instabilities that manifest themselves in various types of oscillations and interactions that, if not properly addressed and damped, can jeopardize the reliable operation of the power system. Weak grid conditions compound such stability problems, particularly when many IBRs operate in proximity to and connect to weak power grids. Therefore, it is important to assess grid strength for planning, integration and operation of IBRs for a given power system. In this report, we aim to understand and classify existing methodologies for grid strength assessment, along with their limitations and future needs. Further, we aim to utilize the huge untapped potential in utilizing hydro energy resources in addressing some of the pertinent challenges of grid strength and reliable operation of modern power systems. Hydropower, historically valued for its flexibility and dispatchability, now faces new constraints due to reduced share of synchronous machines in the generation mix and seasonal variability of available water resources. Yet, these same plants present untapped potential beyond energy generation - notably, as providers of critical grid services. This report explores how hydropower plants, particularly through operation as synchronous condensers, can play a pivotal role in strengthening the grid amid evolving system dynamics.

13 HYDRO ENERGY↗

An analysis of the hybrid internal mass modeling approach in EnergyPlus

Accurate simulation of building system dynamics is particularly important for understanding building energy flexibility. Among all dynamics in a building, a zone temperature’s variation is especially important, as it significantly affects a building’s electricity load profile when its heating, ventilating, and air conditioning (HVAC) system is controlled with on/off cycles or setpoint reset strategies. To accurately simulate a zone temperature’s dynamics, internal mass needs to be modeled carefully. In this paper, we compare the two internal mass modeling approaches provided by EnergyPlus, i.e., internal mass object and zone air capacitance multiplier, to better understand their impacts on zone temperature simulation. Real building zone temperature dynamic data from small- and medium-sized office buildings are analyzed and compared with simulated data. In particular, we illustrate the effectiveness of a hybrid method of the two EnergyPlus modeling approaches, which yields more realistic zone temperature dynamics, especially when the zone is conditioned with heat pump systems with on/off cycling.

Chen, Zhelun↗

Empirical Assessment of the Appliance-Level Load Shape and Demand Response Potential in India

Over the next 15 years, electricity demand from the key residential and commercial appliances is projected to be nearly 300 GW or ~65% of India’s total peak demand. The objective of this study is to characterize appliance level demand and temporal variation, and identify the overall DR potential in India. We use Bangalore Electricity Supply Company territory (peak load of 3,505 MW in 2016) as a case study, using actual one-minute resolution load data for 2,979 distribution feeders and a detailed load survey. Our results show that agricultural pumping and space cooling (residential, commercial, and industrial) are the main contributors to the peak demand – with shares of 23-27% and 14-23%, respectively. Both sectors have about 1,000 MW of DR potential – agricultural pumps offering load shifting service while space cooling offering shimmy service that is capable of dynamically adjusting to react to short-run ramps and grid disturbances. Residential electric water heaters contribute nearly 18% of the winter morning peak demand and can also offer about 500 MW in shimmy service. Overall, we find that shifting and shimmy services offer 1,199 MW and 1,511 MW total DR potential, respectively.

demand response↗

Challenges in Rotor Aerodynamic Modeling for Non-Uniform Inflow Conditions

Within an international collaboration framework, the accuracy of rotor aerodynamic models used for design load calculations of wind turbines is being assessed. Where the use of high-fidelity computation fluid dynamics (CFD) and mid-fidelity free-vortex wake (FVW) models has become commonplace within the wind energy community, these still fail to meet the requirements in terms of execution time and computational cost needed for design load calculations. The fast but engineering fidelity blade-element/momentum (BEM) method can therefore still be considered the industry workhorse for design load simulations. At the same time, upscaling of wind turbine rotors makes inflow non-uniformities (e.g. shear, veer, turbulence) more important. The objective of this work is to assess model accuracy in non-uniform inflow conditions, which violate several BEM assumptions. Thereto a comparison in turbulent inflow has been executed including a wide variety of codes, focusing on the DanAero field measurements, where a 2.3-MW turbine was equipped with, among other sensors, a pressure measurement apparatus. The results indicate that, although average load patterns are in good agreement, this does not hold for the unsteady loads that drive fatigue damage and aero-elastic stability. A simplified comparison round in vertical shear was initiated to investigate the observed differences in a more controlled manner. A consistent offset in load amplitude was observed between CFD and free-vortex codes on the one hand and BEM-type codes on the other hand. To shed more light on the observations, dedicated efforts are ongoing to pinpoint the cause for these differences, in the end leading to guidelines for an improved BEM implementation.

17 WIND ENERGY↗

Rigid-flexible coupling multi-body dynamics modeling of a semi-submersible floating offshore wind turbine

A 14-degree-of-freedom (14-DOF) flexible multibody dynamics model is developed and verified for a semi-submersible floating offshore wind turbine (FOWT). The model considers the coupled dynamics of the platform, tower, nacelle, blades, and mooring subjected to external wind and wave loads. The platform is simplified as a rigid body connected to the seabed by the mooring system. The tower and blade are modeled as flexible cantilever beams. The energy method is used to derive the governing equations of motion, where the kinetic energy, potential energy, and work done by external wind-wave forces are all deduced in a global coordinate system. The 5-MW baseline semi-submersible FOWT is used to verify the derived model against the results simulated from FAST developed by the US National Renewable Energy Laboratory (NREL) at two scenarios: free decay state and different wind-wave load cases. Results show that the established FOWT model can well reflect the vibration characteristics of FAST model. The application of the model to the control of platform pitch with a tuned mass damper is studied. Furthermore, the simplified model could provide a low-order method for the structural dynamics analysis and advanced vibration control design for the multi-body components of the semi-submersible FOWT in the future.

17 WIND ENERGY↗

Stochastic Virtual Battery Modeling of Uncertain Electrical Loads using Variational Autoencoder

Effective utilization of flexible loads for grid services, while satisfying end-user preferences and constraints, requires an accurate estimation of the aggregated predictive flexibility offered by the electrical loads. Recently, there have been efforts to quantify the predictive flexibility of thermostatic loads (e.g. residential air-conditioners, electric water-heaters) using the notion of virtual battery (VB), whose state evolution is governed by a first order dynamics including self-dissipation rate, and power and energy capacities. Identifying the VB model parameters for a collection of thermostatic loads, however, is challenging primarily due to uncertainties and lack of information regarding the end-user behavior, underlying device models and parameters. In this paper, we propose a \textit{variational autoencoder}-based deep learning algorithm to identify the parameters of the VB model. Using available sensors and meters data, the proposed algorithm generates not only point estimates of the VB parameters, but also confidence intervals around those values. Effectiveness of the proposed frameworks is demonstrated on a collection of electric water-heater loads, whose operation is driven by uncertain water usage profiles.

virtual battery, deep learning algorithms↗

Commercial building HVAC demand flexibility with model predictive control: Field demonstration and literature insights

Model Predictive Control (MPC) for building Heating Ventilation and Air Conditioning (HVAC) systems is beginning to gain traction in the market, with a few controls companies incorporating it into their product offerings. However, it remains difficult to assess whether the energy cost savings are enough to justify the cost of MPC implementation for a particular building, given the limited number of reported demonstrations. For small commercial and residential buildings with relatively uniform systems, standardized approaches can help lower implementation costs. In contrast, for large buildings or district systems, the potential magnitude of cost savings could justify more customized solutions. Estimating the cost-effectiveness of MPC becomes more challenging for medium and large commercial buildings, where a one-size-fits-all solution may not be suitable, and the potential energy cost savings may be insufficient to justify a customized solution. To make MPC technology more appealing, incorporating additional value streams beyond energy efficiency alone can significantly increase its attractiveness. One such revenue stream is demand flexibility, in response to dynamic electricity prices, where MPC can leverage the thermal mass of the building to shift the load and support the grid. Building on an extensive literature review of MPC field studies focused on cost savings and demand flexibility, this paper presents the results of implementing MPC control in a large office building HVAC system in Berkeley, CA. Four different dynamic electricity price profiles were integrated into the MPC objective function to shift building demand while maintaining comfort, and field testing was performed with each price profile across four seasons. The results show potential for 40–65 % demand decrease percentage and up to 61 % annual cost savings compared to the existing rule-based control strategy, under the tested dynamic price scenarios. This paper also presents a sensitivity analysis on the cost savings with respect to the price profile variability, discusses the implementation effort for the price-responsive MPC, and compares the cost savings found in this study to those found in literature on the basis of dynamic price variability, or so-called Electricity Price Relative Standard Deviation.

Zanetti, Ettore↗

A New Distributed Model-Free Control Strategy to Diminish Distribution System Voltage Violations

This paper proposes a new distributed model-free control (MFC) strategy for dynamic voltage control to diminish distribution systems' voltage violations. The objective is to maintain all critical load bus voltages within the acceptable ANSI Range A (+/- 5% of nominal). The distributed MFC strategy, which only requires local voltage measurements from designated load buses, controls online the reactive power generation of available synchronous generator (SG)-based and photovoltaic (PV)-based distributed generators (DGs). The distributed MFC strategy is computationally efficient and does not require modelling of the different system components and disturbances. Time-domain dynamic simulations are conducted for the 21-bus test distribution system fed by multiple DGs to verify the performance of the proposed MFC strategy, and the results are compared against the conventional model-based microgrid voltage stabilizer (MGVS) control strategy. The simulation results show that the distributed MFC strategy provides minimal voltage violations and achieves the dynamic voltage stability of the system under diverse disturbances.

Hatipoglu, Kenan↗

A real-time distributed solid oxide electrolysis cell (SOEC) model for cyber-physical simulation

System integration and dynamic operability between SOEC and balance-of-plant (BoP) components are major technical challenges before realizing rapid load following of SOEC systems. Cyber-physical simulation (CPS) is a leading-edge digital engineering approach and is regarded as the next step beyond Digital Twins. CPS approach can be used to research SOEC system integration and develop dynamic controls prior to actual pilot testing without using a real SOEC. To seamlessly couple with BoP hardware and access non-observable operational parameters (e.g., local temperature gradient) during transients, a distributed one-dimensional (1D) real-time SOEC model was developed. Its real-time execution was demonstrated for 20 to 640 nodes at the fixed time step of 5 ms. A higher excess air ratio enabled smaller local temperature gradients on SOEC solid materials and faster transients upon current density step change from 0.15 to 0.55 A cm -2 . During the transients, the magnitude of the peak temperature gradient nearly doubled in 10 s from -3.5 to -5.9 °C cm -1 . This represents a significant operating risk that can impact the dynamic operability of SOEC systems. In addition, the local temperature gradient was found to change directions on all nodes in SOEC solid materials, with the greatest impact on the upstream nodes. The SOEC model was also tested at the thermal neutral voltage using actual process air flow parameters as variable model inputs. Variable process air temperatures were found to induce alternating local temperature gradients on SOEC solid materials. These are new operational mechanisms for SOEC degradation relevant for load following operational modes yet distinct from previous reports. To mitigate these unfavorable features, the SOEC can be operated at voltages that are slightly (±20 mV) deviated from the thermal neutral voltage. Here, the corresponding net thermal energy change was less than 1.6% of the electric power consumption. This 1D real-time SOEC model established the basis of cyber-physical simulation of SOEC hybrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control methods for mitigating flow oscillations in a supercritical CO 2 recompression closed Brayton cycle

A dynamic model of a 10 MWe supercritical CO 2 (sCO 2 ) recompression closed Brayton power generation cycle is used to investigate control methods for mitigating oscillations in flow conditions and power demand load, especially as the load ramp rate is increased and the load setpoint is more closely tracked. The focus is on control of the main compressor inlet temperature (MCIT) since oscillations are prompted by the strong nonlinearities in sCO 2 fluid properties near the critical point and by changes in system inventory for efficient load management. In this study, the oscillatory behavior during load ramping is first shown and then two potential control solutions for substantially reducing oscillations are given: 1) the use of the main compressor inlet guide vanes (IGV) and 2) bypassing a portion of the sCO 2 around the cooler to maintain the MCIT. These control methods reduce the effect of cycle feedback from interactions between the MCIT and load. When implementing either control method, a load setpoint ramp of 7.5%/min was maintainable while achieving closer load setpoint tracking with limited oscillations. Finally, the impact of sensor noise on the control was examined since derivative action was used in the IGV and cooler sCO 2 bypass control. Finally, while some effect was evident, signal noise was not problematic to the control.

24 POWER TRANSMISSION AND DISTRIBUTION↗