Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “districts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Geographic and social disparities in exposure to air neurotoxicants at U.S. public schools

Highlights: • Ambient neurotoxicants pose serious risks at US public schools. • There are social and spatial disparities in ambient neurotoxicant risks. • One-third of all schools in EPA Region 2 are at “high risk” for neurotoxicant exposure. • Schools with higher % of Hispanic, black, and Asian students face disparate risks. • Schools serving the youngest (vs. older) students face disparate risks. Children are especially vulnerable to the health and developmental impacts of environmental hazards and they spend significant portions of their days at school. Yet there are no national-level studies examining school-level environmental inequalities and few have examined disparate exposure to neurological air toxicants, even though chronic exposure to air pollution impacts children's brain functioning. We paired information about the geographic locations and demographics of each public school in the US with air neurotoxicant exposure estimates pertaining to 24 known neurotoxicants included in the US Environmental Protection Agency's National Air Toxics Assessment. Using bivariate and multivariate statistics, we tested for environmental injustices in air neurotoxicant exposure at 84,969 US public schools. Metropolitan New York City (EPA Region 2) is the geographic region most burdened by air neurotoxicant exposures at schools since one-third of all schools in that region are in the top 10% (at {sup h}igh risk{sup )} for ambient neurotoxicant exposure among all schools nationwide. Students attending “high risk” public schools nationwide are significantly more likely to be eligible for free/reduced price meals, and to be Hispanic, black, or Asian/Pacific Islander (API). They are significantly less likely to be white or of another race. In a multivariate generalized estimating equation controlling for school district effects, schools with greater proportions of Hispanic, black, and API students, schools with higher enrollment, and schools located in more urban (vs. rural) counties face greater risks. Schools serving the youngest students (e.g., pre-kindergarten) have greater levels of risk than schools serving older students. Across all analyses, this study shows that racial/ethnic minority children are bearing the brunt of air neurotoxicant exposures at school, which may be unequally impacting their school performance and future potential.

54 ENVIRONMENTAL SCIENCES↗

Representativeness and repeatability of microenvironmental personal and head exposures to radio-frequency electromagnetic fields

Highlights: • First time assessment of head exposure to RF-EMF in uncontrolled environments, in 15 microenvironments in Melbourne, Australia. • We show that our measurement protocol is repeatable over time. • We show that the paths selected in our protocol are representative for the larger areas in which they are defined. • Exposure to RF-EMF is higher in more dense urban areas than in less populated suburban areas in the outskirts of the city. The aims of this study were to: i) investigate the repeatability and representativeness of personal radio frequency-electromagnetic fields (RF-EMFs) exposure measurements, across different microenvironments, ii) perform simultaneous evaluations of personal RF-EMF exposures for the whole body and the head, iii) validate the data obtained with a head-worn personal distributed exposimeter (PDE) against those obtained with an on-body worn personal exposimeter (PEM). Data on personal and head RF-EMF exposures were collected by performing measurements across 15 microenvironments in Melbourne, Australia. A body-worn PEM and a head-worn PDE were used for measuring body and head exposures, respectively. The summary statistics obtained for total RF-EMF exposure showed a high representativeness (r{sup 2} > 0.66 for two paths in the same area) and a high repeatability over time (r{sup 2} > 0.87 for repetitions of the same path). The median head exposure in the 900 MHz downlink band ranged between 0.06 V/m and 0.31 V/m. The results obtained during simultaneous measurements using the two devices showed high correlations (0.42 < r{sup 2} < 0.94). The highest mean total RF-EMF exposure was measured in Melbourne's central business district (0.89 V/m), whereas the lowest mean total exposure was measured in a suburban residential area (0.05 V/m). This study shows that personal RF-EMF microenvironmental measurements in multiple microenvironments have high representativeness and repeatability over time. The personal RF-EMF exposure levels (i.e. body and head exposures) demonstrated moderate to high correlations.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Air pollution and emergency department visits for respiratory diseases: A multi-city case crossover study

Highlights: • Extensive research exists on the effects of ambient air pollution on respiratory diseases. • Emergency department visits for respiratory diseases increase after days with higher concentrations of air pollution. • Ambient pollution, even at low concentrations, appear to adversely affect the respiratory system. Increasing evidence suggests that ambient air pollution is a major risk factor for both acute and chronic respiratory disease exacerbations and emergencies. The objective of this study was to determine the association between ambient air pollutants and emergency department (ED) visits for respiratory conditions in nine districts across the province of Ontario in Canada. Health, air pollutant (PM{sub 2.5}, NO{sub 2}, O{sub 3}, and SO{sub 2}), and meteorological data were retrieved from April 2004 to December 2011. Respiratory diseases were categorized as: chronic obstructive pulmonary disease (COPD, including bronchiectasis) and acute upper respiratory diseases. A case-crossover design was used to test the associations between ED visits and ambient air pollutants, stratified by sex and season. For COPD among males, positive results were observed for NO{sub 2} with lags of 3–6 days, for PM{sub 2.5} with lags 1–8, and for SO{sub 2} with lags of 4–8 days. For COPD among females, positive results were observed for O{sub 3} with lags 2–4 days, and for SO{sub 2} among lags of 3–6 days. For upper respiratory disease emergencies among males, positive results were observed for NO{sub 2} (lags 5–8 days), for O{sub 3}, (lags 0–6 days), PM{sub 2.5} (all lags), and SO{sub 2} (lag 8), and among females, positive results were observed for NO{sub 2} for lag 8 days, for O{sub 3}, PM{sub 2.5} among all lags. Our study provides evidence of the associations between short-term exposure to air pollution and increased risk of ED visits for upper and lower respiratory diseases in an environment where air pollutant concentrations are relatively low.

54 ENVIRONMENTAL SCIENCES↗

Modeling non-steady state radioisotope transport in the vadose zone--A case study using uranium isotopes at Pena Blanca, Mexico

Current models using U- and Th-series disequilibria to study radioisotope transport in groundwater systems mostly consider a steady-state situation. These models have limited applicability to the vadose zone (UZ) where the concentration and migratory behavior of radioisotopes in fluid are often transitory. We present here, as a first attempt of its kind, a model simulating the non-steady state, intermittent fluid transport in vadose layers. It provides quantitative constraints on in-situ migration of dissolved and colloidal radioisotopes in terms of retardation factor and rock-water interaction (or water transit) time. For uranium, the simulation predicts that intermittent flushing in the UZ leads to a linear relationship between reciprocal U concentration and {sup 234}U/{sup 238}U ratio in percolating waters, with the intercept and slope bearing information on the rates of dissolution and {alpha}-recoil of U isotopes, respectively. The general validity of the model appears to be borne out by the measurement of uranium isotopes in UZ waters collected at various times over a period during 1995-2006 from a site in the Pena Blanca mining district, Mexico, where the Nopal I uranium deposit is located. Enhanced {sup 234}U/{sup 238}U ratios in vadose-zone waters resulting from lengthened non-flushing time as prescribed by the model provide an interpretative basis for using {sup 234}U/{sup 238}U in cave calcites to reconstruct the regional changes in hydrology and climate. We also provide a theoretical account of the model's potential applications using radium isotopes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Role of agricultural activity on land subsidence in the San Joaquin Valley, California

The center of the San Joaquin Valley is one of the most productive agricultural regions in the US. Farmers rely heavily on surface-water diversions to meet irrigation water demand. However, the 2007–2010 and 2012–2017 droughts have caused strong increases in groundwater pumping causing land subsidence with strong variability in location, magnitude (total subsidence) and rate of subsidence. Here, in this study, we try to understand what caused these variations. We focus our analyses on three areas: (i) the Westland water district where subsidence was very small during the two drought periods, (ii) ‘El Nido’ area where the greatest subsidence rate was monitored from 2008 to 2010, and (iii) the’ Kings-Tulare counties’ area where the subsidence was small during the 2008–2010 and the largest during 2015–2017 droughts. Our main finding is that land subsidence is located in areas where the water demand for agriculture and the density of groundwater wells is the highest, whereas the rate of subsidence is strongly affected the amount of local and imported surface water and by groundwater resources. Based on these simple observations, we propose using continuous satellite-based ground deformation monitoring and geomechanical modeling to (i) localize areas most prone for future subsidence and (ii) to estimate and manage groundwater resources.

54 ENVIRONMENTAL SCIENCES↗

In situ dehydration behavior of zeolite-like pentagonite: A single-crystal X-ray study

The structural modifications upon heating of pentagonite, Ca(VO)(Si{sub 4}O{sub 10}){center_dot}4H{sub 2}O (space group Ccm2{sub 1}, a=10.3708(2), b=14.0643(2), c=8.97810(10) A, V=1309.53(3) A{sup 3}) were investigated by in situ temperature dependent single-crystal X-ray structure refinements. Diffraction data of a sample from Poona district (India) have been measured in steps of 25 up to 250 Degree-Sign C and in steps of 50 Degree-Sign C between 250 and 400 Degree-Sign C. Pentagonite has a porous framework structure made up by layers of silicate tetrahedra connected by V{sup 4+}O{sub 5} square pyramids. Ca and H{sub 2}O molecules are extraframework occupants. Room temperature diffraction data allowed refinement of H positions. The hydrogen-bond system links the extraframework occupants to the silicate layers and also interconnects the H{sub 2}O molecules located inside the channels. Ca is seven-fold coordinated forming four bonds to O of the tetrahedral framework and three bonds to extraframework H{sub 2}O. The H{sub 2}O molecule at O9 showing a high displacement parameter is not bonded to Ca. The dehydration in pentagonite proceeds in three steps. At 100 Degree-Sign C the H{sub 2}O molecule at O8 was released while O9 moved towards Ca. As a consequence the displacement parameter of H{sub 2}O at O9 halved compared to that at room temperature. The unit-cell volume decreased to 1287.33(3) A{sup 3} leading to a formula with 3H{sub 2}O per formula unit (pfu). Ca remained seven-fold coordinated. At 175 Degree-Sign C Ca(VO)(Si{sub 4}O{sub 10}){center_dot}3H{sub 2}O transformed into a new phase with 1H{sub 2}O molecule pfu characterized by doubling of the c axis and the monoclinic space group Pn. Severe bending of specific T--O--T angles led to contraction of the porous three-dimensional framework. In addition, H{sub 2}O at O9 was expelled while H{sub 2}O at O7 approached a position in the center of the channel. The normalized volume decreased to 1069.44(9) A{sup 3}. The Ca coordination reduced from seven- to six-fold. At 225 Degree-Sign C a new anhydrous phase with space group Pna2{sub 1} but without doubling of c had formed. Release of H{sub 2}O at O7 caused additional contraction of T--O--T angles and volume reduction (V=1036.31(9) A{sup 3}). Ca adopted five-fold coordination. During heating excursion up to 400 Degree-Sign C this anhydrous phase remained preserved. Between room temperature and 225 Degree-Sign C the unit-cell volume decreased by 21% due to dehydration. The dehydration steps compare well with the thermo-gravimetric data reported in the literature. - Graphical abstract: Pentagonite structure at room temperature and at 225 Degree-Sign C. Highlights: Black-Right-Pointing-Pointer We investigate the relationship between the removal of H{sub 2}O molecules and structural modifications of the framework of pentagonite. Black-Right-Pointing-Pointer Pentagonite undergoes phase transitions upon heating. Black-Right-Pointing-Pointer We analyze similarities and differences between pentagonite and related structures.

36 MATERIALS SCIENCE↗

Biofouling of filtration membranes in wastewater reuse: In situ visualization with confocal laser scanning microscopy

The filtration membranes utilized in advanced treatment of municipal wastewater are prone to biological fouling. Permeability loss and water recovery limitations due to fouling necessitate additional pretreatment and membrane cleaning, which raise the cost of water reuse. Better fouling mitigation calls for a deeper understanding of biofilm behavior on water reuse membranes. This study uses confocal microscopy to monitor biofouling under realistic conditions. To simulate water reuse, a miniature flow cell with microfiltration and ultrafiltration membranes was operated under typical filtration conditions using secondary effluent from California's East Bay Municipal Utility District. The growing biofilms were stained for extracellular polymeric substances and live and dead cells, and they were monitored in situ under filtration conditions with a confocal laser scanning microscope to produce 2-D and 3-D images. In situ image series revealed biofilm growth and removal processes including internal and external fouling, extracellular polymeric substance production, wrinkling, delamination, and film re-deposition. Additionally, changes in biofilm morphology between in situ and ex situ images highlighted limitations of ex situ imaging. Here, these results provide insight into the physical and biological mechanisms of biofouling in hopes of informing the development of improved techniques for biofouling mitigation.

ultrafiltration↗

Parametric study on maximum transportable distance and cost for thermal energy transportation using various coolants

The operation temperature of advanced nuclear reactors is generally higher than commercial light water reactors and thermal energy from advanced nuclear reactor can be used for various purposes such as district heating, desalination, hydrogen production and other process heat applications, etc. The process heat industry/facilities will be located outside the nuclear island due to safety measures. This thermal energy from the reactor has to be transported a fair distance. In this study, analytical analysis was conducted to identify the maximum distance that thermal energy could be transported using various coolants such as molten-salts, helium and water by varying the pipe diameter and mass flow rate. The cost required to transport each coolant was also analyzed. The coolants analyzed are molten salts (such as: KClMgCl2, LiF-NaF-KF (FLiNaK) and KF-ZrF4), helium and water. Fluoride salts are superior because of better heat transport characteristics but chloride salts are most economical for higher temperature transportation purposes. For lower temperature water is a possible alternative when compared with He, because low pressure He requires higher pumping power which makes the process very inefficient and economically not viable for both low and high temperature application.

42 ENGINEERING↗

The "Perfect Storm" for Distributed Wind Markets

Close to 1 GW of distributed wind has been installed across all 50 states, the District of Columbia, Puerto Rico, and the U.S. Virgin Islands. Yet the number of installations varies greatly by state, even when wind resources are similar. This article examines three key factors that over the past thirteen years have shown to be enablers of success for distributed wind installations in the United States: 1) favorable policy environments, including consistent incentives, administrative support for cutting through red tape, and favorable interconnection, net metering, and permitting policies; 2) high electricity prices that would be displaced by wind energy generation, and, 3) favorable wind resources, enabling steady production of energy. Not all conditions need to be met simultaneously, yet of the studied markets for distributed wind in Iowa, New York, Washington, and Oregon, the most successful ones exhibit at least two out of the three conditions mentioned. We describe steps that policymakers, regulators, and market players have taken in the past to increase distributed wind installations in the United States.

Foster, Nikolas AF↗

State-Level Trends in Renewable Energy Procurement via Solar Installation versus Green Electricity

In recent years, options for procuring renewable energy have increased, ranging from rooftop solar installation to utility green pricing to Community Choice Aggregation. These options vary in terms of costs and benefits to the consumer as well as grid integration implications. However, little is known regarding how the presence of a wide range of voluntary utility-scale renewable procurement options as well as their growth could affect adoption of distributed residential solar. To examine this relationship, we fit a two-stage least squares random effects regression model on panel data from 2016 to 2019 for all fifty US states plus the District of Columbia, controlling for variables that measure state-level policies, economic factors, and resource availability. Although there was no evidence of a strong relationship between demand for utility-scale and distributed options across all states, the state-level correlations suggest a wide variation between states including a positive, zero or negative relationship between utility-scale and distributed generation.

consumer demand↗

Field-scale dynamics of planting dates in the US Corn Belt from 2000 to 2020

Crop planting dates are a dynamic feature of agricultural systems that respond to short- and long-term climate signals, crop and cultivar selection, and technology changes. Planting date records are essential for yield gap analyses, accurate crop modeling, and tracking farmer adaptations to weather and climate change. Although planting dates have high variation at local scales due to heterogeneity in farm resources and decision-making, available long-term data on planting dates is largely restricted to aggregated regional statistics or, at best, satellite-derived datasets with limited spatiotemporal extent and at resolutions unable to distinguish individual fields (> 250 m). Here, we generated retrospective annual field-scale (30 m) planting date maps for both maize and soybeans spanning 2000-2020 across a 12 state region in the United States Corn Belt based on Landsat satellite data and a large ground sample of over 28,000 maize and soybean fields. Using training data from 2015-2020 for model selection, we found that planting date predictions improved with harmonic regression of Landsat data and additional annual weather covariates. The preferred random forests model approximately doubled performance compared to a null model based on state median planting dates, capturing 47% of field-level variation for maize (mean absolute error, MAE = 7.4 days) and 44% for soybeans (MAE = 7.5 days) against held-out ground truth test data for 2008-2014. We also evaluated the full 2000-2020 dataset with state agricultural statistics, finding strong agreement with median planting dates for maize (R 2 = 0.76, MAE = 4.4 days) and slightly lower agreement for soybeans (R 2 = 0.65, MAE = 5.4 days) when aggregated to the state level. We then used this new dataset to analyze environmental determinants of planting dates at a finer-scale than previously possible, controlling for unobserved variation at the sub-state district level. We found that during 2000-2020, each standard deviation increase in rainfall delayed planting by ~ 2.5 days, and fields with higher soil productivity ratings tended to be planted earlier. We did not find meaningful trends over the last two decades in planting dates for maize or soybeans, in contrast to trends towards earlier planting dates late last century and predicted for this period in climate adaptation studies. We hypothesize increases in early season rainfall may have inhibited these shifts towards earlier planting. Remotely sensed planting dates will be a useful tool for yield gap analyses, crop simulation modeling, and ongoing assessment of climate adaptation.

54 ENVIRONMENTAL SCIENCES↗

Pathways of clean energy heating electrification programs for reducing carbon emissions in Northwest China

We report clean energy heating electrification programs provide a promising way to reduce carbon emissions from fossil fuel combustion and consumption. This work studies the cost competitiveness of clean energy heating technologies under three dynamic mechanisms: investment costs, subsidy policies, and operating costs with real data. It provides key insights into the cost competitiveness of the different heating technologies deployed in different areas, as well as their sensitivity to the three dynamic mechanisms. The results show that currently, the distinct heating programs are more cost-efficient in the urban area with existing heating networks. The average payback period of all district clean energy heating programs in the urban area is 14.9 years, while that of the individual clean heating programs is 24.7 years. The individual heating programs are becoming increasingly cost-competitive with the incentive mechanisms, especially the electricity pricing mechanisms. Moreover, individual heating technologies present remarkable advantages on flexibility and sustainability in the long run. According to the technology diffusion model proposed in this paper, the individual clean heating programs will occupy more than 50% of the market share in 2050 under the comprehensive effect of CAPEX, government subsidies, and OPEX. The real-world results and analysis render references to shape the pathway of clean energy heating electrification in Northwest China and other regions with a similar situation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Defining weather scenarios for simulation-based assessment of thermal resilience of buildings under current and future climates: A case study in Brazil

In response to increasingly severe weather conditions, optimization of building performance and investment provides an opportunity to consider co-benefits of thermal resilience during energy efficiency retrofits. This work aims to assess thermal resilience of buildings using building performance simulation to evaluate the indoor overheating risk under nine weather scenarios, considering historical (2010s), mid-term future (2050s), and long-term future (2090s) typical meteorological years, and heat wave years. Such an analysis is based on resilience profiles that combine six integrated indicators. A case study with a district of 92 buildings in Brazil was conducted, and a combination of strategies to improve thermal resilience was identified. Results reflect the necessity of planning for resilience in the context of climate change. This is because strategies recommended under current conditions might not be ideal in the future. Therefore, an adaptable design should be prioritized. Cooling energy consumption could increase by 48 % by the 2050s, while excessive overheating issues could reach 37 % of the buildings. Simple passive strategies can significantly reduce the heat stress. A comprehensive thermal resilience analysis should ultimately be accompanied by a thorough reflection on the stakeholders’ objectives, available resources, and planning horizon, as well as the risks assumed for not being resilient.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Variation in microbial community structure correlates with heavy-metal contamination in soils decades after mining ceased

Microorganisms play vital roles in Earth's biogeochemical cycles. Identifying disturbances in microbial communities due to anthropogenic contamination can provide insights into the health of ecosystems. Picher, Oklahoma, was the site of large-scale mining operations for Pb, Zn, and other heavy metals until the mid-1950s, operating within the Tri-State Mining District (TSMD) of Missouri, Kansas and Oklahoma. Although mining ceased decades ago, high concentrations of heavy metals (>1000 ppm) remain in area soil and water systems. Previously, we mapped metal concentrations on samples collected from mine tailings in Picher and along cardinal-direction transects within an 8.05-km radius of the town. To elucidate changes in microbial community structure due to regional metal contamination, 16S rRNA gene sequences and qPCR calculations of total Bacteria and Archaea were analyzed against these metal concentrations. Bacteria were negatively and significantly correlated with Pb, Cd, Zn, and Mg; however, Archaea was only significantly and positively correlated with pH. Illumina sequencing of 16S rRNA genes showed significant differences in microbial communities of chat and west transect samples. Comparison of soil chemistry with community structure indicated that Al, Pb, Cd, and Zn significantly impacted community composition and distribution of individual OTUs. Mapping the distribution of heavy-metal contamination and microbial communities in these soils represents the first step in understanding effects of long-term, heavy-metal contamination at a basic trophic level.

59 BASIC BIOLOGICAL SCIENCES↗

Not according to the high court, Professor Wolak

The FERC and its powers and actions related to ''just and reasonable'' prices are discussed in the aftermath of the California crisis. The decision in the case Morgan Stanley Capital Group Inc. v. Public Utility District No. 1 of Snohomish County et al. is addressed. The author concludes, FERC has an absolutely vital role to play in fulfilling its obligations under the FPA and in fostering a system that creates ''just and reasonable'' prices. It must certify markets that will be sufficiently competitive to allow market prices to become set. It must continually monitor those markets to ensure that competitive conditions are met. It must enforce prohibitions against fraud and market manipulation. But if it does those things, it is entitled under the FPA to certify the prices thus generated as ''just and reasonable.'' And the justification is the long-run welfare of consumers, exactly the group the FPA was enacted to protect.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

On the evaluation and selection of network-level traffic control policies: Perimeter control, TUC, and their combination

Perimeter control (PC) of urban traffic networks can be effective in increasing network-wide efficiency. PC operates on the border of a protected region of a traffic network. Most studies thus far considered fixed-time plans for the inner part of these regions. A few studies have shown that combining PC with locally actuated or decentralized traffic control systems may have positive effects on traffic performance, including better-defined Network Macroscopic Fundamental Diagrams (NMFDs), increased network throughput, and reduced delays. The Traffic-responsive Urban Control (TUC) is a real-time network-wide traffic control system with particular design characteristics, such as the balancing of link's occupancies and an inherent gating feature. These characteristics suggest that TUC may enhance the traffic network performance when combined with PC whilst improving the resulting NMFDs and network throughput and delays. Here, in this work, we investigate the effect of feedback perimeter control (FPC), TUC, and their combination on the NMFD and on the traffic conditions of general traffic and public transport in the microsimulation of a realistic model of the Christchurch Central Business District in New Zealand. We perform a thorough investigation of practical aspects of both control strategies and their combination, including parameter tuning and infrastructure requirements, and how they may affect the control system choice. Results show higher throughput and less hysteresis on the NMFDs, particularly when TUC is involved. PC provides benefits concentrated in the protected region which can greatly benefit public transportation if there is an overlap with the transit network. The combination of TUC and FPC boosts network-wide throughput.

33 ADVANCED PROPULSION SYSTEMS↗

Characteristics of healthcare wastes

A comprehensive understanding of the quantities and characteristics of the material that needs to be managed is one of the most basic steps in the development of a plan for solid waste management. In this case, the material under consideration is the solid waste generated in healthcare facilities, also known as healthcare waste. Unfortunately, limited reliable information is available in the open literature on the quantities and characteristics of the various types of wastes that are generated in healthcare facilities. Thus, sound management of these wastes, particularly in developing countries, often is problematic. This article provides information on the quantities and properties of healthcare wastes in various types of facilities located in developing countries, as well as in some industrialized countries. Most of the information has been obtained from the open literature, although some information has been collected by the authors and from reports available to the authors. Only data collected within approximately the last 15 years and using prescribed methodologies are presented. The range of hospital waste generation (both infectious and mixed solid waste fractions) varies from 0.016 to 3.23 kg/bed-day. The relatively wide variation is due to the fact that some of the facilities surveyed in Ulaanbaatar include out-patient services and district health clinics; these facilities essentially provide very basic services and thus the quantities of waste generated are relatively small. On the other hand, the reported amount of infectious (clinical, yellow bag) waste varied from 0.01 to 0.65 kg/bed-day. The characteristics of the components of healthcare wastes, such as the bulk density and the calorific value, have substantial variability. This literature review and the associated attempt at a comparative analysis point to the need for worldwide consensus on the terms and characteristics that describe wastes from healthcare facilities. Such a consensus would greatly facilitate comparative analyses among different facilities, studies and countries.

54 ENVIRONMENTAL SCIENCES↗