Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “direct detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Detector verifier for circuit analyzers

Economical tool checks operation of automatic circuit analyzer. Each loop is addressed directly from analyzer console by switching internal analyzer bridge to resistance equal that of connecting cable plus specified limiting test value. Procedure verifies whether detected faults in circuit under test are actually due to analyzer malfunction. Standard-length universal test cables make it possible to shift detector tool from cable to cable without resistance compensation.

Pope, D. L.↗

Nonscanning climate sensor study

The Nonscanning Climate Sensor represents a new instrument for climate research and global monitoring of the earth radiation budget. It contains a mosaic of array of detectors which measures the outgoing radiation of the earth in all directions without the need for mechanical scanning. The goal is to eliminate all moving parts and obtain highly calibrated measurements for up to one solar cycle (11 years) without being susceptible to mechanical failure. Over set intervals of time, the angular measurements are integrated up to produce total reflected and emitted flux values from each target area on the Earth. To achieve the require sensitivity while maintaining a flat spectral response, an improved dual cavity detector with digital control loop was developed. The detector is self calibrating to maintain high precision over the life of the instrument. Prototype detectors and a complete set of electronics with a microprocessor controller were fabricated and tested. Measurements show that the new detectors are more than an order of magnitude more sensitive than previous versions.

Hoffman, James W.↗

Cosmogenic background rejection for the sterile neutrino search with the Short-Baseline Neutrino Program Far Detector

As the Short-Baseline Neutrino Program Far Detector, the ICARUS liquid argon time-projection chamber will operate at shallow depth and therefore be exposed to the full surface flux of cosmic rays. This poses a problematic background to the sterile neutrino search. A direct way to reject this background is to surround the cryostat with a detector capable of tagging incident cosmic muons with high efficiency, the Cosmic Ray Tagging System (CRT). I have worked to develop the CRT detector hardware and the simulation and reconstruction software. This system, currently undergoing installation, is approximately 25% commissioned and taking data. I have developed a powerful method for cosmogenic background rejection utilizing the CRT and Photon Detection System. Results from a simulation based study, informed by CRT data, demonstrate the power of the technique in rejecting cosmogenic events with little adverse impact on the neutrino sample.

Hilgenberg, Christopher Michael↗

A gamma ray monitor for the OSO-7 spacecraft

A 3 in. x 3 in. NaI(Tl) gamma ray (0.3 to 10 MeV) spectrometer with a CsI(Na) charged particle and anti-Compton shield has been developed for the Orbiting Solar Observatory (OSO-7) which was launched September 30, 1971. The instrument, designed for a rotating wheel compartment, utilizes a 377 channel quadratic PHA with accumulation times of 3, 1, or 0.5 minutes. Quick look and calibration data obtained via a direct data link to a minicomputer allows near real time monitoring and control of the experiment. Various commands changing the operating mode can be executed. The functions which can be commanded include: rotation of the quadrants in which data is collected by 90 deg; gain adjustment of the central detector over a 6:1 range; manual or automatic sequencing of calibrations; variations of accumulation times by telemetering selected channels; and selection of reference directions. A small X-ray detector covering the range 7.5 to 120 keV is also included.

Higbie, P. R.↗

Infrared and Reflected Solar Radiation Measurements from the TIROS 2 Meteorological Satellite

TIROS II contains instrumentation for measuring infrared and reflected solar radiation from the earth and its atmosphere. A medium resolution scanning radiometer and a low resolution non-scanning radiometer are employed. The satellite's spin provides the scan line of the medium resolution radiometer which is then advanced by the orbital motion. The spatial resolution is about 40 miles square when the earth directly beneath the satellite is viewed. The five channels employ bolometer detectors and filters to limit the spectral responses to five bands: 6 to 6.5 microns, 8 to 12 microns, 0.2 to 6 microns, 8 to 30 microns, and 0.55 to 0.75 microns. These five bands study, respectively: radiation in the water vapor absorption band; day and nighttime cloud cover; albedo; thermal radiation; and visual maps for comparison with satellite vidicon pictures. The low resolution non-scanning radiometer measures the earth's black-body temperature and albedo. Its field when viewing directly below is a circle of 450 miles diameter, covering part of each frame from the wide-field television camera. This radiometer consists of two thermistors, each in the apex of a reflective cone which provides optical gain. One thermistor is black and responds to both thermal and reflected solar radiation. The second responds to thermal but reflects solar radiation. The design, calibration, performance, and data reduction for both systems are discussed herein.

Bandeen, W. R.↗

Phase-Shifted Laser Feedback Interferometry

Phase-shifted, laser feedback interferometry is a new diagnostic tool developed at the NASA Lewis Research Center under the Advanced Technology Development (ATD) Program directed by NASA Headquarters Microgravity Research Division. It combines the principles of phase-shifting interferometry (PSI) and laser-feedback interferometry (LFI) to produce an instrument that can quantify both optical path length changes and sample reflectivity variations. In a homogenous medium, the optical path length between two points is the product of the index of refraction and the geometric distance between the two points. LFI differs from other forms of interferometry by using the laser as both the source and the phase detector. In LFI, coherent feedback of the incident light either reflected directly from a surface or reflected after transmission through a region of interest will modulate the output intensity of the laser. The combination of PSI and LFI has produced a robust instrument, based on a low-power helium-neon (HeNe) gas laser, with a high dynamic range that can be used to measure either static or oscillatory changes of the optical path length. Small changes in optical path length are limited by the fraction of a fringe that can be measured; we can measure nonoscillatory changes with a root mean square (rms) error of the wavelength/1000 without averaging.

Ovryn, Benjie↗

Coherent Detection of High-Rate Optical PPM Signals

A method of coherent detection of high-rate pulse-position modulation (PPM) on a received laser beam has been conceived as a means of reducing the deleterious effects of noise and atmospheric turbulence in free-space optical communication using focal-plane detector array technologies. In comparison with a receiver based on direct detection of the intensity modulation of a PPM signal, a receiver based on the present method of coherent detection performs well at much higher background levels. In principle, the coherent-detection receiver can exhibit quantum-limited performance despite atmospheric turbulence. The key components of such a receiver include standard receiver optics, a laser that serves as a local oscillator, a focal-plane array of photodetectors, and a signal-processing and data-acquisition assembly needed to sample the focal-plane fields and reconstruct the pulsed signal prior to detection. The received PPM-modulated laser beam and the local-oscillator beam are focused onto the photodetector array, where they are mixed in the detection process. The two lasers are of the same or nearly the same frequency. If the two lasers are of different frequencies, then the coherent detection process is characterized as heterodyne and, using traditional heterodyne-detection terminology, the difference between the two laser frequencies is denoted the intermediate frequency (IF). If the two laser beams are of the same frequency and remain aligned in phase, then the coherent detection process is characterized as homodyne (essentially, heterodyne detection at zero IF). As a result of the inherent squaring operation of each photodetector, the output current includes an IF component that contains the signal modulation. The amplitude of the IF component is proportional to the product of the local-oscillator signal amplitude and the PPM signal amplitude. Hence, by using a sufficiently strong local-oscillator signal, one can make the PPM-modulated IF signal strong enough to overcome thermal noise in the receiver circuits: this is what makes it possible to achieve near-quantum-limited detection in the presence of strong background. Following quantum-limited coherent detection, the outputs of the individual photodetectors are automatically aligned in phase by use of one or more adaptive array compensation algorithms [e.g., the least-mean-square (LMS) algorithm]. Then the outputs are combined and the resulting signal is processed to extract the high-rate information, as though the PPM signal were received by a single photodetector. In a continuing series of experiments to test this method (see Fig. 1), the local oscillator has a wavelength of 1,064 nm, and another laser is used as a signal transmitter at a slightly different wavelength to establish an IF of about 6 MHz. There are 16 photodetectors in a 4 4 focal-plane array; the detector outputs are digitized at a sampling rate of 25 MHz, and the signals in digital form are combined by use of the LMS algorithm. Convergence of the adaptive combining algorithm in the presence of simulated atmospheric turbulence for optical PPM signals has already been demonstrated in the laboratory; the combined output is shown in Fig. 2(a), and Fig. 2(b) shows the behavior of the phase of the combining weights as a function of time (or samples). We observe that the phase of the weights has a sawtooth shape due to the continuously changing phase in the down-converted output, which is not exactly at zero frequency. Detailed performance analysis of this coherent free-space optical communication system in the presence of simulated atmospheric turbulence is currently under way.

Vilnrotter, Victor↗

A Solenoid With Partial Yoke for the Dune Near Detector

The Deep Underground Neutrino Experiment (DUNE) at Fermilab is one the most challenging next-generation experiments in the field of neutrino physics. It will feature two detectors for a detailed study of neutrino oscillations using an unprecedentedly intense neutrino beam. The two detectors are a Near Detector located on the Fermilab site, 574 m away from the neutrino generation, and a Far Detector in South Dakota, 1300 km away. The Near Detector consists of three subdetectors, based on different technologies in order to achieve the best understanding of the neutrino beam. One key element of the Near Detector is a High Pressure Argon TPC surrounded by a calorimeter. This detector will need a 0.5 Tesla magnetic field transverse to the neutrino beam direction, with a 7 m diameter, 8 m long warm bore. A thin superconducting solenoid with a partial yoke, needed in order to minimise the amount of material along the path particles take crossing the different elements of the Near Detector is proposed. In this paper we present a detailed magnetic analysis and a preliminary study of the cooling, the cable and the mechanics for this magnet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical multi-species gas monitoring sensor and system

The system includes at least one light source generating light energy having a corresponding wavelength. The system's sensor is based on an optical interferometer that receives light energy from each light source. The interferometer includes a free-space optical path disposed in an environment of interest. The system's sensor includes an optical device disposed in the optical path that causes light energy of a first selected wavelength to continue traversing the optical path whereas light energy of at least one second selected wavelength is directed away from the optical path. The interferometer generates an interference between the light energy of the first selected wavelength so-traversing the optical path with the light energy at the corresponding wavelength incident on the optical interferometer. A first optical detector detects the interference. At least one second detector detects the light energy at the at least one second selected wavelength directed away from the optical path.

Polzin, Kurt A.↗

A Deposited Magnetic Thermometer for Temperatures below 0.1 Kelvin

Magnetic thermometers are much less sensitive to self-heating due to rf noise than are traditional resistive thermometers. This makes them appealing at temperatures well below 0.1 Kelvin in the operating range of many space-flight detectors. We have developed and tested a magnetic thermometer which is deposited directly onto a substrate. This device, which uses the temperature dependence of iron-doped palladium's magnetic susceptibility, includes self-shielding deposited coils surrounding a sputtered palladium layer. It is read out using a SQUID to achieve high resolution. Its small size and perfect heat sinking should make it useful for the temperature control of space flight detector arrays, in particular those already using SQUID readouts. The design and test results for this device are discussed.

Tuttle, J. G.↗

Application of upconversion detection to pulsed CO2 lidar

In this paper the application of an upconversion detector to pulsed CO2 lidar is investigated. In this device a nonlinear IR crystal would be used to convert 10-micron lidar radiation into the visible region for conventional detection with a photomultiplier tube. A pulsed CO2 lidar can be substantially improved with an upconversion detector configured for rejection of thermal background radiation using a narrowband filter for the upconverted signal or a cold filter front end. The sensitivity of the upconversion detector with the narrowband visible wavelength filter is estimated to be 2 orders of magnitude better than that of the usual direct detection diode. The cold filter can improve upconversion detection to nearly the signal-shot limit. These upconversion detectors are not limited by speckle noise as is a pulsed heterodyne detector.

Itabe, T.↗

Gravitational memory and Ward identities in the local detector frame

Gravitational memory, which describes the permanent shift in the strain after the passage of gravitational waves, is directly related to Weinberg’s soft graviton theorems and the Bondi-Metzner-Sachs (BMS) symmetry group of asymptotically flat space-times. In this work, we provide an equivalent description of the phenomenon in local coordinates around gravitational wave detectors, such as transverse-traceless (TT) gauge. We show that gravitational memory is encoded in large residual diffeomorphisms in this gauge, which include time-dependent anisotropic spatial rescalings, and prove their equivalence to BMS transformations when translated to TT gauge. We then derive the associated Ward identities and associated soft theorems, for both scattering amplitudes and equal-time (in-in) correlation functions, and explicitly check their validity for planar gravitational waves. Furthermore, the in-in identities are recognized as the flat-space analog of the well-known inflationary consistency relations.

General relativity↗

Field deployable trace radioisotope analysis through combined electrochemical and alpha spectroscopy methods

A method for depositing actinides directly onto a 4H-SiC Schottky barrier diode (SBD) detector as a field deployable actinides sensor was developed to enable off-site analysis, shortening the time to obtain critical information such as elements, concentration, and/or isotopic ratio related to the radiological situation. A thin film of Hg was first electrodeposited onto the Pt contact of the SiC diode, followed by chronoamperometric deposition of microgram levels of actinides under conventional control conditions. The 4H-SiC diode maintained consistent functionality through the electrodeposition process and showed resolved alpha-energy spectra that contained accurate isotopic information demonstrating the feasibility of a combined chemical and radiological sensor for field actinide detection and quantification.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Measurements of DC SQUID Damping Effects on Superconducting Resonant Circuits

Here, we present experimental measurements of SQUID-induced damping effects on strongly coupled, lumped-element resonators in the 500kHz–1 MHz frequency range. While dc SQUIDs are commonly used for sensitive readout of electromagnetic signals such as in lumped-element axion dark matter searches, coupling a dc SQUID to a resonant circuit modifies the circuit's resonance frequency, quality factor, noise, and impedance. These parameters have a direct impact on the science reach of axion dark matter detectors, making it important to understand SQUID damping contributions. We describe a helium dip probe and two-stage SQUID readout scheme used to probe SQUID damping effects. Measurements from this setup inform the design and operation of both future test platforms as well as next-generation dark-matter experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrated photonic Galton board and its application for photon counting

The Galton board is a desktop probability machine traditionally used to visualize the principles of statistical physics from classical particles. Here, we demonstrate a photonic Galton board that enables on-chip observation of statistics from single-photon interference. The photonic Galton board consists of a directional coupler matrix terminated by an array of superconducting nanowire detectors to provide spatiotemporal resolution. This design also allows for photon-number-resolving capability, making it suitable for high-speed photon counting. Our results demonstrate the compatibility between single-photon detector array and photonic integrated circuits, paving the way for implementing on-chip large-scale quantum optics experiments and photonic quantum computing.

Qin, Hezheng (ORCID:0009000139348800)↗

Light Meson Spectroscopy with GlueX and Beyond

The GlueX experiment at Jefferson Lab was specifically designed for precision studies of the light-meson spectrum. For this purpose, a photon beam with energies up to 12 GeV is directed onto a liquid hydrogen target contained within a hermetic detector with near-complete neutral and charged particle coverage. Linear polarization of the photon beam with a maximum around 9 GeV provides additional information about the production process. In 2018, the experiment completed its first phase, recording data with a total integrated luminosity above 400 pb?1. We highlight a selection of results from this world-leading data set with emphasis on the search for light hybrid mesons. In the mean time, the detector underwent significant upgrades and is currently recording data with an even higher luminosity. The future plans of the GlueX experiment to explore the meson spectrum with unprecedented precision are summarized.

Austregesilo, Alexander↗

Physics Flash Winter 2021 [Newsletter]

The Winter 2021 quarterly newsletter highlights articles titled "Putting down new markers for Los Alamos neutrino research", Direct measurements of nuclear reactions on radionuclides", Novel thermal neutron detector safeguards aircraft, HPC semiconductor electronics", along with the usual standard sections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Rapid Acceleration of Outcomes in Physics: Final Report for the Nuclear Physics, Particle Physics, Astrophysics, and Cosmology (NPAC) Umbrella Project

The Nuclear Physics, Particle Physics, Astrophysics, and Cosmology (NPAC) Initiative addresses the first question by supporting experiments that would directly detect dark matter when it interacts with very sensitive detectors. There are two leading candidates for dark matter that are plausibly detectable in terrestrial searches: axions and weakly-interacting massive particles, or WIMPs. Early NPAC investments supported PNNL involvement in the Axion Dark Matter eXperiment (ADMX), which has produced the world’s most sensitive axion search to date. Work associated with the current generation of the experiment is funded by the DOE Office of High Energy Physics (HEP), while R&D toward future searches for higher mass axions proceeds under NPAC. Likewise, early NPAC support for WIMP searches has graduated to the HEP-supported Super Cold Dark Matter Search (SuperCDMS) experiment. SuperCDMS has produced world-leading limits on potential WIMP candidates as well as a number of other exotic candidates and processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗