Advanced technical developments in support of scientific experiments in space

A technique was developed for preparing solid state, lithium-drifted silicon detectors. Hollow cylindrical detectors were built and tested for possible use as anticoincidence shields to replace conventional plastic scintillators and photomultipliers. A fission cell was developed for the Pioneer F/G instruments and the IMP I subsystem. An electron current detector was developed for Jovian belt measurements of electron flux. A number of circuits and semiconductor devices was also developed.

Lamport, J. E.↗

Accurate electromagnetic modeling of terahertz detectors

Twin slot antennas coupled to superconducting devices have been developed over the years as single pixel detectors in the terahertz (THz) frequency range for space-based and astronomy applications. Used either for mixing or direct detection, they have been object of several investigations, and are currently being developed for several missions funded or co-funded by NASA. Although they have shown promising performance in terms of noise and sensitivity, so far they have usually also shown a considerable disagreement in terms of performance between calculations and measurements, especially when considering center frequency and bandwidth. In this paper we present a thorough and accurate electromagnetic model of complete detector and we compare the results of calculations with measurements. Starting from a model of the embedding circuit, the effect of all the other elements in the detector in the coupled power have been analyzed. An extensive variety of measured and calculated data, as presented in this paper, demonstrates the effectiveness and reliability of the electromagnetic model at frequencies between 600 GHz and 2.5THz.

Hot Electron Bolometer (HEB)↗

A method to improve observations of gamma-ray sources near 10 (15) eV

Now that sources of gamma rays near 10 to the 15th power eV have been identified, there is a need for telescopes which can study in detail the high energy gamma ray emissions from these sources. The capabilities of a Cerenkov detector which can track a source at large zenith angle (small elevation angle) are analyzed. Because the observed showers must then develop far from the detector, the effective detection area is very large. During a single half-hour hot phase of Cygnus X-3, for example, it may be possible to detect 45 signal showers compared with 10 background showers. Time structure within the hot phase may then be discernible. The precise capabilities of the detector depend on its mirror size, angular acceptance, electronic speed, coincidence properties, etc. Calculations are presented for one feasible design using mirrors of an improved Fly's Eye type.

Sommers, P.↗

Development of readout electronics for the CMS ME0 muon detector

The Large Hadron Collider (LHC) in the High Luminosity (HL-LHC) era will be upgraded to deliver instantaneous luminosities up to 5 X 10 34 cm -2 s -1 , five times more than the original design value. In order to maintain performance of the Compact Muon Solenoid (CMS) Experiment under these conditions, ME0 is one of the new muon detectors to be added, along with GE1/1, GE2/1, RE3/1 and RE4/1. ME0 uses the triple Gas Electron Multiplier (GEM) technology and is designed to cover the far-forward region of 2.0 < |η| < 2.8. Further, the readout electronics for ME0 must be designed to deal with high data rates and be sufficiently radiation hard to operate very close to the beamline. The design and development status of the readout electronics for ME0 are presented, along with recent results from integration tests performed using the latest electronics prototypes with GEM chambers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microcalorimetry: The First Two Decades

Our group at GSFC began experimental and theoretical work on microcalorimetry almost twenty years ago, in August of 1982. Over the next 10 months, we completed the initial demonstration of a Si impurity thermometer-based calorimeter as an X-ray spectrometer. This successful demonstration resulted in the development by many investigators of scientific applications for microcalorimeters, ranging from optical spectroscopy to dark matter detection to particle physics applications. Many new technical approaches for cryogenic detectors were proposed by investigators and have been developed. In this presentation, I will describe the early development of microcalorimeters at GSFC and University of Wisconsin and the subsequent rapid growth of this work around the world The key milestones in the early development were the initial spectroscopy demonstrations and the selection of XRS, our microlcalorimeter-based instrument for the Advanced X-ray Astrophysics Facility (AXAF) and ultimately for ASTRO-E. An additional key event was the development of the direct detection of dark matter experiment and the formation of the Center for Particle Astrophysics. Both of these programs provided long term support for this technology in its precarious early days. A major additional technical step in the development of detectors was the demonstration of devices based on superconducting transition edge sensors (TES). These detectors promised (and have delivered) improved energy resolution and higher event rate capabilities. They couple naturally to SQUIDS, which operate well at the low temperatures where the detectors must operate. The past two decades have taken microcalorimeters from their infancy to applications in real experiments. I will provide an overview of the early development of the devices and review the breadth of the present technology and applications.

Moseley, Harvey↗

Analysis of PNAR Spent Fuel Safeguards Measurements using the ORIGEN Data Analysis Module

This paper summarizes the analysis of the Passive Neutron Albedo Reactivity (PNAR) measurements using the ORIGEN data analysis module for 23 boiling water reactor spent fuel assemblies that were performed in Finland under an international collaboration on spent fuel safeguards verification methods. PNAR is part of the proposed integrated nondestructive system to be used for safeguards verifications at the planned Finnish encapsulation facility. Besides measuring passive neutron and gamma emission rates from an assembly like a Fork detector, PNAR also measures the PNAR ratio, which is expected to correlate with the fissile content in the assembly. The emission rates and PNAR ratio can be used to verify the operator declarations and the fissile content of an assembly, respectively. The analysis was performed using the ORIGEN Data Analysis Module, which was originally developed for predicting Fork detector neutron and gamma signals for spent fuel measurements and has been integrated into the Integrated Review and Analysis Package developed by Euratom and the IAEA. The Module includes the ORIGEN burnup analysis code and integrates detector response functions pre-generated using MCNP to predict detector signals in several seconds per assembly. In this study, new response functions specific to PNAR measurements were generated for ORIGEN Module. The study also analyzes impacts of using detailed fuel design and operation information vs. standard safeguards information on results calculated by ORIGEN Module. Using detailed information reduced the standard deviation of relative differences between calculated and measured neutron count rates among the 23 assemblies from ~10% to ~4%. The results obtained using standard safeguards information for these PNAR measurements were similar to those obtained for the Fork detector. A clear trend was found between the calculated net neutron multiplications and the measured PNAR ratios of the 23 assemblies. This paper describes how ORIGEN Module calculates the expected PNAR neutron and gamma signals and PNAR ratio and how they compare with corresponding measured values.

Ilas, Germina↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Infrared Camera

A sensitive infrared camera that observes the blazing plumes from the Space Shuttle or expendable rocket lift-offs is capable of scanning for fires, monitoring the environment and providing medical imaging. The hand-held camera uses highly sensitive arrays in infrared photodetectors known as quantum well infrared photo detectors (QWIPS). QWIPS were developed by the Jet Propulsion Laboratory's Center for Space Microelectronics Technology in partnership with Amber, a Raytheon company. In October 1996, QWIP detectors pointed out hot spots of the destructive fires speeding through Malibu, California. Night vision, early warning systems, navigation, flight control systems, weather monitoring, security and surveillance are among the duties for which the camera is suited. Medical applications are also expected.

Source record↗

PSEC5 Physical Verification

Ultra-Fast timing detectors, having a time resolution of 10pSec or less, are becoming increasingly important for many scientific disciplines, including High Energy Physics, Nuclear Physics, Medical Imaging and more. When developing ultra-fast detectors such as MCPs, LAPPDs, LGADs, SNSPDs, it is necessary to have access to a readout system that is low power, can support many channels and is cost effective. The PSEC5 chip was an application specific integrated circuit (ASIC) developed by the pioneering group of Prof. Henry Frisch at University of Chicago and micro electronic engineers at Fermi National Accelerator Laboratory. Three boards were designed, two to implement the readout system for an LAPPD and one to only characterize the PSEC1 chip. The main goal of the project shifted to setting up a testing environment to focus on the characterization of the chip. My student and I tested and characterized this ASIC using the third chip-on-board printed circuit board. Results show the successful fabrication and operation of some of the key building blocks and lead to the suggestions on modification for the second iteration of the chip.

Rico Aniles, H. D. [Unlisted]↗

Report from: US Muon Workshop 2021: A Road Map for a Future Muon Facility February 1-2, 2021

The workshop titled “US Muon Workshop 2021: A road map for a future Muon Facility” was held virtually on February 1-2, 2021. The workshop aimed to bring together world experts in muon spectroscopy (µSR) and other techniques along with interested stakeholders to evaluate the scientific need to construct a new µSR facility in the United States (US). The more than 200 participants highlighted several key scientific areas for µSR research, including quantum materials, hydrogen chemistry, and battery materials, and how each area could benefit from a new, high flux pulsed muon source. Experts also discussed aspects of the µSR technique, such as low-energy µSR, novel software developments, and beam and detector technologies that could enable revolutionary advances in µSR at a next-generation facility. The workshop concluded with discussion of a concept being developed for a new µSR facility at the Spallation Neutron Source (SNS) of Oak Ridge National Laboratory (ORNL). That novel design concept was first envisioned by many of the same µSR experts at a workshop held previously at ORNL in 2016. The participants expressed that the current design had the potential to be a world-leading µSR facility, and strongly encouraged the principal investigators to continue their work in order to refine the concept and determine instrument parameters that would enable new scientific opportunities

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of Portable Programming Models to Accelerate LArTPC Detector Simulations

The Liquid Argon Time Projection Chamber (LArTPC) technology is widely used in high energy physics experiments, including the upcoming Deep Underground Neutrino Experiment (DUNE). Accurately simulating LArTPC detector responses is essential for analysis algorithm development and physics model interpretations. Accurate LArTPC detector response simulations are computationally demanding, and can become a bottleneck in the analysis workflow. Compute devices such as General-Purpose Graphics Processing Units (GPGPUs) have the potential to substantially accelerate simulations compared to traditional CPU-only processing. The software development for these compute accelerators often carries the cost of specialized code refactorization and porting to match the target hardware architecture. With the rapid evolution and increased diversity of the computer architecture landscape, it is highly desirable to have a portable solution that also maintains reasonable performance. We report our ongoing effort in evaluating Kokkos as a basis for this portable programming model using LArTPC simulations in the context of the Wire-Cell Toolkit, a C++ library for LArTPC simulations, data analysis, reconstruction and visualization.

47 OTHER INSTRUMENTATION↗

US Muon Workshop 2021: A road map for a future Muon Facility

The workshop title “US Muon Workshop 2021: A road map for a future Muon Facility” was held virtually on February 1-2, 2021. The workshop aimed to bring together world experts in muon spectroscopy (µSR) and other techniques along with interested stakeholders to evaluate the scientific need to construct a new µSR facility in the United States (US). The more than 200 participants highlighted several key scientific areas for µSR research, including quantum materials, hydrogen chemistry, and battery materials, and how each area could benefit from a new, high flux pulsed muon source. Experts also discussed aspects of the µSR technique, such as low-energy µSR, novel software developments, alongside beam and detector technologies, that could enable revolutionary advances in µSR at a next-generation facility. The workshop concluded with discussion of a concept being developed for a new µSR facility at the Spallation Neutron Source (SNS) of Oak Ridge National Laboratory (ORNL). That novel design concept was first envisioned by many of the same µSR experts at a workshop held previously at ORNL in 2016. The participants expressed that the current design had the potential to be a world-leading µSR facility, and strongly encouraged the principal investigators to continue their work in order to refine the concept and determine instrument parameters that would enable new scientific opportunities.

36 MATERIALS SCIENCE↗

Transition radiation effects in superconducting granules

The paper examines the use of a superheated superconducting suspension as a transition radiation detector of relativistic charged particles. The suspensions would also be used for detecting low-energy X-ray photons. The DESY experiment for developing such a superconducting detector has been carried out at a 7 GeV electron synchrotron. The detection is shown to be based on the recordable flipping of the state of a single superconducting grain.

Drukier, A. K.↗

Evaluation of Portable Programming Models to Accelerate LArTPC Detector Simulations

The Liquid Argon Time Projection Chamber (LArTPC) technology is widely used in high energy physics experiments, including the upcoming Deep Underground Neutrino Experiment (DUNE). Accurately simulating LArTPC detector responses is essential for analysis algorithm development and physics model interpretations. Accurate LArTPC detector response simulations are computationally demanding, and can become a bottleneck in the analysis workflow. Compute devices such as General-Purpose Graphics Processing Units (GPGPUs) have the potential to substantially accelerate simulations compared to traditional CPU-only processing. The software development that requires often carries the cost of specialized code refactorization and porting to match the target hardware architecture. With the rapid evolution and increased diversity of the computer architecture landscape, it is highly desirable to have a portable solution that also maintains reasonable performance. We report our ongoing effort in evaluating Kokkos as a basis for this portable programming model using LArTPC simulations in the context of the Wire-Cell Toolkit, a C++ library for LArTPC simulations, data analysis, reconstruction and visualization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Differentiable Simulation of a Liquid Argon Time Projection Chamber

Liquid argon time projection chambers (LArTPCs) are widely used in particle detection for their tracking and calorimetric capabilities. The particle physics community actively builds and improves high-quality simulators for such detectors in order to develop physics analyses in a realistic setting. The ability of these simulators to mimic real, measured data is limited by the modeling of the physical detectors used for data collection. This modeling can be improved by performing dedicated calibration measurements. Conventional approaches calibrate individual detector parameters or processes one at a time. However, the impact of detector processes is entangled, making this a poor description of the underlying physics. We introduce a differentiable simulator that enables a gradient-based optimization, allowing for the first time a simultaneous calibration of all detector parameters. We describe the procedure of making a differentiable simulator, highlighting the challenges of retaining the physics quality of the standard, non-differentiable version while providing meaningful gradient information. We further discuss the advantages and drawbacks of using our differentiable simulator for calibration. Finally, we provide a starting point for extensions to our approach, including applications of the differentiable simulator to physics analysis pipelines.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigation of CCD-digicon detector system characteristics

The reported investigation was undertaken with the aim to develop state-of-the-art detector technology for use in astronomical observations. Basic properties of the Digicon concept are to be extended to the two-dimensional capabilities of CCDs. The basic CCD-Digicon tube configuration utilizes a thinned, backside-illuminated CCD in place of the linear, discrete diode array at the back end of a windowed space telescope (ST) design Digicon tube. It is pointed out that the detector system built around the considered device promises to exhibit high photometric accuracy in combination with large numbers of uniform independent resolution elements. Potential applications include space astronomy missions with capability for observations extending into the extreme ultraviolet spectral region. Attention is given to continuing investigations into the characteristics of CCD response to backside photoelectron bombardment, taking into account the development of charge pulse centroiding readout techniques in combination with magnetic deflection substepping.

Hier, R. G.↗

First Event-by-Event Identification of Cherenkov Radiation from Sub-Mev Particles in Liquid Argon

This Letter reports the event-by-event observation of Cherenkov light from sub-MeV electrons in a high scintillation light-yield liquid argon detector by the coherent CAPTAIN-Mills (CCM) experiment. The CCM200 detector, located at Los Alamos National Laboratory, instruments seven tons (fiducial volume) of liquid argon with 200 eight-inch photomultiplier tubes, 80% of which are coated in a wavelength-shifting material and the remaining 20% are uncoated. In the prompt time region of an event, defined as - 6 ≤ t < 0 ns relative to the event start time t = 0 , the uncoated photomultiplier tubes are primarily sensitive to visible Cherenkov photons. Using gamma rays from a Na 22 source for production of sub-MeV electrons, we isolated prompt Cherenkov light with > 5 σ confidence and developed a selection to obtain a low-background electromagnetic sample. This is the first event-by-event observation of Cherenkov photons from sub-MeV electrons in a high-yield scintillator detector and represents a milestone in low-energy particle detector development.

Aguilar-Arevalo, A. A. [UNAM, Mexico]↗

Energy resolution enhancement of mercuric iodide detectors

A pulse processing technique has been developed which improves the gamma-ray energy resolution of mercuric iodide detectors. The technique employs a fast (100 ns) and a slow (6.4 microsec) pulse height analysis to correct for signal variations due to variations in charge trapping. The capabilities of the technique for energy resolution enhancement are discussed as well as the utility of the technique for examining the trapping characteristics of individual detectors. An energy resolution of 2.6 percent FWHM at 662 keV was achieved with an acceptance efficiency of 100 percent from a mercuric iodide detector which gives 8.3 percent FWHM using standard techniques.

Finger, M.↗