SEARCH · Engineering Papers
Results for “design of test”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Particle-to-sCO2 Heat Exchanger Experimental Test Station Design and Construction.
Abstract not provided.
Designing and Testing the High-Purity Germanium Gamma-ray Spectrometer for the Dragonfly Mission to Titan
Explore the source record for details and available documents.
Design and Testing of a Recirculating Dust Filtration Loop for High-Temperature Particle Receivers.
Abstract not provided.
Methods for rule-based genome design
Methods and systems for designing, testing, and validating genome designs based on rules or constraints or conditions or parameters or features and scoring are described herein. A computer-implemented method includes receiving data for a known genome and a list of alleles, identifying and removing occurrences of each allele in the known genome, determining a plurality of allele choices with which to replace occurrences in the known genome, generating a plurality of alternative gene sequences for a genome design based on the known genome, wherein each alternative gene sequence comprises a different allele choice, applying a plurality of rules or constraints or conditions or parameters or features to each alternative gene sequence by assigning a score for each rule or constraint or condition or parameter or feature in each alternative gene sequence, resulting in scores for the applied plurality of rules or constraints or conditions or parameters or features, scoring each alternative gene sequence based on a weighted combination of the scores for the plurality of rules or constraints or conditions or parameters or features, and selecting at least one alternative gene sequence as the genome design based on the scoring.
Dry Heatsink Capsule and Large Irradiation Test Vehicle Design for TREAT
Review of design features and how fabrication will be completed for DRIFT Capsules, Big-BUSTER, and Moderator Assemblies for Big-BUSTER in TREAT.
Designing and Testing of A High-Temperature Particle Lift for Concentrating Solar Power Applications
Explore the source record for details and available documents.
Design and Test Validation of a Flat Flex Assembly Multi-Sensor Package
Explore the source record for details and available documents.
AGR-5/6/7 Irradiation Disassembly and Metrology First Look
The Advanced Gas Reactor (AGR) Fuel Development and Qualification Program was established to perform research and development on tristructural isotropic (TRISO)-coated particle fuel to support deployment of high-temperature gas-cooled reactors (HTGRs), which are graphite-moderated nuclear reactors cooled with helium. This work continues as part of the Advanced Reactor Technologies (ART) TRISO Fuel Program. The overarching program goal is to provide a baseline fuel qualification data set to support licensing, deployment, and operation of HTGRs in the United States. To achieve these goals, the program includes fuel fabrication, irradiations of TRISO fuels and high-temperature materials (e.g., graphite), safety testing and post-irradiation examination (PIE), fuel performance modeling, and fission product transport and source term determination. The ART AGR program has conducted four distinct fuel irradiation experiments in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). The first of these irradiation tests, designated AGR-1, began in ATR in December of 2006 and ended in November 2009. This experiment was primarily to act as a shakedown test of the multi-capsule test train design and to provide early data on fuel performance that would be used in fuel fabrication process development. AGR-1 fuel kernels were produced on an engineering scale, but the TRISO coatings and cylindrical fuel compacts were fabricated on a laboratory scale. The AGR-1 PIE was completed and the final report was published in 2015. The second irradiation test, AGR-2, started in ATR in June 2010 and ended in October 2013. The AGR-2 irradiation test was designed to provide fuel performance data for coated particles fabricated on an engineering-scale pilot line using a coater with an internal chamber diameter of 150 mm (6 in.). The final PIE report was published in 2021. AGR-3/4, a single irradiation that combined what were originally conceived as the third and fourth tests, was to support the refinement of fission product transport models and to assess the effects of sweep gas impurities on fuel performance and fission product transport. PIE of the AGR-3/4 experiment is still in progress as of this writing. The subject of this report is AGR-5/6/7, the final qualification test of AGR TRISO fuel made entirely at the engineering scale.
Summary of CPAS Gen II Parachute Analysis
The Orion spacecraft is currently under development by NASA and Lockheed Martin. Like Apollo, Orion will use a series of parachutes to slow its descent and splashdown safely. The Orion parachute system, known as the CEV Parachute Assembly System (CPAS), is being designed by NASA, the Engineering and Science Contract Group (ESCG), and Airborne Systems. The first generation (Gen I) of CPAS testing consisted of thirteen tests and was executed in the 2007-2008 timeframe. The Gen I tests provided an initial understanding of the CPAS parachutes. Knowledge gained from Gen I testing was used to plan the second generation of testing (Gen II). Gen II consisted of six tests: three singleparachute tests, designated as Main Development Tests, and three Cluster Development Tests. Gen II required a more thorough investigation into parachute performance than Gen I. Higher fidelity instrumentation, enhanced analysis methods and tools, and advanced test techniques were developed. The results of the Gen II test series are being incorporated into the CPAS design. Further testing and refinement of the design and model of parachute performance will occur during the upcoming third generation of testing (Gen III). This paper will provide an overview of the developments in CPAS analysis following the end of Gen I, including descriptions of new tools and techniques as well as overviews of the Gen II tests.
Evaluation of Additively Manufactured Monolithic SiC and SiC-Matrix Ceramic Matrix Composites for Concentrating Solar Receiver Applications - Fabrication and Testing of Receiver Design Feature Specimens in a Simulating Lab Test via Laser Heating
Increasing operating temperatures of solar receivers is paramount to the efficiency of concentrated solar thermal (CST) and solar power (CSP) systems. Owing to its high temperature stability combined with excellent thermal and optical properties, SiC has been the material of choice for application in high-temperature solar receivers. We report the results of our study of the effective heat transfer characteristics of several candidate SiC structure motifs, or feature geometries, which are fabricated via additive manufacturing. The SiC structure motifs studied include different permutations of three-dimensional periodic lattices and defined shapes. A solar-thermal simulating laboratory test setup is constructed using a 4kW CO2 laser system with beam shaping optics to apply concurrent radiative heating power on one face of 2”-diameter cylindrical feature specimens, representing the structure motifs of interest for receiver element design, while flowing through the sample as heat transfer fluid. Using the test setup, simulative test conditions representative of a concentrated solar flux of up to ~2000 suns could be achieved in the lab tests under varying air flow through the test structure. A simple 1D numerical analysis scheme is developed to extract an effective or compound heat transfer coefficient representative of the test structure under steady-state heat flow conditions. The test results and their use to guide the selection and optimization of SiC material and structure motifs for the receiver element design fabrication are discussed.
R&D to Ensure a Scientific Basis for Qualification Tests and Standards (Final Report)
Project return on investment in a photovoltaic (PV) system depends increasingly on maintaining high energy yields, and the system lifetime is a major factor in levelized cost of electricity (LCOE). Thus, the rate of PV deployment and the success of these assets depends upon reliable long-term power generation. The overarching objective of this program is to improve photovoltaic (PV) module reliability via development of tests and standards. Where reliability problems or risk are discovered, we can design tests to ensure that these liabilities don't affect future generations of products. Customers can use these tests to understand which products are susceptible to certain degradation mechanisms, and manufacturers can use the tests to design unwanted characteristics out of their products. The work under this program identifies PV reliability needs, performs characterization that provides scientific understanding of targeted degradation mechanisms, and translates those data into practical and predictive test protocols and standards. Major accomplishments include: A model for polarization-type potential induced degradation (PID-p) was developed and validated against experimental data. NREL is currently leading a new edition of IEC 62804-1 for PID detection. PID-p can cause large losses in current and voltage for some module designs on cloudy days. Finite element modeling (FEM) and experiment was used to determine when cells crack in a module. It was shown that cells in landscape orientation are much more likely to crack than those on portrait orientation. Shortly thereafter, the first products with portrait-oriented cells were introduced. Studies of how to test for light and elevated temperature degradation (LeTID) culminated with the publication of IEC TS 63342. Software to predict the progression of LeTID was developed, validated, and made publicly available. Field validated tests and international standards for durability of PV module coatings abrasion, backsheets, and encapsulants were developed. Examples are IEC 62788-1-1, IEC 62788-2 ED2, IEC TS 62788-7-2, IEC 62788-7-3 ED1, IEC 63209-2. NREL led the development a high-temperature testing technical specification, and published guidelines that enable installers to determine whether higher-temperature testing is needed, simply based on location and mounting configuration. In a number of our case studies, variations in the bills of materials or workmanship have been associated with variations in reliability. These observations emphasize the importance of quality assurance to reliability. A framework for criticality (i.e. Pareto) analysis was developed and published. The framework helps us and other researchers determine what problems should be addressed for reliability research to have the biggest industry impact. NREL continues to participate actively in international standards development and stakeholder engagement activities, including organizing an annual PV Reliability Workshop. These activities are important for ensuring we address issues that are relevant and timely, and that we convey our results to those who may benefit.
Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage
The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.
Determination of Parachute Joint Factors using Seam and Joint Testing
This paper details the methodology for determining the joint factor for all parachute components. This method has been successfully implemented on the Capsule Parachute Assembly System (CPAS) for the NASA Orion crew module for use in determining the margin of safety for each component under peak loads. Also discussed are concepts behind the joint factor and what drives the loss of material strength at joints. The joint factor is defined as a "loss in joint strength...relative to the basic material strength" that occurs when "textiles are connected to each other or to metals." During the CPAS engineering development phase, a conservative joint factor of 0.80 was assumed for each parachute component. In order to refine this factor and eliminate excess conservatism, a seam and joint testing program was implemented as part of the structural validation. This method split each of the parachute structural joints into discrete tensile tests designed to duplicate the loading of each joint. Breaking strength data collected from destructive pull testing was then used to calculate the joint factor in the form of an efficiency. Joint efficiency is the percentage of the base material strength that remains after degradation due to sewing or interaction with other components; it is used interchangeably with joint factor in this paper. Parachute materials vary in type-mainly cord, tape, webbing, and cloth -which require different test fixtures and joint sample construction methods. This paper defines guidelines for designing and testing samples based on materials and test goals. Using the test methodology and analysis approach detailed in this paper, the minimum joint factor for each parachute component can be formulated. The joint factors can then be used to calculate the design factor and margin of safety for that component, a critical part of the design verification process.
The 1.06 micrometer wideband laser modulator: Fabrication and life testing
The design, fabrication, testing and delivery of an optical modulator which will operate with a mode-locked Nd:YAG laser at 1.06 micrometers were performed. The system transfers data at a nominal rate of 400 Mbps. This wideband laser modulator can transmit either Pulse Gated Binary Modulation (PGBM) or Pulse Polarization Binary Modulation (PPBM) formats. The laser beam enters the modulator and passes through both crystals; approximately 1% of the transmitted beam is split from the main beam and analyzed for the AEC signal; the remaining part of the beam exits the modulator. The delivered modulator when initially aligned and integrated with laser and electronics performed very well. The optical transmission was 69.5%. The static extinction ratio was 69:1. A 1000 hour life test was conducted with the delivered modulator. A 63 bit pseudorandom code signal was used as a driver input. At the conclusion of the life test the modulator optical transmission was 71.5% and the static extinction ratio 65:1.
Exploratory studies of the cruise performance of upper surface blown configurations. Experimental program: Test facilities, model design instrumentation, and lowspeed, high-lift tests
The model hardware, test facilities and instrumentation utilized in an experimental study of upper surface blown configurations at cruise is described. The high speed (subsonic) experimental work, studying the aerodynamic effects of wing nacelle geometric variations, was conducted around semispan model configurations composed of diversified, interchangeable components. Power simulation was provided by high pressure air ducted through closed forebody nacelles. Nozzle geometry was varied across size, exit aspect ratio, exit position and boattail angle. Three dimensional force and two dimensional pressure measurements were obtained at cruise Mach numbers from 0.5 to 0.8 and at nozzle pressure ratios up to about 3.0. The experimental investigation was supported by an analytical synthesis of the system using a vortex lattice representation with first order power effects. Results are also presented from a compatibility study in which a short haul transport is designed on the basis of the aerodynamic findings in the experimental study as well as acoustical data obtained in a concurrent program. High lift test data are used to substantiate the projected performance of the selected transport design.
TPSAS-NF1676L-12829-DND
Collaborative research between NASA and U.S. rotorcraft companies through the Vertical Lift Consortium, to design, test, and analyze representative validation test articles. - Representative problems and designs developed with partners - Validation articles and characterization specimens manufactured by partners - Develop analytical models to predict delamination behavior using commercial codes, characterization data, and test article data - NASA Space Act Agreement (SAA1-818) with CRI, August 2007 August 2012; funded through Subsonic Rotary Wing program
Test program, helium II orbital resupply coupling
The full scope of this program was to have included development tests, design and production of custom test equipment and acceptance and qualification testing of prototype and protoflight coupling hardware. This program was performed by Ball Aerospace Systems Division, Boulder, Colorado until its premature termination in May 1991. Development tests were performed on cryogenic face seals and flow control devices at superfluid helium (He II) conditions. Special equipment was developed to allow quantified leak detection at large leak rates up to 8.4 x 10(exp -4) SCCS. Two major fixtures were developed and characterized: The Cryogenic Test Fixture (CTF) and the Thermal Mismatch Fixture (Glovebox). The CTF allows the coupling hardware to be filled with liquid nitrogen (LN2), liquid helium (LHe) or sub-cooled liquid helium when hardware flow control valves are either open or closed. Heat leak measurements, internal and external helium leakage measurements, cryogenic proof pressure tests and external load applications are performed in this fixture. Special reusable MLI closures were developed to provide repeatable installations in the CTF. The Thermal Mismatch Fixture allows all design configurations of coupling hardware to be engaged and disengaged while measuring applied forces and torques. Any two hardware components may be individually thermally preconditioned within the range of 117 deg K to 350 deg K prior to engage/disengage cycling. This verifies dimensional compatibility and operation when thermally mismatched. A clean, dry GN2 atmosphere is maintained in the fixture at all times. The first shipset of hardware was received, inspected and cycled at room temperature just prior to program termination.