Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coverage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Modeling the SHG activities of diverse protein crystals

The origins of the diversity in the SHG signal from protein crystals are investigated and potential protein-crystal coverage by SHG microscopy is assessed. A symmetry-additive ab initio model for second-harmonic generation (SHG) activity of protein crystals was applied to assess the likely protein-crystal coverage of SHG microscopy. Calculations were performed for 250 proteins in nine point-group symmetries: a total of 2250 crystals. The model suggests that the crystal symmetry and the limit of detection of the instrument are expected to be the strongest predictors of coverage of the factors considered, which also included secondary-structural content and protein size. Much of the diversity in SHG activity is expected to arise primarily from the variability in the intrinsic protein response as well as the orientation within the crystal lattice. Two or more orders-of-magnitude variation in intensity are expected even within protein crystals of the same symmetry. SHG measurements of tetragonal lysozyme crystals confirmed detection, from which a protein coverage of ∼84% was estimated based on the proportion of proteins calculated to produce SHG responses greater than that of tetragonal lysozyme. Good agreement was observed between the measured and calculated ratios of the SHG intensity from lysozyme in tetragonal and monoclinic lattices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Growth and structural evolution of Sn on Ag(001): Epitaxial monolayer to thick alloy film

The growth and structure of Sn on Ag(001), from submonolayer to thick film coverages at room temperature, are studied using low energy electron diffraction, x-ray photoemission spectroscopy and angle-resolved photoemission spectroscopy (ARPES) techniques. The authors observe different growth modes for submonolayer Sn coverages and for higher Sn coverages. Systematic surface structural evolution, consistent with the substitution of surface Ag atoms by Sn atoms, is observed for submonolayer Sn coverages while an ordered Ag-Sn bulk alloy film is formed for higher Sn coverages with an Ag overlayer. For monolayer coverage of Sn, a pseudomorphic growth of a Sn layer without alloying is determined. ARPES results also confirm the presence of an ordered Ag overlayer on the bulk Ag-Sn alloy film, suggesting the formation of an Ag/Ag{sub 3}Sn/Ag(001) sandwich structure at the surface for higher Sn coverages. The present results illustrate the complex interplay of atomic mobilities, surface free-energies, and alloy formation energies in determining the growth and structural properties of the system.

36 MATERIALS SCIENCE↗

A method for deriving a 4D-interpolated balanced planning target for mobile tumor radiotherapy

Purpose: Tumor control and normal tissue toxicity are strongly correlated to the tumor and normal tissue volumes receiving high prescribed dose levels in the course of radiotherapy. Planning target definition is, therefore, crucial to ensure favorable clinical outcomes. This is especially important for stereotactic body radiation therapy of lung cancers, characterized by high fractional doses and steep dose gradients. The shift in recent years from population-based to patient-specific treatment margins, as facilitated by the emergence of 4D medical imaging capabilities, is a major improvement. The commonly used motion-encompassing, or internal-target volume (ITV), target definition approach provides a high likelihood of coverage for the mobile tumor but inevitably exposes healthy tissue to high prescribed dose levels. The goal of this work was to generate an interpolated balanced planning target that takes into account both tumor coverage and normal tissue sparing from high prescribed dose levels, thereby improving on the ITV approach. Methods: For each 4DCT dataset, 4D deformable image registration was used to derive two bounding targets, namely, a 4D-intersection and a 4D-composite target which minimized normal tissue exposure to high prescribed dose levels and maximized tumor coverage, respectively. Through definition of an ''effective overlap volume histogram'' the authors derived an ''interpolated balanced planning target'' intended to balance normal tissue sparing from prescribed doses with tumor coverage. To demonstrate the dosimetric efficacy of the interpolated balanced planning target, the authors performed 4D treatment planning based on deformable image registration of 4D-CT data for five previously treated lung cancer patients. Two 4D plans were generated per patient, one based on the interpolated balanced planning target and the other based on the conventional ITV target. Plans were compared for tumor coverage and the degree of normal tissue sparing resulting from the new approach was quantified. Results: Analysis of the 4D dose distributions from all five patients showed that while achieving tumor coverage comparable to the ITV approach, the new planning target definition resulted in reductions of lung V{sub 10}, V{sub 20}, and V{sub 30} of 6.3% {+-} 1.7%, 10.6% {+-} 3.9%, and 12.9% {+-} 5.5%, respectively, as well as reductions in mean lung dose, mean dose to the GTV-ring and mean heart dose of 8.8% {+-} 2.5%, 7.2% {+-} 2.5%, and 10.6% {+-} 3.6%, respectively. Conclusions: The authors have developed a simple and systematic approach to generate a 4D-interpolated balanced planning target volume that implicitly incorporates the dynamics of respiratory-organ motion without requiring 4D-dose computation or optimization. Preliminary results based on 4D-CT data of five previously treated lung patients showed that this new planning target approach may improve normal tissue sparing without sacrificing tumor coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-450: Dosimetric Impact of Rotational Error On Multiple-Target Intensity-Modulated Radiosurgery (IMRS) with Single-Isocenter

Purpose: Evaluating the dosimetric-impact on multiple-targets placed away from the isocenter-target with varying rotational-error introduced by initial setup uncertainty and/or intrafractional-movement Methods: CyberKnife-Phantom was scanned with the Intracranial SRS-protocol of 1.25mm slice-thickness and the multiple-targets(GTV) of 1mm and 10mm in diameter were contoured on the Eclipse. PTV for distal-target only was drawn with 1mm expansion around the GTV to find out how much margin is needed to compensate for the rotational-error. The separation between the isocenter-target and distal-target was varied from 3cm to 7cm. RapidArc-based IMRS plans of 16Gy single-fraction were generated with five non-coplanar arcs by using Varian TrueBeam-STx equipped with high resolution MLC leaves of 2.5mm at center and with dose-rate of 1400MU/min at 6MV for flatteringfilter- free(FFF). An identical CT image with intentionally introduced 1° rotational-error was registered with the planning CT image, and the isodose distribution and Dose-Volume-Histogram(DVH) were compared with the original plans. Additionally, the dosimetric-impact of rotational error was evaluated with that of 6X photon energy which was generated with the same target-coverage. Results: For the 1mm-target with 6X-FFF, PTV-coverage(D100) of the distal-target with 1° rotational-error decreased from 1.00 to 0.35 as the separation between isocenter-target and distal-target increased from 3cm to 7cm. However, GTV-coverage(D100) was 1.0 except that of 7cm-separation(0.55), which resulted from the 1mm-margin around the distal-target. For 6X photon, GTV-coverage remained at 1.0 regardless of the separation of targets, showing that the dosimetric-impact of rotational error depends on the degree of rotational-error, separation of targets, and dose distribution around targets. For 10mm-target, PTV-coverage of distaltarget located 3cm-away was better than that of 1mm-target(0.93 versus 0.7) and GTV-coverage was 1.0 regardless of 6X-FFF/6X photon beams. Conclusion: RapidArc-based Multiple-target IMRS may Resultin a compromised outcome due to the setup-error for distal-targets. With 1mm-margin, GTV-coverage of distal-target was 1.0 although the separation of targets was up to 5cm.

07 ISOTOPE AND RADIATION SOURCES↗

Density Functional Theory Study of the Initial Stages of Cl-Induced Degradation of α -Cr 2 O 3 Passive Film

The ion exchange and point defect models are two prominent models describing the role of anions, such as chlorides, in the degradation of passive oxide films. Here the thermodynamic feasibility of critical steps of Cl-induced degradation of a hydroxylated α-Cr 2 O 3 (0001) surface, as proposed by these two models, are studied. Both models begin with Cl substitution of surface OH and H 2 O, which becomes less favorable with increasing Cl coverage. The initial stages of Cl-induced breakdown of the α-Cr 2 O 3 depend on Cl coverage and the presence of O vacancy near the surface as follows: (1) neither Cl insertion (supporting the ion exchange model) nor Cr vacancy formation (supporting the point defect model) is feasible at low Cl coverages except in the presence of O vacancies near the surface, where Cl insertion is thermodynamically feasible even at low coverages, (2) in the absence of O vacancies, Cr vacancy formation becomes feasible from 10/12 ML onwards whereas Cl insertion by exchange with subsurface OH only becomes feasible at full coverage. This implies that at higher coverages Cl-induced degradation first initiates through a vacancy formation mechanism, but both insertion and vacancy formation would be feasible at full coverage.

36 MATERIALS SCIENCE↗

FY11 Report on Metagenome Analysis using Pathogen Marker Libraries

A method, sequence library, and software suite was invented to rapidly assess whether any member of a pre-specified list of threat organisms or their near neighbors is present in a metagenome. The system was designed to handle mega- to giga-bases of FASTA-formatted raw sequence reads from short or long read next generation sequencing platforms. The approach is to pre-calculate a viral and a bacterial "Pathogen Marker Library" (PML) containing sub-sequences specific to pathogens or their near neighbors. A list of expected matches comparing every bacterial or viral genome against the PML sequences is also pre-calculated. To analyze a metagenome, reads are compared to the PML, and observed PML-metagenome matches are compared to the expected PML-genome matches, and the ratio of observed relative to expected matches is reported. In other words, a 3-way comparison among the PML, metagenome, and existing genome sequences is used to quickly assess which (if any) species included in the PML is likely to be present in the metagenome, based on available sequence data. Our tests showed that the species with the most PML matches correctly indicated the organism sequenced for empirical metagenomes consisting of a cultured, relatively pure isolate. These runs completed in 1 minute to 3 hours on 12 CPU (1 thread/CPU), depending on the metagenome and PML. Using more threads on the same number of CPU resulted in speed improvements roughly proportional to the number of threads. Simulations indicated that detection sensitivity depends on both sequencing coverage levels for a species and the size of the PML: species were correctly detected even at ~0.003x coverage by the large PMLs, and at ~0.03x coverage by the smaller PMLs. Matches to true positive species were 3-4 orders of magnitude higher than to false positives. Simulations with short reads (36 nt and ~260 nt) showed that species were usually detected for metagenome coverage above 0.005x and coverage in the PML above 0.05x, and detection probability appears to be a function of both coverages. Multiple species could be detected simultaneously in a simulated low-coverage, complex metagenome, and the largest PML gave no false negative species and no false positive genera. The presence of multiple species was predicted in a complex metagenome from a human gut microbiome with 1.9 GB of short reads (75 nt); the species predicted were reasonable gut flora and no biothreat agents were detected, showing the feasibility of PML analysis of empirical complex metagenomes.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of error in TOMS total ozone as a function of orbit and attitude parameters

Computer simulations of orbital scenarios were performed to examine the effects of orbital altitude, equator crossing time, attitude uncertainty, and orbital eccentricity on ozone observations by future satellites. These effects were assessed by determining changes in solar and viewing geometry and earth daytime coverage loss. The importance of these changes on ozone retrieval was determined by simulating uncertainties in the TOMS ozone retrieval algorithm. The major findings are as follows: (1) Drift of equator crossing time from local noon would have the largest effect on the quality of ozone derived from TOMS. The most significant effect of this drift is the loss of earth daytime coverage in the winter hemisphere. The loss in coverage increases from 1 degree latitude for + or - 1 hour from noon, 6 degrees for + or - 3 hours from noon, to 53 degrees for + or - 6 hours from noon. An additional effect is the increase in ozone retrieval errors due to high solar zenith angles. (2) To maintain contiguous earth coverage, the maximum scan angle of the sensor must be increased with decreasing orbital altitude. The maximum scan angle required for full coverage at the equator varies from 60 degrees at 600 km altitude to 45 degrees at 1200 km. This produces an increase in spacecraft zenith angle, theta, which decreases the ozone retrieval accuracy. The range in theta was approximately 72 degrees for 600 km to approximately 57 degrees at 1200 km. (3) The effect of elliptical orbits is to create gaps in coverage along the subsatellite track. An elliptical orbit with a 200 km perigee and 1200 km apogee produced a maximum earth coverage gap of about 45 km at the perigee at nadir. (4) An attitude uncertainty of 0.1 degree in each axis (pitch, roll, yaw) produced a maximum scan angle to view the pole, and maximum solar zenith angle).

Gregg, W. W.↗

FX2 advanced fogging technology - 15711

Problem statement: The need for an advanced technology that can better address potential airborne contaminants at DOE Savannah River Site 235-F. Current methods of knocking down or fixing this contamination are labor intensive, costly, and sometimes ineffective. Thus, to make exposure ALARA, the advanced fogging effort is being tested using Idaho National Laboratory's FX2 fixative agent. The FX2 fogging agent is a proprietary mixture of water, latex paint (LTX), glycerin (GLY) and sodium lauryl sulfate (SLS). Initial development began in 2006 when a DOE Small Business Innovative Research (SBIR) grant resulted in the development of a conceptual advanced capture coating fog system. This coating is shown to be excellent at reducing airborne contamination and 'fixing' particulates in place as demonstrated by Idaho National Lab. Controlling Potential Airborne Particulates: Testing capacity to knockdown airborne particulates. Evaluating ability to fix to different surfaces (e.g., glass, wood, steel, concrete, brick). Line of sight as well as non-line of sight (shadowed) locations will be tested for coverage. Adhesiveness and Coverage of Surface Area: Contact area will be placed under air pressure to attempt dislodging of dried mixture. Particle analysis utilizing ImageJ will be conducted to determine quantifiable coverage. Ignitability: Observation of the FX2's reactivity to flame and heat sources as it is being applied. Results will provide useful information for the prevention of potential hazards. Determine Shielding Properties Against Alpha Sources: Determine the shielding abilities of the FX2. Fogging agent against an alpha particle emitting point source. Evaluating Critical Properties: These properties will be evaluated to better characterize the FX2 and allow for optimal understanding of results: ASTM E1354 - Burn Rate; NFPA 296-Flashover; ASTM D2196 - Viscosity; ASTM D1331 - Surface Tension; ASTM D792 - Density. Testing Innovations: Developed by the National Institutes of Health, ImageJ is a public domain image processing program that allows for the analysis that this effort requires. Coverage: Through contrast analysis, ImageJ can be used to determine the coverage of the agent upon any of the testing surfaces. Correlations: With the feature of coverage evaluation, a relationship, and thus a graphical representation, can be made between surface coverage and radiation shielding. Future work: Engineering and manufacturing of mobile robotic fogging device. ASTM WK5394: establishing performance specifications for stabilizers to minimize migration of dispersible radioactive contamination.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Probing surface-adsorbate interactions through active particle dynamics

Adsorbate molecules present in a reaction mixture may bind to and block catalytic sites. Measurement of the surface coverage of these molecules via adsorption isotherms is critical for modeling and design of catalytic reactions on surfaces. However, it is challenging to measure isotherms in solution in a way that is directly relevant to catalytic activity under reaction conditions, particularly since adsorbates may bind with an enormous range of surface affinity parameters. Here we used the motion of self-propelled catalytic Janus particles, which employ the decomposition of hydrogen peroxide fuel as a propulsion mechanism, to determine the effective surface coverage of thioglycerol, furfural, and ethanol on a platinum surface as a function of concentration in aqueous solution by measuring the decrease in active motion due to the blocking of active sites. For strongly adsorbing thioglycerol, this effective coverage was compared and contrasted to the total adsorbed amount measured using inductively-coupled plasma analysis. Demonstrating the broad applicability of this approach, the surface affinity of the three adsorbates spanned more than four orders of magnitude. For each species, the adsorbate-mediated attenuation of active motion occurred over a wide concentration range and was well-described by a Langmuir isotherm. The strongly interacting thioglycerol had the highest affinity towards the surface (K a = 15.5 ± 4.3 mM –1 ) and fully deactivated the active particle motion at surface saturation. Furfural had an intermediate affinity (K a = 0.42 ± 0.07 mM –1 ) but did not fully block H 2 O 2 access to the surface at apparent saturation, consistent with a maximum fractional surface coverage of θ max = 0.67. Ethanol exhibited even lower affinity (K a = 0.0025 ± 2x10 -4 mM –1 ) and its coverage saturated at only θ max = 0.38. Analysis of isotherms at elevated temperatures enabled direct extraction of the enthalpies of adsorption. The degree of surface coverage at adsorbate saturation appeared to correlate with the relative energies of adsorption for the different adsorbate species and was consistent with adsorbate saturation of one of multiple active site populations towards H 2 O 2 decomposition. Furthermore, computational investigations into solvent effects on furfural adsorption showed good quantitative agreement with the experimental results. This work leverages unique properties of active particles to explore fundamental catalysis questions and demonstrates a novel paradigm for significant and experimentally accessible multidisciplinary research.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uncoordinated Spectrum Sharing in Millimeter Wave Networks Using Carrier Sensing

Here, we propose using Carrier Sensing (CS) for distributed interference management in millimeter-wave (mmWave) cellular networks where spectrum is shared by multiple operators that do not coordinate among themselves. In addition, even the base station sites can be shared by the operators. We describe important challenges in using traditional CS in this setting and propose enhanced CS protocols to address these challenges. Using stochastic geometry, we develop a general framework for downlink coverage probability analysis of our shared mmWave network in the presence of CS and derive the downlink coverage probability expressions for several CS protocols. Our work is the first to investigate and analyze (using stochastic geometry) CS for mmWave networks with spectrum and BS sites shared among non-coordinating operators. We evaluate the downlink coverage probability of our shared mmWave network using simulations as well as numerical examples based on our analysis. Our evaluations show that our proposed approach leads to an improvement in coverage probability, compared to the coverage probability with no CS, for higher values of signal-to-interference and noise ratio (SINR). Interestingly, our evaluations also reveal that for lower values of SINR, not using any CS is the best strategy in terms of the downlink coverage probability.

42 ENGINEERING↗

Not all platinum surfaces are the same: Effect of the support on fundamental properties of platinum adlayer and its implications for the activity toward hydrogen evolution reaction

The adsorption of atomic hydrogen on a platinum monolayer supported on orthorhombic Mo 2 C(100) surface has been investigated, considering different hydrogen surface coverages. Calculations have been performed using density functional theory with the Perdew-Burke-Ernzerhof exchange correlation functional and a D3 Van der Waals corrections. The theoretical insight has been gained into atomic hydrogen interaction with Pt monolayer, supported on both molybdenum and well-studied tungsten carbide, and considering hydrogen surface coverage. Fundamental properties of Pt adlayer depend on the support, affecting hydrogen evolution activity of the resulting systems. At low hydrogen coverage all systems, with the exception of Pt supported on the molybdenum-terminated Mo 2 C, adsorb H comparably to a pristine Pt(111) surface and their high activity for the hydrogen evolution reaction is predicted. Additionally, at higher coverages supported Pt monolayers interact with atomic hydrogen unlike the Pt(111), suggesting that the activity of the supported and unsupported platinum toward hydrogen evolution reaction have different origins. Furthermore, the position of the supported platinum monolayers on the volcano curve is a function of the surface coverage, more so than for extended metal surfaces. Therefore, hydrogen surface coverage is a key variable to understand the catalytic potential, approaching towards an improved model for screening of electrocatalytic systems.

36 MATERIALS SCIENCE↗

Optimized Planning Target Volume for Intact Cervical Cancer

Purpose: To model interfraction clinical target volume (CTV) variation in patients with intact cervical cancer and design a planning target volume (PTV) that minimizes normal tissue dose while maximizing CTV coverage. Methods and Materials: We analyzed 50 patients undergoing external-beam radiotherapy for intact cervical cancer using daily online cone-beam computed tomography (CBCT). The CBCTs (n = 972) for each patient were rigidly registered to the planning CT. The CTV was delineated on the planning CT (CTV{sub 0}) and the set of CBCTs ({l_brace}CTV{sub 1}-CTV{sub 25}{r_brace}). Manual (n = 98) and automated (n = 668) landmarks were placed over the surface of CTV{sub 0} with reference to defined anatomic structures. Normal vectors were extended from each landmark, and the minimum length required for a given probability of encompassing CTV{sub 1}-CTV{sub 25} was computed. The resulting expansions were used to generate an optimized PTV. Results: The mean (SD; range) normal vector length to ensure 95% coverage was 4.3 mm (2.7 mm; 1-16 mm). The uniform expansion required to ensure 95% probability of CTV coverage was 13 mm. An anisotropic margin of 20 mm anteriorly and posteriorly and 10 mm superiorly, inferiorly, and laterally also would have ensured a 95% probability of CTV coverage. The volume of the 95% optimized PTV (1470 cm{sup 3}) was significantly lower than both the anisotropic PTV (2220 cm{sup 3}) and the uniformly expanded PTV (2110 cm{sup 3}) (p < 0.001). For a 95% probability of CTV coverage, normal lengths of 1-3 mm were found along the superior and lateral regions of CTV{sub 0}, 5-10 mm along the interfaces of CTV{sub 0} with the bladder and rectum, and 10-14 mm along the anterior surface of CTV{sub 0} at the level of the uterus. Conclusion: Optimizing PTV definition according to surface landmarking resulted in a high probability of CTV coverage with reduced PTV volumes. Our results provide data justifying planning margins to use in practice and clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pelvic Nodal Dosing With Registration to the Prostate: Implications for High-Risk Prostate Cancer Patients Receiving Stereotactic Body Radiation Therapy

Purpose: To determine whether image guidance with rigid registration (RR) to intraprostatic markers (IPMs) yields acceptable coverage of the pelvic lymph nodes in the context of a stereotactic body radiation therapy (SBRT) regimen. Methods and Materials: Four to seven kilovoltage cone-beam CTs (CBCTs) from 12 patients with high-risk prostate cancer were analyzed, allowing approximation of an SBRT regimen. The nodal clinical target volume (CTV{sub N}) and bladder were contoured on all kilovoltage CBCTs. The V{sub 100} CTV{sub N}, expressed as a ratio to the same parameter on the initial plan, and the magnitude of translational shift between RR to the IPMs versus RR to the pelvic bones, were computed. The ability of a multimodality bladder filling protocol to minimize bladder height variation was assessed in a separate cohort of 4 patients. Results: Sixty-five CBCTs were assessed. The average V{sub 100} CTV{sub N} was 92.6%, but for a subset of 3 patients the average was 80.0%, compared with 97.8% for the others (P<.0001). The average overall and superior–inferior axis magnitudes of the bony-to-fiducial translations were significantly larger in the subgroup with suboptimal nodal coverage (8.1 vs 3.9 mm and 5.8 vs 2.4 mm, respectively; P<.0001). Relative bladder height changes were also significantly larger in the subgroup with suboptimal nodal coverage (42.9% vs 18.5%; P<.05). Use of a multimodality bladder-filling protocol minimized bladder height variation (P<.001). Conclusion: A majority of patients had acceptable nodal coverage after RR to IPMs, even when approximating SBRT. However, a subset of patients had suboptimal nodal coverage. These patients had large bony-to-fiducial translations and large variations in bladder height. Nodal coverage should be excellent if the superior–inferior axis bony-to-fiducial translation and the relative bladder height change (both easily measured on CBCT) are kept to a minimum. Implementation of a strict bladder filling protocol may achieve this goal.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rates of Reconstruction Failure in Patients Undergoing Immediate Reconstruction With Tissue Expanders and/or Implants and Postmastectomy Radiation Therapy

Objectives: Mastectomy rates for breast cancer have increased, with a parallel increase in immediate reconstruction. For some women, tissue expander and implant (TE/I) reconstruction is the preferred or sole option. This retrospective study examined the rate of TE/I reconstruction failure (ie, removal of the TE or I with the inability to replace it resulting in no final reconstruction or autologous tissue reconstruction) in patients receiving postmastectomy radiation therapy (PMRT). Methods and Materials: Between 2004 and 2012, 99 women had skin-sparing mastectomies (SSM) or total nipple/areolar skin-sparing mastectomies (TSSM) with immediate TE/I reconstruction and PMRT for pathologic stage II to III breast cancer. Ninety-seven percent had chemotherapy (doxorubicin and taxane-based), 22% underwent targeted therapies, and 78% had endocrine therapy. Radiation consisted of 5000 cGy given in 180 to 200 cGy to the reconstructed breast with or without treatment to the supraclavicular nodes. Median follow-up was 3.8 years. Results: Total TE/I failure was 18% (12% without final reconstruction, 6% converted to autologous reconstruction). In univariate analysis, the strongest predictor of reconstruction failure (RF) was absence of total TE/I coverage (acellular dermal matrix and/or serratus muscle) at the time of radiation. RF occurred in 32.5% of patients without total coverage compared to 9% with coverage (P=.0069). For women with total coverage, the location of the mastectomy scar in the inframammary fold region was associated with higher RF (19% vs 0%, P=.0189). In multivariate analysis, weight was a significant factor for RF, with lower weight associated with a higher RF. Weight appeared to be a surrogate for the interaction of total coverage, thin skin flaps, interval to exchange, and location of the mastectomy scar. Conclusions: RFs in patients receiving PMRT were lowered with total TE/I coverage at the time of radiation by avoiding inframammary fold incisions and with a preferred interval of 6 months to exchange.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative assessment of the accuracy of dose calculation using pencil beam and Monte Carlo algorithms and requirements for clinical quality assurance

To compare the doses calculated using the BrainLAB pencil beam (PB) and Monte Carlo (MC) algorithms for tumors located in various sites including the lung and evaluate quality assurance procedures required for the verification of the accuracy of dose calculation. The dose-calculation accuracy of PB and MC was also assessed quantitatively with measurement using ionization chamber and Gafchromic films placed in solid water and heterogeneous phantoms. The dose was calculated using PB convolution and MC algorithms in the iPlan treatment planning system from BrainLAB. The dose calculation was performed on the patient's computed tomography images with lesions in various treatment sites including 5 lungs, 5 prostates, 4 brains, 2 head and necks, and 2 paraspinal tissues. A combination of conventional, conformal, and intensity-modulated radiation therapy plans was used in dose calculation. The leaf sequence from intensity-modulated radiation therapy plans or beam shapes from conformal plans and monitor units and other planning parameters calculated by the PB were identical for calculating dose with MC. Heterogeneity correction was considered in both PB and MC dose calculations. Dose-volume parameters such as V95 (volume covered by 95% of prescription dose), dose distributions, and gamma analysis were used to evaluate the calculated dose by PB and MC. The measured doses by ionization chamber and EBT GAFCHROMIC film in solid water and heterogeneous phantoms were used to quantitatively asses the accuracy of dose calculated by PB and MC. The dose-volume histograms and dose distributions calculated by PB and MC in the brain, prostate, paraspinal, and head and neck were in good agreement with one another (within 5%) and provided acceptable planning target volume coverage. However, dose distributions of the patients with lung cancer had large discrepancies. For a plan optimized with PB, the dose coverage was shown as clinically acceptable, whereas in reality, the MC showed a systematic lack of dose coverage. The dose calculated by PB for lung tumors was overestimated by up to 40%. An interesting feature that was observed is that despite large discrepancies in dose-volume histogram coverage of the planning target volume between PB and MC, the point doses at the isocenter (center of the lesions) calculated by both algorithms were within 7% even for lung cases. The dose distributions measured with EBT GAFCHROMIC films in heterogeneous phantoms showed large discrepancies of nearly 15% lower than PB at interfaces between heterogeneous media, where these lower doses measured by the film were in agreement with those by MC. The doses (V95) calculated by MC and PB agreed within 5% for treatment sites with small tissue heterogeneities such as the prostate, brain, head and neck, and paraspinal tumors. Considerable discrepancies, up to 40%, were observed in the dose-volume coverage between MC and PB in lung tumors, which may affect clinical outcomes. The discrepancies between MC and PB increased for 15 MV compared with 6 MV indicating the importance of implementation of accurate clinical treatment planning such as MC. The comparison of point doses is not representative of the discrepancies in dose coverage and might be misleading in evaluating the accuracy of dose calculation between PB and MC. Thus, the clinical quality assurance procedures required to verify the accuracy of dose calculation using PB and MC need to consider measurements of 2- and 3-dimensional dose distributions rather than a single point measurement using heterogeneous phantoms instead of homogenous water-equivalent phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

Split-field vs extended-field intensity-modulated radiation therapy plans for oropharyngeal cancer: Which spares the larynx? Which spares the thyroid?

Radiation of the low neck can be accomplished using split-field intensity-modulated radiation therapy (sf-IMRT) or extended-field intensity-modulated radiation therapy (ef-IMRT). We evaluated the effect of these treatment choices on target coverage and thyroid and larynx doses. Using data from 14 patients with cancers of the oropharynx, we compared the following 3 strategies for radiating the low neck: (1) extended-field IMRT, (2) traditional split-field IMRT with an initial cord-junction block to 40 Gy, followed by a full-cord block to 50 Gy, and (3) split-field IMRT with a full-cord block to 50 Gy. Patients were planned using each of these 3 techniques. To facilitate comparison, extended-field plans were normalized to deliver 50 Gy to 95% of the neck volume. Target coverage was assessed using the dose to 95% of the neck volume (D{sub 95}). Mean thyroid and larynx doses were computed. Extended-field IMRT was used as the reference arm; the mean larynx dose was 25.7 ± 7.4 Gy, and the mean thyroid dose was 28.6 ± 2.4 Gy. Split-field IMRT with 2-step blocking reduced laryngeal dose (mean larynx dose 15.2 ± 5.1 Gy) at the cost of a moderate reduction in target coverage (D{sub 95} 41.4 ± 14 Gy) and much higher thyroid dose (mean thyroid dose 44.7 ± 3.7 Gy). Split-field IMRT with initial full-cord block resulted in greater laryngeal sparing (mean larynx dose 14.2 ± 5.1 Gy) and only a moderately higher thyroid dose (mean thyroid dose 31 ± 8 Gy) but resulted in a significant reduction in target coverage (D{sub 95} 34.4 ± 15 Gy). Extended-field IMRT comprehensively covers the low neck and achieves acceptable thyroid and laryngeal sparing. Split-field IMRT with a full-cord block reduces laryngeal doses to less than 20 Gy and spares the thyroid, at the cost of substantially reduced coverage of the low neck. Traditional 2-step split-field IMRT similarly reduces the laryngeal dose but also reduces low-neck coverage and delivers very high doses to the thyroid.

61 RADIATION PROTECTION AND DOSIMETRY↗

Adsorption of small hydrocarbons on rutile TiO2(110)

Temperature programmed desorption and molecular beam scattering were used to study the adsorption and desorption of small hydrocarbons (n-alkanes, 1-alkenes and 1-alkynes with 1 - 4 carbon atoms of C1-C4) on rutile TiO2(110). We show that the sticking coefficients for all the hydrocarbons are close to unity (> 0.95) at an adsorption temperature of 60 K. The desorption energies for hydrocarbons of the same chain length increase from n-alkanes to 1-alkenes and to 1-alkynes. This trend is likely a consequence of an additional dative bonding of the alkene and alkyne π system to the coordinatively unsaturated Ti5c sites. Similar to previous studies on the adsorption of n-alkanes on metal and metal oxide surfaces, we find the desorption energies within each group (n-alkanes vs. 1-alkenes vs. 1-alkynes) from Ti5c sites increase linearly with the chain length. The absolute saturation coverages of each hydrocarbon on Ti5c sites were also determined. The saturation coverage of CH4, is found to be ~ 2/3 monolayer (ML). The saturation coverages of C2-C4 hydrocarbons are found nearly independent of the chain length with values of ~1/2 ML for n-alkanes and 1-alkenes and 2/3 ML for 1-alkynes. This result is surprising considering their similar sizes.

adsorption↗

Oxygen adsorption on spontaneously reconstructed Au(511)

The four-fold site on {100} facets, which are potential catalytic sites on high-curvature gold nanoparticles, is difficult to prepare on a gold single crystal due to surface reconstruction. Here, the Au(511) surface with a high density of step edges and a well-maintained {100} local structure was studied by scanning tunneling microscopy (STM), temperature programmed reaction spectroscopy (TPRS), and density functional theory (DFT) calculations. Annealing at 550 K and 870 K induces reconstruction on the Au(511) surface to a mixture of (311) and (711) micro-terraces. At room temperature and low oxygen coverage, oxygen adsorbs at both three- and four-fold sites on the surface, leading to a well-ordered zig-zag structure. Oxygen atoms cause significant orbital hybridization and a slight displacement of the gold atoms to which they bind. High oxygen coverages induce the formation of clusters, which are not active towards oxidation of isopropanol at room temperature and a pressure of 10-10 mbar. Oxygen adsorption saturates at 1 monolayer (ML), and two separate oxygen recombinative desorption peaks were observed at coverages above 0.11 ML. Our characterization of this surface and the O adsorption structure allows future studies of {100} micro-terraces for oxidation reactions, which contributes to studies on gold-based catalysts with an irregular shape.

catalysis (heterogeneous), mesostructured material↗