Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrected data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Release strategies: The CMS approach for development and quality assurance

Now that CMS has started data taking there is a balance to be struck between software release stability for operations and the need to improve the physics and technical performance of the code. In addition new code may need to be developed to correct for unforeseen data taking conditions, and has to be integrated into the mainstream releases with a minimum risk. To keep the process under control, CMS uses regular (twice a day) Integration Builds. A complex set of validation steps is used to verify the software at various stages, from the regular Integration Builds to running a full software and physics validation suite on the grid for major releases. CMS has adopted a development model that tries to strike the correct balance between the needs of stability and a constant improvement, this paper will describe our experience with this model, and tell the story of how the commissioning of the CMS offline has proceeded through the perspective of the past year's releases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Corrective Action Decision Document/Corrective Action Plan for the 92-Acre Area and Corrective Action Unit 111: Area 5 WMD Retired Mixed Waste Pits, Nevada Test Site, Nevada

This Corrective Action Decision Document/Corrective Action Plan (CADD/CAP) has been prepared for the 92-Acre Area, the southeast quadrant of the Radioactive Waste Management Site, located in Area 5 of the Nevada Test Site (NTS). The 92-Acre Area includes Corrective Action Unit (CAU) 111, 'Area 5 WMD Retired Mixed Waste Pits.' Data Quality Objectives (DQOs) were developed for the 92-Acre Area, which includes CAU 111. The result of the DQO process was that the 92-Acre Area is sufficiently characterized to provide the input data necessary to evaluate corrective action alternatives (CAAs) without the collection of additional data. The DQOs are included as Appendix A of this document. This CADD/CAP identifies and provides the rationale for the recommended CAA for the 92-Acre Area, provides the plan for implementing the CAA, and details the post-closure plan. When approved, this CADD/CAP will supersede the existing Pit 3 (P03) Closure Plan, which was developed in accordance with Title 40 Code of Federal Regulations (CFR) Part 265, 'Interim Status Standards for Owners and Operators of Hazardous Waste Treatment, Storage, and Disposal Facilities.' This document will also serve as the Closure Plan and the Post-Closure Plan, which are required by 40 CFR 265, for the 92-Acre Area. After closure activities are complete, a request for the modification of the Resource Conservation and Recovery Act Permit that governs waste management activities at the NTS will be submitted to the Nevada Division of Environmental Protection to incorporate the requirements for post-closure monitoring. Four CAAs, ranging from No Further Action to Clean Closure, were evaluated for the 92-Acre Area. The CAAs were evaluated on technical merit focusing on performance, reliability, feasibility, safety, and cost. Based on the evaluation of the data used to develop the conceptual site model; a review of past, current, and future operations at the site; and the detailed and comparative analysis of the potential CAAs, Closure in Place with Administrative Controls is the preferred CAA for the 92-Acre Area. Closure activities will include the following: (1) Constructing an engineered evapotranspiration cover over the 92-Acre Area; (2) Installing use restriction (UR) warning signs, concrete monuments, and subsidence survey monuments; (3) Establishing vegetation on the cover; (4) Implementing a UR; and (5) Implementing post-closure inspections and monitoring. The Closure in Place with Administrative Controls alternative meets all requirements for the technical components evaluated, fulfills all applicable federal and state regulations for closure of the site, and will minimize potential future exposure pathways to the buried waste at the site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Closure Report for Corrective Action Unit 544: Cellars, Mud Pits, and Oil Spills, Nevada National Security Site, Nevada, Revision 0 with ROTC 1

This Closure Report (CR) presents information supporting the closure of Corrective Action Unit (CAU) 544: Cellars, Mud Pits, and Oil Spills, Nevada National Security Site, Nevada. This CR complies with the requirements of the Federal Facility Agreement and Consent Order that was agreed to by the State of Nevada; U.S. Department of Energy (DOE), Environmental Management; U.S. Department of Defense; and DOE, Legacy Management. The corrective action sites (CASs) within CAU 544 are located within Areas 2, 7, 9, 10, 12, 19, and 20 of the Nevada National Security Site. Corrective Action Unit 544 comprises the following CASs: • 02-37-08, Cellar & Mud Pit • 02-37-09, Cellar & Mud Pit • 07-09-01, Mud Pit • 09-09-46, U-9itsx20 PS #1A Mud Pit • 10-09-01, Mud Pit • 12-09-03, Mud Pit • 19-09-01, Mud Pits (2) • 19-09-03, Mud Pit • 19-09-04, Mud Pit • 19-25-01, Oil Spill • 19-99-06, Waste Spill • 20-09-01, Mud Pits (2) • 20-09-02, Mud Pit • 20-09-03, Mud Pit • 20-09-04, Mud Pits (2) • 20-09-06, Mud Pit • 20-09-07, Mud Pit • 20-09-10, Mud Pit • 20-25-04, Oil Spills • 20-25-05, Oil Spills The purpose of this CR is to provide documentation supporting the completed corrective actions and data confirming that the closure objectives for CASs within CAU 544 were met. To achieve this, the following actions were performed: • Review the current site conditions, including the concentration and extent of contamination. • Implement any corrective actions necessary to protect human health and the environment. • Properly dispose of corrective action and investigation wastes. • Document Notice of Completion and closure of CAU 544 issued by the Nevada Division of Environmental Protection.

54 ENVIRONMENTAL SCIENCES↗

UCAC3 PIXEL PROCESSING

The third US Naval Observatory CCD Astrograph Catalog, UCAC3, was released at the IAU General Assembly on 2009 August 10. It is a highly accurate, all-sky astrometric catalog of about 100 million stars in the R = 8-16 mag range. Recent epoch observations are based on over 270,000 CCD exposures, which have been re-processed for the UCAC3 release applying traditional and new techniques. Challenges in the data have been high dark current and asymmetric image profiles due to the poor charge transfer efficiency of the detector. Non-Gaussian image profile functions were explored and correlations are found for profile fit parameters with properties of the CCD frames. These were utilized to constrain the image profile fit models and adequately describe the observed point-spread function of stellar images with a minimum number of free parameters. Using an appropriate model function, blended images of double stars could be fit successfully. UCAC3 positions are derived from two-dimensional image profile fits with a five-parameter, symmetric Lorentz profile model. Internal precisions of about 5 mas per coordinate and single exposure are found, which are degraded by the atmosphere to about 10 mas. However, systematic errors exceeding 100 mas are present in the x, y data which have been corrected in the astrometric reductions following the x, y data reduction step described here.

79 ASTRONOMY AND ASTROPHYSICS↗

Erratum to: Hadron transverse momentum distributions in muon deep inelastic scattering at 160 GeV/ $$c$$ c

This paper is an erratum to a previous paper (EPJC 73 (2013) 2531) published by C. Adolph et al. (The COMPASS Collaboration) using a data sample taken in 2004. In the course of the ongoing analysis of the more recent 2006 data sample, and following some additional hints we identified a problem in the analysis of the 2004 data presented in EPJC 73 (2013) 2531. The acceptance correction for the 2004 data sample did not properly account for the use of semi-inclusive triggers on top of the inclusive triggers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Corrective Action Decision Document/Corrective Action Plan for the 92-Acre Area and Corrective Action Unit 111: Area 5 WMD Retired Mixed Waste Pits, Nevada National Security Site, Nevada (Rev.1)

This Corrective Action Decision Document/Corrective Action Plan (CADD/CAP) has been prepared for the 92-Acre Area, the southeast quadrant of the Radioactive Waste Management Site, located in Area 5 of the Nevada National Security Site (NNSS). The 92-Acre Area includes Corrective Action Unit (CAU) 111, 'Area 5 WMD Retired Mixed Waste Pits.' Data Quality Objectives (DQOs) were developed for the 92-Acre Area, which includes CAU 111. The result of the DQO process was that the 92-Acre Area is sufficiently characterized to provide the input data necessary to evaluate corrective action alternatives (CAAs) without the collection of additional data. The DQOs are included as Appendix A of this document. This CADD/CAP identifies and provides the rationale for the recommended CAA for the 92-Acre Area, provides the plan for implementing the CAA, and details the post-closure plan. When approved, this CADD/CAP will supersede the existing Pit 3 (P03) Closure Plan, which was developed in accordance with Title 40 Code of Federal Regulations (CFR) Part 265, 'Interim Status Standards for Owners and Operators of Hazardous Waste Treatment, Storage, and Disposal Facilities.' This document will also serve as the Closure Plan and the Post-Closure Plan, which are required by 40 CFR 265, for the 92-Acre Area. After closure activities are complete, a request for the modification of the Resource Conservation and Recovery Act Permit that governs waste management activities at the NNSS will be submitted to the Nevada Division of Environmental Protection to incorporate the requirements for post-closure monitoring. Four CAAs, ranging from No Further Action to Clean Closure, were evaluated for the 92-Acre Area. The CAAs were evaluated on technical merit focusing on performance, reliability, feasibility, safety, and cost. Based on the evaluation of the data used to develop the conceptual site model; a review of past, current, and future operations at the site; and the detailed and comparative analysis of the potential CAAs, Closure in Place with Administrative Controls is the preferred CAA for the 92-Acre Area. Closure activities will include the following: (1) Constructing an engineered evapotranspiration cover over the 92-Acre Area; (2) Installing use restriction (UR) warning signs, concrete monuments, and subsidence survey monuments; (3) Establishing vegetation on the cover; (4) Implementing a UR; and (5) Implementing post-closure inspections and monitoring. The Closure in Place with Administrative Controls alternative meets all requirements for the technical components evaluated, fulfills all applicable federal and state regulations for closure of the site, and will minimize potential future exposure pathways to the buried waste at the site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Self timed data sampler

A sampling circuit automatically resamples the data from another timing domain until the sampled data is represented correctly in the new domain by assuring that no metastable states exist. If a metastable state exists, a sampling signal recirculates through the sampling circuit until the metastable state no longer exists. A comparison of input data to sampled data is used to determine the existence of a metastable state.

42 ENGINEERING↗

Exploration and Analysis of Legacy Data at the Hanford Site Using PHOENIX - 19044

Radioactive contaminants pose risks to human health and the environment. These risks are influenced by factors such as disposal/release and transport mechanisms, location in the environment, potential exposure receptors, and the presence of comingled contaminants. Understanding the behavior, transport, and distribution of radionuclides in the environment is essential to facilitating risk-informed decision-making related to remedial design, action, and monitoring. These decisions are based on significant amounts of complex data that must be accessed, integrated, and analyzed to effectively evaluate data and formulate appropriate conclusions and recommendations. Often, data volume, complexity, and legacy access issues pose severe challenges for analysts, regulators, and stakeholders interested in evaluating scientific data to support decision-making. To address these challenges at the U.S. Department of Energy Hanford Site, Pacific Northwest National Laboratory (PNNL) has developed PHOENIX (PNNL-Hanford Online Environmental Information exchange) to facilitate risk-informed decision-making by streamlining investigative and analytical processes through the integration and visualization of previously isolated datasets created under distinct regulatory or operational regimes, each serving a specific purpose. With the large volume of data dispersed across many Hanford environmental databases, finding the correct sources of relevant data, accessing them, and relating them in a meaningful way can prove challenging and time consuming. By analyzing Hanford databases, performing substantial optimization using modern data processing methods and developing extensive queries on the refactored data, PHOENIX enables users to access, integrate, display, visualize, and retrieve data that would have been historically unfeasible to examine. The data and information accessible through PHOENIX help inform remediation-related assessments and evaluations, predict and quantify the risks that radioactive and chemical contaminants pose to human health and the environment, and communicate this information to decision makers responsible for risk-based remediation actions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Speed and Memory Improvements to MCNP6 Delayed-Gamma Line Treatment

The delayed-gamma (DG) line-emission (line) sampling was first introduced into MCNPX in 2005. At the time, storage demands for problems with large numbers of DG lines was a major concern. In order to accommodate large amounts of line data while keeping the memory footprint of such a problem from exceeding memory limits, complicated logic was included to sift through various storage options. In mid-2015 concerns arose over the adequacy of the MCNP6 DG source option (inherited from MCNPX) with line sampling for modeling high-fidelity problems. One indication that there was a problem came when studying the MCNP6 produced DG spectra of U-238 and its progeny using high-fidelity spectroscopic tallies when compared to DG line amplitudes directly from ENDF/B-VII.1 emission data. Despite producing a correct integral number of gammas, the comparison to ENDF data showed a broadening in the energy lines and a reduction in the amplitude of more prominent lines. It was later found that the cause of this broadening was one of the memory-saving techniques used to store DG line data when problems required many DG lines. Specifically, the DG lines were integrated into fine energy bins for sampling. When a DG line was to be sampled, a random number would be used to choose which energy bin to sample based on emission probability. Once chosen, a second random number was used to perform nearest-line sampling in that bin. The integration of lines led to an oversampling of low-probability lines, especially when in close proximity to high-probability lines. This treatment also caused a similar issue with the time-dependent behavior of DG line emission which occurred when low-probability lines were sampled near high probability lines with the former decay constant being used. The effect on time-dependent gamma production was demonstrated in analytic benchmarks performed by Weldon et al.. To address these issues a new gamma line storage and sampling treatment was introduced in 2015. This new treatment, stores gamma emission data in a line-by-line CDF which is sampled directly, thereby resolving both the line-broadening issue, and the time-dependence issue as was demonstrated by Tutt el al.. In addition, the new DG sampling treatment was written to use dynamically dimensioned storage arrays as opposed to large fixed-dimensioned arrays, as in the former treatment, and also makes more efficient use of line data that is stored by reducing or eliminating repeated data. As a result, storage arrays are generated only for DG data relevant to the problem being executed. The result should be a reduction in both memory requirements and runtime. However, these reductions could not be realized until the logic for the old treatment could be removed. This paper provides an update on recent work which has focused on the removal of the old DG sampling logic and attempts to quantify the memory reduction and speed up of selected problems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

λ/2 contamination in X-ray diffraction data – the impact of heavy atoms

The impact of very different values of f ' and f " and of absorption coefficients for the wavelengths λ and λ/2 for heavy elements, and the effect of the difference in wavelength dispersion on the profile of the corresponding Bragg reflections, are discussed with respect to the correction of diffraction data for λ/2 contamination. The impact on the results of four charge-density studies is discussed.

Chemistry↗

The emergent 1.1-1.7 μm spectrum of the exoplanet COROT-2B as measured using the Hubble space telescope

We have used Hubble/WFC3 and the G141 grism to measure the secondary eclipse of the transiting, very hot Jupiter CoRoT-2b in the 1.1-1.7 μm spectral region. We find an eclipse depth averaged over this band equal to 395{sub −45}{sup +69} parts per million, equivalent to a blackbody temperature of 1788 ± 18 K. We study and characterize several WFC3 instrumental effects, especially the 'hook' phenomenon described by Deming et al. We use data from several transiting exoplanet systems to find a quantitative relation between the amplitude of the hook and the exposure level of a given pixel. Although the uncertainties in this relation are too large to allow us to develop an empirical correction for our data, our study provides a useful guide for optimizing exposure levels in future WFC3 observations. We derive the planet's spectrum using a differential method. The planet-to-star contrast increases to longer wavelength within the WFC3 bandpass, but without water absorption or emission to a 3σ limit of 85 ppm. The slope of the WFC3 spectrum is significantly less than the slope of the best-fit blackbody. We compare all existing eclipse data for this planet to a blackbody spectrum, and to spectra from both solar abundance and carbon-rich (C/O = 1) models. A blackbody spectrum is an acceptable fit to the full data set. Extra continuous opacity due to clouds or haze, and flattened temperature profiles, are strong candidates to produce quasi-blackbody spectra, and to account for the amplitude of the optical eclipses. Our results show ambiguous evidence for a temperature inversion in this planet.

79 ASTRONOMY AND ASTROPHYSICS↗

Geotech Smart24 data acquisition system input terminated noise seismic response adjusted test : StreckeisenSTS2-low and high gain, Guralp CMG3T and Geotech GS13 seismometers.

Sandia National Laboratories has tested, evaluated and reported on the Geotech Smart24 data acquisition system with active Fortezza crypto card data signing and authentication in SAND2008-. One test, Input Terminated Noise, allows us to characterize the self-noise of the Smart24 system. By computing the power spectral density (PSD) of the input terminated noise time series data set and correcting for the instrument response of different seismometers, the resulting spectrum can be compared to the USGS new low noise model (NLNM) of Peterson (1996), and determine the ability of the matched system of seismometer and Smart24 to be quiet enough for any general deployment location. Four seismometer models were evaluated: the Streckeisen STS2-Low and High Gain, Guralp CMG3T and Geotech GS13 models. Each has a unique pass-band as defined by the frequency band of the instrument corrected noise spectrum that falls below the new low-noise model.

99 GENERAL AND MISCELLANEOUS↗

Scatter correction for cone-beam CT in radiation therapy

Cone-beam CT (CBCT) is being increasingly used in modern radiation therapy for patient setup and adaptive replanning. However, due to the large volume of x-ray illumination, scatter becomes a rather serious problem and is considered as one of the fundamental limitations of CBCT image quality. Many scatter correction algorithms have been proposed in literature, while a standard practical solution still remains elusive. In radiation therapy, the same patient is scanned repetitively during a course of treatment, a natural question to ask is whether one can obtain the scatter distribution on the first day of treatment and then use the data for scatter correction in the subsequent scans on different days. To realize this scatter removal scheme, two technical pieces must be in place: (i) A strategy to obtain the scatter distribution in on-board CBCT imaging and (ii) a method to spatially match a prior scatter distribution with the on-treatment CBCT projection data for scatter subtraction. In this work, simple solutions to the two problems are provided. A partially blocked CBCT is used to extract the scatter distribution. The x-ray beam blocker has a strip pattern, such that partial volume can still be accurately reconstructed and the whole-field scatter distribution can be estimated from the detected signals in the shadow regions using interpolation/extrapolation. In the subsequent scans, the patient transformation is determined using a rigid registration of the conventional CBCT and the prior partial CBCT. From the derived patient transformation, the measured scatter is then modified to adapt the new on-treatment patient geometry for scatter correction. The proposed method is evaluated using physical experiments on a clinical CBCT system. On the Catphan(c)600 phantom, the errors in Hounsfield unit (HU) in the selected regions of interest are reduced from about 350 to below 50 HU; on an anthropomorphic phantom, the error is reduced from 15.7% to 5.4%. The proposed method is attractive in applications where a high CBCT image quality is critical, for example, dose calculation in adaptive radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing Heterogeneity of Surface Water Temperature Following Stream Restoration and a High-Intensity Fire from Thermal Imagery

Thermal heterogeneity of rivers is essential to support freshwater biodiversity. Salmon behaviorally thermoregulate by moving from patches of warm water to cold water. When implementing river restoration projects, it is essential to monitor changes in temperature and thermal heterogeneity through time to assess the impacts to a river’s thermal regime. Lightweight sensors that record both thermal infrared (TIR) and multispectral data carried via unoccupied aircraft systems (UASs) present an opportunity to monitor temperature variations at high spatial (<0.5 m) and temporal resolution, facilitating the detection of the small patches of varying temperatures salmon require. Here, we present methods to classify and filter visible wetted area, including a novel procedure to measure canopy cover, and extract and correct radiant surface water temperature to evaluate changes in the variability of stream temperature pre- and post-restoration followed by a high-intensity fire in a section of the river corridor of the South Fork McKenzie River, Oregon. We used a simple linear model to correct the TIR data by imaging a water bath where the temperature increased from 9.5 to 33.4 °C. The resulting model reduced the mean absolute error from 1.62 to 0.35 °C. We applied this correction to TIR-measured temperatures of wetted cells classified using NDWI imagery acquired in the field. We found warmer conditions (+2.6 °C) after restoration (p < 0.001) and median absolute deviation for pre-restoration (0.30) to be less than both that of post-restoration (0.85) and post-fire (0.79) orthomosaics. In addition, there was statistically significant evidence to support the hypothesis of shifts in temperature distributions pre- and post-restoration (KS test 2009 vs. 2019, p < 0.001, D = 0.99; KS test 2019 vs. 2021, p < 0.001, D = 0.10). Moreover, we used a Generalized Additive Model (GAM) that included spatial and environmental predictors (i.e., canopy cover calculated from multispectral NDVI and photogrammetrically derived digital elevation model) to model TIR temperature from a transect along the main river channel. This model explained 89% of the deviance, and the predictor variables showed statistical significance. Collectively, our study underscored the potential of a multispectral/TIR sensor to assess thermal heterogeneity in large and complex river systems.

Barker, Matthew I. (ORCID:0000000252864930)↗

Acquisition and registration of aerial video imagery of urban traffic

The amount of information available about urban traffic from aerial video imagery is extremely high. Here we discuss the collection of such video imagery from a helicopter platform with a low-cost sensor, and the post-processing used to correct radial distortion in the data and register it. The radial distortion correction is accomplished using a Harris model. The registration is implemented in a two-step process, using a globally applied polyprojective correction model followed by a fine scale local displacement field adjustment. The resulting cleaned-up data is sufficiently well-registered to allow subsequent straight-forward vehicle tracking.

99 GENERAL AND MISCELLANEOUS↗

The OpenSHMEM Analyzer

The OpenSHMEM Analyzer is a compiler-based tool that can help users detect errors and provide useful analyses about their OpenSHMEM applications. The tool is built on top of the OpenUH compiler (a branch of Open64 compiler) and presents OpenSHMEM information as feedback to the user. Some of the analyses it provides include checks for correct usage of symmetric variables in OpenSHMEM calls, out-of-bounds checks for symmetric data, checks for the correct initialization of pointers to symmetric data, and symmetric data alias information.

Hernandez, Oscar↗

Cosmic-Ray Moisture Probe on North Slope of Alaska Field Campaign Report

In September of 2014 a wide-area snow monitoring device was installed at the U.S. Department of Energy (DOE)’s Barrow, Alaska Atmospheric Radiation Measurement (ARM) Climate Research Facility site. The device is special in that it uses measurements of cosmic-ray neutrons as a proxy for snow water equivalent (SWE) depth. A unique characteristic of the technology is that it integrates over a wide area (as much as 40 ha), in contrast to conventional ground-based technologies, which essentially give point samples. Conventional point-scale technologies are problematic in the Arctic, both because extreme weather conditions are taxing on equipment, and because point measurements can fail to accurately characterize the average SWE over a larger area, even when excellent precision is obtained. The sensor installed in Barrow is, by far, the northernmost of a constellation of sites that makeup the U.S. COsmic ray Soil Moisture Observing System (COSMOS). The sensor is used for SWE measurements in winter and soil moisture measurements in summer. The ability of this type of sensor to operate in the Arctic had not been verified until now. The cosmic-ray sensor was installed on a tripod located approximately 150 m south of the ARM User Facility (Figure 1), and within boundaries of land managed by the ARM Facility. The sensor consists of both “bare” and “moderated” channels, where the moderated channel is the primary output used to calculate SWE. A QDL2100 data logger with pressure sensor was located inside of the User Facility, and a Campbell CS215 temperature and humidity sensor was attached to a rail on the upper deck of the User Facility, to enable near-real-time absolute humidity corrections to the data. The cosmic-ray sensors are connected to the data logger using an armored Cat5e cable that lies on top of the tundra. Data are retrieved hourly via Iridium satellite link.

"North Slope of Alaska, Barrow, soil moisture, cos↗