Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “core sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Core Analysis E-Reports Produced for the Southwest Regional Partnership on Carbon Sequestration for Wells 13-10A, 13-14, and 32-8 of the Farnsworth Unit, Texas

The submission is three electronic reports (e-reports) produced by Terra Tek, a former Schlumberger company, for and under the oversight of the Southwest Regional Partnership on Carbon Sequestration (SWP). The SWP designed and implemented a coring and core analysis program in conjunction with the previous field operator Chaparral Energy, L.L.C. The main SWP contacts who oversaw the coring and core analysis program, including geologic core descriptions and sample selection for testing by the Terra Tek, are listed below in the Authors section. The three reports are for Wells 13-10A, 13-14, and 32-8 of the Farnsworth Unit, TX, a site of the SWP's CO2 storage and enhanced oil recovery project. The e-reports include many data types that are not listed in full detail here, but may include: geomechanical, geochemical, and petrophysical measurements; white light and UV core photos; spectral gamma logs on the core; and Heterogeneous Rock Analysis logs. Fracture core review reports are included for Wells 13-14 and 32-8. The three e-reports each have many subfolders with the various types of data in spreadsheets, pdfs, image files, or other formats. The main e-reports for each well are listed by the well name. The sub-folder “E-Report” for each well has a Report.html file, which, when opened, will have hyperlinks to the various data sets and information. The files in the zipped folder will need to be extracted for the Report.html files to work properly. These authors thank Joseph Hall, a geologist formerly of Chaparral Energy, L.L.C., for assistance in designing the coring program, his geologic expertise of the Farnsworth Unit, and his assistance with characterizing the core. Christopher Gillespie, of Terra Tek at the time, managed the myriad geomechanical, geochemical, and petrophysical measurements provided by Terra Tek for this project. The core from which the samples were collected for this project are housed at the Subsurface Data and Core Libraries of the New Mexico Bureau of Geology and Mineral Resources, Socorro, New Mexico, USA. Funding for this project is provided by the U.S. Department of Energy's (DOE) National Energy Technology Laboratory (NETL) through the Southwest Regional Partnership on Carbon Sequestration (SWP) under Award No. DE-FC26-05NT42591. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525. These e-reports describe objective technical results and analysis. Any subjective views or opinions that might be expressed in the reports do not necessarily represent the views of the US Department of Energy or the United States Government.

Caprock↗

Maia Mapper: high definition XRF imaging in the lab

Here, Maia Mapper is a laboratory μXRF mapping system for efficient elemental imaging of drill core sections serving minerals research and industrial applications. It targets intermediate spatial scales, with imaging of up to ~80 M pixels over a 500×150 mm 2 sample area. It brings together (i) the Maia detector and imaging system, with its large solid-angle, event-mode operation, millisecond pixel transit times in fly-scan mode and real-time spectral deconvolution and imaging, (ii) the high brightness MetalJet D2 liquid metal micro-focus X-ray source from Excillum, and (iii) an efficient XOS polycapillary lens with a flux gain ~15,900 at 21 keV into a ~32 μm focus, and (iv) a sample scanning stage engineered for standard drill-core sections. Count-rates up to ~3 M/s are observed on drill core samples with low dead-time up to ~1.5%. Automated scans are executed in sequence with display of deconvoluted element component images accumulated in real-time in the Maia detector. Application images on drill core and polished rock slabs illustrate Maia Mapper capabilities as part of the analytical workflow of the Advanced Resource Characterisation Facility, which spans spatial dimensions from ore deposit to atomic scales.

47 OTHER INSTRUMENTATION↗

Core-shell Si@TiO 2 nanosphere anode by atomic layer deposition for Li-ion batteries

Silicon (Si) is regarded as next-generation anode for high-energy lithium-ion batteries (LIBs) due to its high Li storage capacity (4200 mA h g -1 ). However, the mechanical degradation and resultant capacity fade critically hinder its practical application. In this regard, we demonstrate that nanocoating of Si spheres with a 3 nm titanium dioxide (TiO 2 ) layer via atomic layer deposition (ALD) can utmostly balance the high conductivity and the good structural stability to improve the cycling stability of Si core material. The resultant sample, Si@TiO 2 -3 nm core–shell nanospheres, exhibits the best electrochemical performance of all with a highest initial Coulombic efficiency and specific charge capacity retention after 50 cycles at 0.1C (82.39% and 1580.3 mA h g -1 ). In addition to making full advantage of the ALD technique, we believe that our strategy and comprehension in coating the electrode and the active material could provide a useful pathway towards enhancing Si anode material itself and community of LIBs.

25 ENERGY STORAGE↗

Rare earth elements and critical metal content of extracted landfilled material and potential recovery opportunities

Highlights: • Samples from multiple core drills were obtained from 4× landfill sites in the UK. • Each sample analysed for rare earth elements, critical metals and valuable metals. • Two stage microwave digestion method ensuring high yield. • High quantities of copper and aluminium were observed in the soil layers of landfill. • Across 4× landfills aluminium and copper present has a value of around $400 million. - Abstract: Rare earth elements (REEs), Platinum group metals (PGMs) and other critical metals currently attract significant interest due to the high risks of supply shortage and substantial impact on the economy. Their uses in many applications have made them present in municipal solid waste (MSW) and in commercial and industrial waste (C&I), since several industrial processes produce by-products with high content of these metals. With over 4000 landfills in the UK alone, the aim of this study was to assess the existence of these critical metals within landfills. Samples collected from four closed landfills in UK were subjected to a two-step acid digestion to extract 27 metals of interest. Concentrations across the four landfill sites were 58 ± 6 mg kg{sup −1} for REEs comprising 44 ± 8 mg kg{sup −1} for light REEs, 11 ± 2 mg kg{sup −1} for heavy REEs and 3 ± 1 mg kg{sup −1} for Scandium (Sc) and 3 ± 1.0 mg kg{sup −1} of PGMs. Compared to the typical concentration in ores, these concentrations are too low to achieve a commercially viable extraction. However, content of other highly valuable metals (Al and Cu) was found in concentrations equating to a combined value across the four landfills of around $400 million, which increases the economic viability of landfill mining. Presence of critical metals will mainly depend on the type of waste that was buried but the recovery of these metals through landfill mining is possible and is economically feasible only if additional materials (plastics, paper, metallic items and other) are also recovered for reprocessing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CHANDRA DISCOVERY OF 10 NEW X-RAY JETS ASSOCIATED WITH FR II RADIO CORE-SELECTED AGNs IN THE MOJAVE SAMPLE

The Chandra X-ray Observatory has proven to be a vital tool for studying high-energy emission processes in jets associated with active galactic nuclei (AGNs). We have compiled a sample of 27 AGNs selected from the radio flux-limited MOJAVE (Monitoring of Jets in AGNs with VLBA Experiments) sample of highly relativistically beamed jets to look for correlations between X-ray and radio emission on kiloparsec (kpc) scales. The sample consists of all MOJAVE quasars that have over 100 mJy of extended radio emission at 1.4 GHz and a radio structure of at least 3'' in size. Previous Chandra observations have revealed X-ray jets in 11 of 14 members of the sample, and we have carried out new observations of the remaining 13 sources. Of the latter, 10 have X-ray jets, bringing the overall detection rate to {approx}78%. Our selection criterion, which is based on highly compact, relativistically beamed jet emission and large extended radio flux, thus provides an effective method of discovering new X-ray jets associated with AGNs. The detected X-ray jet morphologies are generally well correlated with the radio emission, except for those displaying sharp bends in the radio band. The X-ray emission mechanism for these powerful FR II (Fanaroff-Riley type II) jets can be interpreted as inverse Compton scattering off of cosmic microwave background photons by the electrons in the relativistic jets. We derive viewing angles for the jets, assuming a non-bending, non-decelerating model, by using superluminal parsec scale speeds along with parameters derived from the inverse Compton X-ray model. We use these angles to calculate best-fit Doppler and bulk Lorentz factors for the jets, as well as their possible ranges, which leads to extreme values for the bulk Lorentz factor in some cases. When both the non-bending and non-decelerating assumptions are relaxed the only constraints on the kpc-scale jet from the Chandra and Very Large Array observations are an upper limit on the viewing angle, and a lower limit on the bulk Lorentz factor.

79 ASTRONOMY AND ASTROPHYSICS↗

Lunar nitrogen - Evidence for secular change in the solar wind

The lunar soil is an efficient trap for nitrogen in the solar wind. The concentration of nitrogen in lunar soils implies a flux of solar wind at least three times greater than that which is observed today. The implication is that the present-day flux is anomalously low. Soil samples from drill cores, and soil breccias excavated from buried levels of the regolith provide samples of ancient solar wind. From these samples it is apparent that the N-15/N-14 ratio in the solar wind has undergone a monotonic secular increase over the last 2.5 billion years, at a rate of about 15% per billion years. Nuclear reactions in the sun appear to be the most likely cause of the variation.

Clayton, R. N.↗

Phosphorus in foraminiferal sediments from North Atlantic Ridge cores and in pure limestones

Samples of foraminiferal ooze from two North Atlantic cores were cleaned and progressively dissolved. Most of the P, Fe, and Mn was released during the first of two reductive cleaning steps. Most of the remainder of these elements and most of the Ca were released during the final acid dissolution step. The P in these samples is present largely in Fe- and Mn-rich coatings, not as a constituent of the foraminiferal shells themselves. Our results are consistent with those of earlier studies. The concentration of P in carbonate oozes in which it is clearly associated with coatings is similar to that of modern calcareous sediments in general, and with that of reasonably pure limestones of all ages. Phosphorus is apparently associated with (Fe, Mn)-oxide coatings in many carbonate sediments. The rate of removal of P from the oceans as a constituent of such sediments depends on the rate of formation of (Fe, Mn) coatings, not on the rate of incorporation of P into calcium carbonate.

NASA Discipline Exobiology↗

Nevada Higher Education Benefits from US Department of Energy (DOE) Environmental Management (EM) Nevada Program's Transfer of Geologic Samples - 20442

The Nevada National Security Site (NNSS), formerly the Nevada Test Site, was the location of 100 historic atmospheric and 828 historic underground nuclear tests from 1951 to 1992. Related to this historic nuclear testing, geologic and hydrologic studies of the site were conducted utilizing the skills and the expertise of the U.S. Geological Survey (USGS) and national laboratories (Los Alamos National Laboratory, Lawrence Livermore National Laboratory), who were principal in leading the development of weapons and were responsible for specific underground testing programs. The subsurface samples and technical/scientific data associated with NNSS geologic studies (past and present) are preserved and stored at the USGS Mercury Core Library and Data Center located at the NNSS. Currently, the facility stores over 2,000,000 linear feet of cores and cuttings from more than 2,600 drill holes that can be accessed for study. Most of the samples and historic geologic work was focused directly on subsurface geologic settings that relate directly to historic underground nuclear testing. Since 1992, the United States has observed a unilateral moratorium on full-scale nuclear testing, and the U.S. Department of Energy (DOE) Environmental Management (EM) Nevada Program is now responsible for hydrogeologic characterization of the potential impacts to the natural groundwater systems that may have resulted from historic underground nuclear tests. As part of this effort, the EM Nevada Program Underground Test Area (UGTA) Activity has drilled and completed over 58 deep (2,000 - 7,000 ft.) characterization wells, totaling in excess of 170,000 linear feet of cuttings and core samples. Cutting samples were collected as triplicate samples for each respective depth interval, to account for potential later nondestructive/destructive analysis and to preserve samples for regulatory purposes. Recently, it was recognized by the EM Nevada Program that opportunities may exist to reduce the cost and floor space required for the storage of geologic samples at the Mercury Core Library without impacting the integrity and representative nature of the samples necessary for project execution. An initiative was sponsored by EM Nevada Program to evaluate several options: 1) disposal of a portion of cuttings and cores in a land fill setting; 2) reduction in sample volume through skeletonizing core and cuttings from wells to a representative but much smaller number of samples; and 3) solicit potential interest in the academic community where other geoscientists could freely access the samples for studies. The Nevada state university system through the Nevada Bureau of Mines and Geology responded positively to the opportunity to receive these NNSS samples from the EM Nevada Program. In June 2019, approximately 17,000 geologic samples, representing greater than 170,000 linear feet of drilling and weighing over 20,000 pounds, were shipped from the NNSS to the Great Basin Science Sample and Records Library located in Reno, Nevada. The benefits resulting from this transfer were realized by the EM Nevada Program in terms of cost and space savings for geologic sample storage at the NNSS. The transfer did not impact the EM Nevada Program mission as access to representative geologic samples for regulatory and scientific purposes was preserved. Moreover, the Nevada Bureau of Mines and Geology acquired a significant resource of subsurface geologic samples and supporting technical data to support academic and scientific studies in a complex volcanic setting in southwest Nevada. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Two-polarity magnetization in the Manson impact breccia

A preliminary paleomagnetic study of the impact breccia matrix and clasts has produced surprising results--nearly antipodal normal and reversed polarity magnetic vectors are observed in different portions of the core. Near-antipodal magnetizations within a segment of matrix and within individual samples rule out core inversion as the explanation of the dual polarity. In both the dense and the sandy matrix breccias, the magnetizations of clasts and matrix within the same core segment are identical; this negative 'conglomerate test' indicates that magnetization originated after impact. Paleomagnetic study of the Manson Impact Structure is an attempt to refine the Ar-40/Ar-39 age (65.7 +/- 1 m.y.) that suggests Manson to be a Cretaceous-Tertiary boundary impact. Refinement is possible because the boundary occurs within a reversed polarity interval (29R) of only 0.5 m.y. duration. The two breccia types in the Manson structure were both examined: one of a very dense matrix and apparently partially melted, and the breccia stratigraphically below it of granular or 'sandy' chloritic matrix. Samples were taken from the matrixes and a wide variety of clast compositions, including granite, diabase, gneiss, amphibolite, and melted granite. Currently, measurements have been made on 22 samples, using 30-35 steps of either alternating field (AF) or thermal demagnetization.

Steiner, M. B.↗

Soil Water Retention and Hydraulic Conductivity Data and Model at Trail Creek in Taylor River Watershed, Colorado 2024-2025

This data package includes soil water retention and hydraulic conductivity data and model fitting results from measurements of ex-situ soil samples and in-situ soil sensors near Trail Creek. Soil water retention curves (SWRC) characterize soil water content as a function of soil water potential. SWRC depends on soil texture and pore structure and can be used to describe the constraints on biogeochemical processes in terms of soil water availability. In this data package, the sample identification follows the format TR-X-Y, where TR refers to Trail Creek, X is the treatment block identifier, and Y is the location identifier. Specifically, TR-ASCC1 is the control treatment block under the Adaptive Silviculture for Climate Change (ASCC) project, and TR-ASCC2 is the clear-cut treatment block. TR-ASCC-EHSn is associated with ecohydrology sites under the East-Taylor Watershed Community Observatory Sites directory, and TR-ASCC-ERTn (upslope n=1) are ecohydrology sites along the electrical resistivity tomography transects. The sample and location information can be found in metadata.csv, and the data from the soil sensors will be included in a future data version when the observation period becomes sufficiently long for data analysis. Sampling and Measurements Each sample falls into one of the two sampling methods – (1) intact cores or (2) soil sensors – and one of the two measurement methods – (a) laboratory or (b) in-situ. The intact cores were measured using the laboratory methods, which include measurements of soil water potential (HYPROP & WP4C, METER), saturated (KSAT, METER) and unsaturated hydraulic conductivity (HYPROP). The in-situ method uses a pair of co-located soil sensors to measure volumetric water content (TEROS12, METER) and soil water potential (TEROS21, METER), and the hydraulic conductivity was not measured. In comparison, the laboratory methods progress from full saturation to dry conditions, and the in-situ method includes both dry-to-wet and wet-to-dry cycles. The sampling and measurement methods for each sample can be found in metadata.csv, and more information about the measurements is detailed in the Methods section below. Models Retention and hydraulic conductivity data were fitted with four van-Genuchten-type models (specified by “model_name” column in the files): (1) traditional constrained van Genuchten model (“vG_constrained”), (2) traditional unconstrained van Genuchten model (“vG_unconstrained”), (3) PDI-variant of the constrained van Genuchten model (“vG_constrained_PDI”), and (4) PDI-variant of the unconstrained van Genuchten model (“vG_unconstrained_PDI”). The difference between the constrained (1: n) and the unconstrained (2: n, m) van Genuchten models is the number of pore-size distribution parameters in the model equations, giving the unconstrained model more degrees of freedom when fitting the data. Between the traditional and the PDI-variant models, model fitting differs the most at the dry end of the measurements. The traditional models allow infinite suction at the residual water content (water content does not drop below residual water content), and the PDI-variant models enforce a soil water potential value of pF=6.8 (~ -630 MPa) at oven-dryness (water content reaches 0). The inclusion of the van-Genuchten-type models is due to their common application. If other retention models are required, users can access the data in data.csv for further data fitting. More information about the models can be found in the Methods section below. Fitting Tasks The model fitting can be categorized into three levels of tasks (specified by “fitting_task” column in the files). Level 1 (“fit_retention”) only includes retention data fitting (the only level available for the in-situ method). Level 2 (“fit_retention_conductivity”) includes both retention and hydraulic conductivity data fitting, and the saturated hydraulic conductivity (Ks, a parameter of the hydraulic conductivity functions) is fixed by the measurements from KSAT. Level 3 (“fit_retention_conductivity_Ks”) also includes both retention and hydraulic conductivity data fitting, but Ks is a fitted parameter without the constraints from KSAT measurements. Among the same retention models (e.g. vG_constrained models of the same sample), level 1 should produce the best retention data fitting. Level 2 should have the highest misfit of the retention and hydraulic conductivity data, because the retention and hydraulic conductivity functions share common model parameters, and the unsaturated hydraulic conductivity (HYPROP) data fitting is subject to Ks measured independently by KSAT. Level 3 should have mid-level misfits of the retention and hydraulic conductivity data. While level 3 fits the hydraulic conductivity data better than level 2, the fitted Ks value might be unreasonable due to the lack of constraints at the wet end of the measurements. General recommendation when using this data package: (1) Choice of sampling methods: Intact cores might suffer from sample gaps that would lead to overestimation of Ks (sample gaps can be inferred from the “soil_sample_volume” column in metadata.csv when the value is < 249). In-situ method has higher uncertainty in characterizing the wet end of the SWRC because of sensor limitations and the difficulty in reaching full saturation under natural conditions. (2) Choice of fitting tasks: When only retention data is needed, level 1 (“fit_retention”) should be prioritized. When both retention and hydraulic conductivity data are needed, level 2 (“fit_retention_conductivity”) could be prioritized. (3) Choice of models: This could depend on what the downstream models call for. If no specific model is required, model misfit could be used as a ranking criterion. Model misfit values in terms of RMSE can be found in model_parameters.csv. The following files are included in this data package: (1) metadata.csv – This file includes the general information of each sample, including location (description, geocoordinates, elevation), sampling and measurements details (method, depth, time or period, volume, instruments), and soil physical properties (bulk density, saturated hydraulic conductivity, only applicable to physical soil samples). (2) data.csv – This file includes soil water potential, volumetric water content, and unsaturated hydraulic conductivity data of each sample. Column “instrument” specifies the instrument (HYPROP, WP4C, or TEROS) used to perform the measurements. (3) model_fit.csv – This file includes soil water potential, volumetric water content, and unsaturated hydraulic conductivity fitted from the four models and three fitting tasks. Column “model_name” specifies the retention model used, and “fitting_task” specifies the level of data fitting. Missing values indicate that the variable does not apply to that fitting task. (4) model_parameters.csv – This file includes the fitted model parameters, model misfits, and conventional water content thresholds (field capacity and wilting point) from the four models and three fitting tasks. Column “model_name” specifies the retention model used, and “fitting_task” specifies the level of data fitting. Missing values indicate that the parameter does not apply to that model and/or that fitting task. (5) data_Ks.csv – This file includes the saturated hydraulic conductivity measurements from KSAT. (6) /figure/*.png – This folder includes three quick visualizations of the data, retention model fitting results and misfits, and hydraulic conductivity model fitting results, misfits, and parameters. The model fitting results are separated by samples and fitting tasks and colored by models. Zoom-in required. (7) /hyprop/*.bdhx – This folder includes proprietary hyprop files that require the free Labros SoilView-Analysis (METER) to open. Users can explore data fitting using other retention models (i.e. Brooks-Corey, Fredlund-Xing, Kosugi, bimodal models). Be aware that Ks value is pre-entered under “Fitting tab, Conductivity functions parameters” for level 2 fitting. If the value is lost, please refer to metadata.csv under “Ks” column. (8) Six file-level metadata that summarize file, header, column, and variable information of all files. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

EARTH SCIENCE > LAND SURFACE > SOILS↗

Geology and Hydrothermal Alteration of the Raft River Geothermal System, Idaho

The Raft River geothermal system is located in southern Idaho, near the Utah-Idaho state boarder in the Raft River Valley. The field, which is owned and operated by U.S. Geothermal, has been selected as an EGS demonstration site by the U. S. Department of Energy. This paper summarizes ongoing geologic and petrologic investigations being conducted in support of this project. The reservoir is developed in fractured Proterozoic schist and quartzite, and Archean quartz monzonite cut by younger diabase intrusions. The basement complex was deformed during the mid Tertiary and covered by approximately 5000 ft of late Tertiary sedimentary and volcanic deposits. Listric normal faults of Cenozoic age disrupt the Tertiary deposits but do not offset the basement rocks. RRG-9, the target well, was drilled southwest of the main well field to a measured depth (MD) of 6089 ft. The well is deviated to the west and cased to a depth of 2316 ft MD. It penetrated the Proterozoic reservoir rocks at a depth of 5286 ft MD and encountered a maximum temperature of 139 degrees C. Bottomhole temperatures in other deep wells range from 133 to 149 degrees C. X-ray diffraction and thin section analyses are being conducted on samples from 5 deep wells, RRG- 1, 2, 3, 7 and 9, to determine the characteristics of the rock types and hydrothermal alteration within the geothermal system. Thin section analyses of samples from RRG-9 document the presence of strong alteration and brecciation at the contact between the Tertiary and basement complex. The Tertiary rocks consist of ash-flow tuffs, lava flows, tuffaceous siltstone, greywacke, and sandstone. No core is available from RRG-9 but core was obtained from RRG-3C. The sample is a brecciated and altered siltstone from the base of the Tertiary sequence and is similar to rocks at the base of the Tertiary deposits in RRG-9. Here, the results of thermal and quasi-static mechanical property measurements that were conducted on the core sample are presented.

Jones, Clay↗

Data Package of Samples Collected for Hydrogeologic and Geochemical Characterization: 300 Area RI/FS Sediment Cores

This is a data package for sediment samples received from the 300 FF 5 OU. This report was prepared for CHPRC. Between August 16, 2010 and April 25, 2011 sediment samples were received from 300-FF-5 for geochemical studies. The analyses for this project were performed at the 331 building located in the 300 Area of the Hanford Site. The analyses were performed according to Pacific Northwest National Laboratory (PNNL) approved procedures and/or nationally recognized test procedures. The data sets include the sample identification numbers, analytical results, estimated quantification limits (EQL), and quality control data. The preparatory and analytical quality control requirements, calibration requirements, acceptance criteria, and failure actions are defined in the on-line QA plan 'Conducting Analytical Work in Support of Regulatory Programs' (CAW). This QA plan implements the Hanford Analytical Services Quality Assurance Requirements Documents (HASQARD) for PNNL.

300 Area, Charaterization, Sediment↗

Miniature Piezoelectric Shaker Mechanism for Autonomous Distribution of Unconsolidated Sample to Instrument Cells

To perform in-situ measurements on Mars or other planetary bodies many instruments require powder produced using some sampling technique (drilling/coring) or sample processing technique (core crushing) to be placed in measurement cells. This usually requires filling a small sample cell using an inlet funnel. In order to minimize cross contamination with future samples and ensure the sample is transferred from the funnel to the test cell with minimal residual powder the funnel is shaken. The shaking assists gravity by fluidizing the powder and restoring flow of the material. In order to counter cross contamination or potential clogging due to settling during autonomous handling a piezoelectric shaking mechanism was designed for the deposition of sample fines in instrument inlet funnels. This device was designed to be lightweight, consume low power and demonstrated to be a resilient solid state actuator that can be mechanically and electrically tuned to shake the inlet funnel. In the final design configuration tested under nominal Mars Ambient conditions the funnel mechanism is driven by three symmetrically mounted piezoelectric flexure actuators that are out of the funnel support load path. The frequency of the actuation can be electrically controlled and monitored and mechanically tuned by the addition of tuning mass on the free end of the actuator. Unlike conventional electromagnetic motors these devices are solid state and can be designed with no macroscopically moving parts. This paper will discuss the design and testing results of these shaking mechanisms.

powder movement↗

CRITICAL MINERAL PARTITIONING IN COAL-HOSTED CLAYS OF THE POWDER RIVER BASIN, WY DETERMINED BY SEQUENTIAL EXTRACTION

Increasing demand for a more robust domestic supply of rare earth elements (REE) and critical minerals (CM) has led to significant investigation into unconventional sources. Coal and coal byproducts from the Powder River Basin (PRB) of Wyoming are potential sources of REE and CM. The association between strategic metals and their mineral hosts has important implications for extractability. Samples of overburden, underclays, and clay-rich partings were selected for analysis from core and bucket samples from three PRB coal mines. Quartz, illite, and kaolinite-group minerals are abundant in clay-rich portions of the PRB coal strata. We performed a five-step sequential extraction to constrain critical metal partitioning in samples of overburden and underclays (n=10). Unlike the occurrences of REE in other clay deposits, insignificant amounts of total REE + Y (TREY) were recovered in the ion-exchangeable fraction (< 0.5 ppm). A significant amount of TREY was leached from the acid-soluble fraction by 0.1M HCl, suggesting REE may be tied up within crystal lattices rather than sorbed to clay surfaces. The acid-soluble fraction contained between 3 and 250 ppm TREY, with an average TREY concentration of 60 ppm. Relative standard deviations for each extraction step were generally < ±10%. Whole-rock samples (n=72) contained greater TREY enrichment in overburden than in underclays and partings, however, the opposite is true for other CM, such as Ti and V. Other locations in the PRB show different enrichment trends. Our findings supplement a broader effort to couple REE and CM extraction with existing domestic coal production and contribute to the fundamental understanding of how these metals concentrate in low-temperature basin environments.

Stuart, Sophia↗

Voltage-Current Behavior of a Superconducting STAR ® Wire in a 6-Around-1 Cable Configuration

A 6-around-1 transposed cable using superconducting STAR® wires can be useful for future circular collider applications. We made three cable samples using single STAR® wires with a diameter of 1.3 mm. The first two samples, made with a cabling machine, used STAR® wires consisting of a 0.7 mm diameter Nb-Ti core. The third cable sample was manually wound and used a STAR® wire made with a 0.81 mm diameter Cu core. The first sample showed severe degradation after the cable was bent to a 75 mm radius. The current-carrying capability of the innermost and outermost REBCO tapes in the STAR® wire degraded by 42% to 98% and the middle REBCO tapes remained intact. This was also the case for the second and straight cable sample. After fabrication of the third cable sample, we observed only about 5% reduction in the current along the wire, measured at different locations inside the terminations. Finally, the results indicate that the differences in architecture or fabrication of the STAR® wires could have caused differences in critical current retention after cabling.

6-around-1 cable↗

Isotope Ratio Method Analysis of the WWR-SM Reactor

In this paper, we use the Isotope Ratio Method (IRM) to estimate the total energy production of the Uzbekistan Institute of Nuclear Physics WWR-SM research reactor. The isotope ratio method is a technique for verifying the operational history of a nuclear reactor by measuring trace element isotope ratios in non-fuel reactor components. The isotope ratios in these components can then be directly related to cumulative energy production with standard reactor modeling methods. This method has been successfully demonstrated on several shutdown reactors in the past. The WWR-SM is a 10MW pool reactor that has been operating since 1959. In 2013, a Pacific Northwest National Laboratory (PNNL) team successfully removed a surface sample from the aluminum core shroud during a refueling outage. The sample was subjected to Secondary Ionization Mass Spectrometry (SIMS) analysis at PNNL in 2014. Our results show good agreement with the actual operating history of the reactor.

Nuclear archeology, isotope ratio method, nonproli↗

EVALUATION OF THE DURABILITY OF THE STRUCTURAL CONCRETE OF REACTOR BUILDINGS AT SRS

The Department of Energy (DOE) intends to close 100-150 facilities in the DOE complex using an in situ decommissioning (ISD) strategy that calls for grouting the below-grade interior volume of the structure and leaving the above-grade interior open or demolishing it and disposing of it in the slit trenches in E Area. These closures are expected to persist and remain stable for centuries, but there are neither facility-specific monitoring approaches nor studies on the rate of deterioration of the materials used in the original construction or on the ISD components added during closure (caps, sloped roofs, etc). This report will focus on the evaluation of the actual aging/degradation of the materials of construction used in the ISD structures at Savannah River Site (SRS) above grade, specifically P & R reactor buildings. Concrete blocks (six 2 to 5 ton blocks) removed from the outer wall of the P Reactor Building were turned over to SRNL as the first source for concrete cores. Larger cores were received as a result of grouting activities in P and R reactor facilities. The cores were sectioned and evaluated using microscopy, x-ray diffraction (XRD), ion chromatography (IC) and thermal analysis. Scanning electron microscopy shows that the aggregate and cement phases present in the concrete are consistent with the mix design and no degradation mechanisms are evident at the aggregate-cement interfaces. Samples of the cores were digested and analyzed for chloride ingress as well as sulfate attack. The concentrations of chloride and sulfate ions did not exceed the limits of the mix design and there is no indication of any degradation due to these mechanisms. Thermal analysis on samples taken along the longitudinal axis of the cores show that there is a 1 inch carbonation layer (i.e., no portlandite) present in the interior wall of the reactor building and a negligible carbonation layer in the exterior wall. A mixed layer of carbonate and portlandite extends deeper into the interior (2-3 inches) and exterior (1-2 inches) walls. This is more extensive than measured in previous SRS structures. Once the completely carbonated layer reaches the rebar that is approximately 2-3 inches into the concrete wall, the steel is susceptible to corrosion. The growth rate of the carbonated layer was estimated from current observations and previous studies. Based on the estimated carbonation rate, the steel rebar should be protected from carbonation induced corrosion for at least another 100 years. If degradation of these structures is dominated by the carbonation mechanism, the length of time before water intrusion is expected into the process room of P-reactor is estimated to be between 425-675 years.

36 MATERIALS SCIENCE↗

Pods: a Powder Delivery System for Mars In-situ Organic, Mineralogic and Isotopic Analysis Instruments

Many Mars in situ instruments require fine-grained high-fidelity samples of rocks or soil. Included are instruments for the determination of mineralogy as well as organic and isotopic chemistry. Powder can be obtained as a primary objective of a sample collection system (e.g., by collecting powder as a surface is abraded by a rotary abrasion tool (RAT)), or as a secondary objective (e.g, by collecting drill powder as a core is drilled). In the latter case, a properly designed system could be used to monitor drilling in real time as well as to deliver powder to analytical instruments which would perform complementary analyses to those later performed on the intact core. In addition, once a core or other sample is collected, a system that could transfer intelligently collected subsamples of power from the intact core to a suite of analytical instruments would be highly desirable. We have conceptualized, developed and tested a breadboard Powder Delivery System (PoDS) intended to satisfy the collection, processing and distribution requirements of powder samples for Mars in-situ mineralogic, organic and isotopic measurement instruments.

Saha, C. P.↗