Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controllable loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Ontologies at Work: Analyzing Information Requirements for Model Predictive Control in Buildings

Model Predictive Control (MPC) has shown significant potential for improving energy efficiency, indoor air quality and occupant comfort of buildings. MPC-based control algorithms have also shown the ability to shift loads and optimize for multiple objectives, including but not limited to reducing the green-house gas emissions, energy costs and peak demand. However, one of the main implementation challenges of these control algorithms is the integration and configuration effort needed to deploy a supervisory MPC controller in a building. By assigning standardized references to information sources and control points in buildings, existing studies have shown that semantic ontologies and corresponding queries have the potential to ease the deployment of such controllers. Yet, the use of semantic information to ease the deployment processes of MPC controllers is still limited. In this paper, we review three MPC experiments and synthesize the information requirements of these optimization problems. We then turn to existing and upcoming semantic ontologies such as Brick, SAREF and ASHRAE Standard 223 to represent these requirements, evaluating their potential to support the implementation of an MPC controller. This investigation concludes with a discussion of existing opportunities and open questions that the community should explore to support more streamlined MPC implementations.

Prakash, Anand Krishnan↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation: Preprint

This paper presents the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., lost a large generation unit). The NLM engine is a central dispatch control system that provides high-speed cost-optimal coordination of a set of net loads (combination of generation and deferrable loads) connected to the same electrical network. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm. The experimental results indicate that the NLM engine can achieve the targeted system voltage and frequency and balance load and generation to serve the critical facility.

droop control↗

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE↗

A Smart and Flexible Microgrid with a Low-cost Scalable Open-source Controller (Final Report)

This report contains information regarding the activities carried out in the project "A Smart and Flexible Microgrid with a Low-cost Scalable Open-source Controller. The project aims at developing a community-based flexible microgrid (FMG) with smart grid features, including multiple utility feeders and dynamic boundaries that utilize intelligent switches and ultra-high-speed communication links already in a smart grid. The project also aims at developing a corresponding controller for such an FMG with low cost and high scalability. With distributed renewable energy resources (DERs) and the intelligent microgrid controller, the FMG will achieve aggressive emission reduction, increased energy use efficiency, and reliability improvement goals. The FMG and its controller design will be scalable for different geographic areas, load sizes, distributed generation source number and types, and even multiple MGs within a distribution electric power system. In order to achieve these project objectives, three main development tasks were carried out: FMG design, FMG controller development, and FMG controller testing. The fourth task was technology to market.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of Distributed Power Apportioning with Net Load Management Engine in Microgrids Using Power Hardware-in-the-Loop Simulation

This article presents the performance evaluation of ratio consensus-based distributed power apportioning engine along with centralized net load management (NLM) engine that ensures viable and stable operation of an islanded microgrid. Managing net load variability in a microgrid with high penetrations of uncertain renewable generation and ever-changing load demands is a crucial need in order to ensure viable and stable operation of the microgrid. Centralized “dispatch-rule”-based and/or multi-agent-based distributed control of distributed energy resources (DERs) in microgrid are well accepted for microgrid by adapting ANSI/ISA-95-based hierarchical control architecture. In the application where microgrid network has large geographical span with multiple DERs dispersed in the network, high penetration of uncertain renewable energy resources, and ever-changing load demands, a judicious selection of techniques/solutions for managing net-load resources for maintaining viability and stability is required. With this motivation, this article proposes a novel solution to mitigate the challenges by incorporating a mixed centralized NLM engine and distributed power apportioning control of DERs and loads. A power-hardware-in-the-loop (PHIL) -based experiment is conducted with the centralized NLM engine and the distributed power apportioning engine along with two commercial inverters. The experimental results validates the efficacy of the proposed method in ensuring viability and stability of a microgrid.

hardware-in-the-loop simulation↗

Levelized cost of charging of extreme fast charging with stationary LMO/LTO batteries

Extreme DC fast charging for electric vehicles (EVs) could be competitive with the internal combustion engine refueling experience and enable longer-distance travel, which could help with EV adoption and decarbonization, but these systems have high capital costs and extremely variable high-power demands. Behind-the-meter systems (BTMS) could support extreme-fast-charging (XFC) stations to increase nationwide adoption of EVs. Here, this study examines the optimal break-even levelized cost of charging (LCOC) across 96 BTMS scenarios to enable low-wait XFC stations providing 200 miles of charge in 10 min. This research simulates LCOC via synthetic XFC-capable EV loads, machine-learned battery life models from testing data, and nonlinear optimal controls, co-minimizing complex utility costs and battery replacements. An aggregate optimal BTMS design treating each EV load as equal likely gives an optimal LCOC per utility rate, the average of which is $\$$0.59/kWh. In addition, the sensitivity of optimal and off-optimal design factors, the long-life LMO/LTO chemistry, and optimized controls are analyzed. The battery control model, based on battery stressors to compare chemistries, optimizes LMO/LTO resting state of charge and cycle depth without compromising cost reduction, which enables greater flexibility in operation. The LCOC savings due to replacement reduction are small, up to $\$$0.035/kWh (6%), with an average of $\$$0.02/kWh (3.5%). Compared with gasoline stations, the aggregate XFC station design achieves comparable speed, experience of service, and cost at $\$$3.81/gal gasoline, showing that EVs can replace gasoline vehicles even for longer-distance travel.

25 ENERGY STORAGE↗

Investigation of modified uni-traveling carrier photodiode for cryogenic microwave photonic links

Quantum devices present the potential for unparalleled computing and communications capabilities; however, the cryogenic temperatures required to successfully control and read out many qubit platforms can prove to be very challenging to scale. Recently, there has emerged an interest in using microwave photonics to deliver control signals down to ultracold stages via optical fiber, thereby reducing thermal load and facilitating dense wavelength multiplexing. Photodetectors can then convert this optical energy to electrical signals for qubit control. The fidelity of the quantum operations of interest therefore depend heavily upon the characteristics of the photodiode, yet experimental demonstrations of fiber-coupled photodetection systems at low temperatures are relatively few in number, leaving important open questions regarding how specific detectors may perform in real-world cryogenic settings. In this work, we examine a highly linear modified uni-traveling carrier photodiode (MUTC-PD) under C-band illumination (1530–1565 nm) at three temperature regimes (300 K, 80 K, and ∼4 K) and multiple bias conditions. Our findings of reduced responsivity but preserved bandwidth are consistent with previous studies, while our saturation tests suggest a variety of potential applications for MUTC-PDs in cryogenic microwave photonics with and without electrical bias. Overall, our results should provide a valuable foundation for the continued and expanding use of this detector technology in quantum information processing.

47 OTHER INSTRUMENTATION↗

Anomaly Detection, Localization and Classification using Drifting Synchrophasor Data Streams

With ongoing automation and digitization of the electric power system, several Phasor Measurement Units(PMUs) have been deployed for monitoring and control. PMU data can have multiple anomalies, and many of the researchers in the past have concentrated on training machine/deep learning algorithms offline for anomaly detection over PMU data (i.e., not in real time). These machine/deep learning algorithms, when trained offline on a sample rather than a population of the dataset, fail to consider the dynamic behavior of the power grid in real-time, resulting in low accuracy. Considering the dynamic behavior of the power grid (e.g., change in load, generation, distributed energy resources (DERs) switching, network, controls), the definition of data anomalies varies in time and requires online training. A fundamental challenge is to enable online (i.e., real-time) training of machine/deep learning algorithms for anomaly detection over streaming PMU data. While machine/deep learning is often desirable to manage data streams, training a deep learning algorithm over streaming PMU data is nontrivial due to changes in data statistics caused by dynamic streaming data. This paper proposes PMUNET: a novel device-level deep learning-based data-driven approach for anomaly detection, localization, and classification over streaming PMU data, using online learning and multivariate data-drift detection algorithm .Two variants of PMUNET, Dynamic data Change Driven Learning (DCDL) and Continuity Driven Learning (CDL), are proposed and compared. DCDL aims to train the deep learning algorithm whenever the definition of anomaly changes due to the power grid dynamics. On the other hand, CDL continuously trains the deep learning algorithm over the PMU data-stream. The experimental results verify that DCDL outperforms CDL and other efficient anomaly detection methods over multiple events such as faults and load/ generator/capacitor/DERs variations/switching for IEEE 14 and 39 Bus test system as well as real PMU industrial data. The result verifies that DCDL variant of PMUNET improves over existing approach with a gain of 2% - 10% in terms of accuracy, false-positive rate, and false-negative rate.

adversarial deep learning↗

Reinforcement Learning‐Based Adaptation of Grid Following Inverter's Internal Controller to Networked Microgrids' Strengths

The varying topological configurations, generator commitments and dispatches, and dynamic load demand lead to changing system's strengths during the operations of networked microgrids. When the system's strengths significantly change, the fixed control gains at large devices may result in unsatisfactory system performance; this necessitates the tuning of the control gains at large devices to adapt to the changing system's strengths. In this paper, observer-based reinforcement learning (RL) is utilised to automatically tune the proportional-integral (PI) gains of phase lock loop (PLL) controller of grid-following (GFL) inverters to adapt to the changing strengths of microgrids and networked microgrids. The RL agent in this framework augments an observer predicting system's strengths, from which the RL control policy will adjust accordingly to tune the PLL controller's gains towards the system's strengths. Also, to enhance the control performance, the recently introduced Barrier function-based RL framework is leveraged for the design of reward function to prevent the high frequency nadir. An operational 26 kV electric distribution system, which is modelled as networked microgrids, is used to illustrate the need and effectiveness of the proposed RL-tuned control.

frequency response↗

Ethyl Formate Fumigation against Pineapple Mealybug, Dysmicoccus brevipes , a Quarantine Insect Pest of Pineapples

Pineapple mealybug, Dysmicoccus brevipes (Hemiptera: Pseudococcidae), is a significant pest in pineapple production and a key trade barrier. We explored the potential use of ethyl formate (EF) as a methyl bromide alternative for the postharvest fumigation of D. brevipes in imported pineapples. When treated at 8 °C for 4 h, EF fumigation was effective against D. brevipes with LCt 99 , the lethal concentration × time product of EF necessary to achieve 99% mortality of D. brevipes nymphs and adults at 64.2 and 134.8 g h/m 3 , respectively. Sorption trials conducted with 70 g/m 3 EF for 4 h at 8 °C using 7.5, 15 and 30% pineapple loading ratios ( w/v ) indicated that loading ratio lower than 30% is necessary to achieve the LCt 99 values required to control D. brevipes . In a scaled up trial using 1 m 3 chamber, EF fumigation with 70 g/m 3 for 4 h at 8 °C with 20% pineapple loading ratio ( w/v ) resulted in a complete control of D. brevipes treated. There were no significant differences in hue values, sugar contents, firmness, and weight loss between EF-treated and untreated pineapples. Our results suggest that EF is a promising alternative to methyl bromide fumigation for the postharvest phytosanitary disinfection of D. brevipes in pineapples.

59 BASIC BIOLOGICAL SCIENCES↗

A Platform-Independent X-ray Diffraction Diagnostic for Phase Transition Kinetics in Traditional and Synthetic Microstructure Materials (LDRD Project 213088 Final Report)

Pulsed-power generators using the magnetic loading technique are able to produce well-controlled continuous ramp compression of condensed matter for high-pressure equation-of-state studies. X-ray diffraction (XRD) data from dynamically compressed samples provide direct measurements of the elastic compression of the crystal lattice, onset of plastic flow, strength-strain rate dependence, structural phase transitions, and density of crystal defects such as dislocations. Here, we present a cost effective, compact X-ray source for XRD measurements on pulsed-power-driven ramp-loaded samples. This combination of magnetically-driven ramp compression of materials with single, short-pulse XRD diagnostic will be a powerful capability for the dynamic materials community. The success in fielding this new XRD diagnostic dramatically improves our predictive capability and understanding of rate-dependent behavior at or near phase transition. As Sandia plans the next-generation pulse-power driver platform, a key element needed to deliver new state-of-the-art experiments will be having the necessary diagnostic tools to probe new regimes and phenomena. These diagnostics need to be as versatile, compact, and portable as they are powerful. The development of a platform-independent XRD diagnostic gives Sandia researchers a new window to study the microstructure and phase dynamics of materials under load. This project has paved the way for phase transition research in a variety of materials with mission interest.

36 MATERIALS SCIENCE↗

Iterative Linearization for Phasor-Defined Optimal Power Dispatch

Optimal power flow (OPF) problems, which dispatch power targets to controllable generating units across a network, must generally account for non-convex constraints on power flow. Furthermore, adapting those problems so as to make them solvable with convex optimization techniques is an area of much academic and operational interest. In this paper, we present a method for solving OPF as a quadratic program by iteratively refining and re-initializing a linearized model of power flow based on the outputs of an associated nonlinear solver. The linear model on which we demonstrate this method is an adapted version of an approximation designed for use with unbalanced distribution networks. As an important benefit, the model allows for the explicit inclusion of nodal voltage phasor values in both the OPF problem's objective and its constraints, which opens the door to the idea of phasor-based control (PBC) design. We show in simulations on the IEEE 13-node test feeder that our method quickly converges to a set of phasor targets that are sufficiently precise for use in operations at the distribution level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nanocarrier-loaded block copolymer dual domain organogels

Loaded polymer gels are prevalent materials in the controlled release community and, fairly recently, have been formulated to include nanocarrier domains such as micelles and vesicles. One mechanism used to establish the solid-like characteristic of gels is block copolymer self-assembly, which can result in a system-spanning, physically-crosslinked network. Additionally, the combination of nanocarrier and crosslink domain presence offers gels with a rich nanoscale phase space capable of intricate macroscopic property tuning. The current manuscript provides an overview of nanocarrier-loaded block copolymer organogels wherein nanocarriers are reverse micelles formed by sodium dioctyl sulfosuccinate (AOT), the block copolymer is a styrenic ABA triblock copolymer, and the gel solvent is aliphatic mineral oil. This introductory overview starts by identifying the envelope in ternary phase space wherein nanocarrier-loaded block copolymer organogels form (2-49 wt% triblock copolymer and 8x10 -3 -1 wt% AOT). Next, a detailed nanostructural description of gels varying in AOT and triblock copolymer concentration is presented. The manuscript concludes with demonstration of AOT reverse micelle release and gel uniaxial tensile response for gels containing 0-1 wt% AOT and 5-40 wt% styrenic triblock copolymer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data Analysis Approach for Large Data Volumes in a Connected Community

Recent advancements within smart neighborhoods where utilities are enabling automatic control of appliances such as heating, ventilation, and air conditioning (HVAC) and water heater (WH) systems are providing new opportunities to minimize energy costs through reduced peak load. This requires systematic collection, storage, management, and in-memory processing of large volumes of streaming data for fast performance. In this paper, we propose a multi-tier layered IoT software framework that enables effective descriptive and predictive data analysis for understanding live operation of the neighborhood, fault identification, and future opportunities for further optimization of load curves. We then demonstrate how we achieve live situational awareness of the connected neighborhood through a suite of visualization components. Finally, we discuss a few analytic dashboards that address questions such as peak load reductions obtained due to optimization, customer preference for automatic control of appliances (do they override the automatic control of HVAC?, etc.). 1 1 This manuscript has been authored by UT-Battelle, LLC under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy. The United States Government retains and the publisher, by accepting the article for publication, acknowledges that the United States Government retains a nonexclusive, paid-up, irrevocable, world-wide license to publish or reproduce the published form of this manuscript, or allow others to do so, for United States Government purposes. The Department of Energy will provide public access to these results of federally sponsored research in accordance with the DOE Public Access Plan (http://energy.gov/downloads/doe-public-access-plan).

Chinthavali, Supriya↗

Real-Time Implementation of Smart Wireless Charging of On-Demand Shuttle Service for Demand Charge Mitigation

This paper presents a smart charge management strategy for an on-demand electric shuttle operating at the National Renewable Energy Laboratory (NREL) campus and supported by an inductive charger at the vehicle's waiting spot. A new control algorithm has been proposed for mitigating the demand charges incurred from the wireless charger. It monitors the shuttle, wireless charger, renewable energy generation, and other loads and regulates charging behavior for demand charge mitigation. Within the control algorithm, an energy prediction is made to estimate the mobility needs of the vehicle and maintain uninterrupted service during operation while still minimizing peak demand. The proposed controller is designed and optimized using a Simulink model for the entire system. It is then implemented and tested in real time at the NREL campus using online cloud services. Two vehicle-use cases' charge-sustaining and charge-depletion operation' are tested under different campus power profiles and drive cycles to assess the controller's performance. In this work, the proposed controller showed a robust performance under different driving scenarios, with high correlation between simulation and experimental data. The results show that proper demand response can be achieved, with an average of 94% reduction of charging loads during peak demand events.

33 ADVANCED PROPULSION SYSTEMS↗

Intelligent Control of Thermal Energy Storage in the Manufacturing Sector for Plant-Level Grid Response

Industrial facilities are seeking new strategies that help in providing savings mechanisms for demand charges. Demand charges are the charges incurred by industrial facilities as a result of power usage. Thermal energy storage has advanced significantly with lots of new applications, garnering the interest of many industrial facilities. These applications could be used to shave the industrial facilities’ peak electric demand and reduce their demand charges. This paper aims to demonstrate the efficacy of thermal energy storage in reducing demand charges and highlight new developments in the integration of smart control systems with thermal energy storage. The study compares energy consumption and peak demand for a facility equipped with and without thermal energy storage tanks using a fixed schedule for charging and discharging. Additionally, the paper examines the impact of incorporating a smart controller to determine when to charge and discharge the tank based on the facility’s real-time power usage and a given setpoint. The results indicate cost savings from the use of thermal energy storage tanks under two proposed scenarios, reflected in the reduced cost of power consumption for the studied facility. The incorporation of a smart controller with the thermal energy storage tank in the facility studied could provide estimated savings of 3.3% per year of power consumption charges, without considering the contribution of any incentives. The estimated savings provided by the fixed schedule scenario are 2.7% per year.

25 ENERGY STORAGE↗

Additive-Mixing Fuel Injection (AMFI): A device for robust control and improved performance of high-efficiency LTGC engines

Low-temperature gasoline combustion (LTGC) engines can provide high efficiencies with very low NOx and particulate emissions. Despite these major advantages, methods for controlling LTGC combustion timing, achieving robust autoignition, and good low-load performance have challenged the development of practical LTGC engines. A key reason is that the ideal reactivity of the fuel varies with operating conditions, with low-reactivity fuels working well at high loads and higher-reactivity fuels working better at low loads. This article introduces a new technique called Additive Mixing Fuel Injection (AMFI) that adjusts the reactivity of the gasoline to obtain good performance over the operating map. Moreover, AMFI can provide robust combustion-timing control because it precisely meters very small amounts (0.01–0.6 mm 3 ) of an ignition-enhancing additive into the fuel each engine cycle. The additive used was 2-ethylhexyl nitrate (EHN), a common, inexpensive diesel-fuel ignition improver, but other additives could be used. Because additive amounts are so small, a 2-gal reservoir would be sufficient for medium-duty applications with refilling only at service intervals of about 8000 mi. The AMFI system has been installed on a single-cylinder LTGC research engine and demonstrated to provide robust combustion-timing control over wide ranges of combustion phasing, fueling rate, intake boost, engine speed, and intake temperature. AMFI also increases the fuel’s reactivity sufficiently to greatly reduce or eliminate the need for charge heating, simplifying engine design and significantly increasing thermal efficiency and the maximum load at low-boost conditions. The nitrogen in the EHN produced a modest increase in NOx, but it was mitigated by lower intake temperatures, and NOx emissions remained very low. Finally, the additive increases the sensitivity of autoignition reactions to variations in the local fuel/air mixture within the charge. This allows the use of controlled fuel stratification for improved LTGC-engine performance, and its potential to improve low-load operation was demonstrated.

Dec, John E.↗

Two-Stage Deep Reinforcement Learning for Distribution System Voltage Regulation and Peak Load Management: Preprint

The growing integration of distributed solar photovoltaic (PV) in distribution systems could result in adverse effects during grid operation. This paper develops a soft actor critic-based deep reinforcement learning (SAC-DRL) solution to simultaneously control PV inverters and battery energy storage systems for voltage regulation and peak load demand shaving. The novel two-stage framework, featured with two different control agents, is applied for daytime and nighttime operation to enhance the control performance. Comparison results with other control methods on a real feeder in Western Colorado demonstrate that the proposed method can provide advanced voltage regulation with modest active power curtailment for peak demand reduction.

deep reinforcement learning↗