Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “consumption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Low Precision for Lower Energy Consumption: Preprint

Low-precision numeric types offer significant efficiency and energy benefits for computing applications. Mixed-precision algorithms, combining low and high precision types, maintain accuracy while improving performance. Despite advantages, there exist challenges on adapting existing mixed-precision algorithms to new technologies, such as new hardware architectures and new low-precision data types. This paper presents current challenges and opportunities to advance science in this domain targetting more energy efficient solutions.

energy efficiency↗

Method and system for dehumidification and atmospheric water extraction with minimal energy consumption

Methods, systems and devices for managing humidity within an HVAC system including a nanostructured desiccant porous material configured to adsorb water from an inlet stream at a first air pressure and to release water from that material when subjected to a second air pressure when the second air pressure is lower than the first air pressure is located within a particular location so as to allow for the passage of wet air over the materials and allow adsorption of the water on to the material. When coupled with a vacuum pump water can be collected and released from the materials and the system, regenerating the material for future use and removing water from a stream at a significantly lower cost than existing processes.

McGrail, Bernard P.↗

Water for electricity in India: A multi-model study of future challenges and linkages to climate change mitigation

This paper provides projections of water withdrawals and consumption for electricity generation in India through 2050. Based on the results from five energy-economic modeling teams, the paper explores the implications of economic growth, power plant cooling policies, and electricity CO2 emissions reductions on water withdrawals and consumption. To isolate modeling differences, the five teams used harmonized assumptions regarding economic and population growth, the distribution of power plants by cooling technologies, and withdrawals and consumption intensities. The results demonstrate the different but potentially complementary implications of cooling technology policies and efforts to reduce CO2 emissions. The application of closed-loop cooling technologies substantially reduces water withdrawals but increases consumption. The water implications of CO2 emissions reductions, depend critically on the approach to these reductions. Focusing on wind and solar power reduces consumption and withdrawals; a focus on nuclear power increases both; and a focus on hydroelectric power could increase consumptive losses through evaporation.

electricity generation↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Eco Look-Ahead Control of Battery Electric Vehicles and Roadway Grade Effects

Roadway grade is one of the major variables that affects a vehicle’s energy consumption. This study demonstrates the potential benefits of an eco look-ahead control for battery electric vehicles (BEVs). The proposed eco look-ahead controller was developed for the lead vehicle of a platoon of BEVs. The eco look-ahead control predicts the optimum speed and acceleration levels within a preset speed window to minimize energy consumption considering the instantaneous energy used and the regenerated energy. The developed BEV eco look-ahead control system integrates a BEV energy consumption model and a powertrain model to save fuel while maintaining vehicle speed within a user-specified window. In addition, the study demonstrates the effects of roadway grade on BEV energy consumption. The results show that the energy consumption of BEVs are significantly reduced on downhill roads compared with internal combustion engine vehicles owing to regenerative braking. Specifically, testing showed that BEVs could even produce extra energy on downhill roads. The study also tested the eco look-ahead control on an 18-km section of I-81 and found that the system produced savings of 8.51% and 26.88% in the uphill and downhill directions, respectively. This study demonstrated that regenerative energy in BEVs is a critical factor in energy efficiency and the developed eco look-ahead control significantly improved the energy efficiency for BEVs.

Engineering↗

Cumulative effects of piscivorous colonial waterbirds on juvenile salmonids: A multi predator-prey species evaluation

We investigated the cumulative effects of predation by piscivorous colonial waterbirds on the survival of multiple salmonid ( Oncorhynchus spp.) populations listed under the U.S. Endangered Species Act (ESA) and determined what proportion of all sources of fish mortality (1 –survival) were due to birds in the Columbia River basin, USA. Anadromous juvenile salmonids (smolts) were exposed to predation by Caspian terns ( Hydroprogne caspia ), double-crested cormorants ( Nannopterum auritum ), California gulls ( Larus californicus ), and ring-billed gulls ( L . delawarensis ), birds known to consume both live and dead fish. Avian consumption and survival probabilities (proportion of available fish consumed or alive) were estimated for steelhead trout ( O . mykiss ), yearling Chinook salmon ( O . tshawytscha ), sub-yearling Chinook salmon, and sockeye salmon ( O . nerka ) during out-migration from the lower Snake River to the Pacific Ocean during an 11-year study period (2008–2018). Results indicated that probabilities of avian consumption varied greatly across salmonid populations, bird species, colony location, river reach, and year. Cumulative consumption probabilities (consumption by birds from all colonies combined) were consistently the highest for steelhead, with annual estimates ranging from 0.22 (95% credible interval = 0.20–0.26) to 0.51 (0.43–0.60) of available smolts. The cumulative effects of avian consumption were significantly lower for yearling and sub-yearling Chinook salmon, with consumption probabilities ranging annually from 0.04 (0.02–0.07) to 0.10 (0.07–0.15) and from 0.06 (0.3–0.09) to 0.15 (0.10–0.23), respectively. Avian consumption probabilities for sockeye salmon smolts was generally higher than for Chinook salmon smolts, but lower than for steelhead smolts, ranging annually from 0.08 (0.03–0.22) to 0.25 (0.14–0.44). Although annual consumption probabilities for birds from certain colonies were more than 0.20 of available smolts, probabilities from other colonies were less than 0.01 of available smolts, indicating that not all colonies of birds posed a substantial risk to smolt mortality. Consumption probabilities were lowest for small colonies and for colonies located a considerable distance from the Snake and Columbia rivers. Total mortality attributed to avian consumption was relatively small for Chinook salmon (less than 10%) but was the single greatest source of mortality for steelhead (greater than 50%) in all years evaluated. Results suggest that the potential benefits to salmonid populations of managing birds to reduce smolt mortality would vary widely depending on the salmonid population, the species of bird, and the size and location of the breeding colony.

Evans, Allen F.↗

The Uniform Methods Project: Smart Thermostat Evaluation Protocol

A smart thermostat is an internet-connected device that controls home heating, ventilation, and air-conditioning (HVAC) equipment and can automatically adjust temperature set points to optimize performance and achieve energy savings. Smart thermostat features often include two way communication, occupancy detection (such as geofencing and occupancy sensors), schedule learning, and seasonal optimization algorithms. Smart thermostats can control most conventional HVAC systems, including central air conditioners, heat pumps, and forced air furnaces. Several types of residential utility programs offer smart thermostats as replacements measures. Working with smart thermostat vendors, utilities can offer separate optimization programs to produce energy savings beyond those achieved by installing a smart thermostat. From an evaluation perspective, smart thermostat programs have several noteworthy features. First, the energy savings from a smart thermostat may change over the life of the device. As a smart thermostat is connected to the internet, original equipment manufacturers can update the thermostat software to improve the thermostat's energy efficiency. Likewise, users can adjust the thermostat settings and schedules over time in response to changes in weather, thermal comfort, energy prices, or preferences for energy efficiency. Additionally, many thermostat manufacturers offer seasonal optimization programs that recommend changes or make minor, automated adjustments to the thermostat settings to improve energy efficiency. These opt-in programs are now standard offerings for many smart thermostat manufacturers and provided at no additional cost to users. The potential for software updates and continuous optimization and the evolving nature of user interactions mean future energy savings may differ from first-year savings and the energy savings of smart thermostats may need to be evaluated more than once. Second, smart thermostats often have small unit energy savings relative to a home's total energy consumption, especially in comparison to whole- home retrofit programs. This can make it difficult to detect the smart thermostat savings in billing or advanced metering infrastructure (AMI) meter consumption data. For example, as cooling loads in many regions average about 20% of annual electricity consumption, smart thermostat savings of 10% of cooling energy use would equate to a 2% reduction in home electricity consumption. Evaluators should use regression analysis of whole-home billing consumption or advanced metering infrastructure (AMI) meter consumption data to evaluate smart thermostat savings because, as explained at greater length below , these data are usually available to evaluators and regression can control for the impacts of weather and other potentially confounding factors on a home's energy consumption. Finally, as with other energy efficiency programs, participation in smart thermostat programs is self-selective. As discussed at greater length below , smart thermostat participants tend to be, among other things, younger, higher-income, and more likely to adopt electric vehicles (EVs) and internet connected devices than nonparticipants. These differences are often unobservable to the evaluator and correlated with a home's energy consumption, creating the potential for bias in estimating savings. Due to the small unit savings of thermostats, errors and biases from self-selection that may not be very consequential when evaluating a whole- home retrofits (e.g., ±2% of home electricity consumption) can have a major impact when evaluating the savings and cost-effectiveness of smart thermostat programs. A percentage point change in the estimated savings could affect the cost-effectiveness of a program. This means it is important for evaluators to assess and to minimize the potential for error from selection bias in estimating smart thermostat program savings. The Uniform Methods Project provides model protocols for determining energy savings and demand reductions that result from specific energy efficiency measures implemented through state and utility programs. In most cases, the measure protocols are based on a particular option identified by the International Performance Verification and Measurement Protocol ; however, this work provides a more detailed approach to implementing that option. Each chapter is written by technical experts in collaboration with their peers, reviewed by industry experts, and subject to public review and comment. The UMP protocols can be used by utilities, program administrators, public utility commissions, evaluators, and other stakeholders for both program planning and evaluation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Miscellaneous Electric Loads: Characterization and Energy Savings Potential

Over time, miscellaneous electric loads (MELs) are expected to increase both in magnitude and share of residential and commercial building energy consumption. This trend is most apparent in North America, but it is also occurring in Japan and Europe. However, the contribution of MELs to building energy use is not currently well understood, both because the products in this category are transforming rapidly and the definition and classification of MELs is ambiguous. This study estimated the national energy consumption of 36 MELs using best-available data and found them to comprise 12% of delivered electricity to the U.S. residential and commercial building sectors. If 26 of these MELs were replaced with the most energy-efficient product models available on the market, their energy consumption could be halved to 6% of delivered electricity. National energy models will better account for building energy consumption by incorporating the MELs data collected and analyzed for this study, leading to improved policy decisions.

Miscellaneous electric loads, Plug loads, Taxonomy↗

Performance and energy impact of OpenMP runtime configurations on power constrained systems

Energy consumption of an application has attained the same vitality as execution time in current HPC systems, primarily due to the massive energy consumption of these systems and consequently substantial energy bills. This fact forced software developers as well as hardware vendors to put an extensive focus on energy consumption. This focus becomes even more crucial in power constrained systems, where the amount of power dedicated to applications is limited. In such systems, finding the optimal balance between execution time and energy consumption has a significant impact on utilizing these systems efficiently. A programming model is a necessary layer where optimizations can be applied to find the optimal balance. OpenMP is a standard programming model for intra-node parallelism. In this paper, we give a detailed analysis of how to optimize the execution time and energy consumption of an OpenMP application using the OpenMP runtime environment at different power levels. We studied twenty-eight OpenMP parallel regions from five NAS Parallel Benchmark (NPB) applications. Based on the study, we show that for a given power level, a suitable selection of OpenMP runtime parameters can improve the execution time and energy consumption of a parallel region up to 67% and 72%, respectively. We also show that these fine-grained improvements resulted in up to 26% of execution time and 38% of energy consumption improvement for a given OpenMP application. We finally observed that optimizing the energy consumption behavior alone across all power levels regardless of execution time behavior can lead to an additional energy consumption improvement of up to 55%. However, this improvement comes at the expense of execution time.

97 MATHEMATICS AND COMPUTING↗