Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “conservative loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

An In-Depth Look at Ground Source Heat Pumps and Other Electric Loads in Two GreenMax Homes

Building America research team Consortium for Advanced Residential Buildings (CARB) partnered with WPPI Energy to answer key research questions on in-field performance of ground-source heat pumps and lighting, appliance, and miscellaneous loads (LAMELs) through extensive field monitoring at two WPPI GreenMax demonstration homes in Wisconsin. These two test home evaluations provided valuable data on the true in-field performance of various building mechanical systems and LAMELs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Hydronic Rooftop Unit-HyPak-MA

The majority of U.S. commercial floor space is cooled by rooftop HVAC units (RTUs). RTU popularity derives chiefly from their low initial cost and relative ease of service access without disturbing building occupants. Unfortunately, current RTUs are inherently inefficient due to a combination of characteristics that unnecessarily increase cooling loads and energy use. 36% percent of annual U.S. energy, and two-thirds of electricity, is consumed in and by buildings. Commercial buildings consume approximately 4.2 quads of energy each year at a cost of $230 billion per year, with HVAC equipment consuming 1.2 quads of electricity. More than half of all U.S. commercial floor space is cooled by packaged HVAC units, most of which are rooftop units (RTUs). Inefficient RTUs create an estimated 3.5% of U.S. CO{sub 2} emissions, thus contributing significantly to global warming5. Also, RTUs often fail to maintain adequate ventilation air and air filtration, reducing indoor air quality. This is the second HyPak project to be supported by DOE through NETL. The prior project, referred to as HyPak-1 in this report, had two rounds of prototype fabrication and testing as well as computer modeling and market research. The HyPak-1 prototypes demonstrated the high performance capabilities of the HyPak concept, but made it clear that further development was required to reduce heat exchanger cost and improve system reliability before HyPak commercialization can commence. The HyPak-1 prototypes were limited to about 25% ventilation air fraction, limiting performance and marketability. The current project is intended to develop a 'mixed-air' product that is capable of full 0-100% modulation in ventilation air fraction, hence it was referred to as HyPak-MA in the proposal. (For simplicity, the -MA has been dropped when referencing the current project.) The objective of the HyPak Project is to design, develop and test a hydronic RTU that provides a quantum improvement over conventional RTU performance. Our proposal targeted 60% and 50% reduction in electrical energy use by the HyPak RTU for dry and humid climates, respectively, when compared with a conventional unit, and reduction in peak energy consumption of 50% and 33% respectively. In addition to performance targets, our goal is to develop a production-ready design with durability, reliability and maintainability similar to air-cooled packaged equipment, and that can be commercialized immediately following the conclusion of this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterizing peak electricity demand for U.S. households: an assessment of end-use loads and demand factors

Understanding household peak electricity demand is critical to evaluate the technical need for electrical infrastructure upgrades. This study characterizes peak loads for existing and new equipment using metered data from a convenience sample of 11,940 U.S. dwellings from four sources, including 911 from two sources with end-use metering. After standardized data cleaning and labeling, we derived descriptive statistics for key metrics, such as maximum demand and demand factors, and developed predictive models relating 60- to 15-min demand for the National Electrical Code (NEC). Mean 15-min maximum demand was 9.7 kW (median 9.0 kW; IQR 7.0–11.5 kW, 95% CI 9.6–9.8 kW), indicating spare capacity in 98% of homes with hypothetical 100 A panels. Maximum demand increased with floor area and number of high-demand loads. Dwelling maximum demand was driven by higher-power, longer-duration heating appliances and vehicle charging, while most user-operated appliances contributed little. Demand factors are used to account for how most devices contribute less than their rated power to maximum demand. Existing load mean demand factors (28%; median 10%; IQR 0–58%; CI 28–29%) were higher than those for new loads (21%; median 7%; IQR 0–35%; CI 20–21%), because new loads changed the timing and magnitude of maximum demand. New high-demand loads had higher than average demand factors (40–60%). Whole dwelling demand factors support the NEC's 40% assumption, but they challenge its conservative 100% treatment of new HVAC. We propose a data-driven 50% demand factor for new equipment, which would align with metered data, improve affordability, and modernize electrical codes.

Appliances↗

Force-free motion of a cold plasma during the current quench

Cold disruptive plasma tends to move during the current quench. Its motion is essentially force-free since the current quench timescale is resistive rather than Alfvénic. In contrast to the hot vertical displacement events, the frozen-in condition is violated in the cold plasma case, and the plasma motion is not governed by magnetic flux conservation but rather by its dissipation. In this paper, we present a numerical model of the cold plasma dynamics. This model predicts electromagnetic loads on the vacuum vessel, the plasma flow and density evolution, and the plasma centroid evolution. Our calculations include poloidal wall currents. Finally, we demonstrate their significant contribution to the force acting on the vacuum vessel.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Visualization of a radical B 12 enzyme with its G-protein chaperone

G-protein metallochaperones ensure fidelity during cofactor assembly for a variety of metalloproteins, including adenosylcobalamin (AdoCbl)-dependent methylmalonyl-CoA mutase and hydrogenase, and thus have both medical and biofuel development applications. In this paper, we present crystal structures of IcmF, a natural fusion protein of AdoCbl-dependent isobutyryl-CoA mutase and its corresponding G-protein chaperone, which reveal the molecular architecture of a G-protein metallochaperone in complex with its target protein. These structures show that conserved G-protein elements become ordered upon target protein association, creating the molecular pathways that both sense and report on the cofactor loading state. Structures determined of both apo- and holo-forms of IcmF depict both open and closed enzyme states, in which the cofactor-binding domain is alternatively positioned for cofactor loading and for catalysis. Finally and notably, the G protein moves as a unit with the cofactor-binding domain, providing a visualization of how a chaperone assists in the sequestering of a precious cofactor inside an enzyme active site.

59 BASIC BIOLOGICAL SCIENCES↗

Comprehensive Margin Assessment of the ASME Section III, Division 5, Class A Primary Load Design Rules

This report provides a comprehensive margin assessment of the ASME Section III, Division 5, Subsection HB, Subpart B rules for the design of high temperature reactor components against load controlled stress limits. These rules, often called the Code primary load design rules, provide protection against creep rupture and plastic collapse under steady conditions. The method adopted here is to compare the deterministic ASME design life, according to the primary load design rules, against the expected, statistical service life of the component, considering creep rupture as the relevant failure mode. The report provides the design margin of the ASME rules in terms of the probability of premature failure -- the probability that the component fails in service before reaching the ASME design life. To complete this assessment, the report describes the development of a statistical creep life assessment procedure accounting for variations in the component loading, material creep rate, and the material rupture time. This includes a novel method for correlating creep rupture data using a Gaussian process accounting for heat-to-heat variation in the Larson-Miller time-temperature parameter. The report applies the complete margin assessment process to quantify the design margin inherent in the ASME primary load design rules as a function of temperature for relevant component geometries and materials. The overall conclusion is that the ASME rules are conservative, providing designs with very small probability of premature failure, but some optimization of the Code design rules is possible to provide a more uniform design margin.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Burnup Credit Approach for Margin Estimation of Loaded Boiling Water Reactor Canisters in UNF-ST&DARDS

This paper discusses the modeling approach applied in the Used Nuclear Fuel Storage, Transportation, & Disposal Analysis Resource and Data System (UNF-ST&DARDS) to take credit for the reduced reactivity associated with the burnup of boiling water reactor (BWR) fuel for canister-specific as loaded criticality analysis. Burnup credit is routinely used for the analysis of pressurized water reactor (PWR) spent nuclear fuel (SNF) storage (wet), transportation, and disposal. The fresh fuel assumption has historically been applied to BWR SNF criticality analyses for dry storage and transportation, and the peak reactivity method of burnup credit has been applied to pool storage. The fresh fuel assumption ignores the credit for gadolinium burnable absorbers in BWR fuel, as well as the burnup of the fuel, and is therefore conservative. This work employs the framework traditionally used for PWR burnup credit analyses and applies available data and recently published regulatory guidance to justify a new approach to model the as-loaded burnup and enrichment of SNF assemblies in currently loaded dry casks. The following features of this criticality analysis approach are presented in this paper: (1) selection of axial burnup profiles for BWR fuel from publicly available sources using methods derived from recently published research, (2) justification of the selected axial burnup profiles as relevant to all types of BWR fuel, (3) justification for modeling the fuel assemblies with a uniform axial and radial enrichment, and (4) justification for modeling the axial void profile and control blade insertion during depletion. This analysis approach was used to evaluate 153 already-loaded BWR casks at 8 sites as a function of time in UNF ST&DARDS. Finally, the results of the as-loaded criticality safety margin assessments are presented. The results show the k eff calculated for storage and transportation cases range from 0.71 to 0.83, and the eigenvalues calculated for the disposal cases range from 0.85 to 1.03, though the highest cases are dominated by very limiting hypothetical damaged fuel assumptions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A burnup credit approach for margin estimation of loaded boiling water reactor canisters in UNF-ST-DARDS

This paper discusses the modeling approach applied in the Used Nuclear Fuel Storage, Transportation, and Disposal Analysis Resource and Data System (UNF-ST-DARDS) to take credit for the reduced reactivity associated with the burnup of boiling water reactor (BWR) fuel for canister-specific as-loaded criticality analysis. Burnup credit is routinely used for the analysis of pressurized water reactor (PWR) spent nuclear fuel (SNF) storage (wet), transportation, and disposal. The fresh fuel assumption has historically been applied to BWR SNF criticality analyses for dry storage and transportation, and the peak reactivity method of burnup credit has been applied to pool storage. The fresh fuel assumption ignores the credit for gadolinium burnable absorbers in BWR fuel, as well as the burnup of the fuel, and is therefore conservative. This work employs the framework traditionally used for PWR burnup credit analyses and applies available data and recently published regulatory guidance to justify a new approach to model the as-loaded burnup and enrichment of SNF assemblies in currently loaded dry casks. The following features of this criticality analysis approach are presented in this paper: (1- selection of axial burnup profiles for BWR fuel from publicly available sources using methods derived from recently published research, (2- justification of the selected axial burnup profiles as relevant to all types of BWR fuel, (3- justification for modeling the fuel assemblies with a uniform axial and radial enrichment, and (4- justification for modeling the axial void profile and control blade insertion during depletion. This analysis approach was used to evaluate 153 already-loaded BWR casks at 8 sites as a function of time in UNF-ST-DARDS. Finally, the results of the as-loaded criticality safety margin assessments are presented. The results show the k{sub eff} calculated for storage and transportation cases range from 0.71 to 0.83, and the eigenvalues calculated for the disposal cases range from 0.85 to 1.03, though the highest cases are dominated by very limiting hypothetical damaged fuel assumptions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Finned-tube-integrated modular thermal storage systems for HVAC load modulation in buildings

While there is considerable focus on latent-based thermal energy storage (TES) systems, the low thermal conductivity of phase change materials (PCMs) remains a critical concern. Many approaches to enhance PCM conductivity either require complicated synthesis processes or are cost prohibitive. In this study, we investigate finned-tube modular TES systems, which are simple in design, easy to manufacture, and cost-effective due to their standard materials and components. The study includes detailed modeling and experimentation of two devices containing similar amounts of PCM but different fin spacings. The study reveals that having more fins does not necessarily increase the TES thermal performance because the reduction in the PCM volume fraction can reduce the TES volumetric and specific energy densities. We find that larger fin spacings provide a higher specific energy for lower C rates (<1C), while smaller fin spacings provide a higher specific energy for higher C rates (>1C).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Contrasting the capabilities of building energy performance simulation programs

For the past 50 years, a wide variety of building energy simulation programs have been developed, enhanced and are in use throughout the building energy community. This paper is an overview of a report, which provides up-to-date comparison of the features and capabilities of twenty major building energy simulation programs. The comparison is based on information provided by the program developers in the following categories: general modeling features; zone loads; building envelope and daylighting and solar; infiltration, ventilation and multizone airflow; renewable energy systems; electrical systems and equipment; HVAC systems; HVAC equipment; environmental emissions; economic evaluation; climate data availability, results reporting; validation; and user interface, links to other programs, and availability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Study of Swimming Pool Heaters

The objective of this report is to perform a controlled laboratory study on the efficiency and emissions of swimming pool heaters based on a limited field investigation into the range of expected variations in operational parameters. Swimming pool heater sales trends have indicated a significant decline in the number of conventional natural gas-fired swimming pool heaters (NGPH). On Long Island the decline has been quite sharp, on the order of 50%, in new installations since 2001. The major portion of the decline has been offset by a significant increase in the sales of electric powered heat pump pool heaters (HPPH) that have been gaining market favor. National Grid contracted with Brookhaven National Laboratory (BNL) to measure performance factors in order to compare the relative energy, environmental and economic consequences of using one technology versus the other. A field study was deemed inappropriate because of the wide range of differences in actual load variations (pool size), geographic orientations, ground plantings and shading variations, number of hours of use, seasonal use variations, occupancy patterns, hour of the day use patterns, temperature selection, etc. A decision was made to perform a controlled laboratory study based on a limited field investigation into the range of expected operational variations in parameters. Critical to this are the frequency of use, temperature selection, and sizing of the heater to the associated pool heating loads. This would be accomplished by installing a limited amount of relatively simple compact field data acquisition units on selected pool installations. This data included gas usage when available and alternately heater power or gas consumption rates were inferred from the manufacturer's specifications when direct metering was not available in the field. Figure 1 illustrates a typical pool heater installation layout.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Office Buildings: Assessing and Reducing Plug and Process Loads in Office Buildings (Fact Sheet)

Plug and process loads (PPLs) in commercial buildings account for almost 5% of U.S. primary energy consumption. Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. PPLs are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the occupants. They use an increasingly largefraction of the building energy use pie because the number and variety of electrical devices have increased along with building system efficiency. Reducing PPLs is difficult because energy efficiency opportunities and the equipment needed to address PPL energy use in office spaces are poorly understood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Plug Load Capacities and Power Requirements in Commercial Buildings: Preprint

Plug and process load power requirements are frequently overestimated because designers often use estimates based on 'nameplate' data, or design assumptions are high because information is not available. This generally results in oversized heating, ventilation, and air-conditioning systems; increased initial construction costs; and increased energy use caused by inefficiencies at low, part-load operation. Rightsizing of chillers in two buildings reduced whole-building energy use by 3%-4%. If an integrated design approach could enable 3% whole-building energy savings in all U.S. office buildings stock, it could save 34 TBtu of site energy per year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhanced Ethanol Production from De-Ashed Paper Sludge by Simultaneous Saccharification and Fermentation and Simultaneous Saccharification and Co-Fermentation

A previous study demonstrated that paper sludges with high ash contents can be converted to ethanol by simultaneous saccharification and fermentation (SSF) or simultaneous saccharification and co-fermentation (SSCF). High ash content in the sludge, however, limited solid loading in the bioreactor, causing low product concentration. To overcome this problem, sludges were de-ashed before SSF and SSCF. Low ash content in sludges also increased the ethanol yield to the extent that the enzyme dosage required to achieve 70% yield in the fermentation process was reduced by 30%. High solid loading in SSF and SSCF decreased the ethanol yield. High agitation and de-ashing of the sludges were able to restore the part of the yield loss caused by high solid loading. Substitution of the laboratory fermentation medium (peptone and yeast extract) with corn steep liquor did not bring about any adverse effects in the fermentation. Fed-batch operation of the SSCF and SSF using low-ash content sludges was effective in raising the ethanol concentration, achieving 47.8 g/L and 60.0 g/L, respectively.

09 BIOMASS FUELS↗

Evaluating Thermostats' Deadbands Using HVAC Hardware-In-the-Loop Experiment for Advanced Control Strategies

Smart thermostats have gained significant popularity due to their potential for optimizing energy consumption and enhanced user control while ensuring occupants' comfort. The deadband, also referred to as temperature differential, is defined as the temperature difference between the desired setpoint and upper threshold or lower threshold for the HVAC equipment to turn on. It is a key factor influencing energy efficiency and user satisfaction. This paper presents a comparative analysis of the deadbands of five different smart thermostats, tested with a heat pump, aiming to identify variations in their deadband settings and implications for energy management. The experimental study was conducted using a HVAC hardware-in-theloop (HIL) system that integrates smart thermostats with physical HVAC equipment in a simulated house environment. The study explores the trade-offs between energy efficiency and occupant comfort and highlights how different thermostats participating in demand response event cycle differently based on their deadband settings. The findings offer valuable insights into how selecting the right thermostat or configuring smart thermostat with appropriate deadband settings can be leveraged to enhance demand response capabilities, shift loads effectively and improve operational flexibility in HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating Thermostats' Deadbands Using HVAC Hardware-In-the-Loop Experiment for Advanced Control Strategies: Preprint

Smart thermostats have gained significant popularity due to their potential for optimizing energy consumption and enhanced user control while ensuring occupants' comfort. The deadband, also referred to as temperature differential, is defined as the temperature difference between the desired setpoint and upper threshold or lower threshold for the HVAC equipment to turn on. It is a key factor influencing energy efficiency and user satisfaction. This paper presents a comparative analysis of the deadbands of five different smart thermostats, tested with a heat pump, aiming to identify variations in their deadband settings and implications for energy management. The experimental study was conducted using a HVAC hardware-in-theloop (HIL) system that integrates smart thermostats with physical HVAC equipment in a simulated house environment. The study explores the trade-offs between energy efficiency and occupant comfort and highlights how different thermostats participating in demand response event cycle differently based on their deadband settings. The findings offer valuable insights into how selecting the right thermostat or configuring smart thermostat with appropriate deadband settings can be leveraged to enhance demand response capabilities, shift loads effectively and improve operational flexibility in HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CFD Applications in Support of the Space Shuttle Risk Assessment

The paper describes a numerical study of a potential accident scenario of the space shuttle, operating at the same flight conditions as flight 51L, the Challenger accident. The interest in performing this simulation is derived by evidence that indicates that the event itself did not exert large enough blast loading on the shuttle to break it apart. Rather, the quasi-steady aerodynamic loading on the damaged, unbalance vehicle caused the break-up. Despite the enormous explosive potential of the shuttle total fuel load (both liquid and solid), the post accident explosives working group estimated the maximum energy involvement to be equivalent to about five hundreds of pounds of TNT. This understanding motivated the simulation described here. To err on the conservative side, we modeled the event as an explosion, and used the maximum energy estimate. We modeled the transient detonation of a 500 lbs spherical charge of TNT, placed at the main engine, and the resulting blast wave propagation about the complete stack. Tracking of peak pressures and impulses at hundreds of locations on the vehicle surface indicate that the blast load was insufficient to break the vehicle, hence demonstrating likely crew survivability through such an event.

Baum, Joseph D.↗

Application of Sleeper Cab Thermal Management Technologies to Reduce Idle Climate Control Loads in Long-Haul Trucks

Each intercity long-haul truck in the U.S. idles approximately 1,800 hrs per year, primarily for sleeper cab hotel loads. Including workday idling, over 2 billion gallons of fuel are used annually for truck idling. NREL's CoolCab project works closely with industry to design efficient thermal management systems for long-haul trucks that keep the cab comfortable with minimized engine idling andfuel use. The impact of thermal load reduction technologies on idle reduction systems were characterized by conducting thermal soak tests, overall heat transfer tests, and 10-hour rest period A/C tests. Technologies evaluated include advanced insulation packages, a solar reflective film applied to the vehicle's opaque exterior surfaces, a truck featuring both film and insulation, and abattery-powered A/C system. Opportunities were identified to reduce heating and cooling loads for long-haul truck idling by 36% and 34%, respectively, which yielded a 23% reduction in battery pack capacity of the idle-reduction system. Data were also collected for development and validation of a CoolCalc HVAC truck cab model. CoolCalc is an easy-to-use, simplified, physics-based HVAC loadestimation tool that requires no meshing, has flexible geometry, excludes unnecessary detail, and is less time-intensive than more detailed computer-aided engineering modeling approaches.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗