Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “conditional thermal state”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Topological Interface between Pfaffian and Anti-Pfaffian Order in $\textit{ν}$ = 5/2 Quantum Hall Effect

A recent thermal Hall experiment triggered renewed interest in the problem of $\textit{ν}$ = 5/2 quantum Hall effect, which motivated novel interpretations based on the formation of mesoscopic puddles made of Pfaffian and anti-Pfaffian topological orders. Here, we study an interface between the Pfaffian and anti-Pfaffian states, which may play crucial roles in thermal transport, by means of state-of-the-art, density-matrix renormalization group simulations. We demonstrate that an intrinsic electric dipole moment emerges at the interface, similar to the “$\textit{p–n}$” junction sandwiched between $\textit{N}$-type and $\textit{P}$-type semiconductor. Importantly, in this work we elucidate the topological origin of this dipole moment, whose formation is to counterbalance the mismatch of guiding-center Hall viscosity of bulk Pfaffian and anti-Pfaffian states. In addition, these results imply that the formation of a dipole moment could be helpful to stabilize the puddles made of Pfaffian and anti-Pfaffian states in experimental conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deep potential molecular dynamics simulations of ion-enhanced etching of silicon by atomic chlorine

The continued development of plasma-assisted processing techniques requires a fundamental understanding of plasma-surface interactions. Molecular dynamics (MD) simulations have been employed to complement experimental studies and better understand the properties of such systems. Recently, machine learning (ML) methods have enabled the development of ab initio-based interatomic potentials, which can be generalized to complex combinations of multiple atom types. In this work, we use ML potentials developed using the Deep Potential Molecular Dynamics (DeepMD) framework to provide a model of ion-enhanced etching of Si by Cl atoms. We demonstrate the importance of proper selection of the training data set to the accuracy of the DeepMD model and compare our results to MD results using empirical potentials, as well as to experimental measurements. Exposure of undoped Si at 300 K to thermal Cl atoms yields a steady-state Cl coverage of 1.25 monolayers, which is slightly lower than the value obtained in previous experimental studies. Predictions of Si etch yields by simultaneous Cl atom and Ar + ion impacts as a function of ion energy, neutral to ion flux ratio, and angle of incidence of the ions are in reasonably good agreement with classical MD results and experimental measurements. Finally, etch yields and SiCl x mixed layer thicknesses during simultaneous bombardment of the Si(100) surface by Cl atoms and Cl + ions are in good agreement with experimental data. In conclusion, the present work is a necessary condition for the extension of the DeepMD procedure to more complex systems of interest in plasma-surface interactions.

Artificial neural networks↗

Heat Transfer Experiments of a 1st Stage Blade Cascade for Supercritical CO2 Oxy-Combustion Turbine Application

The results of internally cooled 1st stage blade (S1B) cascade testing in a supercritical CO2 environment is presented. The turbine blade design has been previously established for the end application of an oxy-combustion turbine operating in the Allam-Fetvedt cycle with turbine inlet conditions of 305 bar and 1150°C. The internally cooled blade features leading edge (LE) region impingement cooling, mid-section ribbed serpentine passages, and a pin-finned trailing edge (TE) region before cooling ejection holes. The geometry for the tested blade cascade has a cooled central blade with un-cooled blades on either side to match flowpath areas of the actual turbine. The flowpath reuses internal components previously employed for mid-section region ribbed serpentine passage experiments that established Nusselt number enhancement ratios over a range of Reynolds numbers from 100,000-400,000. New components include flow conditioning plates upstream and downstream of the blade cascade to adequately represent the flow field and blade external heat transfer coefficient profiles for the actual turbine. The cooled central blade utilizes uniform crystal temperature sensors (UCTS) with six sensors each on the blade pressure and suction surfaces distributed radially and from LE to TE. The post-processed UCTS quantified the maximum wall temperature seen at each installed sensor location. The test procedure consisted of establishing supercritical CO2 cooling flow temperature and flow rate and maintaining it throughout the test. The flow rate aims to match that for the actual in-service turbine blade design and is maintained through an orifice restriction to keep the pressure differential between internal cooling flow and external hot flow nearly constant. For the sCO2 flow path external to the blade, temperatures were ramped throughout the test via control of the test loop’s natural gas burner heater. The maximum temperature seen was 468°C and held constant for a duration of 10 minutes at which the blade metal temperature was predicted to be at its maximum before ramping down. For the turbine blade design for service inlet conditions, external flow path computational fluid dynamics (CFD) results and an internal cooling 1-D thermal and hydraulic flow network model using experimentally validated correlations served as thermal finite element (FE) boundary conditions to predict blade metal temperatures. These predicted temperatures were subsequently utilized in a structural FE model to predict blade life ratings dictated by Haynes 282 creep strength data, having a strong dependence on temperature. The boundary conditions experienced during testing are used in the same workflow and compared to the experimental results, with the goal of validating the analysis methodology and providing insight on the uncertainty in local metal temperature predictions.

20 FOSSIL-FUELED POWER PLANTS↗

Boundary-induced classical generalized Gibbs ensemble with angular momentum

We investigate how confinement geometry leads to the emergence of a Generalized Gibbs Ensemble (GGE) in classical systems. Unlike the standard Gibbs ensemble, the GGE includes additional conserved quantities, such as angular momentum, that arise from boundary-induced symmetries. Using analytical arguments based on the maximum entropy principle, we show that circular boundaries preserve angular momentum and drive the system toward a chiral, non-ergodic GGE that violates time-reversal symmetry. This ensemble differs fundamentally from the Gibbs case, producing near-boundary condensation and revealing how geometry alone can alter thermal equilibration. To quantify these effects, we introduce an order parameter measuring deviations from Gibbs behavior and demonstrate that conventional Monte Carlo methods must incorporate angular momentum conservation under such conditions. Our study highlights how geometric constraints shape non-equilibrium statistical ensembles and lead to subtle departures from the Bohr-van Leeuwen theorem. These predictions are validated through detailed simulations of confined classical hard-disk gases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Heating performance of an air source heat pump with a portable thermoelectric subcooler

This study investigates the heating performance of an integrated air-source heat pump (ASHP) with a thermoelectric subcooler (TES) module, revealing significant performance enhancements, particularly in colder temperatures. Results show that adding the portable TES boosts the ASHP's heating capacity, making it feasible for residential applications. The coefficient of performance (COP) for the TE system, which is influenced by condensing temperatures and ambient conditions, ranges from 1.51 to 2.07. If condensing temperatures are consistently maintained above 35 °C, a TE COP of approximately 2.07 is achievable, supporting system downsizing and reducing supplemental heating. When coupled with an oversized indoor coil, the TES-ASHP system delivers comparable heating to a baseline unit while achieving a 10 % higher COP. Capacity increases by 8.7 %–24 % with TES in colder conditions, though COP declines by 9 %–18 %, diminishing as temperatures drop. Compared to systems with supplemental heating, this setup achieves a COP 10 %–17 % higher. Future work will involve extended field testing in various climates, exploration of advanced materials for thermal efficiency, and assessment of alternative refrigerants to improve performance and sustainability. This integrated ASHP-TES system holds promise for increased efficiency and reduced environmental impact in cold climates.

Air source heat pump↗

High-resolution neutron time-of-flight measurements for light water at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory

Series of light water inelastic neutron scattering experiments have been made at the Oak Ridge National Laboratory (ORNL), Spallation Neutron Source (SNS) covering temperatures ranging from 295 K to 600 K and pressures of 1 bar and 150 bar. The temperatures and pressures ranges correspond to that of pressurized light water reactors. The inelastic scattering measurements will help the development of light water thermal scattering kernels, also known as S (α,β) thermal scattering law (TSL), in a consistent fashion given the amount and the quality of the measured data. Light water thermal scattering evaluations available in existing nuclear data libraries have certain limitations and pitfalls. This paper introduces the state of the art of the light water thermal scattering cross-section data not only for room temperature but as well as for reactor operating temperatures, i.e. 550 - 600 K. During the past few years there has been a renewed interest in re-investigating the existing TSL models and utilize the recent experimental data or perform molecular dynamics simulations. It should be pointed out that no single TSL evaluation is based entirely on experimental data and one has to rely on TSL models or a combination of both. New TOF measurement of light water at the SNS, with a detailed description of the experimental setup, measurement conditions, and the associated foreseen results is presented in this paper. The analysis of the experimental data would help in validating the existing approach based on old experimental data or based on molecular dynamic simulations using classical water models, knowledge of which is very important to generate TSL libraries at reactor operating conditions.

Leal, Luiz C.↗

Research Requirements to Move the Bar forward Using Aqueous Formate Salts as H 2 Carriers for Energy Storage Applications

In this perspective on hydrogen carriers, we focus on the needs for the development of robust active catalysts for the release of H 2 from aqueous formate solutions, which are non-flammable, non-toxic, thermally stable, and readily available at large scales at reasonable cost. Formate salts can be stockpiled in the solid state or dissolved in water for long term storage and transport using existing infrastructure. Furthermore, formate salts are readily regenerated at moderate pressures using the same catalyst as for the H 2 release. There have been several studies focused on increasing the activity of catalysts to release H 2 at moderate temperatures, i.e., < 80 °C, below the operating temperature of a proton exchange membrane (PEM) fuel cell. One significant challenge to enable the use of aqueous formate salts as hydrogen carriers is the deactivation of the catalyst under operating conditions. In this work we provide a review of the most efficient heterogeneous catalysts that have been described in the literature, their proposed modes of deactivation, and the strategies reported to reactivate them. We discuss potential pathways that may lead to deactivation and strategies to mitigate it in a variety of H 2 carrier applications. We also provide an example of a potential use case employing formate salts solutions using a fixed bed reactor for seasonal storage of energy for a microgrid application.

25 ENERGY STORAGE↗

Modeling and Simulation of Fuel Dispersal During the Loss-of-Coolant Accident

This document is the compilation of the milestone portion to a larger end of project NEUP report. The executive summary of the modeling portion is provided below: In the event of cladding rupture during a postulated LOCA in a pressurized water reactor, fuel particles, along with fission gases, can be expelled into the reactor core from the fractured fuel rod, a phenomenon referred to as fuel dispersal. The initial stage of fuel dispersal is strongly influenced by the high-pressure ejection of fuel fragments, the size and geometry of the ruptured cladding, and the depressurization history of the fuel rod during the postulated LOCA transient. Depending on the location of the burst orifice relative to the quench front, the dispersal event represents an intricate three-phase flow and heat transfer phenomenon, where high-temperature fuel particles carried by the fission gases interact with the coolant within the narrow subchannels of the fuel assemblies, inducing localized phase change. Given the unique multiphysics nature of this phenomena, the current study develops a dedicated computational framework to predict the mass distribution and cooling of dispersing fuel particles, facilitating post-accident assessment and management of the fuel assemblies. Considering the scale of nuclear reactor applications, a continuum three-fluid model is proposed for simulating the transport of solids within the reactor core. With high-temperature fuel fragments within the liquid media, nucleation sites inducing phase changes are dispersed within the flow domain. Coupled with the fact that the transient dispersal event occurs on different time scales than other three-phase flow applications, this study derives a time-averaged three-fluid flow model without losing generality. The assumptions regarding the continuum treatment of the solid phase and the modeling of fuel dispersal behavior are incorporated to simplify the governing equations and derive applicable closure relations. The computational validation of the model was conducted using adiabatic experimental results obtained from ongoing research at Oregon State University, focusing on characterizing fuel dispersal behavior during simulated LOCA conditions. Settlement characteristics of the solids, quantified by the probability distribution of equivalent particles, closely matched the probability density functions reported in experimental studies. The transport of fuel particles within a scaled 5 × 5 lattice of a pressurized-water reactor rod bundle geometry was modeled through a two-fluid Eulerian framework. The required boundary conditions were evaluated from the fuel performance code BISON in a postulated large-break LOCA scenario. The modeling framework considered solid fuel particles as granular matter, interacting with the gaseous dry steam phase and fission gases through the governing interfacial momentum exchange between the participating fluids. The simulation results provided the volume fraction of the solids obtained at the bottom surface of the enclosing tank geometry. Postulated LOCA leading to fuel dispersal phenomena involves the strong coupling between fuel thermomechanics, cladding deformation, thermal-hydraulics, and fuel particle transport. Incorporation of such a strong coupling in numerical simulation is performed by coupling the multiphysics solvers. In the case of fuel dispersal, a strong coupled simulation can be performed by coupling the BISON code for fuel performance, the TRACE code for system-level thermal hydraulics, and fuel particle transport in Multiphysics Object-Oriented Simulation Environment (MOOSE). For such intricate infrastructure, the MOOSE Framework eases the data transfer between codes. The recent version of MOOSE has incorporated the Navier-Stokes module for the fluid flow. An exploratory exercise was done to gain familiarity with finite volume capabilities in the MOOSE framework to incorporate the Spalart-Allmaras (SA) turbulence model. New finite-volume and auxiliary kernels were introduced to assemble the SA transport equation, compute turbulent viscosity, and evaluate wall distance and diagnostic turbulence terms, fully integrated with existing Navier-Stokes modules. A turbulent lid-driven cavity at a Reynolds number of approximately 10,000 is used for verification. MOOSE shows the robust solver convergence and produces the turbulent features. But it underpredicts the velocity profile and turbulent quantities, emphasizing the need to develop improved SA near-wall treatments (e.g., low-Re corrections or wall functions) as a key direction for future work.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

WBG-Enabled Current-Source Inverters for Integrated PM Motor Drives

This project takes advantage of the special capabilities of wide-bandgap (WBG) power semiconductor devices to develop innovative power electronics in the form of new current-source inverters (CSIs) that offer promising advantages over the dominant voltage-source inverter (VSI) topology. These CSIs, in turn, are extremely well-suited for integration into the housings of permanent magnet synchronous machines (PMSMs) to form integrated motor drives (IMDs). These new IMDs offer great promise for achieving major energy savings in a wide variety of applications that benefit from adjustable-speed control, including air conditioners, laundry appliances, industrial pumps/compressors, electric vehicles, and aerospace drives. WBG devices play a critical enabling role in these new IMDs because of their transformative features including much higher switching frequencies, lower losses, and compatibility with high operating temperatures. When incorporated into new CSI-based IMDs with PM machines, these WBG switches open the door to achieving major increases in power density, drive system efficiency, and fault tolerance, as well as substantial reductions in electromagnetic interference (EMI), manufacturing cost, and temperature-induced failures. The higher operating temperature capability of WBG devices compared to conventional silicon power devices is very appealing in IMD applications because the power electronics is mounted in close proximity to the motors which typically operate at temperatures well above the maximum limits of today’s silicon-based power electronics. This project has succeeded in designing, building, and testing multiple prototype versions of this CSI-IMD that have overcome many technical challenges in order to demonstrate the impressive performance improvements that can be achieved by the WBG-enabled CSI-IMD. The preliminary demo and bench-top versions of the current-source inverter developed during the first two years of the project were critical to laying the technical foundations for the 3 kW prototype CSI-IMD unit that was successfully built and tested during the third year. This prototype CSI-IMD unit was designed to fit within the housing envelope of the original permanent magnet (PM) synchronous machine in order to meet the demanding power density requirements that were set at the beginning of the project. All of the remaining performance objectives set for the prototype CSI-IMD unit including efficiency and electromagnetic interference (EMI) were also met. The last 18 months of the project were devoted to developing further enhancements of the WBG-enabled CSI-IMD technology that better prepare it for commercial production. More specifically, an upgraded version of the prototype CSI-IMD unit was developed that moved the power electronics into the same machine housing chamber as the motor, substantially raising the thermal demands on the power electronics. Tests with five different combinations of motor enclosure types and air cooling configurations were evaluated. Importantly, this work confirmed that the power electronics can deliver its full rated power and still operate well within its maximum temperature limits even for worst-case conditions when the housing is “totally-enclosed” without any openings for air to enter or exit the enclosure, and no blower/fan is provided to blow air over the outside surface of the enclosure. Reaching the full performance and energy-savings potential of this disruptive CSI-IMD motor drive technology is highly consistent with ARPA-E’s stated mission to “enhance the economic and energy security of the United States” while also supporting its commitment to “ensure that the U.S. maintains a technological lead in developing and deploying advanced energy technologies”. Follow-on projects are under way to explore the scalability of WBG-enabled CSI-IMD technology to 100 kW (peak) electric vehicle traction drives and fault-tolerant modular motor drives for future electrified aircraft propulsion applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Explaining an unusual electromigration behavior—A comprehensive experimental and theoretical analysis using finite element method

In metallic interconnects, it is generally assumed that electromigration (EM) failure location is independent of the applied electrical current and always occurs at the highest-current-density area. Our experiments show otherwise. We designed an Al interconnect that alters its failure location by only varying the applied current density. The failure occurs near the high for a current above 2 × 10 7 A/cm 2 , but at a location with 59% of the maximum for lower current densities. Thermoreflectance thermal imaging is employed to gather time-dependent high-resolution spatial temperature distributions of the Al interconnect during EM. More importantly, we propose a computationally inexpensive 2D finite element method that tracks EM evolution in time and matches well with the observations from different experimental conditions. A detailed analysis covering the major driving forces of EM is carried out to understand the complex physics behind EM. The atomic depletion rate contributed by each force is quantitatively studied. By examining the results from every tested experimental condition, the model reveals that the temperature gradient is the key reason causing atomic depletion near the failure location. Graphical illustrations and qualitative analysis are provided to intuitively show the key findings of our work.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Gas-Cooled High-Temperature Pebble-Bed Reactor Reference Plant Model Updates

This work presents the latest improvements to, and investigations performed with, the pebble-bed high-temperature gas-cooled reactor (PB-HTGR) reference plant models for the United States Nuclear Regulatory Commission. These models serve as the foundation for the future development of detailed design evaluation models based on license applications. The reference plant models have been developed with the Comprehensive Reactor Analysis Bundle, or BlueCRAB, which is the code suite proposed for non-light-water reactor systems safety analysis. It incorporates various simulation tools developed by the Nuclear Energy Advanced Modeling and Simulation program, including the Griffin code for reactor physics, the Pronghorn and SAM codes for core thermal fluids, the BISON code for solid conduction and fuel performance, and the SAM code for system analysis. The primary objective of the work that was performed was to assess BlueCRAB’s level of readiness for modeling a PB-HTGR. To do so, we first developed numerical models in BlueCRAB that include the key physics for this technology to ensure an adequate level of fidelity for modeling PB-HTGR core performance and for performing multiphysics simulations for equilibrium core conditions and different accident scenarios. Then we simulated transient scenarios, including depressurized and pressurized loss of forced cooling accidents, over-cooling, and control rod withdrawal events with delayed and prompt supercritical reactivity insertions. The analysis in this report includes comparisons of the 2D thermal fluid porous media models in Pronghorn and SAM, and comparisons of coupled SAM/Griffin/SAM and coupled Pronghorn/Griffin for depressurized and pressurized loss of forced cooling, over-cooling, and control rod withdrawal events. In addition, we compare 3D, 2D, and 0D/PKE neutronic models for the two control rod withdrawal scenarios with coupled Pronghorn/Griffin. The comparisons show that the BlueCRAB models lead to physically intuitive solutions for the scenarios examined. The changes in the various scalar and vector fields, such as neutron flux, power, temperature, density, pressure, and velocity, are within the expected ranges, and their distributions can be explained by the system response of the transients and the geometric and material variations. Several comparisons suggest that the porous media models in Pronghorn and SAM can lead to similar solutions, even though they are based on different methodologies. This work further highlights the need for flexible tools with various levels of fidelity to cover the breadth and depth of needs that may arise in future technical evaluations of the PB-HTGR. We believe that the BlueCRAB capabilities will be a significant asset for confirmatory analyses in order to resolve important safety questions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mechanical and Light Activation of Materials for Chemical Production

Abstract Mechanical expansion and contraction of pores within photosynthetic organisms regulate a series of processes that are necessary to manage light absorption, control gas exchange, and regulate water loss. These pores, known as stoma, allow the plant to maximize photosynthetic output depending on environmental conditions such as light intensity, humidity, and temperature by actively changing the size of the stomal opening. Despite advances in artificial photosynthetic systems, little is known about the effect of such mechanical actuation in synthetic materials where chemical reactions occur. It is reported here on a hybrid hydrogel that combines light‐activated supramolecular polymers for superoxide production with thermal mechanical actuation of a covalent polymer. Superoxide production is important in organic synthesis and environmental remediation, and is a potential precursor to hydrogen peroxide liquid fuel. It is shown that the closing of pores in the hybrid hydrogel results in a substantial decrease in photocatalysis, but cycles of swollen and contracted states enhance photocatalysis. The observations motivate the development of biomimetic photosynthetic materials that integrate large scale motion and chemical reactions.

Đorđević, Luka [Department of Chemical Sciences Un↗

Generalized quasiharmonic approximation via space group irreducible derivatives

The quasiharmonic approximation (QHA) is the simplest nontrivial approximation for interacting phonons under constant pressure, bringing the effects of anharmonicity into temperature-dependent observables. Nonetheless, the QHA is often implemented with additional approximations due to the complexity of computing phonons under arbitrary strains, and the generalized QHA, which employs constant stress boundary conditions, has not been completely developed. In this work we formulate the generalized QHA, providing a practical algorithm for computing the strain state and other observables as a function of temperature and true stress. We circumvent the complexity of computing phonons under arbitrary strains by employing irreducible second-order displacement derivatives of the Born-Oppenheimer potential and their strain dependence, which are efficiently and precisely computed using the lone irreducible derivative approach. We formulate two complementary strain parametrizations: a discretized strain grid interpolation and a Taylor series expansion in symmetrized strain. We illustrate our approach by evaluating the temperature and pressure dependence of select elastic constants and the thermal expansion in thoria (ThO 2 ) using density functional theory with three exchange-correlation functionals. The QHA results are compared to our measurements of the elastic constant tensor using time-domain Brillouin scattering and inelastic neutron scattering. Our irreducible derivative approach simplifies the implementation of the generalized QHA, which will facilitate reproducible, data-driven applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multiple injection for improving knock, gaseous and particulate matter emissions in direct injection SI engines

Advances in fuel injector technology have enabled research and development on a large variety of direct injection spark ignition (DISI) engine fueling strategies targeted to improve engine performance and reduce engine-out emissions. This study explores the effect of multiple injections on knock, engine efficiency and stability, and particulate number and gaseous emissions on a single-cylinder DISI research engine. Work to date on multiple injections in the literature is reviewed, and then two aspects of multiple injection strategies are experimentally investigated: the number of injections (up to five times in a cycle); and the timing of the injections (classified relative to the timing of intake valve opening and closing). A boosted, single-cylinder research engine equipped with a state-of-the-art piezoelectric hollow cone spray direct injector and research-grade E10 gasoline was used for the study. The results show multiple injections maintain torque and combustion stability compared with single injection and slightly increase the knock limits and indicated thermal efficiencies (maximum 0.7% absolute, 2.8% relative compared with single-injection baseline) due to improved heat release phasing, especially with an additional late injection during the intake valve closed (compression stroke) period. The gaseous pollutant emissions including nitrogen oxides and unburned hydrocarbons were reduced by 25% with multiple injections, particularly with injection during the compression stroke. In contrast, carbon monoxide emissions increased with multiple injections for all conditions. Increasing the number of injection events significantly reduced particulate number emissions (half with each additional injection), and the decrease in particulate number was not sensitive to the injection timing.

42 ENGINEERING↗

Lithium Plating Characteristics in High Areal Capacity Li-Ion Battery Electrodes

Li-ion battery degradation and safety events are often attributed to undesirable metallic lithium plating. Since their release, Li-ion battery electrodes have been made progressively thicker to provide a higher energy density. However, the propensity for plating in these thicker pairings is not well understood. Herein, we combine an experimental plating-prone condition with robust mesoscale modeling to examine electrode pairings with capacities ranging from 2.5 to 6 mAh/cm 2 and negative to positive (N/P) electrode areal capacity ratio from 0.9 to 1.8 without the need for extensive aging tests. Using both experimentation and a mesoscale model, we identify a shift from conventional high state-of-charge (SOC) type plating to high overpotential (OP) type plating as electrode thickness increases. Further, these two plating modes have distinct morphologies, identified by optical microscopy and electrochemical signatures. We demonstrate that under operating conditions where these plating modes converge, a high propensity of plating exists, revealing the importance of predicting and avoiding this overlap for a given electrode pairing. Further, we identify that thicker electrodes, beyond a capacity of 3 mAh/cm 2 or thickness >75 μm, are prone to high OP, limiting negative electrode (NE) utilization and preventing cross-sectional oversizing the NE from mitigating plating. Here, it simply contributes to added mass and volume. The experimental thermal gradient and mesoscale model either combined or independently provide techniques capable of probing performance and safety implications of mild changes to electrode design features.

25 ENERGY STORAGE↗

Thermopile Energy Harvesting for Subsurface Wellbore Sensors (Final Report)

Robust in situ power harvesting underlies all efforts to enable downhole autonomous sensors for real-time and long-term monitoring of CO 2 plume movement and permeance, wellbore health, and induced seismicity. This project evaluated the potential use of downhole thermopile arrays, known as thermoelectric generators (TEGs), as power sources to charge sensors for in situ real-time, long-term data capture and transmission. Real-time downhole monitoring will enable “Big Data” techniques and machine learning, using massive amounts of continuous data from embedded sensors, to quantify short- and long-term stability and safety of enhanced oil recovery and/or commercial-scale geologic CO 2 storage. This project evaluated possible placement of the TEGs at two different wellbore locations: on the outside of the casing; or on the production tubing. TEGs convert heat flux to electrical power, and in the borehole environment, would convert heat flux into or out of the borehole into power for downhole sensors. Such heat flux would be driven by pumping of cold or hot fluids into the borehole—for instance, injecting supercritical CO 2 —creating a thermal pulse that could power the downhole sensors. Hence, wireless power generation could be accomplished with in situ TEG energy harvesting. This final report summarizes the project’s efforts that accomplished the creation of a fully operational thermopile field unit, including selection of materials, laboratory benchtop experiments and thermal-hydrologic modeling for design and optimization of the field-scale power generation test unit. Finally, the report describes the field unit that has been built and presents results of performance and survivability testing. The performance and survivability testing evaluated the following: 1) downhole power generation in response to a thermal gradient produced by pumping a heated fluid down a borehole and through the field unit; and 2) component survivability and operation at elevated temperature and pressure conditions representative of field conditions. The performance and survivability testing show that TEG arrays are viable for generating ample energy to power downhole sensors, although it is important to note that developing or connecting to sensors was beyond the scope of this project. This project’s accomplishments thus traversed from a low Technical Readiness Level (TRL) on fundamental concepts of the application and modeling to TRL-5 via testing of the fully integrated field unit for power generation in relevant environments. A fully issued United States Patent covers the wellbore power harvesting technology and applications developed by this project.

47 OTHER INSTRUMENTATION↗

Next Generation Heat Transfer Fluids for Two-Phase Immersion Cooling of Data Centers

The purpose of this study is to evaluate the performance of next generation dielectric fluids in a Two-Phase Immersion Cooling (2PIC) system, which was designed for use in data centers. Hence, this report contains the performance evaluations of a new developmental dielectric fluid, Opteon™ 2P50, in a commercially available small-scale 2PIC system under typical and off-design range of operating conditions. Accordingly, ambient temperature and thermal loads were varied to simulate different ambient conditions. Additionally, this research report describes the development of a semi-empirical lumped model to predict the energy efficiency of the 2PIC system using Opteon™ 2P50 across a wide range of conditions. The model aims to offer a comprehensive understanding of the system’s efficiency and potential improvements. The outcomes of this study are expected to contribute to the adoption of sustainable 2PIC cooling technologies in data centers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗