Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cavity optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

High brightness diode-pumped organic solid-state laser

High-power, diffraction-limited organic solid-state laser operation has been achieved in a vertical external cavity surface-emitting organic laser (VECSOL), pumped by a low-cost compact blue laser diode. The diode-pumped VECSOLs were demonstrated with various dyes in a polymer matrix, leading to laser emissions from 540 nm to 660 nm. Optimization of both the pump pulse duration and output coupling leads to a pump slope efficiency of 11% for a DCM based VECSOLs. We report output pulse energy up to 280 nJ with 100 ns long pump pulses, leading to a peak power of 3.5 W in a circularly symmetric, diffraction-limited beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Chapter 2: Evaluating a Concentrating Solar Power Plantas an Extended-Duration Peaking Resource

We explore the ability of a concentrating solar power (CSP) plant with thermal energy storage (TES) to provide peaking capacity. We focus on future power systems, wherein net load patterns may be significantly different than they are today (e.g., due to higher renewable-energy penetrations). We examine 28 locations in the southwestern United States over an 18-year period. The hourly operation of the CSP plants are simulated to determine their potential to provide energy during an eight-hour peak-load window for each day up to 365 days per year. Our result shows that for the large majority of locations and years, CSP plants with certain configurations (i.e., in terms of solar field and TES sizes) can provide nearly 100% peak-load capacity. We examine also the amount of supplemental energy (e.g.,by using natural gas as a supplemental thermal-energy source) that would be required to ensure that a CSP plant could serve the eight highest-load hours of every day of the year. We find that in most cases, a CSP plant supplemented with natural gas would require less than 5% of the fuel that is used by a natural-gas fired power plant providing the same level of reliable capacity. A series of sensitivity analyses show that these results are robust to the number of peak-load hours and days that are considered and the configuration of the CSP plant.

capacity value↗

A proton beam energy modulator for rapid proton therapy

We present the design for a rapid proton energy modulator with radiofrequency accelerator cavities, which can deliver the proton radiation dose to varied depth in human tissues much faster than traditional mechanical beam energy degraders. The proton energy modulator is designed as a multi-cell 1-m long accelerator working at 2.856 GHz. Each individual accelerator cavity is powered by a 400 kW compact klystron to provide an accelerating/decelerating gradient of 30 MV/m. The high gradient is enabled by the individual power coupling regime, which provides a high shunt impedance. Beam dynamics simulations were performed, showing that the energy modulator can provide ±30 MeV of beam energy change for a 150 MeV, 7 mm long (full length) proton bunch, and the total energy spread of 3 MeV is satisfactory to clinical needs. A prototype experiment of a single cell has been built and tested, and the low-power microwave measurement results agree very well with simulations. The energy modulator is optimized for the 150 MeV cyclotron proton beam, while this approach can work with different beam energies.

47 OTHER INSTRUMENTATION↗

SU-E-T-632: Preliminary Study On Treating Nose Skin Using Energy and Intensity Modulated Electron Beams with Monte Carlo Based Dose Calculations

Purpose: Uneven nose surfaces and air cavities underneath and the use of bolus present complexity and dose uncertainty when using a single electron energy beam to plan treatments of nose skin with a pencil beam-based planning system. This work demonstrates more accurate dose calculation and more optimal planning using energy and intensity modulated electron radiotherapy (MERT) delivered with a pMLC. Methods: An in-house developed Monte Carlo (MC)-based dose calculation/optimization planning system was employed for treatment planning. Phase space data (6, 9, 12 and 15 MeV) were used as an input source for MC dose calculations for the linac. To reduce the scatter-caused penumbra, a short SSD (61 cm) was used. Our previous work demonstrates good agreement in percentage depth dose and off-axis dose between calculations and film measurement for various field sizes. A MERT plan was generated for treating the nose skin using a patient geometry and a dose volume histogram (DVH) was obtained. The work also shows the comparison of 2D dose distributions between a clinically used conventional single electron energy plan and the MERT plan. Results: The MERT plan resulted in improved target dose coverage as compared to the conventional plan, which demonstrated a target dose deficit at the field edge. The conventional plan showed higher dose normal tissue irradiation underneath the nose skin while the MERT plan resulted in improved conformity and thus reduces normal tissue dose. Conclusion: This preliminary work illustrates that MC-based MERT planning is a promising technique in treating nose skin, not only providing more accurate dose calculation, but also offering an improved target dose coverage and conformity. In addition, this technique may eliminate the necessity of bolus, which often produces dose delivery uncertainty due to the air gaps that may exist between the bolus and skin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design of Single Spoke Resonators for Project X

Project X is based on a 3 GeV CW superconducting linac and is currently in the R&D phase awaiting CD-0 approval. The low-energy section of the Project X H-linac includes three types of super-conducting single spoke cavities operating at 325 M Hz. SSR0 (26 cavities), SSR1 (18 cavities) and SSR2 (44 cavities) have a geometrical beta of = 0.11, 0.21 and 0.4 respectively. Single spoke cavities were selected for the linac in virtue of their higher r/Q. In this paper we present the decisions and ana lyses that lead to the final designs. Electro-magnetic and mechanical finite element analyses were performed with the purpose of optimizing the electro-magnetic design, minimizing frequency shifts due to Helium bath pressure fluctuations and providing a p ressure rating for the resonators that allow their use in the cryomodules.

43 PARTICLE ACCELERATORS↗

Na9K16TI~25: A New Phase Containing Naked Icosahedral Cluster Fragments Ti99-

The phase Na{sub 9}K{sub 16}Tl{sub 25.25(2)} was synthesized by fusion of the elements in sealed Ta containers followed by quenching and annealing at 250 C. The structure established by single crystal X-ray diffraction means (P6{sub 3}/m, Z = 2, a = 19.376(3) {angstrom}, c = 11.480(2) {angstrom}) features Tl{sub 9}{sup 9-} clusters. These are well separated by cations that bridge between, faces, edges, and vertices of the clusters; sodium appears to be essential in this role. This is the third compound known to contain Tl{sub 9} clusters, but here two of nine sites are partially occupied, which can be interpreted as a 70:30 mixture of Tl{sub 9} and Tl{sub 7} units in the same cavity. This Tl{sub 9} example also displays lower symmetry (C{sub s}) but requires the same 2n skeletal electrons. EHTB electronic structure calculations indicate that the Fermi level intersects a finite densities-of-states (DOS), and only some bonds are optimized at E{sub F}, giving some insight regarding the site of Tl deficiency. Direct geometric relationships are found among Tl{sub 13}, Tl{sub 9}, Tl{sub 7} and Tl{sub 5} clusters through systematic removal of vertices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enabling high-temperature nanophotonics for energy applications

The nascent field of high-temperature nanophotonics could potentially enable many important solid-state energy conversion applications, such as thermophotovoltaic energy generation, selective solar absorption, and selective emission of light. However, special challenges arise when trying to design nanophotonic materials with precisely tailored optical properties that can operate at high-temperatures (> 1,100 K). These include proper material selection and purity to prevent melting, evaporation, or chemical reactions; severe minimization of any material interfaces to prevent thermomechanical problems such as delamination; robust performance in the presence of surface diffusion; and long-range geometric precision over large areas with severe minimization of very small feature sizes to maintain structural stability. We report an approach for high-temperature nanophotonics that surmounts all of these difficulties. It consists of an analytical and computationally guided design involving high-purity tungsten in a precisely fabricated photonic crystal slab geometry (specifically chosen to eliminate interfaces arising from layer-by-layer fabrication) optimized for high performance and robustness in the presence of roughness, fabrication errors, and surface diffusion. It offers near-ultimate short-wavelength emittance and low, ultra-broadband long-wavelength emittance, along with a sharp cutoff offering 4:1 emittance contrast over 10% wavelength separation. This is achieved via Q-matching, whereby the absorptive and radiative rates of the photonic crystal’s cavity resonances are matched. Strong angular emission selectivity is also observed, with short-wavelength emission suppressed by 50% at 75° compared to normal incidence. Finally, a precise high-temperature measurement technique is developed to confirm that emission at 1,225 K can be primarily confined to wavelengths shorter than the cutoff wavelength.

14 SOLAR ENERGY↗

SU-E-J-58: Dosimetric Verification of Metal Artifact Effects: Comparison of Dose Distributions Affected by Patient Teeth and Implants

Purpose: Implant-supported dentures seem particularly appropriate for the predicament of becoming edentulous and cancer patients are no exceptions. As the number of people having dental implants increased in different ages, critical dosimetric verification of metal artifact effects are required for the more accurate head and neck radiation therapy. The purpose of this study is to verify the theoretical analysis of the metal(streak and dark) artifact, and to evaluate dosimetric effect which cause by dental implants in CT images of patients with the patient teeth and implants inserted humanoid phantom. Methods: The phantom comprises cylinder which is shaped to simulate the anatomical structures of a human head and neck. Through applying various clinical cases, made phantom which is closely allied to human. Developed phantom can verify two classes: (i)closed mouth (ii)opened mouth. RapidArc plans of 4 cases were created in the Eclipse planning system. Total dose of 2000 cGy in 10 fractions is prescribed to the whole planning target volume (PTV) using 6MV photon beams. Acuros XB (AXB) advanced dose calculation algorithm, Analytical Anisotropic Algorithm (AAA) and progressive resolution optimizer were used in dose optimization and calculation. Results: In closed and opened mouth phantom, because dark artifacts formed extensively around the metal implants, dose variation was relatively higher than that of streak artifacts. As the PTV was delineated on the dark regions or large streak artifact regions, maximum 7.8% dose error and average 3.2% difference was observed. The averaged minimum dose to the PTV predicted by AAA was about 5.6% higher and OARs doses are also 5.2% higher compared to AXB. Conclusion: The results of this study showed that AXB dose calculation involving high-density materials is more accurate than AAA calculation, and AXB was superior to AAA in dose predictions beyond dark artifact/air cavity portion when compared against the measurements.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-TeP2-02: First Experiences and Perspectives in Using Direct Multicriteria Optimization (MCO) On Volumetric-Modulated Arc Therapy (VMAT) for Head and Neck Cancer

Purpose: To report the first experiences and perspectives in using direct multicriteria optimization (MCO) on volumetric-modulated arc therapy (VMAT) for head and neck (H&N) cancer. Methods: Ten prior patients with tumors in representative H&N regions were selected to evaluate direct MCO-VMAT in RayStation v5.0 beta. The patients were previously treated by intensity-modulated radiation therapy (IMRT) with MCO on an Elekta linear accelerator with Agility multileaf collimator. To avoid radiating eyes and shoulders, MCO-VMAT required one to three partial-arc groups, with each group consisting of single or dual arcs. All MCO-VMAT plans were approved by a radiation oncologist. The MCO-VMAT and MCO-IMRT plans were compared using V{sub 100}, D{sub 5}, homogeneity index (HI) and conformity index (CI) for planning target volume (PTV), D{sub mean} and D{sub 50} for six parallel organs and D{sub max} for five serial organs. Patient-specific quality assurance (QA) was performed using ArcCHECK for MCO-VMAT and Matrixx for MCO-IMRT with results analyzed using gamma criteria of 3%/3mm. Results: MCO-VMAT provided better V{sub 100} (+0.8%) lower D{sub 5}(− 0.3 Gy), lower HI (−0.27) and comparable CI (+0.05). MCO-VMAT decreased D{sub mean} and D{sub 50} for multiple parallel organs in seven of the ten patients. On average the reduction ranged from 2.1 (larynx) to 7.6 Gy (esophagus). For the nasal cavity and nasopharynx plans significant reduction in D{sub max} was observed for optics (up to 11 Gy) brainstem (6.4 Gy), cord (2.1 Gy) and mandible (6.7 Gy). All MCO-VMAT and -IMRT plans passed clinical QA. MCO-VMAT required slightly longer planning time due to the more complex VMAT optimization. The net beam-on time for the MCO-VMAT plans ranged from 80 to 242 seconds, up to 9 minutes shorter than MCO-IMRT. Conclusion: With similar target coverage, reduced organ dose, comparable planning time, and significantly faster treatment, MCO-VMAT is very likely to become the modality of choice in RayStation v5.0 for H&N cancer.

60 APPLIED LIFE SCIENCES↗

Chiral DOTA chelators as an improved platform for biomedical imaging and therapy applications

Despite established clinical utilisation, there is an increasing need for safer, more inert gadolinium-based contrast agents, and for chelators that react rapidly with radiometals. Here we report the syntheses of a series of chiral DOTA chelators and their corresponding metal complexes and reveal properties that transcend the parent DOTA compound. We incorporated symmetrical chiral substituents around the tetraaza ring, imparting enhanced rigidity to the DOTA cavity, enabling control over the range of stereoisomers of the lanthanide complexes. The Gd chiral DOTA complexes are shown to be orders of magnitude more inert to Gd release than [GdDOTA]¯. These compounds also exhibit very-fast water exchange rates in an optimal range for high field imaging. Radiolabeling studies with (Cu-64/Lu-177) also demonstrate faster labelling properties. These chiral DOTA chelators are alternative general platforms for the development of stable, high relaxivity contrast agents, and for radiometal complexes used for imaging and/or therapy.

60 APPLIED LIFE SCIENCES↗

ERL-Based Compact X-Ray FEL

We propose to develop an energy-recovery-linac (ERL)-based X-ray free-electron laser (XFEL). Taking advantage of the demonstrated high-efficiency energy recovery of the beam power in the ERL, the proposed concept offers the following benefits: i) recirculating the electron beam through high-gradient superconducting RF (SRF) cavities shortens the linac, ii) energy recovery in the SRF linac saves the klystron power and reduces the beam dump power, iii) the high average beam power produces a high average photon brightness. In addition, such a concept has the capability of delivering optimized high-brightness CW X-ray FEL performance at different energies with simultaneous multipole sources. In this paper, we will present the preliminary results on the study of feasibility, optics design and parameter optimization of such a device.

Lin, Fanglei↗

Deposit high purity Alumnium on Nb in support of conduction cooled SRF cavities

The project will demonstrate a potential manufacturing method that could result in a means to operate superconducting radio frequency (SRF) cavities without liquid cryogens. The technical approach sought to apply high-purity (99.999%) aluminum to cavity-grade niobium components via a new and proprietary electron-beam additive manufacturing technique contributed by PAVAC. High thermal conductivity of the aluminum could enable a cryocooler, which is a compact electrically powered refrigeration device, to extract sufficient heat for operating the cavity for a variety of applications. Trial coatings of niobium components were to be evaluated for metallurgy, mechanical bonding, and thermal and electrical conductivity using superconducting materials characterization facilities at Fermilab. The results of the characterization were intended to provide process feedback and optimization to PAVAC. During the project, PAVAC completed one set of samples. However, due to a business reorganization, PAVAC choose not to proceed toward a second set of samples using their proprietary approach. The PAVAC technical goal was replaced by a Fermilab goal to determine whether high-purity aluminum could be attached to niobium by a system of welded stud anchors and fasteners. The project pivoted to evaluations of trial stud welded anchors using infrastructure and expertise similar to that applied to the PAVAC applied coatings.

43 PARTICLE ACCELERATORS↗

ERL-BASED COMPACT X-RAY FEL

We propose to develop an energy-recovery-linac (ERL)- based X-ray free-electron laser (XFEL). Taking advantage of the demonstrated high-efficiency energy recovery of the beam power in the ERL, the proposed concept offers the following benefits: i) recirculating the electron beam through high-gradient superconducting RF (SRF) cavities shortens the linac, ii) energy recovery in the SRF linac saves the klystron power and reduces the beam dump power, iii) the high average beam power produces a high average photon brightness. In addition, such a concept has the capability of delivering optimized high-brightness CW X-ray FEL performance at different energies with simultaneous multipole sources. In this paper, we will present the preliminary results on the study of feasibility, optics design and parameter optimization of such a device.

Lin, Fanglei↗

Architectural scaling tradeoffs in modular 3D bosonic quantum processors

We propose a modular three-dimensional bosonic quantum processor built from repeatable coupled-cavity modules linked by configurable interconnect networks. Using hardware-motivated graph-theoretic measures, we compare nearest-neighbor, hub-based, and hybrid architectures in terms of interconnect count, communication distance, resource concentration, and implementation complexity. Rather than identifying a universally optimal topology, our analysis shows how these architectures redistribute the costs of scaling, including wiring and port requirements, nonlocal communication distance, exposure to shared resources, routing bottlenecks, and scheduling overhead. Case studies of a \(3\times3\) processor and a larger hierarchical architecture further distinguish finite-size performance from asymptotic scaling. The resulting framework provides a systematic basis for evaluating modular three-dimensional bosonic processors and for identifying the device-level parameters required for quantitative hardware design.

Zhu, Shaojiang [Fermilab] (ORCID:0000000293180092)↗

A low-frequency buncher field-variation study on a 750 keV H – beam to increase Drift Tube Linac capture

We report low-frequency (such as 16.77 MHz) RF bunchers are widely used in RF accelerator systems for longitudinal compression of pulses into a single RF bucket, which increases instantaneous beam intensity for time-dependent studies. In this study, the dependency of capture into a 201.25 MHz Drift Tube Linac (DTL) was measured as a function of gap voltage for a 16.77 MHz buncher on chopped H - beam (approximately 25 ns at 750 keV, 10 mA peak current). The multiparticle code PARMILA was used to simulate the phase-space distribution of the 10 mA, 750 keV, H - beam at the entrance to DTL with a wide range of the Low-Frequency Buncher (LFB) field (10 kV to 35 kV). The measurement and simulation indicated that the DTL capture could be dilute (reduced) for a non-optimized buncher field to a pre-configured beamline geometry. The data shows that changing the bunch field while keeping the incoming beam current and energy constant does not significantly alter the beam’s emittance. However, downstream beam capture into the DTL is changed for a non-optimized phase-space bunching distance with the buncher field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity study of ignition capsule implosion performance on the hard x-ray spectral distribution of hohlraum

The paper investigates theoretically the sensitivities of ignition capsule implosion performance on the hard x-ray spectral distribution of hohlraum. In the simulation, the hohlraum radiation is represented by a Planckian spectrum for the main drive plus a gaussian bump centered at energy E{sub c} for preheating x-rays. Simulation results show that with the increasing of center energy E{sub c}, the Atwood number at the fuel-ablator interface increases rapidly due to the preheating and expanding of the inner undoped CH layer. The growing of Atwood number indicates the hydrodynamic instability (HI) growth and mixing at this interface. On the other hand, the increasing of E{sub c} results in a large density gradient scale length of ablation front and stabilizes the HI growth at ablation front. The changes of the hard x-ray spectrum have significant influences on other important implosion parameters including the ablator mass remaining, shock timing, implosion velocity, and yield as well. High-precision results on the hard x-ray spectral distribution of hohlraum are thus critical for optimizing the ignition capsule design to limit the HI growth.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Continuous on-sun solar thermochemical hydrogen production via an isothermal redox cycle

Solar thermochemical hydrogen production from water is a path towards a carbon-free sustainable hydrogen economy. Here, isothermal on-sun hydrogen production is demonstrated using active iron aluminate (hercynite) particles contained in dual fluidized bed reactors. The two fluidized beds were held in a single cavity solar receiver that was heated with a 10 kW high flux solar furnace. During 8 h of on-sun testing, 5.3 L of H 2 were generated with an average productivity of 597 umol H 2 /g using an intermittent process with optimized redox cycle times. Redox cycling was performed isothermally and continuously with equivalent oxidation and reduction times producing 547 umol H2/g over two cycles. These results show excellent agreement with the H 2 production measured in an 800X scaled-down electrically heated laboratory stagnation flow reactor and surpass on-sun H 2 production of current benchmark materials. The effect of environmental variability on the incident solar radiation and hydrogen production is evaluated during on-sun testing. Finally, a discussion of the important factors for scalability of the process to commercial applications is provided, highlighting the importance of robust containment and active materials. This work links current materials research and development with commercial implementation in an on-sun process and demonstrates the viability of solar thermochemical hydrogen production that leverages continuous isothermal redox cycling.

08 HYDROGEN↗

Update on the JLEIC Electron Collider Ring Design

We present an update on the lattice design of the electron ring of the Jefferson Lab Electron-Ion Collider (JLEIC). The electron and ion collider rings feature a unique figure-8 layout providing optimal conditions for preservation of beam polarization. The rings include two arcs and two intersecting long straight sections containing a low-beta interaction region (IR) with special optics for detector polarimetry, electron beam spin rotator sections, ion beam cooling sections, and RF-cavity sections. Recent development of the electron ring lattice has been focused on minimizing the beam emittance while providing an efficient non-linear chromaticity correction and large dynamic aperture. We describe and compare three lattice designs, from which we determine the best option.

Nosochkov, Y.↗