Space Station Freedom altitude strategy

The Space Station Freedom (SSF) altitude strategy provides guidelines and assumptions to determine an altitude profile for Freedom. The process for determining an altitude profile incorporates several factors such as where the Space Shuttle will rendezvous with the SSF, when reboosts must occur, and what atmospheric conditions exist causing decay. The altitude strategy has an influence on all areas of SSF development and mission planning. The altitude strategy directly affects the micro-gravity environment for experiments, propulsion and control system sizing, and Space Shuttle delivery manifests. Indirectly the altitude strategy influences almost every system and operation within the Space Station Program. Evolution of the SSF altitude strategy has been a very dynamic process over the past few years. Each altitude strategy in turn has emphasized a different consideration. Examples include a constant Space Shuttle rendezvous altitude for mission planning simplicity, or constant micro-gravity levels with its inherent emphasis on payloads, or lifetime altitudes to provide a safety buffer to loss of control conditions. Currently a new altitude strategy is in development. This altitude strategy will emphasize Space Shuttle delivery optimization. Since propellant is counted against Space Shuttle payload-to-orbit capacity, lowering the rendezvous altitude will not always increase the net payload-to-orbit, since more propellant would be required for reboost. This altitude strategy will also consider altitude biases to account for Space Shuttle launch slips and an unexpected worsening of atmospheric conditions. Safety concerns will define a lower operational altitude limit, while radiation levels will define upper altitude constraints. The evolution of past and current SSF altitude strategies and the development of a new altitude strategy which focuses on operational issues as opposed to design are discussed.

Mcdonald, Brian M.↗

Thermophysical Property Measurement and Materials Research in the NASA/MSFC Electrostatic Levitator

Containerless processing is an important tool for thermophysical property measurements and materials research. The freedom from a crucible allows processing of liquid materials in a metastable undercooled state, as well as allowing processing of high temperature and highly reactive melts. Electrostatic levitation (ESL) is a containerless method which provides a number of unique advantages, including the decoupling of positioning force from sample heating, the ability to operate in ultra-high vacuum or at moderate gas pressure (approximately 3 atm), and the ability to process non-conducting materials. ESL also has the potential to reduce internal flow velocities below those possible with electromagnetic, acoustic, or aero-acoustic techniques. The ESL facility at NASA's Marshall Space Flight Center (MSFC) is in use for thermophysical property measurements and materials research by a number of different internal and external investigators. The methods for obtaining access to the facility, as well as a summary of current capabilities and some future directions will be discussed. In electrostatic levitation, the acceleration of gravity (or residual acceleration in reduced gravity) is opposed by the action of an applied electric field on a charged sample. This positioning method is applicable to any material which can be electrically charged, whether solid or liquid, conducting, or insulating. Because the position of the sample is unstable, a 3-dimensional active control loop rapidly adjusts the applied field to maintain levitation and minimize motion of the sample. Heating lasers melt the sample, and may be adjusted to maintain specified thermal profiles. Microgravity allows electrostatic levitation to work even more effectively. With the need to cancel less than 1 milli-g, the applied field required is reduced from approximately 10 MV/m to approximately 10 kV/m. Alternatively, a microgravity ESL can position larger samples than is possible on the ground, or it can position samples which maintain their charge poorly. Microgravity also reduces the effects of buoyant convection and sedimentation. In the MSFC ESL, many different classes of experiments and measurements have been demonstrated in collaboration with many investigators. These capabilities include heat capacity measurement, phase diagram determination, and nucleation and growth experiments including nucleation rate, TTT curves, and phase selection. We have demonstrated the capability of triggering recalescence of an undercooled liquid sample without loss of levitation. Currently under development are techniques for measuring the surface tension, viscosity, and density of levitated samples, as well as other thermophysical properties. Expanded levitation capabilities including various gas environments for sample processing, sample rotation control and management of thermal gradients are under development for the MSFC ESL. Containerless processing allows research on materials which may not be processed any other way. Electrostatic levitation extends the range of containerless processing to include many materials and classes of materials which cannot be processed by conventional electromagnetic, acoustic, or aerodynamic levitation techniques.

Rogers, Jan↗

Heterogeneous Chemistry Involving Methanol in Tropospheric Clouds

In this report we analyze airborne measurements to suggest that methanol in biomass burning smoke is lost heterogeneously in clouds. When a smoke plume intersected a cumulus cloud during the SAFARI 2000 field project, the observed methanol gas phase concentration rapidly declined. Current understanding of gas and aqueous phase chemistry cannot explain the loss of methanol documented by these measurements. Two plausible heterogeneous reactions are proposed to explain the observed simultaneous loss and production of methanol and formaldehyde, respectively. If the rapid heterogeneous processing of methanol, seen in a cloud impacted by smoke, occurs in more pristine clouds, it could affect the oxidizing capacity of the troposphere on a global scale.

Tabazadeh, A.↗

Air Dehumidification using Ionic Liquid-Based Fiber Bundle Membrane Contactor

Air dehumidification is essential since excess moisture in the buildings causes discomfort to the occupants, encourages the production of air pathogens such as mold or mildew, and causes corrosion and rotting that degrade building materials. Existing moisture removal processes are mainly focused on condensation and desiccant (liquid or solid) techniques with direct contact between air and desiccant. However, these methods are energy-intensive, or desiccant might be lost or cause corrosion in the process. The main objective of this study is to investigate an ionic liquid-based liquid desiccant absorber based on a membrane fiber bundle. The novel system consists of membrane contactors containing bundles of 10,000 polypropylene fibers. The fiber bundles have 0.3 micron diameter, with ionic liquid flowing inside, and air flowing outside. The fibers provide a high contact area among phases: 1.4 m2 contact surface area in a 0.00015 m3 volume. The ionic liquid as a sorbent stipulates the selectivity for air, prevents the loss of solvent in the operation due to negligible volatility, provides fast diffusion due to low viscosity compared to common ionic liquids, and has high affinity and solubility in water. The dehumidification capacity of the membrane technology was experimentally investigated. The experimental results show that the ionic-liquid based membrane system can effectively remove excess moisture from the air. The novel fiber bundle dehumidification system has a system volume of 0.00798 m3 (7.98 L) and active heat and mass transfer surface area of 8.4 m2. It achieved an average dehumidification of 320 ± 25 W with a volumetric air flowrate of 3.1 m3/min (108 ft3/min).

Turnaoglu, Tugba↗

Nb3Sn Superconducting Cavity Developments for Heavy-ion Beams

Nb3Sn has been identified as the most promising next-generation superconducting material for accelerator cavities. This is due to the higher critical temperature (Tc = 18 K) of Nb3Sn compared to niobium (Tc = 9.2 K), which leads to greatly reduced RF losses in the cavity during 4.5 K operation. This allows two important changes during cavity and cryomodule design. First, the higher Tc leads to negligible BCS losses when operated at 4.5 K, which allows for a higher frequency to be used, translating to significantly smaller cavities and cryomodules. Second, the reduced dissipated power lowers the required cryogenic cooling capacity, meaning that cavities can feasibly be operated on 5-10 W cryocoolers instead of a centralized helium refrigeration plant. These plants and distribution systems are costly and complex, requiring skilled technicians for operation and maintenance. These fundamental changes present an opportunity for a paradigm shift in how low-beta linacs are designed and operated. Fabrication and testing results of first prototypes are discussed.

Petersen, T. [Argonne]↗

Demonstration of a Novel Technology to Manage Electricity Demand in Grid-Independent Military Microgrids

This research was conducted by the National Renewable Energy Laboratory (NREL) in collaboration with the S&C Electric Inc. through funding provided by the ESTCP. The project demonstrates use of cybersecure Automated Demand Response (ADR) technology to effectively manage microgrid loads during grid-independent, also known as "islanded," operation. When military microgrids become isolated from the main electrical grid, they are required to balance electricity supply and demand locally. Given that local generation may be constrained, the prevailing strategy involves shedding all but the most critical loads by tripping smart circuit breakers, which then necessitate manual resetting. This approach is generally implemented at the building level, which means that the buildings with mission-critical activities are exempt from load management and remain fully powered, whereas those deemed non-critical can experience a complete loss of service. In this research we developed a method that allows building automation systems to selectively control their assets in response to load shedding request from a microgrid controller, avoiding total loss of service in contrast to the conventional control approach. A commercial OpenADR client server by GridFabric is used for communication between the microgrid controller and the building management system (BMS). The microgrid controller monitors both generation capacity and various assets within the microgrid and issues a demand reduction request when necessary. This request is communicated to the OpenADR server via Modbus. Upon receiving the request, the OpenADR server forwards it to the BMS utilizing the OpenADR protocol. The BMS is pre-configured with various levels of load reduction strategies based on the controllable assets available, allowing for a nuanced approach to demand reduction. Both lab and field tests were performed that considered load shedding needed to achieve closed transition into island mode and to accommodate changing loads and power source availability while islanded. A commercial microgrid controller was used for these tests with normal programming within the expected constraints of the system capabilities. That is, the solution did not require any specialized modification to the code base of the controller. Given the latency of the round-trip communication path between the microgrid controller and the various devices involved with the load shed processes, there are certain scenarios for which the demonstrated solution are appropriate and some which are not. The methods described in this report can be used for load shedding/restoration during transitions between islanded and grid-tied modes of operation, as well as accommodating normal variations in load and the need to remove a power source from operation for maintenance. These methods should not be used for scenarios that require load shedding within a second or two such as sudden and unanticipated significant load increases or loss of power sources through equipment faults.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resistance of virus to extinction on bottleneck passages: study of a decaying and fluctuating pattern of fitness loss

RNA viruses display high mutation rates and their populations replicate as dynamic and complex mutant distributions, termed viral quasispecies. Repeated genetic bottlenecks, which experimentally are carried out through serial plaque-to-plaque transfers of the virus, lead to fitness decrease (measured here as diminished capacity to produce infectious progeny). Here we report an analysis of fitness evolution of several low fitness foot-and-mouth disease virus clones subjected to 50 plaque-to-plaque transfers. Unexpectedly, fitness decrease, rather than being continuous and monotonic, displayed a fluctuating pattern, which was influenced by both the virus and the state of the host cell as shown by effects of recent cell passage history. The amplitude of the fluctuations increased as fitness decreased, resulting in a remarkable resistance of virus to extinction. Whereas the frequency distribution of fitness in control (independent) experiments follows a log-normal distribution, the probability of fitness values in the evolving bottlenecked populations fitted a Weibull distribution. We suggest that multiple functions of viral genomic RNA and its encoded proteins, subjected to high mutational pressure, interact with cellular components to produce this nontrivial, fluctuating pattern.

Serial Passage↗

Atmospheric helium and geomagnetic field reversals.

The problem of the earth's helium budget is examined in the light of recent work on the interaction of the solar wind with nonmagnetic planets. It is proposed that the dominant mode of helium (He4) loss is ion pumping by the solar wind during geomagnetic field reversals, when the earth's magnetic field is very small. The interaction of the solar wind with the earth's upper atmosphere during such a period is found to involve the formation of a bow shock. The penetration altitude of the shock-heated solar plasma is calculated to be about 700 km, and ionization rates above this level are estimated for a cascade ionization (electron avalanche) process to average 10 to the 9th power ions/sq cm/sec. The calculated ionization rates and the capacity of the solar wind to remove ionized helium (He4) from the upper atmosphere during geomagnetic dipole reversals are sufficient to yield a secular equilibrium over geologic time scales. The upward transport of helium from the lower atmosphere under these conditions is found to be adequate to sustain the proposed loss rate.

Sheldon, W. R.↗

Implanting Transition Metal into Li 2 O-Based Cathode Prelithiation Agent for High-Energy-Density and Long-Life Li-Ion Batteries

Compensating the irreversible loss of limited active lithium (Li) is essentially important for improving the energy-density and cycle-life of practical Li-ion battery full-cell, especially after employing high-capacity but low initial coulombic efficiency anode candidates. Introducing prelithiation agent can provide additional Li source for such compensation. Herein, we precisely implant trace Co (extracted from transition metal oxide) into the Li site of Li 2 O, obtaining (Li 0.66 Co 0.11$\square$0.23 ) 2 O (CLO) cathode prelithiation agent. Further, the synergistic formation of Li vacancies and Co-derived catalysis efficiently enhance the inherent conductivity and weaken the Li-O interaction of Li 2 O, which facilitates its anionic oxidation to peroxo/superoxo species and gaseous O 2 , achieving 1642.7 mAh/g ~Li2O prelithiation capacity (≈980 mAh/g for prelithiation agent). Coupled 6.5 wt % CLO-based prelithiation agent with LiCoO 2 cathode, substantial additional Li source stored within CLO is efficiently released to compensate the Li consumption on the SiO/C anode, achieving 270 Wh/kg pouch-type full-cell with 92 % capacity retention after 1000 cycles.

25 ENERGY STORAGE↗

Wisconsin In Situ Penning (WISP) gauge: A versatile neutral pressure gauge to measure partial pressures in strong magnetic fields

A new type of in-vessel Penning gauge, the Wisconsin In Situ Penning (WISP) gauge, has been developed and successfully operated in the Wendelstein 7-X (W7-X) island divertor baffle and vacuum vessel. The capacity of the quantitative measurements of the neutral reservoir for light impurities, in particular, helium, is important for tokamaks as well as stellarator divertors in order to avoid fuel dilution and radiative energy loss. Penning gauges assisted by spectroscopy are a powerful tool to obtain the total neutral pressure as well as fractional neutral pressures of specific impurities. The WISP gauge is a miniaturized Penning gauge arrangement, which exploits the ambient magnetic field of magnetic confinement fusion experiments to establish the Penning discharge. Then, in situ spectroscopy is conducted to separate the fractional neutral pressures of hydrogen, helium, and possibly also other impurities. The WISP probe head was qualified using the magnetic field of the Magnetized Dusty Plasma Experiment at Auburn University between 0.25 T and 3.5 T [E. Thomas et al ., J. Plasma Phys. 81, 345810206 (2015)]. The in-depth quantitative evaluation for hydrogen and helium will be shown as well as an exploration of nitrogen, argon, and neon. A power law scaling between current I and pressure p, I = f (Gas,V) p n⁽Gas, B⁾ , was shown. The factor f is gas and anode potential dependent, while n is gas and magnetic field strength dependent. Pressure measurements from 0.1 mbar and down to 1 × 10 -5 mbar were achieved, demonstrating a reliable operating range for relevant pressure levels in the divertor and main vessel regions in current and future fusion devices, with a time resolution of up to 1 kHz. The lowest achievable pressure measurement increases with an increase in B and can be shifted with the anode potential V . At W7-X, the WISP probe head was mounted on an immersion tube setup that passes through the cryostat and places the probe head close to the plasma. Two probe heads were positioned in different divertor pump gaps, top and bottom, and one close to the plasma on the midplane in one module. The gauges were in situ calibrated together with the ASDEX pressure gauges [G. Haas and H.-S. Bosch, Vacuum 51, 39 (1998)]. Data were taken during the entire operation phase 1.2b, and measurements were coherent with other neutral gas pressure gauges. For the spectroscopic partial pressure measurements, channels of a spectroscopic detection system based on photo-multipliers, a so-called filterscope [R. J. Colchin et al ., Rev. Sci. Instrum. 74, 2068 (2003)], provided by the Oak Ridge National Lab were used.

47 OTHER INSTRUMENTATION↗

Challenges to Rural Service Transformers on Increased Electric Vehicle Charging Infrastructure

As Electric Vehicle (EV) electric charging demand increases so to does the corresponding load requirements for charging the vehicles. The expansion of power distribution assets is therefore a critical issue to address on whether rural service transformers can handle the increase in EV load demand. Large-scale EV deployment is likely to cause problems in the localized distributions systems bringing challenges such as increased load demand, increased system losses, and additional voltage drops. This paper investigates how rural service transformer resiliency plays an important role in these challenges. EV charging can create new load peaks exceeding the service transformer's rated capacity, thereby accelerating equipment aging. EV charging can also both positively and negatively affect transformer aging. The core purpose of this paper is to investigate that change in service life of rural service transformers.

Mukherjee, Srijib↗

VIC-Global Parameter Dataset Sensitivity with the Variable Infiltration Capacity Model: Evaluating the importance of dynamic land surface parameters when using the VIC-Global parameter dataset

Accurate prediction of runoff is essential to water resources management, flood risk assessment, and ecosystem protection. However, many hydrological models still have relatively substantial limitations when representing the influence of land use and land cover (LULC) on runoff generation and routing. Changes in LULC, such as deforestation, urban expansion, agricultural intensification, and wetland loss, have been shown to alter the water balance at the land surface through fundamental hydrologic processes (e.g., interception, infiltration, evapotranspiration, and soil storage). However, it remains an open question what the exact magnitude and timing of these impacts are for the spatial and temporal scales commonly used in engineering applications. In this analysis we focus on one aspect of recent LULC change for assessing human impacts, which is urbanization. Specifically we seek to determine the impacts of urbanization on the magnitude and timing of surface runoff and baseflow in HUC-12 basins in Clark County, Nevada which has experienced rapid urbanization. We use the Variable Infiltration Capacity (VIC) hydrology model with a widely used off-the-shelf dataset of land surface parameters, VIC-Global, both of which have been commonly used in the past for water and energy balance modeling for large scale hydrologic studies. We examine two scenarios where the first scenario removes all urbanized land cover and parameterizes those areas of the basins as barren or open shrubland. The second scenario tests the opposite case where all areas of the basins are classified as urban regardless of their present classification. The results from the VIC model show there is a low sensitivity for daily surface runoff between scenarios. The daily baseflow values indicate similar low sensitivity to the classification change during specific periods, but then have substantial differences during other period when large precipitation events are occurring. This is likely due to the assumed parameter values for the urban land cover classification made by the VIC-Global dataset. Using a static land cover parameterization is reasonable for large domain hydrology models that are being used for near-term planning horizons (<30 years). However, longer planning horizons where feedbacks between the atmosphere and land surface are important, especially in transient climate situations, considerations for how to update land surface parameters should be incorporated.

42 ENGINEERING↗

Achieving high rate performance in hybrid pristine-recycled cathodes using model-informed electrode designs

Direct recycling lithium-ion battery cathodes, a process that retains the engineered oxide structures from end-of-life materials, presents a cost-effective and energy-efficient alternative to other battery recycling methods. However, while direct-recycled cathodes have demonstrated performance comparable to that of pristine materials at low cycling rates, their high-rate performance remains uncertain. Morphology changes in cathode particles, a main mode of degradation, directly impact rate performance by limiting surface kinetics and solid-phase diffusion. If direct recycling processes do not sufficiently restore pristine-like morphologies, the recycled materials may retain structural defects that hinder high-rate performance. The present work uses a physics-based pseudo-2D model to simulate hybrid electrodes with pristine and artificially “aged/recycled” NMC materials to investigate potential impacts of incorporating performance-limited aged cathode materials into cells. The study highlights how differences in transport and kinetic properties can influence rate capabilities in mixed electrodes — particularly in high-loading cells in high-demand applications. However, model results also reveal a possible mitigation strategy via dual-layer electrode architectures with lower-performing materials positioned near the current collector. Simulations of 4.0 mAh cm −2 cells cycled at 4C using a dual-layer architecture provided approximately 5%–30% more capacity in constant-current protocols compared to homogeneously blended electrode architectures with the same loadings and mixed-material compositions. These findings highlight the importance of strategic electrode design in minimizing potential performance losses and facilitating the integration of recycled materials into high-performance batteries, advancing sustainable and cost-effective battery manufacturing.

25 ENERGY STORAGE↗

Kinetic Monte Carlo Framework for Coupled Degradation and Dehydration of Anion Exchange Membranes

Kinetic Monte Carlo (kMC) simulations, augmented with temporal-acceleration schemes, can efficiently handle stiff reaction-transport networks when fast processes rapidly relax to quasi-equilibrium on a fixed lattice. However, in glassy anion-exchange membranes (AEM), rare and irreversible chemical degradation events continuously reshape the nanoscale morphology, and the associated hydration and transport degrees of freedom remain far from a well-defined local equilibrium. This combination of evolving state space and nonequilibrated fast dynamics lies outside the scope of existing kMC acceleration frameworks. Here, to address this challenge, we introduce an auxiliary-particle kinetic Monte Carlo (AP-kMC) scheme. In AP-kMC, short-lived mobile particles spawned at degradation sites execute hop, water-elimination, and decay moves, enforcing rapid local relaxation of the hydration structure while preserving the stochastic rules of kMC. Parameterized with molecular-dynamics morphologies and experimental solution degradation kinetics, AP-kMC reproduces the evolution of ion-exchange capacity, water uptake, and conductivity, and reveals a feedback loop in which poorly hydrated sites degrade first and each degradation event induces further local dehydration. The resulting thinning and fragmentation of water channels cause loss of hydrophilic percolation and abrupt conductivity collapse well before complete charge loss. AP-kMC thus reframes AEM durability as a coupled degradation–drying–percolation problem and provides a transferable strategy to simulate reactive, out-of-equilibrium polymer electrolytes where local solvation controls reactivity.

organic↗

Modulating physicochemical interfaces enables li-rich oxides based ceramic solid-state li batteries under ambient conditions

Li-rich layered oxides exhibit promising potential applications in high-energy-density solid-state lithium metal batteries. Nevertheless, the strong oxidative oxygen species generate at high voltage, which poses great challenges to positive electrode-side interface stability. Herein, a robust in-situ polymerization gel polymer electrolyte with bifunctional additives is designed for interface modification. These additives, include lithium difluoro(oxalate) borate and LiPO 2 F 2 , regulate the Li + chemical environment in gel polymer electrolyte to enhance crosslink density without residual oligomer, which reduce gas generation and suppress contact loss, thus avoiding interfacial impedance divergence. Concurrently, the designed gel polymer electrolyte enables a wide electrochemical stability window (up to 4.7 V) and a high Li + transference number (0.82). Additionally, the additives induced F- and B-rich inorganic cathode-electrolyte interphase inhibits side reactions and oxygen/transition metal loss effectively, stabilizing the chemical interface. The as-constructed Li-rich layered oxides-based ceramic solid-state lithium metal batteries with gel polymer electrolyte interface modification exert a high discharge capacity of 276.5 mAh g -1 at 30 °C without external pressure, delivering a retention of 81.7% after 100 cycles at 25 mA g -1 during 2.0-4.7 V. This work provides a guideline for developing high-voltage solid-state lithium metal batteries via interfacial design.

Hu, Xinchao [Xiamen University (China)]↗

Warming decreases desert ecosystem functioning by altering biocrusts in drylands

Warming and precipitation fluctuations are changing desert ecosystems in global drylands. However, the effects of climate change on keystone species such as cryptogamic biocrust in drylands remain relatively under-investigated, even though biocrusts play a vital role in desert ecosystems. Here we conducted a long-term experiment (14 years) to simulate the responses of two main types of biocrusts to warming coupled with reduction in precipitation that was achieved by open-top chambers (OTCs) to simulate the predicted warming and precipitation decreasing under climate change scenario. We also conduct a structural analysis to evaluate the resulting changes in desert ecosystem functioning (carbon and nitrogen cycling). Neither warming and corresponding rainfall reduction treatments had a negative effect on lichen species richness, but both treatments reduced lichen cover and biomass. The negative effects of warming on moss-dominated crusts were much greater than those on lichen-dominated crusts. Although mosses and lichens had varying degree responses to warming, the loss of mosses and decreased lichen cover and biomass, as well as the shortening of the wet time, resulted in a reduction in carbon and nitrogen fixation, soil enzyme activity and water-holding capacity of biocrusts and topsoil. These impacts collectively change the water balance of drylands and weaken the hydrological and biogeochemical function of biocrusts. Synthesis and applications: Results from this long-term experiment suggest that the ecosystem C and N cycling and water balance of global drylands may be highly impacted by climate change, in part because of the response of biocrusts, which contribute an important implication for both dryland restoration and earth system dynamics.

54 ENVIRONMENTAL SCIENCES↗

LBNF/DUNE Nitrogen Refrigeration System Update

The Deep Underground Neutrino Experiment (DUNE) is supported by the infrastructure of the Long Baseline Neutrino Facility (LBNF). The central feature of DUNE is the liquid argon filled cryostats, which house the neutrino detector components. In order to maintain the argon in a liquid state, heat must be continuously removed. Argon condensers will remove this heat, and liquefy the argon, through the evaporation of liquid nitrogen. The supply of liquid nitrogen relies heavily on a near-industrial scale nitrogen refrigeration/liquefaction system. The nitrogen system will be a closed loop, in which the liquid nitrogen is supplied to users and, after being vaporized, is recycled to the nitrogen liquefaction units to be liquefied again. The system will also include nitrogen generation, to increase inventory in the closed loop, as well as to make up for losses. All of this will be installed nearly one mile underground (1.5km) on the 4850 level of the Sanford Underground Research Facility (SURF). The final DUNE vision requires 400kW of liquid nitrogen cooling capacity. Based on the operation modes and phased installation of the experiment, modularity of this cooling capacity is required. Nitrogen liquefaction will occur in four units which will afford a wide operational range of production (nominally 100kW each). Due to the experiment’s location deep underground in an inactive gold mine, there are unique and challenging constraints. These include limited access, footprint, and utilities. This poster describes the engineering effort, and provides an overview of the refrigeration system. The design includes a unique compressor arrangement which is covered in detail. Pictures and models are included where possible to help visualize the system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Chemical contributions to silicon anode calendar aging are dominant over mechanical contributions

Silicon (Si) anodes are a promising candidate for increasing the energy density of lithium (Li)-ion batteries for electric vehicles. However, they have recently been identified as having poor calendar life that is insufficient for commercial needs, in addition to the well-known issue of their poor cycle life resulting from large volume expansion. Here, a specially designed protocol with variable rest periods between intermittent cycling is used to evaluate the impact of the mechanical disruption of Si and solid electrolyte interphase (SEI) from cycling on calendar aging measurements. Si was found to undergo more mechanical degradation during calendar aging with intermittent cycling than graphite. However, Si anode capacity fade was still dominated by time, especially for rest periods greater than or equal to 1 month between cycling. Postmortem dQ/dV half-cell analysis indicated this was mainly due to Li inventory loss and an increase in electrode resistance. Isothermal microcalorimetry further demonstrated that Si passivation is more disrupted than graphite passivation with intermittent cycling and suggested that there may be a chemical buildup of a detrimental species in the electrolyte, leading to a large spike in heat after the Si and SEI are disrupted by cycling.

25 ENERGY STORAGE↗