Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

GOLDEN GRAVITATIONAL LENSING SYSTEMS FROM THE SLOAN LENS ACS SURVEY. I. SDSS J1538+5817: ONE LENS FOR TWO SOURCES ,

We present a gravitational lensing and photometric study of the exceptional strong lensing system SDSS J1538+5817, identified by the Sloan Lens Advanced Camera for Survey. The lens is a luminous elliptical galaxy at redshift z{sub l} = 0.143. Using Hubble Space Telescope public images obtained with two different filters, the presence of two background sources lensed, respectively, into an Einstein ring and a double system is ascertained. Our new spectroscopic observations, performed at the Nordic Optical Telescope, reveal unequivocally that the two sources are located at the same redshift z{sub s} = 0.531. We investigate the total (luminous and dark) mass distribution of the lens between 1 and 4 kpc from the galaxy center by means of parametric and non-parametric lensing codes that describe the multiple images as point-like objects. Bootstrapping and Bayesian analyses are performed to determine the uncertainties on the quantities relevant to the lens mass characterization. Several disparate lensing models provide results that are consistent, given the errors, with those obtained from the best-fit model of the lens mass distribution in terms of a singular power-law ellipsoid model. In particular, the lensing models agree on: (1) reproducing accurately the observed positions of the images; (2) predicting a nearly axisymmetric total mass distribution, centered and oriented as the light distribution; (3) measuring a value of 8.11{sup +0.27}{sub -0.59} x 10{sup 10} M{sub sun} for the total mass projected within the Einstein radius of 2.5 kpc; and (4) estimating a total mass density profile slightly steeper than an isothermal one (rho(r){proportional_to}r{sup -2.33+0.43{sub -0.20}}). A fit of the Sloan Digital Sky Survey multicolor photometry with composite stellar population models provides a value of 20{sup +1}{sub -4} x 10{sup 10} M{sub sun} for the total mass of the galaxy in the form of stars and of 0.9{sup +0.1}{sub -0.2} for the fraction of projected luminous over total mass enclosed inside the Einstein radius. By combining lensing (total) and photometric (luminous) mass measurements, we differentiate the lens mass content in terms of luminous and dark matter components. This two-component modeling, which is viable only in extraordinary systems like SDSS J1538+5817, leads to a description of the global properties of the galaxy dark matter halo. Extending these results to a larger number of lens galaxies would considerably improve our understanding of galaxy formation and evolution processes in the LAMBDACDM scenario.

79 ASTRONOMY AND ASTROPHYSICS↗

Upgrade of the Lyman-alpha diagnostic system on DIII-D for main chamber edge neutral studies

The LLAMA (Lyman Alpha Measurement Apparatus) pinhole camera diagnostic had previously been deployed on DIII-D to measure radial profiles of the Lyman-α (Ly-α) deuterium neutral line brightness across the plasma boundary in the lower chamber to infer neutral deuterium density and ionization rate profiles. This system has recently been upgraded with a new diagnostic head, named ALPACA, that also encloses two pinhole cameras and duplicates the LLAMA views in the upper chamber. Similar to LLAMA, ALPACA provides two times 20 lines of sight, viewing the plasma edge on the inboard and outboard sides with a radial resolution of ~2.5 cm (FWHM) and an effective time resolution of ~1 ms that allows for the investigation of inter-ELM dynamics. The extended Ly-α system provides better coverage to study neutrals in experiments with various plasma shapes utilizing both the upper and lower divertors. Furthermore, post-campaign calibration of the LLAMA diagnostic has successfully been demonstrated for the first time. This was facilitated by various upgrades to the calibration set-up and detailed measurements of the emissivity distribution of the Ly-α calibration source using a pinhole collimator. It was found that the sensitivity of the inboard LLAMA pinhole camera was reduced by a factor of 2.0 ± 0.2 over the course of six months of plasma operation in 2021. In conclusion, the upgraded Ly-α system, equipped with improved absolute calibration, will provide key input for neutral fueling and pedestal particle transport studies and for 2D edge transport code validation on the DIII-D tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integrated Monitoring of Macroalgae Farms Using Acoustics and UUV Sensing

The vision of this project was to develop an integrated system for autonomous underwater vehicle (AUV) monitoring of offshore kelp farms using acoustic, environmental, and optical sensors. This project supports the overall MARINER goals of developing an offshore kelp aquaculture industry to produce low-carbon or carbon-neutral biofuels. The project commenced in the spring of 2018 and used laboratory experiments to test the efficacy of acoustic sensors for monitoring kelp farm lines and growing kelp biomass. Sensors were then integrated onto two AUVs as well as an autonomous surface vehicle in order to establish the optimal type, price point, and vehicle to most efficiently monitor kelp farm structures, kelp biomass, and the surrounding environment. Multiple field deployments of these vehicles and sensors in Massachusetts, New Hampshire, and Maine confirmed that farm lines and kelp could be visualized and that monitoring the spatial patterns of environmental variables was possible. The COVID-19 pandemic severely limited fieldwork activities and laboratory testing, with deployments around kelp farms not occurring again until January 2021. Time spent away from the field focused on data visualization and the development of a low-cost, vessel-based sensor system. Unfortunately, the low-cost system experienced a disk failure during its first deployment and due to multiple resignations from the project team further engineering and development was not possible. Additionally, final results from acoustic sensor testing in 2021 were also not able to be completed due to the resignation of the postdoc leading the analysis. Despite these setbacks, multiple avenues for further development of optical imagery processing from the 360-degree Kelpcam camera and testing of the low-cost sensor system may be possible.

09 BIOMASS FUELS↗

MAXI Nova Alert System and the Latest Scientific Results

MAXI, Monitor of All-sky X-ray Image, is the first astronomical telescope onboard the ISS. One of the main goals of our mission is to discover new transient objects by scanning more than 95% of the sky every {approx}92 min with two types of X-ray cameras, Gas Slit Camera (GSC) and Solid-state Slit Camera (SSC). We have developed a completely new data analysis system, a nova alert system, to find transient objects and send alerts to the world as soon as possible. Here we describe the current status of the system, and transient objects discovered with the system.

79 ASTRONOMY AND ASTROPHYSICS↗

An approach to characterizing spatial aspects of image system blur

Quantitative X-ray radiographic imaging systems that utilize a charged couple device (CCD) camera connected to a thick, monolithic scintillator can exhibit blur that varies spatially across the field of view, especially for thick scintillators used in pulse-power radiography of dynamically compressed objects. Here, a three-point approach to estimating and accounting for this effect is demonstrated by (a) using a local estimation technique to measure the effect of blurring a calibration object at key locations across the field of view, (b) combining each of the local estimates into a spatially varying blurring function via partitions of unity interpolation, and (c) resolving the effects of that blur on the image by solving an ill-posed inverse problem using a spatially varying regularization term. The technique is demonstrated on synthetic examples and actual radiographs collected at the Naval Research Laboratory’s (NRL)Mercury pulsed power facility.

97 MATHEMATICS AND COMPUTING↗

Advances in imaging instrumentation for nuclear cardiology

Advances in imaging instrumentation and technology have greatly contributed to nuclear cardiology. Dedicated cardiac SPECT cameras incorporating novel, highly efficient detector, collimator, and system designs have emerged with the expansion of nuclear cardiology. Solid-state radiation detectors incorporating cadmium zinc telluride, which directly convert radiation to electrical signals and yield improved energy resolution and spatial resolution and enhanced count sensitivity geometries, are increasingly gaining favor as the detector of choice for application in dedicated cardiac SPECT systems. Additionally, hybrid imaging systems in which SPECT and PET are combined with X-ray CT are currently widely used, with PET/MRI hybrid systems having also been recently introduced. The improved quantitative SPECT/CT has the potential to measure the absolute quantification of myocardial blood flow and flow reserve. Rapid development of silicon photomultipliers leads to enhancement in PET image quality and count rates. In addition, the reduction of emission–transmission mismatch artifacts via application of accurate time-of-flight information, and cardiac motion de-blurring aided by anatomical images, are emerging techniques for further improvement of cardiac PET. This article reviews recent advances such as these in nuclear cardiology imaging instrumentation and technology, and the corresponding diagnostic benefits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting melt pool depth and grain length using multiple signatures from in-situ single camera two-wavelength imaging pyrometry for laser powder bed fusion

In laser powder bed fusion (LPBF), the in-situ process signatures are known to have a direct correlation with the microstructural properties of the solidified melt pool (MP). It is known that the MP cooling and heating rates, and laser processing parameters can critically determine the grain structure and thereby affect the part properties. The objective of this work is to study the feasibility of using in-process, high-speed imaging pyrometry for evaluating the solidified MP properties “below” the surface, such as depth and microstructural properties. To accomplish this, we employ an in-house single camera-based two-wavelength imaging pyrometry (STWIP) system for monitoring the printing of single-scan tracks with Inconel 718 on a commercial LPBF printer (EOS M290). Further, the lab designed STWIP system is a coaxial high-speed (>10,000 fps) imaging system capable of monitoring MP temperature, morphology, and intensity profiles. The temperature measurements from STWIP are emissivity independent. The STWIP measured MP signatures of the printed tracks are correlated with the ex-situ microscopy characterized MP depth and the average grain lengths. From the data analysis, using support vector machine (SVM)-based regression models, we found that the MP temperature signatures are crucial for an accurate prediction of MP depth and the grain length, thus validating the novelty and necessity of the developed in-situ monitoring methods and analysis.

36 MATERIALS SCIENCE↗

Q-Switched Nd: YAG Laser Micro-Machining System

In this paper, we present the design of a low cost Q-switched Nd: YAG laser micro-machining system for photo masks fabrication. It consists of: Nd:YAG laser source, beam delivery system, X-Y table, PC, The CCD camera and TV monitor. The synchronization between the laser source and the X-Y table is realised by NI PCI-7342, the two axis MID-7602 and LabVIEW based program. The first step of this work consists of engraving continuous and discontinuous lines on a thin film metal with a 100 {mu}m resolution by using the YG 980 Quantel Q-switched Nd:YAG laser.

36 MATERIALS SCIENCE↗

A comparison between soft x-ray and magnetic phase data on the Madison symmetric torus

The Soft X-Ray (SXR) tomography system on the Madison Symmetric Torus uses four cameras to determine the emissivity structure of the plasma. This structure should directly correspond to the structure of the magnetic field; however, there is an apparent phase difference between the emissivity reconstructions and magnetic field reconstructions when using a cylindrical approximation. The difference between the phase of the dominant rotating helical mode of the magnetic field and the motion of the brightest line of sight for each SXR camera is dependent on both the camera viewing angle and the plasma conditions. Holding these parameters fixed, this phase difference is shown to be consistent over multiple measurements when only toroidal or poloidal magnetic field components are considered. These differences emerge from physical effects of the toroidal geometry which are not captured in the cylindrical approximation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DETECTION OF GALACTIC CENTER SOURCE G2 AT 3.8 μm DURING PERIAPSE PASSAGE

We report new observations of the Galactic Center source G2 from the W. M. Keck Observatory. G2 is a dusty red object associated with gas that shows tidal interactions as it nears its closest approach with the Galaxy's central black hole. Our observations, conducted as G2 passed through periapse, were designed to test the proposal that G2 is a 3 Earth mass gas cloud. Such a cloud should be tidally disrupted during periapse passage. The data were obtained using the Keck II laser guide star adaptive optics system (LGSAO) and the facility near-infrared camera (NIRC2) through the K' [2.1 μm] and L' [3.8 μm] broadband filters. Several results emerge from these observations: (1) G2 has survived its closest approach to the black hole as a compact, unresolved source at L', (2) G2's L' brightness measurements are consistent with those over the last decade, (3) G2's motion continues to be consistent with a Keplerian model. These results rule out G2 as a pure gas cloud and imply that G2 has a central star. This star has a luminosity of ∼30 L {sub ☉} and is surrounded by a large (∼2.6 AU) optically thick dust shell. The differences between the L' and Br-γ observations can be understood with a model in which L' and Br-γ emission arises primarily from internal and external heating, respectively. We suggest that G2 is a binary star merger product and will ultimately appear similar to the B-stars that are tightly clustered around the black hole (the so-called S-star cluster)

79 ASTRONOMY AND ASTROPHYSICS↗

Testing the Technique for the Cluster Analysis of Acoustic Emission Pulse Arrays under the Formation of a Conical Glass Granulate Pile

The technique for the cluster analysis and the classification of registered acoustic emission (AE) data arrays was used for the determination of the isolated phases upon the transition from the regular to the avalanche process of damage accumulation in a physical simulation model. The damage accumulation phases were modeled in the process of formation of a conical glass granulate pile. Their registration was performed by an AE control system synchronized with a high-speed video camera.

36 MATERIALS SCIENCE↗

Sandia Optical Fringe Analysis Slope Tool (SOFAST) v. 2018.11.20

SOFAST is used to characterize the surface slope of reflective mirrors for solar applications. SOFAST uses a large monitor or projection screen to display fringe patterns, and a machine vision camera to image the reflection of these patterns in the subject mirror. From these images, a detailed map of surface normals can be generated and compared to design or fitted mirror shapes. SOFAST uses standard Fringe Reflection (Deflectometry) approaches to measure the mirror surface normals. SOFAST uses an extrinsic analysis of key points on the facet to locate the camera and monitor relative to the facet coordinate system. It then refines this position based on the measured surface slope and integrated shape of the mirror facet. The facet is placed into a reference frame such that key points on the facet match the design facet in orientation and position. This is key to evaluating a facet as suitable for a specific solar application. SOFAST reports the measurements of the facet as detailed surface normal location in a format suitable for ray tracing optical analysis codes. SOFAST also reports summary information as to the facet fitted shape (monomial) and error parameters. Useful plots of the error distribution are also presented.

Yellowhair, Julius↗

Micro-Bubble Experiments at the Van de Graaff Accelerator

In order to test and verify the experimental designs at the linear accelerator (LINAC), several micro-scale bubble ("micro-bubble") experiments were conducted with the 3-MeV Van de Graaff (VDG) electron accelerator. The experimental setups included a square quartz tube, sodium bisulfate solution with different concentrations, cooling coils, gas chromatography (GC) system, raster magnets, and two high-resolution cameras that were controlled by a LabVIEW program. Different beam currents were applied in the VDG irradiation. Bubble generation (radiolysis), thermal expansion, thermal convection, and radiation damage were observed in the experiments. Photographs, videos, and gas formation (O 2 + H 2 ) data were collected. The micro-bubble experiments at VDG indicate that the design of the full-scale bubble experiments at the LINAC is reasonable.

43 PARTICLE ACCELERATORS↗

Designing Unmanned Aerial Survey Monitoring Program to Assess Floating Litter Contamination

Monitoring marine contamination by floating litter can be particularly challenging since debris are continuously moving over a large spatial extent pushed by currents, waves, and winds. Floating litter contamination have mostly relied on opportunistic surveys from vessels, modeling and, more recently, remote sensing with spectral analysis. This study explores how a low-cost commercial unmanned aircraft system equipped with a high-resolution RGB camera can be used as an alternative to conduct floating litter surveys in coastal waters or from vessels. The study compares different processing and analytical strategies and discusses operational constraints. Collected UAS images were analyzed using three different approaches: (i) manual counting (MC), using visual inspection and image annotation with object counts as a baseline; (ii) pixel-based detection, an automated color analysis process to assess overall contamination; and (iii) machine learning (ML), automated object detection and identification using state-of-the-art convolutional neural network (CNNs). Our findings illustrate that MC still remains the most precise method for classifying different floating objects. ML still has a heterogeneous performance in correctly identifying different classes of floating litter; however, it demonstrates promising results in detecting floating items, which can be leveraged to scale up monitoring efforts and be used in automated analysis of large sets of imagery to assess relative floating litter contamination.

Almeida, Sílvia (ORCID:0000000320636826)↗

Orbits and Masses of Binaries from Speckle Interferometry at SOAR

We present results from Speckle inteferometric observations of 15 visual binaries and one double-line spectroscopic binary, carried out with the HRCam Speckle camera of the SOAR 4.1 m telescope. These systems were observed as a part of an on-going survey to characterize the binary population in the solar vicinity, out to a distance of 250 pc. We obtained orbital elements and mass sums for our sample of visual binaries. The orbits were computed using a Markov Chain Monte Carlo algorithm that delivers maximum likelihood estimates of the parameters, as well as posterior probability density functions that allow us to evaluate their uncertainty. Their periods cover a range from 5 yr to more than 500 yr; and their spectral types go from early A to mid M, implying total system masses from slightly more than 4M{sub ⊙} down to 0.2M {sub ⊙}. They are located at distances between approximately 12 and 200 pc, mostly at low Galactic latitude. For the double-line spectroscopic binary YSC8, we present the first combined astrometric/radial-velocity orbit resulting from a self-consistent fit, leading to individual component masses of 0.897 ± 0.027 M {sub ⊙} and 0.857 ± 0.026 M {sub ⊙}; and an orbital parallax of 26.61 ± 0.29 mas, which compares very well with the Gaia DR2 trigonometric parallax (26.55 ± 0.27 mas). In combination with published photometry and trigonometric parallaxes, we place our objects on an H-R diagram and discuss their evolutionary status. We also present a thorough analysis of the precision and consistency of the photometry available for them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SOFAST: Sandia Optical Fringe Analysis Slope Tool

SOFAST is used to characterize the surface slope of reflective mirrors for solar applications. SOFAST uses a large monitor or projections screen to display fringe patterns, and a machine vision camera to image the reflection of these patterns in the subject mirror. From these images, a detailed map of surface normals can be generated and compared to design or fitted mirror shapes. SOFAST uses standard Fringe Reflection (Deflectometry) approaches to measure the mirror surface normals. SOFAST uses an extrinsic analysis of key points on the facet to locate the camera and monitor relative to the facet coordinate system. It then refines this position based on the measured surface slope and integrated shape of the mirror facet. The facet is placed into a reference frame such that key points on the facet match the design facet in orientation and position. This is key to evaluating a facet as suitable for a specific solar application. SOFAST reports the measurements of the facet as detailed surface normal location in a format suitable for ray tracing optical analysis codes. SOFAST also reports summary information as to the facet fitted shape (monomial) and error parameters. Useful plots of the error distribution are also presented.

Andraka, Charles E.↗

Design and Performance Testing of a Linear Array of Position-Sensitive Virtual Frisch-Grid CdZnTe Detectors for Uranium Enrichment Measurements

Abstract— Arrays of position-sensitive virtual Frisch-grid CdZnTe (CZT) detectors with enhanced energy resolution have been proposed for spectroscopy and imaging of gamma-ray sources in different applications. The flexibility of the array design, which can employ CZT crystals with thicknesses up to several centimeters in the direction of electron drift, allows for integration into different kinds of field-portable instruments. These can include small hand-held devices, compact gamma cameras and large field-of-view imaging systems. In this work, we present results for a small linear array of such detectors optimized for the low-energy region, 50-400 keV gamma-rays, which is principally intended for incorporation into hand-held instruments. There are many potential application areas for such instruments, including uranium enrichment measurements, storage monitoring, dosimetry and other safeguards-related tasks that can benefit from compactness and isotope-identification capability. The array described here provides a relatively large area with a minimum number of readout channels, which potentially allows the developers to avoid using an ASIC-based electronic readout by substituting it with hybrid preamplifiers followed by digitizers. The array prototype consists of six (5x5.7x25 mm3) CZT detectors positioned in a line facing the source to achieve a maximum exposure area (~10 cm2). Each detector is furnished with 5 mm-wide charge-sensing pads placed near the anode. The pad signals are converted into X-Y coordinates for each interaction event, which are combined with the cathode signals (for determining the Z coordinates) to give 3D positional information for all interaction points. This information is used to correct the response non-uniformity caused by material inhomogeneity, which therefore allows the usage of standard-grade (unselected) CZT crystals, while achieving high-resolution spectroscopic performance for the instrument. In this presentation we describe the design of the array, the results from detailed laboratory tests, and preliminary results from measurements taken during a field test.

36 MATERIALS SCIENCE↗

Design and Performance Testing of a Linear Array of Position-Sensitive Virtual Frisch-Grid CdZnTe Detectors for Uranium Enrichment Measurements

Arrays of position-sensitive virtual Frisch-grid CdZnTe (CZT) detectors with enhanced energy resolution have been proposed for spectroscopy and imaging of gamma-ray sources in different applications. The flexibility of the array design, which can employ CZT crystals with thicknesses up to several centimeters in the direction of electron drift, allows for integration into different kinds of field-portable instruments. These can include small hand-held devices, compact gamma cameras and large field-of-view imaging systems. In this work, we present results for a small linear array of such detectors optimized for the low-energy region, 50-400 keV gamma-rays, which is principally intended for incorporation into hand-held instruments. There are many potential application areas for such instruments, including uranium enrichment measurements, storage monitoring, dosimetry and other safeguards-related tasks that can benefit from compactness and isotope-identification capability. The array described here provides a relatively large area with a minimum number of readout channels, which potentially allows the developers to avoid using an ASIC-based electronic readout by substituting it with hybrid preamplifiers followed by digitizers. The array prototype consists of six (5x5.7x25 mm3) CZT detectors positioned in a line facing the source to achieve a maximum exposure area (~10 cm2). Each detector is furnished with 5 mm-wide charge-sensing pads placed near the anode. The pad signals are converted into X-Y coordinates for each interaction event, which are combined with the cathode signals (for determining the Z coordinates) to give 3D positional information for all interaction points. This information is used to correct the response non-uniformity caused by material inhomogeneity, which therefore allows the usage of standard-grade (unselected) CZT crystals, while achieving high-resolution spectroscopic performance for the instrument. In this presentation we describe the design of the array, the results from detailed laboratory tests, and preliminary results from measurements taken during a field test.

36 MATERIALS SCIENCE↗