Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibrated”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Lidar aerosol backscatter measurements - Systematic, modeling, and calibration error considerations

Sources of systematic, modeling, and calibration errors that affect the interpretation and calibration of lidar aerosol backscatter data are discussed. The treatment pertains primarily to ground-based pulsed CO2 lidars that probe the troposphere and are calibrated using hard calibration targets. However, a large part of the analysis is relevant to other types of lidar system such as lidars operating at other wavelengths; CW focused lidars; airborne or earth-orbiting lidars; lidars measuring other regions of the atmosphere; lidars measuring nonaerosol elastic or inelastic backscatter; and lidars employing other calibration techniques.

Kavaya, M. J.↗

Calibration of satellite sensors after launch

A simple and accurate method for the postflight calibration of satellite Visible Infrared Spin-Scan Radiometers (VISSR) is presented, and the results of inflight testing are reported. The calibration source for the VISSR with its effective wavelength of 610 nm is the radiance of sunlight, measured in calibrated reflectance units, scattered by the atmospheric gas above ocean which is far from land. Only the lowest 20 percent of the full-scale VISSR response is calibrated. VISSR testing aboard two geostationary operational evironmental satellites between 1980 and 1983 showed significant calibration coefficient variations of only + or - 12 percent and + or - 2 percent. Good agreement was found between values of aerosol optical thickness measured by VISSR and those measured from the ground.

Fraser, R. S.↗

Supplementary calibration test of the tip-aerodynamics- and acoustics-test pressure transducers

A calibration test is described that was performed to supplement the normal calibration of the 188 pressure transducers used in the Tip Aerodynamics and Acoustics Test. This calibration led to the identification of 15 transducers which had a slope change of greater than 7% from the initial calibration. The calibration procedure is described and the results presented. The effect of the slope changes on the pressure distributions are described, followed by a method to compensate for these changes.

Watts, M. E.↗

Calibration and comparison of the NASA Lewis free-piston Stirling engine model predictions with RE-1000 test data

A free-piston Stirling engine performance code is being upgraded and validated at the NASA Lewis Research Center under an interagency agreement between the Department of Energy's Oak Ridge National Laboratory and NASA Lewis. Many modifications were made to the free-piston code in an attempt to decrease the calibration effort. A procedure was developed that made the code calibration process more systematic. Engine-specific calibration parameters are often used to bring predictions and experimental data into better agreement. The code was calibrated to a matrix of six experimental data points. Predictions of the calibrated free-piston code are compared with RE-1000 free-piston Stirling engine sensitivity test data taken at NASA Lewis. Resonable agreement was obtained between the code predictions and the experimental data over a wide range of engine operating conditions.

Geng, Steven M.↗

Microhardness and lattice parameter calibrations of the oxygen solid solutions of unalloyed alpha-titanium and Ti-6Al-2Sn-4Zr-2Mo

Standards were prepared for calibrating microanalyses of dissolved oxygen in unalloyed alpha-Ti and Ti-6Al-2Sn-4Zr-2Mo. Foils of both of these materials were homogenized for 120 hours in vacuum at 871 C following short exposures to the ambient atmosphere at 854 C that had partially oxidized the foils. The variation of Knoop microhardness with oxygen content was calibrated for both materials using 15-g and 5-g indentor loads. The unit-cell lattice parameters were calibrated for the unalloyed alpha-Ti. Example analyses demonstrate the usefulness of these calibrations and support an explanation of an anomaly in the lattice parameter variation. The results of the calibrations have been tabulated and summarized using predictive equations.

Wiedemann, K. E.↗

Automatic calibration of space based manipulators and mechanisms

Four tasks in manipulator kinematic calibration are summarized. Calibration of a seven degree of freedom manipulator was simulated. A calibration model is presented that can be applied on a closed-loop robot. It is an expansion of open-loop kinematic calibration algorithms subject to constraints. A closed-loop robot with a five-bar linkage transmission was tested. Results show that the algorithm converges within a few iterations. The concept of model differences is formalized. Differences are categorized as structural and numerical, with emphasis on the structural. The work demonstrates that geometric manipulators can be visualized as points in a vector space with the dimension of the space depending solely on the number and type of manipulator joint. Visualizing parameters in a kinematic model as the coordinates locating the manipulator in vector space enables a standard evaluation of the models. Key results include a derivation of the maximum number of parameters necessary for models, a formal discussion on the inclusion of extra parameters, and a method to predetermine a minimum model structure for a kinematic manipulator. A technique is presented that enables single point sensors to gather sufficient information to complete a calibration.

Everett, Louis J.↗

Calibration and comparison of the NASA Lewis free-piston Stirling engine model predictions with RE-1000 test data

A free-piston Stirling engine performance code is being upgraded and validated at the NASA Lewis Research Center under an interagency agreement between the Department of Energy's Oak Ridge National Laboratory and NASA Lewis. Many modifications were made to the free-piston code in an attempt to decrease the calibration effort. A procedure was developed that made the code calibration process more systematic. Engine-specific calibration parameters are often used to bring predictions and experimental data into better agreement. The code was calibrated to a matrix of six experimental data points. Predictions of the calibrated free-piston code are compared with RE-1000 free-piston Stirling engine sensitivity test data taken at NASA Lewis. Reasonable agreement was obtained between the code prediction and the experimental data over a wide range of engine operating conditions.

Geng, Steven M.↗

Radiometric calibration of IR Fourier transform spectrometers - Solution to a problem with the High-Resolution Interferometer Sounder

A calibrated Fourier transform spectrometer, known as the High-Resolution Interferometer Sounder (HIS), has been flown on the NASA U-2 research aircraft to measure the infrared emission spectrum of the earth. The primary use - atmospheric temperature and humidity sounding - requires high radiometric precision and accuracy (of the order of 0.1 and 1 C, respectively). To meet these requirements, the HIS instruments, the HIS instrument performs inflight radiometric calibration, using observations of hot and cold blackbody reference sources as the basis for two-point calibrations at each wavenumber. Initially, laboratory tests revealed a calibration problem with brightness temperature errors as large as 15 C between 600 and 900/cm. The symptom of the problem, which occurred in one of the three spectral bands of HIS, was a source-dependent phase response. Minor changes to the calibration equations completely eliminated the anomalous errors. The new analysis properly accounts for the situation in which the phase response for radiance from the instrument itself differs from that for radiance from an external source. The mechanism responsible for the dual phase response of the HIS instrument is identified as emission from the interferometer beam splitter.

Revercomb, Henry E.↗

Sensitivity of satellite-derived net shortwave irradiance at the Earth's surface to radiometric calibration

The effect of radiometric calibration uncertainties on satellite-derived net shortwave irradiance at the Earth's surface was examined. Net shortwave irradiance sensitivity to calibration is expressed as a function of two basic components that depend on surface and cloud albedo sensitivities, respectively. The analysis of these sensitivities for a wide range of atmospheric and surface conditions, as well as radiation geometries, shows that a 10 percent uncertainty in the calibration induces up to 40 W/sqm errors in instantaneous net shortwave irradiance (negative when the calibration uncertainty is positive). The maximum relative errors are obtained in overcast conditions when cloud albedos are high. On a monthly time scale, the induced error becomes typically 13 W/sqm in the tropics and 16 W/sqm in higher latitude regions during summer. The error almost vanishes at high latitudes during winter. A 10 percent positive uncertainty in the calibration gives a net shortwave irradiance error similar to that induced by the 3 hr sampling of the ISCCP Project.

Gautier, C.↗

The optical field angle distortion calibration feasibility study for the Hubble Space Telescope fine guidance sensors

The results of an analytical study to investigate the feasibility of calibrating the Hubble Space Telescope's (HST's) fine guidance sensors (FGSs) within HST mission accuracy limits are presented. The study has two purposes: (1) to determine the mathematical feasibility of the optical field angle distortion (OFAD) calibration algorithm and (2) to confirm that the OFAD, plate scale, and FGS-to-FGS alignment calibration algorithms produced a calibration of the FGSs that satisfied mission requirements. The study concluded that the mathematical specification of the OFAD algorithm is adequate and permits a determination of the FGS calibration parameters (accurate to better than 0.003 arc-second) sufficient to meet the mission requirements. The algorithms implemented, the characteristics of the simulated data and procedures for data analysis, and the study's results are discussed. In addition, several useful techniques for improving the stability and accuracy of the OFAD solution are outlined.

Luchetti, K.↗

Calibration of polarimetric radar systems with good polarization isolation

A practical technique is proposed for calibrating single-antenna polarimetric radar systems using a metal sphere plus any second target with a strong cross-polarized radar cross section. This technique assumes perfect isolation between antenna ports. It is shown that all magnitudes and phases (relative to one of the like-polarized linear polarization configurations) of the radar transfer function can be calibrated without knowledge of the scattering matrix of the second target. Comparison of the values measured (using this calibration technique) for a tilted cylinder at X-band with theoretical values shows agreement within + or - 0.3 dB in magnitude and + or - 5 degrees in phase. The radar overall cross-polarization isolation was 25 dB. The technique is particularly useful for calibrating a radar under field conditions, because it does not require the careful alignment of calibration targets.

Sarabandi, Kamal↗

Airborne Calibration Of An Orbiting Radiometer

Experiment demonstrates feasibility of using recently calibrated airborne radiometer to calibrate satellite-borne radiometer monitoring Earth and not calibrated since before launch. Calibration technique helps to assure Earth scientists of accuracy of satellite radiometric measurements taken during long time. Optical train of orbiting radiometer degraded slowly and sensitivities of detectors and gains of amplifiers changed slowly in outer-space environment, but frequent calibrations by airborne-radiometer technique make it possible to compensate for these changes.

Smith, Gilbert R.↗

Boeing infrared sensor (BIRS) calibration facility

The Boeing Infrared Sensor (BIRS) Calibration Facility represents a major capital investment in optical and infrared technology. The facility was designed and built for the calibration and testing of the new generation large aperture long wave infrared (LWIR) sensors, seekers, and related technologies. Capability exists to perform both radiometric and goniometric calibrations of large infrared sensors under simulated environmental operating conditions. The system is presently configured for endoatmospheric calibrations with a uniform background field which can be set to simulate the expected mission background levels. During calibration, the sensor under test is also exposed to expected mission temperatures and pressures within the test chamber. Capability exists to convert the facility for exoatmospheric testing. The configuration of the system is described along with hardware elements and changes made to date are addressed.

Hazen, John D.↗

Calibration of polarimetric radar systems

A practical technique is proposed for calibrating single-antenna polarimetric radar systems using a metal sphere plus any second target with a strong cross-polarized radar cross section. It is shown that all magnitudes and phases (relative to one of the like-polarized linear polarization configurations) of the radar transfer function can be calibrated without knowledge of the scattering matrix of the second target. Comparison of values measured (using this calibration technique) for a tilted cylinder at X-band with theoretical values shows agreement with + or - 0.3 dB in magnitude and + or - 5 deg in phase. The technique is particularly useful for calibrating a radar under field conditions because it does not require careful alignment of calibration targets.

Sarabandi, K.↗

Thermal design, testing, and analysis of the Cosmic Background Explorer's external calibrator

The thermal design of a calibrator used to correlate the collected data with an absolute reference onboard of the Cosmic Background Explorer is considered. Since flight conditions could not be simulated in ground testing, the design was qualified by analysis and testing. The requirements imposed on the calibrator are outlined, along with spacecraft hardware modifications aimed at reducing the thermal load on the calibrator. A geometric mathematical model created in order to obtain view factors from the cryogenic instruments to the spacecraft and dewar is discussed. It is shown that the calibrator met or exceeded all of its performance requirements, and that the modifications to such energy sources as the thermal shield and differential microwave radiometers proved effective in reducing the radiative energy the calibrator received from the spacecraft to acceptable levels.

Mosier, Carol L.↗

Use of rotating pinholes and reticles for calibration of cloud droplet instrumentation

Calibration devices for the Forward Scattering Spectrometer Probe (FSSP) and the Optical Array Probe (OAP) were developed. The device used with the FSSP is a rotating pinhole calibrator. It utilizes light diffracted by a pinhole of a known diameter to simulate scattered light from a water droplet. This device can be used to calibrate the FSSP, measure the FSSP's optical collection angles and for instrument alignment and troubleshooting. The device used with the OAP is a rotating reticle calibrator. Chrome disks of a known diameter on the reticle are used for calibration of the OAP and for determining the OAP's response to out-of-focus particles in the probe volume.

Hovenac, Edward A.↗

Experiments In Calibration Of Synthetic-Aperture Radar

Report describes international collaboration on experiments in calibration of synthetic-aperture radar (SAR) systems. Purposes of experiments were to: address problems associated with calibration of data, cross-calibrate between sets of imaging-radar data obtained by different systems, test designs of ground calibration equipment, and find candidate sites for calibration of future satellite-borne SAR systems.

Freeman, Anthony↗

High accuracy fuel flowmeter. Phase 2C and 3: The mass flowrate calibration of high accuracy fuel flowmeters

A facility for the precise calibration of mass fuel flowmeters and turbine flowmeters located at AMETEK Aerospace Products Inc., Wilmington, Massachusetts is described. This facility is referred to as the Test and Calibration System (TACS). It is believed to be the most accurate test facility available for the calibration of jet engine fuel density measurement. The product of the volumetric flow rate measurement and the density measurement, results in a true mass flow rate determination. A dual-turbine flowmeter was designed during this program. The dual-turbine flowmeter was calibrated on the TACS to show the characteristics of this type of flowmeter. An angular momentum flowmeter was also calibrated on the TACS to demonstrate the accuracy of a true mass flowmeter having a 'state-of-the-art' design accuracy.

Craft, D. William↗