Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calculation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Ab-initio calculation of structural, electronic, and optical characterizations of the intermetallic trialuminides ScAl{sub 3} compound

We present first-principles study of the electronic and the optical properties for the intermetallic trialuminides ScAl{sub 3} compound using the full-potential linear augmented plane wave method within density-functional theory. We have employed the generalized gradient approximation (GGA), which is based on exchange-correlation energy optimization to calculate the total energy. Also we have used the Engel-Vosko GGA formalism, which optimizes the corresponding potential for calculating the electronic band structure and optical properties. The electronic specific heat coefficient ({gamma}), which is a function of density of states, can be calculated from the density of states at Fermi energy N(E{sub F}). The N(E{sub F}) of the phase L1{sub 2} is found to be lower than that of D0{sub 22} structure which confirms the stability of L1{sub 2} structure. We found that the dispersion of the band structure of D0{sub 22} is denser than L1{sub 2} phase. The linear optical properties were calculated. The evaluations are based on calculations of the energy band structure. - Graphical abstract: Crystal structure of L1{sub 2} (a) and D0{sub 22} (b) phases of ScAl{sub 3} compound.

36 MATERIALS SCIENCE↗

Effect of electron correlation in Sr(Ca)Ru{sub 1-x}Cr{sub x}O{sub 3}: Density functional calculation

We have investigated the electronic structure of Sr(Ca)Ru{sub 1-x}Cr{sub x}O{sub 3} using the full potential linearized augmented plane wave method by different approximation such as LSDA and LSDA+U. The LSDA calculation suggest that Cr{sup 4+}-Ru{sup 4+} hybridization is responsible for the high Curie temperature T{sub C} in SrRu{sub 1-x}Cr{sub x}O{sub 3}, but it cannot completely describe its physical behavior. Our LSDA+U DOS results for SrRu{sub 1-x}Cr{sub x}O{sub 3} clearly establishes renormalization of the intra-atomic exchange strength at the Ru sites, arising from the Cr-Ru hybridization. The antiferromagnetic coupling of Cr{sup 3+} with Ru{sup 4+,5+} lattice increases the screening, which is consistent with the low magnetic moment of the Ru ions. The more distorted Ca-based compounds as compared to the Sr-based systems shows that the hybridization mechanism is not relevant for these compounds. The bigger exchange splitting of Ru 4d and Cr 3d at the Fermi level with Ru{sup 4+,5+} and Cr{sup 3+,4+} orbital occupancies of CaRu{sub 0.75}Cr{sub 0.25}O{sub 3} in the LSDA+U calculation, compared with that of the LSDA calculation, shows that repulsion between electrons tend to keep the localized spins from overlapping. The low screening of the Ru t{sub 2g} electrons increases T{sub C} in the Ca-based systems, which is consistent with the both high Ru exchange splitting and magnetic moment. The insulating behavior of the high Cr-doped systems can be explained by considering the Ru{sup 4+}+Cr{sup 4+{yields}}Ru{sup 5+}+Cr{sup 3+} charge transfer. - Graphical Abstract: We have investigated the electronic structure of Sr(Ca)Ru{sub 1-x}Cr{sub x}O{sub 3} using different ab-initio calculation such as LSDA and LSDA+U approximation. The antiferromagnetic hybridization of Cr{sup 3+} with Ru{sup 4+,5+} lattice increases the screening, which is consistent with the low magnetic moment of the Ru ions. The LSDA+U calculation for the more distorted Cr impurity doped Ca-based ruthenate compounds as compared to the Sr-based systems shows repulsion between electrons, which tends to keep the localized spins from overlapping.

36 MATERIALS SCIENCE↗

String Method for Protein–Protein Binding Free-Energy Calculations

A powerful computational strategy to determine the equilibrium association constant of two macromolecules with explicit-solvent molecular dynamics (MD) simulations is the "geometric route", which considers the reversible physical separation of the bound complex in solution. Nonetheless, multiple challenges remain to render this type of methodology reliable and computationally efficient in practice. In particular, in one, formulation of the geometric route relies on the potential of mean force (PMF) for physically separating the two binding partners restrained along a straight axis, which must be selected prior to the calculation. However, practical applications indicate that the calculation of the separation PMF along the predefined rectilinear pathway may be suboptimal and slowly convergent. Recognizing that a rectilinear straight separation pathway is generally not representative of how the protein complex physically separates in solution, we put forth a novel theoretical framework for binding free-energy calculations, leaning on the optimal curvilinear minimum free-energy path (MFEP) determined from the string method. The proposed formalism is validated by comparing the results obtained using both rectilinear and curvilinear pathways for a prototypical host-guest complex formed by cucurbit[7]uril (CB[7]) binding benzene, and for the barnase-barstar protein complex. On the basis of multi-microsecond MD calculations, we find that the calculations following the traditional rectilinear pathway and the string-based curvilinear pathway agree quantitatively, but convergence is faster with the latter.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visible Light Absorption of N-Doped TiO2 Rutile Using (LR/RT)-TDDFT and Active Space EOMCCSD Calculations

We have performed detailed ground and excited state calculations of pure and N-doped TiO2 rutile to model and analyze the experimentally observed UV/Vis spectrum. Using our embedding model we have performed both linear-response (LR) and real-time (RT) TDDFT calculations of the excited states of the pure and N-doped systems. We have also studied the lowest excitations using high-level active space equation-of-motion coupled cluster (EOMCC) approaches involving all single and inter-band double excitations. We compare and contrast the nature of the excitations in detail for the pure and doped systems and also provide an analysis of the excited-state density using our RT-TDDFT calculations. Our calculations indicate a lowering of the band gap and verify the role of the N3- states on the observed spectrum of N-doped TiO2 rutile as suggested by experimental findings. Both RT-TDDFT and EOMCC calculations show that the excitations in pure TiO2 are more delocalized compared with the N-doped system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calculation of nuclear masses using image reconstruction techniques

Several methods have been developed to calculate and predict nuclear masses over the last 70 years. The accuracy of the present state-of-the-art nuclear mass models is impressive, because these quantities can be calculated with an average 0.05 % precision. However this precision level is still insufficient to deal with nuclear reactions of astrophysical interest, especially r-process ones. Different approaches exist to calculate nuclear masses, ranging from the simple Bethe-Weizsaecker Liquid Drop Formula (LDM) to the sophisticated Finite Range Droplet Model calculations or the microscopic Hartree-Fock-Bogoliuvob techniques from first principles, using Skyrme or Gogny parametrizations of the nucleon-nucleon interaction. Here we suggest a new method to calculate this fundamental property of the atomic nucleus, using a completely phenomenological point of view. Our method is based in the analysis of the differences between measured masses and LDM predictions, which contains information related to those ingredients not taken into account in the LDM formula, such as shell closures, nuclear deformations and residual nuclear interactions. The differences are arranged in a two dimensional plot which can be viewed as an incomplete image of the full chart of nuclides, equivalent to a product of the full image and a binary mask. In order to remove the distortions produced by this mask we employ an algorithm, well known in astronomy, used to remove artificial effects present in the astrophysical images collected through telescopes. This algorithm is called the CLEAN method. It is one of a number of methods which exists to deconvolve undesirable effects in images and to extrapolate or reconstruct missing parts in them. By using the CLEAN method we can fit measured masses with an r.m.s error of less than 100 keV. We have performed several checks and concluded that its utilization must be carried out carefully in order to obtain reliable results in the zone of unknown masses between the driplines. We also outline potential applications of the present approach.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

New Global Calculation of Nuclear Masses and Fission Barriers for Astrophysical Applications

The FRDM(1992) mass model [1] has an accuracy of 0.669 MeV in the region where its parameters were determined. For the 529 masses that have been measured since, its accuracy is 0.46 MeV, which is encouraging for applications far from stability in astrophysics. We are developing an improved mass model, the FRDM(2008). The improvements in the calculations with respect to the FRDM(1992) are in two main areas. (1) The macroscopic model parameters are better optimized. By simulation (adjusting to a limited set of now known nuclei) we can show that this actually makes the results more reliable in new regions of nuclei. (2) The ground-state deformation parameters are more accurately calculated. We minimize the energy in a four-dimensional deformation space ({epsilon}{sub 2}, {epsilon}{sub 3}, {epsilon}{sub 4}, {epsilon}{sub 6},) using a grid interval of 0.01 in all 4 deformation variables. The (non-finalized) FRDM (2008-a) has an accuracy of 0.596 MeV with respect to the 2003 Audi mass evaluation before triaxial shape degrees of freedom are included (in progress). When triaxiality effects are incorporated preliminary results indicate that the model accuracy will improve further, to about 0.586 MeV.We also discuss very large-scale fission-barrier calculations in the related FRLDM (2002) model, which has been shown to reproduce very satisfactorily known fission properties, for example barrier heights from {sup 70}Se to the heaviest elements, multiple fission modes in the Ra region, asymmetry of mass division in fission and the triple-humped structure found in light actinides. In the superheavy region we find barriers consistent with the observed half-lives. We have completed production calculations and obtain barrier heights for 5254 nuclei heavier than A = 170 for all nuclei between the proton and neutron drip lines. The energy is calculated for 5009325 different shapes for each nucleus and the optimum barrier between ground state and separated fragments is determined by use of an ''immersion'' technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Calculation Method of Lateral Strengths and Ductility Factors of Constructions with Shear Walls of Different Ductility

For seismic design, ductility-related force modification factors are named R factor in Uniform Building Code of U.S, q factor in Euro Code 8 and Ds (inverse of R) factor in Japanese Building Code. These ductility-related force modification factors for each type of shear elements are appeared in those codes. Some constructions use various types of shear walls that have different ductility, especially for their retrofit or re-strengthening. In these cases, engineers puzzle the decision of force modification factors of the constructions. Solving this problem, new method to calculate lateral strengths of stories for simple shear wall systems is proposed and named 'Stiffness--Potential Energy Addition Method' in this paper. This method uses two design lateral strengths for each type of shear walls in damage limit state and safety limit state. Two lateral strengths of stories in both limit states are calculated from these two design lateral strengths for each type of shear walls in both limit states. Calculated strengths have the same quality as values obtained by strength addition method using many steps of load-deformation data of shear walls. The new method to calculate ductility factors is also proposed in this paper. This method is based on the new method to calculate lateral strengths of stories. This method can solve the problem to obtain ductility factors of stories with shear walls of different ductility.

58 GEOSCIENCES↗

Effect of Embolization Material in the Calculation of Dose Deposition in Arteriovenous Malformations

In this work it is studied the impact of the incorporation of high Z materials (embolization material) in the dose calculation for stereotactic radiosurgery treatment for arteriovenous malformations. A statistical analysis is done to establish the variables that may impact in the dose calculation. To perform the comparison pencil beam (PB) and Monte Carlo (MC) calculation algorithms were used. The comparison between both dose calculations shows that PB overestimates the dose deposited. The statistical analysis, for the quantity of patients of the study (20), shows that the variable that may impact in the dose calculation is the volume of the high Z material in the arteriovenous malformation. Further studies have to be done to establish the clinical impact with the radiosurgery result.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calculation of continuum damping of Alfvén eigenmodes in tokamak and stellarator equilibria

In an ideal magnetohydrodynamic (MHD) plasma, shear Alfvén eigenmodes may experience dissipationless damping due to resonant interaction with the shear Alfvén continuum. This continuum damping can make a significant contribution to the overall growth/decay rate of shear Alfvén eigenmodes, with consequent implications for fast ion transport. One method for calculating continuum damping is to solve the MHD eigenvalue problem over a suitable contour in the complex plane, thereby satisfying the causality condition. Such an approach can be implemented in three-dimensional ideal MHD codes which use the Galerkin method. Analytic functions can be fitted to numerical data for equilibrium quantities in order to determine the value of these quantities along the complex contour. This approach requires less resolution than the established technique of calculating damping as resistivity vanishes and is thus more computationally efficient. The complex contour method has been applied to the three-dimensional finite element ideal MHD Code for Kinetic Alfvén waves. In this paper, we discuss the application of the complex contour technique to calculate the continuum damping of global modes in tokamak as well as torsatron, W7-X and H-1NF stellarator cases. To the authors' knowledge, these stellarator calculations represent the first calculation of continuum damping for eigenmodes in fully three-dimensional equilibria. The continuum damping of global modes in W7-X and H-1NF stellarator configurations investigated is found to depend sensitively on coupling to numerous poloidal and toroidal harmonics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Calculation of reinforced-concrete frame strength under a simultaneous static cross section load and a column lateral impact

When designing buildings with reinforced concrete that are planned to resist dynamic loads it is necessary to calculate this structural behavior under operational static and emergency impact and blast loads. Calculations of the structures under shock-wave loads can be performed by solving dynamic equations that do not consider static loads. Due to this fact the calculation of reinforced concrete frame under a simultaneous static and dynamic load in full 3d settings becomes a very non trivial and resource consuming problem. This problem can be split into two tasks. The first one is a shock-wave problem that can be solved using software package RANET-3, which allows solving the problem using finite elements method adapted for dynamic task. This method calculates strain-stress state of the material and its dynamic destruction, which is considered as growth and consolidation of micro defects under loading. On the second step the results of the first step are taken as input parameters for quasi static calculation of simultaneous static and dynamic load using finite elements method in AMP Civil Engineering-11.

36 MATERIALS SCIENCE↗

The origin of linear scaling Fock matrix calculation with density prescreening

A theorem was proven, which reads that the number of nonzero two-electron integrals scales linearly with respect to the number of basis functions for large molecular systems. This permits to show that linear scaling property of the Fock matrix calculation with using density prescreening arises due to linear scaling properties of the number of nonzero two-electron integrals and the number of leading matrix elements of density matrix. This property is reinforced by employing the density prescreening technique. The use of the density difference prescreening further improves the linear scaling property of the Fock matrix calculation method. As a result, the linear scaling regime of the Fock matrix calculation can begin from the number of basis functions of 2000–3000 in dependence on the basis function type in molecular calculations. It was also shown that the conventional algorithm of Fock matrix calculation from stored nonzero two-electron integrals with density prescreening possesses linear scaling property.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Exact restoration of Galilei invariance in density functional calculations with quantum Monte Carlo

We investigate some aspects of the connection between mean-field and ab-initio calculations for any-nucleon systems employing the Gogny effective interaction. In particular, we present variational Monte Carlo calculations of 4 He and 16 O, for which we extended the formalism of the linear method to the case of a density-dependent Hamiltonian. Monte Carlo calculations using an uncorrelated basis reduce to Hartree-Fock ones, but Galilean invariance can be preserved, contrary to the usual treatment. An analysis of the results obtained with the Gogny force when used in conjunction with correlated wave functions has also been performed. Here, the calculations show the collapse of the deuteron, leading to a set of unphysical predictions for the structure of heavier nuclei. This behavior remarks the different role of the Gogny effective interaction as compared to bare interactions typically used in fully microscopic calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast calculation of diffraction patterns from an ensemble of aligned molecules

We report an algorithm to calculate electron diffraction patterns for molecules with anisotropic angular distribution, which is significantly faster than existing methods. The algorithm uses a transform to convert the molecular orientation distribution, which is a function of three Euler angles, to the atom-pair distribution functions which depend on the polar and azimuthal angles. The diffraction signal can then be calculated from the atom-pair distributions. We demonstrate the computation method numerically by calculating electron diffraction patterns for a symmetric top molecule (trifluoroiodomethane) and an asymmetric top molecule (formaldehyde) and show that it reduces the calculation time by approximately two orders of magnitude compared to the standard brute-force method. Here, the method can also be applied to the calculation of x-ray diffraction patterns.

74 ATOMIC AND MOLECULAR PHYSICS↗

Discrete beta dose kernel matrices for nuclides applied in targeted radionuclide therapy (TRT) calculated with MCNP5

Purpose: Radiopharmaceuticals administered in targeted radionuclide therapy (TRT) rely to a great extent not only on beta-emitting nuclides but also on emitters of monoenergetic electrons. Recent advances like combined PET/CT devices, the consequential coregistration of both data, the concept of using beta couples for diagnosis and therapy, respectively, as well as the development of voxel models offer a great potential for developing TRT dose calculation systems similar to those available for external beam treatment planning. The deterministic algorithms in question for this task are based on the convolution of three-dimensional matrices, one representing the activity distribution and the other the dose point kernel. This study aims to report on three-dimensional kernel matrices for various nuclides used in TRT. Methods: The Monte Carlo code MCNP5 was used to calculate discrete dose kernels of beta particles including the contributions from their respective secondary radiation in soft tissue for the following nuclides: {sup 32}P, {sup 33}P, {sup 67}Cu, {sup 89}Sr, {sup 90}Y, {sup 103}Rh{sup m}, {sup 131}I, {sup 177}Lu, {sup 186}Re, and {sup 188}Re. For each nuclide a kernel cube of 10x10x10 mm{sup 3} was calculated, the dimensions of a voxel being 1 mm{sup 3}. Additional kernels with voxel sizes of 3x3x3 mm{sup 3} were simulated. Results: Comparison with the S-value data regarding {sup 32}P, {sup 89}Sr, {sup 90}Y, and {sup 131}I of the MIRD committee which were calculated with the EGS4 code showed a very good agreement, the secondary particle transport of {sup 90}Y being the only exception. Documented analytical kernels on the other side show deviations very close and very far to the source. Conclusions: The good accordance with the only discrete dose kernels published up to date justifies the method chosen. Together with the additional six nuclides, this report provides a considerable database for three-dimensional kernel matrices with regard to beta radionuclides applied in TRT. In contrast to analytical dose point kernels, the discrete kernels elude the problem of overestimation near the source and take energy depositions into account, which occur beyond the range of the continuous-slowing-down approximation (csda range). Recalculation of the 1x1x1 mm{sup 3} kernels to other dose kernels with varying voxel dimensions, cubic or noncubic, is shown to be easily manageable and thereby provides a resolution-independent system of dose calculation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-67: Clinical Implementation and Evaluation of the Acuros Dose Calculation Algorithm

Purpose: The main aim of the current study is to present a detailed description of the implementation of the Acuros XB Dose Calculation Algorithm, and subsequently evaluate its clinical impacts by comparing it with AAA algorithm. Methods: The source models for both Acuros XB and AAA were configured by importing the same measured beam data into Eclipse treatment planning system. Both algorithms were evaluated by comparing calculated dose with measured dose on a homogeneous water phantom for field sizes ranging from 6cm × 6cm to 40cm × 40cm. Central axis and off-axis points with different depths were chosen for the comparison. Similarly, wedge fields with wedge angles from 15 to 60 degree were used. In addition, variable field sizes for a heterogeneous phantom were used to evaluate the Acuros algorithm. Finally, both Acuros and AAA were tested on VMAT patient plans for various sites. Does distributions and calculation time were compared. Results: On average, computation time is reduced by at least 50% by Acuros XB compared with AAA on single fields and VMAT plans. When used for open 6MV photon beams on homogeneous water phantom, both Acuros XB and AAA calculated doses were within 1% of measurement. For 23 MV photon beams, the calculated doses were within 1.5% of measured doses for Acuros XB and 2% for AAA. When heterogeneous phantom was used, Acuros XB also improved on accuracy. Conclusion: Compared with AAA, Acuros XB can improve accuracy while significantly reduce computation time for VMAT plans.

60 APPLIED LIFE SCIENCES↗

SU-C-BRF-04: Delivered 4D Dose Calculation for Lung-VMAT Patients Using In- Treatment CBCT and LINAC Log Data

Purpose: To verify the delivered four-dimensional (4D) dose distribution for the lung VMAT using in-treatment 4D cone-beam CT (CBCT) and LINAC log data. Methods: Three patients for lung stereotactic radiotherapy (SRT) were treated by single-arc volumetric modulated arc therapy (VMAT) created by SmartArc in Pinnacle v9.2 (Philips, USA).Kilovoltage (kV) projection images were acquired during VMAT delivery using the x-ray volumetric imager, XVI (Elekta, UK). LINAC log data were also recorded via iCom interface (Elekta, UK). Subsequently, the iCom data format was converted to Pinnacle data format, thereby allowing Pinnacle to read actual MLC positions, jaw positions, gantry angles and MUs. These parameters were categorized into four groups according to patient's respiratory phase. The patient respiratory phase was determined from kV-projection images by in-house phase recognizing software. By exporting these data back to Pinnacle, in-treatment dose distributions for each respiratory phase were obtained by combining calculated dose having a particular phase. The 4D CBCT were reconstructed by in-house program. The density in the structures on the CBCT was overridden by the average density in the corresponding structures on the planning CT for the dose calculation. The dose indexes, such as maximum, minimum, mean dose in the target were compared among the plan, in-treatment 3D calculation, and in-treatment 4D calculation. Results: The day-to-day variation of the delivered dose was observed for all three patients. The maximum difference was 5.9% for the minimum dose in the target. Difference for the mean dose was found to be small (1.1% at maximum). Conclusion: We have obtained in-treatment dose distribution for each of the different respiratory phases using in-treatment 4D CBCT and LINAC log data during lung VMAT delivery. Our result indicate a small but significant dose difference between the 3D and 4D calculations for the case of large target traveling.

60 APPLIED LIFE SCIENCES↗

SU-E-T-37: A GPU-Based Pencil Beam Algorithm for Dose Calculations in Proton Radiation Therapy

Purpose: Recent developments in radiation therapy have been focused on applications of charged particles, especially protons. Over the years several dose calculation methods have been proposed in proton therapy. A common characteristic of all these methods is their extensive computational burden. In the current study we present for the first time, to our best knowledge, a GPU-based PBA for proton dose calculations in Matlab. Methods: In the current study we employed an analytical expression for the protons depth dose distribution. The central-axis term is taken from the broad-beam central-axis depth dose in water modified by an inverse square correction while the distribution of the off-axis term was considered Gaussian. The serial code was implemented in MATLAB and was launched on a desktop with a quad core Intel Xeon X5550 at 2.67GHz with 8 GB of RAM. For the parallelization on the GPU, the parallel computing toolbox was employed and the code was launched on a GTX 770 with Kepler architecture. The performance comparison was established on the speedup factors. Results: The performance of the GPU code was evaluated for three different energies: low (50 MeV), medium (100 MeV) and high (150 MeV). Four square fields were selected for each energy, and the dose calculations were performed with both the serial and parallel codes for a homogeneous water phantom with size 300×300×300 mm3. The resolution of the PBs was set to 1.0 mm. The maximum speedup of ∼127 was achieved for the highest energy and the largest field size. Conclusion: A GPU-based PB algorithm for proton dose calculations in Matlab was presented. A maximum speedup of ∼127 was achieved. Future directions of the current work include extension of our method for dose calculation in heterogeneous phantoms.

60 APPLIED LIFE SCIENCES↗

SU-F-T-148: Are the Approximations in Analytic Semi-Empirical Dose Calculation Algorithms for Intensity Modulated Proton Therapy for Complex Heterogeneities of Head and Neck Clinically Significant?

Purpose: Evaluate the differences in dose distributions between the proton analytic semi-empirical dose calculation algorithm used in the clinic and Monte Carlo calculations for a sample of 50 head-and-neck (H&N) patients and estimate the potential clinical significance of the differences. Methods: A cohort of 50 H&N patients, treated at the University of Texas Cancer Center with Intensity Modulated Proton Therapy (IMPT), were selected for evaluation of clinical significance of approximations in computed dose distributions. H&N site was selected because of the highly inhomogeneous nature of the anatomy. The Fast Dose Calculator (FDC), a fast track-repeating accelerated Monte Carlo algorithm for proton therapy, was utilized for the calculation of dose distributions delivered during treatment plans. Because of its short processing time, FDC allows for the processing of large cohorts of patients. FDC has been validated versus GEANT4, a full Monte Carlo system and measurements in water and for inhomogeneous phantoms. A gamma-index analysis, DVHs, EUDs, and TCP and NTCPs computed using published models were utilized to evaluate the differences between the Treatment Plan System (TPS) and FDC. Results: The Monte Carlo results systematically predict lower dose delivered in the target. The observed differences can be as large as 8 Gy, and should have a clinical impact. Gamma analysis also showed significant differences between both approaches, especially for the target volumes. Conclusion: Monte Carlo calculations with fast algorithms is practical and should be considered for the clinic, at least as a treatment plan verification tool.

60 APPLIED LIFE SCIENCES↗