Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building energy data analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

698 records · Page 39

Adaptive Computing for Scale-Up Problems

Adaptive Computing is an application-agnostic outer loop framework to strategically deploy simulations and experiments to guide decision making for scale-up analysis. Resources are allocated over successive batches, which makes the allocation adaptive to some objective such as optimization or model training. The framework enables the characterization and management of uncertainties associated with predictive models of complex systems when scale-up questions lead to significant model extrapolation. A key advancement of this framework is its integration of multi-fidelity surrogate modeling, uncertainty management, and automated orchestration of various computing and experimentation resources into a single integrated software package. This enables efficient multi-fidelity modeling across multiple computing resources by incorporating real-world constraints such as relative queue times and throughput on individual machines into the multi-fidelity sampling decision. We discuss applications of this framework to problems in the renewable energy space, including biofuels production, material synthesis, perovskite crystal growth, and building electrical loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IEA Wind TCP Task 49: Reference Site Conditions for Floating Wind Arrays

This report, prepared within Work package 1 of IEA Wind Task 49, presents reference site conditions for floating wind arrays to serve as a design basis for the techno-economic design of reference floating wind arrays. Data of the reference sites presented here are publicly available in an open database and thus support fast development and comparable design of floating wind arrays for various relevant conditions. The development of these reference sites drew on existing open access datasets and ongoing research projects of task participants. Six classes were identified that describe relevant key conditions for the design and development of floating wind arrays: met-ocean conditions, seabed conditions, coastal infrastructure, environmental impact, socio-economic impact, as well as regulations and permissions. The reference sites for the techno-economic design of floating wind arrays are based on a concept with building blocks to synthesize purpose-built site representations. In each of the identified classes with influencing design factors, building blocks are used to describe the characteristic properties and their spread. However, the latter three classes (i.e., environmental impact, socio-economic impact, regulations and permissions) are not included in the reference site conditions due to limited knowledge and lack of reliable criteria to quantify their impact on the techno-economic design in numeric parameters. Building blocks with key parameters for the techno-economic design of floating wind arrays are provided for met-ocean conditions, seabed conditions, and coastal infrastructure. For met-ocean conditions, multiple sites were selected for detailed analysis that represent a range of conditions across the pipeline of floating wind projects. Wind conditions and sea states are separated, and each location considers both the severity of wind and waves e.g. one site may have a moderate wave condition but severe wind condition. From this pipeline, eleven representative sites were selected where both site-specific analysis was available within the consortium, and where they represent different parts of the global pipeline. The eleven sites are: Hannibal (Italy), Humboldt (US), Ulsan (South Korea), MoneyPoint One (Ireland), Havbredey (UK), Fukushima (Japan), Utsira Nord (Norway), Gulf of Maine (US), Sud de la Bretagne II (France), Sorlige Nordsjo II (Norway). Each of these sites is summarized in the main report while more details about the studies and analyses behind the datasets are provided in the appendix. For seabed conditions, general information about the geotechnical parameters is provided and a baseline is established for the geotechnical parameters and stratigraphy that may be encountered on the sites. A set of six 'synthetic cases' is defined as building blocks providing the different parameters required for design under each case/soil condition. For the coastal infrastructure, general information about the main requirements is provided that a port should comply with to provide a satisfactory service during the construction of floating offshore wind arrays. Minimum port infrastructural requirements are provided for three types of ports.

17 WIND ENERGY↗

Transportation Hub Infrastructure Expansion: Decision Support Under Uncertainty

The Athena project (www.athena-mobility.org) has worked to investigate the relationship between the Dallas-Fort Worth Airport (DFW) and the greater Dallas area in order to better understand and therefore better inform future decision-making regarding the critical infrastructure that influence mobility between the airport and the city. Through this work, infrastructure related to curbside pickup and drop-off, parking, public transit, and the road network congestion were identified as critical to the operation of the DFW transportation hub. The infrastructure analysis and expansion aspect of the Athena project is focused on the restructuring of the CTA curb as a hierarchical curb and the building or repurposing of parking infrastructure as the interplay between these two areas. Many sources of uncertainty exist that may impact future airport and transportation hub operations, such as passenger volume growth, population demographic changes over time, electric vehicle (EV) adoption rates, and autonomous vehicle (AV) adoption rates. Due to these sources of uncertainty, we have selected for our research a modeling framework that can capture various types of uncertainty and hedge against those uncertainties in the optimization process. We analyze road network and curb congestion, the rise of transportation networking companies, trends in parking usage, existing policies around this infrastructure, airport revenue streams, and other contributing factors to enable infrastructure decision making with less uncertainty. To accomplish this wholistic analysis, we have developed a novel multi-stage, multi-period stochastic optimization model which considers the airport's decisions from 2025-2045 under different possible future macro trajectories and day-to-day variations in operational conditions captured as "annual representation of operations" scenarios with respective probabilities. This model has also been designed to leverage the outputs of various efforts under the Athena project to create a combined decision framework for infrastructure decisions. These various efforts include the route optimization model, the ASPIRES simulation, the mode choice model, and the SUMO traffic simulation. Our computational experiments of this system at scale have resulted in a working version of our infrastructure model which enables the explicit representation and consideration of various sources of uncertainty in the decision process to enable robust, flexible decision-making. This model has been effectively run on NREL's HPC system, Eagle, with large numbers of stochastic scenarios and shows promise as a scalable tool for robust consideration of uncertainties in airport planning. We have tested our model using 30,240 operational circumstances in total, resulting in a problem with more 200 million variables. This model was solved in several different configurations, and a workflow to simulate the performance of the infrastructure model results was developed and deployed. In general, our results indicate that a combination of remote parking, remote curb infrastructure, and dynamic pricing can generate revenue, reduce emissions, accommodate emerging technologies such as AVs and EVs, and manage airport passenger growth over time. We note the success of the proposed strategy depends on the data collection and forecasting abilities of DFW. We have also seen that the AV adoption by TNCs might necessitate larger amounts of remote curb. The results of this work inform strategies for airport infrastructure decision making, as well as demonstrate the value of an adaptable model, but also indicate that there are avenues remaining where further research would be of value.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comprehensive Total Cost of Ownership Quantification for Vehicles with Different Size Classes and Powertrains

In order to accurately compare the costs of two vehicles, the total cost of ownership (TCO) should consist of all costs related to both purchasing and operating the vehicle. This TCO analysis builds on previous work to provide a comprehensive perspective of all relevant vehicle costs of ownership. In this report, we present what we believe to be the most comprehensive explicit financial analysis of the costs that will be incurred by a vehicle owner. This study considers vehicle cost and depreciation, financing, fuel costs, insurance costs, maintenance and repair costs, taxes and fees, and other operational costs to formulate a holistic total cost of ownership and operation of multiple different vehicles. For each of these cost parameters that together constitute a comprehensive TCO, extensive literature review and data analysis were performed to find representative values in order to build a holistic TCO for vehicles of all size classes. The light- and heavy-duty vehicles selected for analysis in this report are representative of those that are on the road today and expected to be available in the future. Important additive analyses in this study include systematic analysis of vehicle depreciation, in-depth examination of insurance premium costs, comprehensive maintenance and repair estimates, analysis of all relevant taxes and fees, and considerations of specific costs applicable to commercial vehicles. We find that cars depreciate faster than light trucks and that older plug-in electric vehicles have a greater depreciation rate than newer electric vehicles. Light-duty vehicle (LDV) insurance costs show comparable costs for different powertrains, and lower costs for larger size classes. Medium- and heavy-duty vehicle (MHDV) insurance costs vary significantly by vocation. Electric and electrified powertrains have lower maintenance and repair costs than internal combustion engine (ICE) powertrains for all vehicle sizes, relative to vehicle price. MHDV maintenance and repair costs depend heavily on vocation and duty cycle. LDV taxes and fees are comparable across powertrain types and size classes, though marginally higher registration fees exist for alternative fuel vehicles. MHDV fees depend on the vocation, weight rating, and state. Many electric tractor trailers would be affected by additional battery weight, reducing the available payload capacity, and this cost can be substantial. Electric vehicle charging for commercial vehicles can be time-consuming; labor rates can cause this cost to dominate TCO. With improved knowledge of each of the cost components, we calculate a lifetime TCO for comparison across vehicles of different types and attributes. For a simulated small sport utility vehicle in 2025, modeled using Autonomie, the hybrid electric vehicle (HEV) has the lowest cost, followed by the conventional ICE vehicle. For MHDV, TCO can be drastically different depending on the vocation. Long-haul vehicles typically have the lowest per-mile costs. Excluding labor costs, the class 4 delivery has a comparable TCO to the day cab. Vocational trucks, refuse trucks, and transit buses have a high per-mile cost of ownership due to maintenance and insurance. For all of these vehicles, the cost of operating the vehicle is heavily weighted by the labor of the driver, followed by the fuel costs. While the HEV begins as the lowest cost powertrain for passenger vehicles, fuel cells are forecast to reach cost parity by 2030 when hydrogen prices reach $\$ 5$/kg while battery electric vehicles (BEV) reach cost parity by 2035 at a battery cost of $\$ 98$ per usable kWh of capacity, with these two technologies being the lowest cost in 2050. For the class 8 day cab tractor, the HEV and ICE vehicle begin as the lowest cost powertrains, and the 250-mile BEV reduces in cost from the most expensive to the least expensive by 2030.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DEEPEN 3D PFA Favorability Models and 2D Favorability Maps at Newberry Volcano

DEEPEN stands for DE-risking Exploration of geothermal Plays in magmatic ENvironments. Part of the DEEPEN project involved developing and testing a methodology for a 3D play fairway analysis (PFA) for multiple play types (conventional hydrothermal, superhot EGS, and supercritical). This was tested using new and existing geoscientific exploration datasets at Newberry Volcano. This GDR submission includes images, data, and models related to the 3D favorability and uncertainty models and the 2D favorability and uncertainty maps. The DEEPEN PFA Methodology is based on the method proposed by Poux et al. (2020), which uses the Leapfrog Geothermal software with the Edge extension to conduct PFA in 3D. This method uses all available data to build a 3D geodata model which can be broken down into smaller blocks and analyzed with advanced geostatistical methods. Each data set is imported into a 3D model in Leapfrog and divided into smaller blocks. Conditional queries can then be used to assign each block an index value which conditionally ranks each block's favorability, from 0-5 with 5 being most favorable, for each model (e.g., lithologic, seismic, magnetic, structural). The values between 0-5 assigned to each block are referred to as index values. The final step of the process is to combine all the index models to create a favorability index. This involves multiplying each index model by a given weight and then summing the resulting values. The DEEPEN PFA Methodology follows this approach, but split up by the specific geologic components of each play type. These components are defined as follows for each magmatic play type: 1. Conventional hydrothermal plays in magmatic environments: Heat, fluid, and permeability 2. Superhot EGS plays: Heat, thermal insulation, and producibility (the ability to create and sustain fractures suitable for and EGS reservoir) 3. Supercritical plays: Heat, supercritical fluid, pressure seal, and producibility (the proper permeability and pressure conditions to allow production of supercritical fluid) More information on these components and their development can be found in Kolker et al., 2022. For the purposes of subsurface imaging, it is easier to detect a permeable fluid-filled reservoir than it is to detect separate fluid and permeability components. Therefore, in this analysis, we combine fluid and permeability for conventional hydrothermal plays, and supercritical fluid and producibility for supercritical plays. More information on this process is described in the following sections. We also project the 3D favorability volumes onto 2D surfaces for simplified joint interpretation, and we incorporate an uncertainty component. Uncertainty was modeled using the best approach for the dataset in question, for the datasets where we had enough information to do so. Identifying which subsurface parameters are the least resolved can help qualify current PFA results and focus future efforts in data collection. Where possible, the resulting uncertainty models/indices were weighted using the same weights applied to the respective datasets, and summed, following the PFA methodology above, but for uncertainty. There are two different versions of the Leapfrog model and associated favorability models: - v1.0: The first release in June 2023 - v2.1: The second release, with improvements made to the earthquake catalog (included additional identified events, removed duplicate events), to the temperature model (fixed a deep BHT), and to the index models (updated the seismicity-heat source index models for supercritical and EGS, and the resistivity-insulation index models for all three play types). Also uses the jet color map rather than the magma color map for improved interpretability. - v2.1.1: Updated to include v2.0 uncertainty results (see below for uncertainty model versions) There are two different versions of the associated uncertainty models: - v1.0: The first release in June 2023 - v2.0: The se...

15 GEOTHERMAL ENERGY↗

Cosmological constraints from a joint DESI DR1 Full-Shape and DR2 BAO

We present a cosmological analysis combining full-shape (FS) clustering measurements from the Dark Energy Spectroscopic Instrument (DESI) DR1 with baryon acoustic oscillation (BAO) measurements from DESI DR2. To achieve a robust combination that accounts for the correlation between the two data releases, we employ the ShapeFit compression method and estimate the joint covariance using EZmocks. This compressed approach inherently mitigates the prior volume effects that have previously dominated Bayesian constraints from DESI data with minimal external priors. Consequently, we obtain — for the first time within a Bayesian framework — reliable DESI-only constraints on extensions to ΛCDM using only a Big Bang Nucleosynthesis prior on the baryon density and a wide prior on the spectral index. In flat ΛCDM, we find Ω m = 0.3035 ± 0.0085, h = 0.6876 ± 0.0059, and σ 8 = 0.822 ± 0.034. For the w 0 w a CDM dynamical dark energy model, we measure w 0 = -0.49 ± 0.25 and w a = -1.52 ± 0.77, improving constraints by ∼ 30% relative to the analogous DR1 measurement and reducing the discrepancy with ΛCDM to 1.4σ when compared to BAO only analyses. We also report competitive limits on the sum of neutrino masses and spatial curvature. This work demonstrates that the ShapeFit compression provides a prior-robust and computationally efficient pathway to constrain beyond-ΛCDM physics with large-scale structure.

baryon acoustic oscillations↗

Modelling the impact of quasar redshift errors on the full-shape analysis of correlations in the Lyman-α forest.

In preparation for the first cosmological measurements from the full shape of the Lyman-α (Lyα) forest from DESI, we must carefully model all relevant systematics that might bias our analysis. It was shown in Youles et al. (2022) that random quasar redshift errors produce a smoothing effect on the mean quasar continuum in the Lyα forest region. This, in turn, gives rise to spurious features in the Lyα autocorrelation and its cross-correlation with quasars. Using synthetic data sets based on the DESI survey, we confirm that the impact on BAO measurements is small, but that a bias is introduced to parameters which depend on the full shape of our correlations. We combine a model of this contamination in the cross-correlation (Youles et al. 2022) with a new model we introduce here for the auto-correlation. These are parametrised by 3 parameters, which, when included in a joint fit to both correlation functions, successfully eliminate any impact of redshift errors on our full-shape constraints. We also present a strategy for removing this contamination from real data, by removing ∼0.3% of correlating pairs.

cosmology↗

Constraining primordial non-Gaussianity from DESI DR1 quasars and Planck PR4 CMB lensing

We present the first measurement of local-type primordial non-Gaussianity from the cross-correlation between 1.2 million spectroscopically confirmed quasars from the first data release (DR1) of the Dark Energy Spectroscopic Instrument (DESI) and the Planck PR4 CMB lensing reconstructions. The analysis is performed in three tomographic redshift bins covering 0.8 < z < 3.5, covering a sky fraction of ∼20%. We adopt a catalog-based pseudo-C ℓ estimator and apply linear imaging weights validated on noiseless mocks. Compared to previous analyses using photometric quasar samples, our results benefit from the high purity of the DESI spectroscopic sample, the reduced noise of PR4 lensing, and the absence of excess large-scale power in the spectroscopic quasar auto-correlation. Fitting simultaneously for the non-Gaussianity parameter f NL and the linear bias amplitude in each redshift bin, we obtain f NL = 2 +28 -34 for a response parameter p = 1.6, and f NL = 6 +20 -24 for p = 1.0. These results improve the constraints on f NL by ∼35% compared to the previous analysis based on the Legacy Imaging Survey DR9. Additionally, we derive an optimal weighting scheme to maximize the constraining power. In this case, and assuming p = 1.6, we obtain f NL = 19 +25 -31 . Our results demonstrate the statistical power of DESI quasars for probing inflationary physics, and highlight the promise of future DESI data releases.

cosmological parameters from CMBR↗

Geothermal Play-Fairway Analysis of Washington State Prospects: Final Report

The Washington State Geothermal Play-Fairway Analysis overcomes the exploration challenges posed by dense vegetation, glacial deposits, and extreme precipitation. The geothermal play-fairways we target are locations where heat, permeability, and saturated porosity are present in sufficient volume to provide adequate heat exchange at depths accessible by modern drilling technology. The three study areas lie along the Cascade Range magmatic arc and are near Mount Baker, Mount St. Helens, and the Wind River Valley. The seven-year project is divided into three phases. In Phase 1 we build on a previous statewide assessment of geothermal resources and develop an initial modeling approach. The results are a series of favorability, uncertainty, and risk maps for three targeted study areas. Based on these initial results, we collect new geologic and geophysical data to further refine our modeling and reduce exploration uncertainty in Phase 2. We improve the modeling method to handle the new data and update the favorability, uncertainty, and risk maps. We also update the conceptual geothermal resource models. In Phase 3 we validate our modeling approach by drilling two temperature-gradient holes and collecting and analyzing core, image logs, and new geochemistry. Our modeling approach improves on an earlier statewide method through a more-rigorous and detailed assessment of heat and permeability. Permeability potential is assessed through geomechanical modeling of the deformation that can generate and maintain reservoir porosity and permeability. Metrics to inform heat potential include temperature-gradient wells, which are sparse in Washington; proximity of Quaternary volcanic vents and young intrusive rock; spring temperature; and reservoir temperature inferred from geothermometry. We weight the individual components using an expert-guided approach known as the Analytical Hierarchy Process. During Phase 2 we also develop a fluid-filled fracture model, and an infrastructure model that helps to delineate areas which are more favorable for geothermal development based on proximity to transmission lines, elevation, land ownership and use restrictions, and availability of process water. New geologic and geophysical data is collected during Phase 2 in each of our three main study areas. At Mount Baker and north of Mount St. Helens we conduct 1:24,000-scale geologic mapping and lidar analysis to better constrain the location and character of surface faults; detailed mapping in the Wind River Valley was completed just prior to the start of this project. Ages of intrusive rocks are determined with 40 Ar/ 39 Ar geochronology, though all of our samples are Miocene or older. We collect ground based gravity observations (a total of 1,580 new stations) in all of our study areas and ground-based magnetic lines (a total of 93 km) at Mount Baker. These data are combined with existing gravity and aeromagnetic data and used to constrain fault locations and geometry. Two to three cross sections are constructed at each study area using the mapped surface geology and forward-modeling of the gravity and magnetic data; these cross sections form the basis for our updated conceptual models. We collect magnetotelluric surveys at Mount Baker and Mount St. Helens and these data are inverted to form a resistivity model from the surface to about 10 km depth; each model shows conductive zones that can be interpreted as upwelling geothermal fluids. At Mount St. Helens we deploy a passive seismic array and use the newly detected events to refine the location of the Saint Helens seismic zone. We also employ ambient-noise tomography to develop a detailed seismic-velocity model for the study area and use this model to help constrain our cross sections and conceptual model. Based on the new data collected during Phase 2—and our updated models—we develop a campaign of temperature-gradient holes and core analysis to validate our modeling in Phase 3. Drill hole MB76-31 is located near Little Park Creek, 11 km west-southwest of the summit of Mount Baker, and is 1,471 ft deep. About 410 ft of core from the lower portion of the hole—and image logs from ~175 ft below ground surface to the bottom—are collected and analyzed. Water samples are collected and processed for geothermometry. Drill hole MSH17-24 is located along upper Schultz Creek, 16 km north-northeast of Mount St. Helens and has core from 470 ft to the bottom at 1,053 ft. We did not collect image logs due to borehole stability concerns, but water samples are collected and analyzed for geothermometry. Repeat temperature-gradient measurements are made at both sites and thermal conductivity is measured from core samples. At MB76-31, the equilibrated temperature gradient of 64°C/km and calculated heat flow of 141–159 mW/m 2 is more than twice the regional average. Detailed mapping and analysis of the core, coupled with correlation to the image logs, indicates a history of permeability generation consistent with our predictions of high permeability. Because the site has high favorability in the Phase 2 model, we consider the results a positive validation of the modeling. At site MSH17-24, the equilibrated temperature gradient of ~15°C/km and calculated heat flow of 41–43 mW/m 2 are similar to regional. Geochemical analysis of the water samples indicates a meteoric source without any geothermal component. Detailed outcrop-based mapping of fault exposures near the drill site and analysis of image logs from nearby boreholes indicates a history of permeability generation consistent with our predictions. Because the site has low favorability in the Phase 2 model, we consider the results a positive validation of the modeling. Together, the two sites provide a reasonably positive validation of the Phase 2 modeling and should encourage future use of this modeling approach.

15 GEOTHERMAL ENERGY↗

Frequentist cosmological constraints from full-shape clustering measurements in DESI DR1

We present a frequentist analysis of clustering measurements from Data Release 1 of the Dark Energy Spectroscopic Instrument (DESI) using the standard profile likelihood method. While Bayesian inferences for effective field theory models of galaxy clustering can be highly sensitive to prior choices for extended cosmological models, frequentist inferences are not susceptible to such effects. We compare frequentist and Bayesian constraints for the parameter set {σ 8 , H 0 , Ω m , w 0 , w a } using the full-shape power spectrum multipoles, post-reconstruction baryon acoustic oscillation (BAO) measurements, and external datasets from the CMB and type Ia supernovae measurements. The frequentist confidence intervals are significantly shifted relative to the Bayesian credible intervals for the w 0 w a CDM model, unless supernovae data are included. When DESI full-shape and BAO data are fit jointly, we obtain the following 1σ frequentist confidence intervals for ΛCDM (w 0 w a CDM): σ 8 = 0.863 +0.048 -0.040 , H 0 = 68.96 +0.81 -0.80 km s -1 Mpc -1 , Ω m = 0.3034 ± 0.0110 (σ 8 = 0.782 +0.060 -0.036 , H 0 = 63.7 +4.2 -2.0 km s -1 Mpc -1 , Ω m = 0.378 +0.024 -0.047 , w 0 = -0.16 +0.10 -0.50 , w a = -3.0 +1.7 ), corresponding to 0.8σ, 0.3σ, 0.7σ (2.1σ, 4.1σ, 6.5σ, 6.3σ, 6.6σ) shifts between the maximum likelihood estimate and the Bayesian posterior mean for ΛCDM (w 0 w a CDM) respectively.

Bayesian reasoning↗

DESI DR2 Galaxy luminosity functions

We present galaxy luminosity functions (LFs) for the Dark Energy Spectroscopic Instrument (DESI) DR2 Bright Galaxy Survey (BGS) in the g, r, z, and $w1$ bands over $0.002\lt z\lt 0.6$. Our analysis uses updated k-corrections and evolutionary corrections, including new polynomial kcorrection fits derived from BGS Year 1 data that supersede earlier GAMA-based prescriptions. Exploiting the statistical power of DESI, we measure LFs to very faint magnitudes, reaching $^{0.1}M_r-5\log h\sim -10$. Independent measurements from the North and South survey regions show excellent agreement around the LF knee, but the very small statistical uncertainties reveal that simple analytic forms fail to capture the full LF shape. The bright end departs from a pure exponential decline, while the faint end exhibits complex, non-powerlaw behaviour, including a pronounced upturn at $^{0.1}M_r-5\log h\gtrsim -15$, which is stronger for red galaxies than for blue. We show that our LFs are largely complete for galaxies with surface brightness $\mu _{50}\lt 25$, and that an apparent steepening fainter than $-13$ is driven primarily by local overdensity and fragmentation of large galaxies. A systematic North–South offset at the brightest magnitudes is traced to red galaxies and may reflect shallower North photometry underestimating extended earlytype profiles, although this remains inconclusive. We therefore also provide LFs based on model Petrosian magnitudes. Redshift splitting reveals small but significant residuals, indicating limitations of a simple global evolutionary model. Using the redshift limits of J. Loveday et al. (2012), we find excellent agreement with GAMA, with substantially reduced statistical errors. These measurements provide a precise reference for studies of environmental and population-dependent LFs and for testing galaxy formation models.

79 ASTRONOMY AND ASTROPHYSICS↗

Full-polarization millimeter wavelength variability of Sagittarius A * during the 2018 EHT campaign

Context. Sagittarius A* (Sgr A*), the supermassive black hole at the center of the Milky Way, provides a unique laboratory to study accretion dynamics and plasma processes near the event horizon. Aims. We investigated the variability and polarization properties of Sgr A* using ALMA observations during the 2018 Event Horizon Telescope campaign. Methods. We analyzed high-cadence full-polarization light curves from ALMA at millimeter wavelengths, performed time-series analysis, and investigated the temporal behavior during an X-ray flare observed by Chandra on 2018 April 24. The variability characteristics are compared with expectations from standard accretion flow models. Results. We find low variability in total intensity (σ/μ < 10%), but significantly higher variability in linear and circular polarization (∼30% and ∼50%, respectively). A time-series analysis reveals red-noise variability, with power spectral densities between −2 and −3 across all Stokes parameters. Polarized intensity shows stable intra-day timescales, while total intensity exhibits more variable timescales, suggesting distinct emission regions, with polarization likely arising from a coherent structure. On April 24, a statistically significant inter-band delay in polarized intensity coincides with a near-simultaneous X-ray and millimeter peak that deviates from the typical delayed flare scenario. This event also features enhanced millimeter variability and coherent polarization loop evolution. The observed simultaneity challenges standard models of transient synchrotron emission with cooling delays, favoring instead a scenario of continuous energy injection in an optically thin region. Conclusions. Our results offer new constraints on the physical mechanisms driving variability in Sgr A*, and provide key observational input for refining theoretical models of accretion and plasma behavior in the vicinity of supermassive black holes.

Galaxy: center↗

First Results on the Search for Lepton Number Violating Neutrinoless Double-𝛽 Decay with the LEGEND-200 Experiment

The LEGEND Collaboration is searching for neutrinoless double-beta (0⁢𝜈⁢𝛽⁢𝛽) decay by operating high-purity germanium detectors enriched in 76 Ge in a low-background liquid argon environment. Building on key technological innovations from the GERmanium Detector Array (GERDA) experiment and the MAJORANA DEMONSTRATOR experiment, LEGEND-200 has performed a first 0⁢𝜈⁢𝛽⁢𝛽 decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of 0.5$^{+0.3}_{−0.2}$ ⁢cts/(keV ton yr) in the 0⁢𝜈⁢𝛽⁢𝛽 decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of 2.8 ×10 26 yr on the half-life of 0⁢𝜈⁢𝛽⁢𝛽 decay, reveals no evidence for a signal and sets a new observed lower limit at 𝑇$^{⁢0𝜈}_{1/2}$ > 1.9 × 10 26 yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range 𝑚 𝛽⁢𝛽 < 75–200 meV, depending on the adopted nuclear matrix element.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗