Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “binary signals”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

689 records · Page 39

Model Validation of Phase-Induced Amplitude Apodization Complex Mask Coronagraph for LUVOIR-A in Vacuum

The Phase-Induced Amplitude Apodization Complex Mask Coronagraph (PIAACMC) is a coronagraph architecture for the next generation of large space telescopes optimized for habitable exoplanet imaging that can achieve attractive theoretical performance with high throughput at small inner working angles (IWA). PIAACMC designs are compatible with large, on-axis, segmented apertures such as the Large UV / Optical/ Infrared A (LUVOIR-A) concept currently being considered by the decadal survey review which would greatly enhance the possibility to achieve statistically significant scientific yields and signal quality for direct imaging exoplanet surveys. PIAACMC has been recently implemented for LUVOIR-A and is currently being tested in vacuum at JPL’s High-Contrast Imaging Testbed (HCIT). In this work, we review the theoretical performance of the PIAACMC instrument designed to meet a 1e-9 raw contrast goal in 10% broadband light in a region from 2-8 L/D both before and after the wavefront control loop. We use empirical measurements from the vacuum testbed to verify the instrument model and its performance including line-of-sight errors, instrument alignment, and fabricated components. In particular, the model verification includes measured sags of the manufactured PIAA mirrors by NuTek. The CMC mask was manufactured at JPL’s Microdevices Laboratory and we include surface profile characterization measurement. We assess the impact on performance of the different manufacturing and alignment errors.

High-Contrast Imaging↗

Robust Strategy for Rocket Engine Health Monitoring

Monitoring the health of rocket engine systems is essentially a two-phase process. The acquisition phase involves sensing physical conditions at selected locations, converting physical inputs to electrical signals, conditioning the signals as appropriate to establish scale or filter interference, and recording results in a form that is easy to interpret. The inference phase involves analysis of results from the acquisition phase, comparison of analysis results to established health measures, and assessment of health indications. A variety of analytical tools may be employed in the inference phase of health monitoring. These tools can be separated into three broad categories: statistical, rule based, and model based. Statistical methods can provide excellent comparative measures of engine operating health. They require well-characterized data from an ensemble of "typical" engines, or "golden" data from a specific test assumed to define the operating norm in order to establish reliable comparative measures. Statistical methods are generally suitable for real-time health monitoring because they do not deal with the physical complexities of engine operation. The utility of statistical methods in rocket engine health monitoring is hindered by practical limits on the quantity and quality of available data. This is due to the difficulty and high cost of data acquisition, the limited number of available test engines, and the problem of simulating flight conditions in ground test facilities. In addition, statistical methods incur a penalty for disregarding flow complexity and are therefore limited in their ability to define performance shift causality. Rule based methods infer the health state of the engine system based on comparison of individual measurements or combinations of measurements with defined health norms or rules. This does not mean that rule based methods are necessarily simple. Although binary yes-no health assessment can sometimes be established by relatively simple rules, the causality assignment needed for refined health monitoring often requires an exceptionally complex rule base involving complicated logical maps. Structuring the rule system to be clear and unambiguous can be difficult, and the expert input required to maintain a large logic network and associated rule base can be prohibitive.

Santi, L. Michael↗

J-GEM optical and near-infrared follow-up of gravitational wave events during LIGO’s and Virgo’s third observing run

The Laser Interferometer Gravitational-wave Observatory Scientific Collaboration and Virgo Collaboration (LVC) sent out 56 gravitational-wave (GW) notices during the third observing run (O3). The Japanese Collaboration for Gravitational wave ElectroMagnetic follow-up (J-GEM) performed optical and near-infrared observations to identify and observe an electromagnetic (EM) counterpart. We constructed a web-based system that enabled us to obtain and share information on candidate host galaxies for the counterpart, and the status of our observations. Candidate host galaxies were selected from the GLADE catalog with a weight based on the 3D GW localization map provided by LVC. We conducted galaxy-targeted and wide-field blind surveys, real-time data analysis, and visual inspection of observed galaxies. We performed galaxy-targeted follow-ups to 23 GW events during O3, and the maximum probability covered by our observations reached 9.8%. Among these, we successfully started observations for 10 GW events within 0.5 days after the detection. This result demonstrates that our follow-up observation has the potential to constrain EM radiation models for a merger of binary neutron stars at a distance of up to ~100 Mpc with a probability area of ≤ 500 deg 2 .

79 ASTRONOMY AND ASTROPHYSICS↗

Follow-up and Validation of K2 and TESS Planetary Systems with Keck NIRC2 Adaptive Optics Imaging

High resolution imaging (HRI) is a critical part of the transiting exoplanet follow-up and validation process. HRI allows previously unresolved stellar companions and background blends to be resolved, vetting false positive signals and improving the radii measurements of true planets. Through a multi-semester Keck NIRC2 adaptive optics imaging program, we have pursued HRI of K2 and TESS candidate planet host systems to provide the transiting exoplanet community with necessary data for system validation and characterization. Here we present a summary of our ongoing program that includes an up to date list of targets observed, a description of the observations and data reduction, and a discussion of planetary systems validated by the community using these data. This observing program has been key in NASA’s K2 and TESS missions reaching their goals of identifying new exoplanets ideal for continued follow-up observations to measure their masses and investigate their atmospheres. All observations presented here are available as calibrated images and resulting contrast curves through the Exoplanet Follow-up Observing Program (ExoFOP) website. We encourage members of the exoplanet community to use these data products in their ongoing planetary system validation and characterization efforts.

Adaptive optics↗

SN 1993J: A Type IIb supernova

The evolution of the bright Type II supernova discovered last year in M81, SN 1993J, is consistent with that expected for the explosion of a star which on the main sequence had a mass of 13-16 Solar Mass but which, owing to mass exchange with a binary companion (a intially approximately 3-5 AU, depending upon the actual presupernova radius and the masses of the two stars) lost almost all of its hydrogen-rich envelope during late helium burning. At the time of explosion, the helium core mass was 4.0 +/- 0.5 Solar Mass and the hydrogen envelope, 0.20 +/- 0.05 Solar Mass. The envelope was helium and nitrogen-rich (carbon-deficient) and the radius of the star, 4 +/- 1 x 10(exp 13) cm. The luminosity of the presupernova star was 3 + 1 x 10(exp 38) ergs/s, with the companion star contributing an additional approximately 10(exp 38) ergs/s. The star may have been a pulsating variable at the time of the explosion. For an explosion energy near 10(exp 51) ergs (KE at infinity) and an assumed distance of 3.3 Mpc, a mass of Ni-56 in the range 0.07 +/- 0.01 Solar Mass was produced and ejected. This presciption gives a light curve which compares favorably with the bolomatric observations. Color photometry is more restrictive and requires a model in which the hydrogen-envelope mass is low and the mixing of hydrogen inward has been small, but in which appreciable Ni-56 has been mixed outward into the helium and heavy-element core. It is possible to obtain good agreement with B and V light curves during the first 50 days, but later photometry, especially in bands other than B and V, will require a non-local thermo-dynamic equilibrium (LTE) spectral calculation for comparison. Based upon our model, we predict a flux of approximately 10(exp -5)(3.3 Mpc/D)(exp 2) photons/sq cm/s in the 847 keV line of CO-56 at peak during 1993 August. It may be easier to detect the Computonized continuum which peaks at a few times 10(exp -4) photons /s/sq cm/MeV at 40 keV a few months after the explosion (though neither of these signals were, or should have been, detected by the Compton Gamma-Ray observatory (CGRO). The presupernova star was filing its Roche lobe at the time of the explosion and thus its envelope was highly deformed (about 3:2). The companion star is presently embedded in the supernova, but should becopme visable at age 3 yr (perhaps earlier in the ultraviolet) when the supernova has faded below 10(exp 38) ergs/s. Indeed, if 'kicks' have not played an important role, it is still bound to the neutron star.

Woosley, S. E.↗