Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “arterial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Determination of oxygen tension in the subcutaneous tissue of cosmonauts during the Salyut-6 mission

A polarographic technique was used to measure the oxygen tension in subcutaneous tissue of the forearm of a cosmonaut prior to, after, and on the fourth day of a space mission performed by Salut-6. A drop in the oxygen exchange rate in the peripheral tissues during weightlessness was observed. The mechanisms of this change are studied, taking into consideration the blood distribution in the organism and microcirculation disorders reflected by a decreased blood flow rate in arterial-venous junctions.

Baranski, S.↗

Some potential blood flow experiments for space

Blood is a colloidal suspension of cells, predominantly erythrocytes, (red cells) in an aqueous solution called plasma. Because the red cells are more dense than the plasma, and because they tend to aggregate, erythrocyte sedimentation can be significant when the shear stresses in flowing blood are small. This behavior, coupled with equipment restrictions, has prevented certain definitive fluid mechanical studies from being performed with blood in ground-based experiments. Among such experiments, which could be satisfactorily performed in a microgravity environment, are the following: (1) studies of blood flow in small tubes, to obtain pressure-flow rate relationships, to determine if increased red cell aggregation can be an aid to blood circulation, and to determine vessel entrance lengths, and (2) studies of blood flow through vessel junctions (bifurcations), to obtain information on cell distribution in downstream vessels of (arterial) bifurcations, and to test flow models of stratified convergent blood flows downstream from (venous) bifurcations.

Cokelet, G. R.↗

Modulation of human sinus node function by systemic hypoxia

The present study was conducted to determine whether bradycardia develops during systemic hypoxia in supine conscious human volunteers when respiratory frequency and tidal volume are maintained at constant levels. The obtained results suggest that mild hypoxia provokes cardioacceleration in humans, independent of changes of ventilation or baroreflex responsiveness. The earliest cardioacceleration is more prominent in the inspiratory than in the expiratory phase of respiration, and occurs with very small reductions of arterial oxygen saturation. Moderate systemic hypoxia dampens fluctuations of heart rate during the respiratory cycle.

Eckberg, D. L.↗

Investigation of the combined effects of bedrest and mild hypoxia

Subjects were exposed to an 8-h mild hypoxia exposure (8000 ft. equivalent, 2438 m) with and without a 28-h period of 6 deg headdown bedrest. Anticipated responses to the bedrest and the hypoxia were observed. There was no indication that bedrest affected the arterial oxygenation or the oxygen gradient across the lungs of the subjects undergoing mild hypoxia. It is concluded that there is no evidence that would preclude an alveolar O2 pressure as low as 69 torr during contingency spacecraft operation.

Waligora, J. M.↗

Effects of horizontal body casting on the baroreceptor reflex control of heart rate

The purpose of this study was to investigate the effects of long-term horizontal body position on baroreceptor reflex control of heart rate. Six male rhesus monkeys (6.2-9.4 kg) were given bolus injections of 4.0 microgram/kg, phenylephrine during each of the following conditions: awake, anesthetized (10 mg/kg ketamine HCl), and after beta-blockade (1 mg/kg propranolol HCl) before, 7, 14, and 28 days after being placed in a horizontal body cast. R-R interval vs. systolic arterial pressure was plotted, and the slope was determined by least-squares-fit linear regression. Baroreceptor slope was significantly reduced by 7 days of horizontal body position and remained attenuated throughout the 28-day restraint period both before and after beta-receptor blockade. These data are consistent with the thesis that prolonged exposure to a zero-gravity environment impairs autonomic reflex regulation of the cardiovascular system.

Billman, G. E.↗

Antiorthostatic hypokinesia and circulation in the rat

Circulatory mechanisms that occur during exposure to head-down hypokinesia as well as during readaptation to control conditions were studied on unanesthetized unrestrained Sprague-Dawley rats exposed to hypokinesia for seven days. The heart rate was slightly elevated, and the right atrial pressure increased to 4 mm Hg, but returned to 0 mm Hg after three days of exposure. Mean arterial blood pressure decreased from 118 to 100 mm Hg during early exposure to antiorthostatic hypokinesia. Cardiac output and stroke volume of resting rats increased during early exposure to hypokinesia but decreased continuously during the next seven days. The results indicate that antiorthostatic hypokinesia induces circulatory changes similar to those seen in astronauts after several days of exposure to 0 g forces.

Popovic, V.↗

Long Heat Pipe Transports 2.6 kW

High-capacity heat pipe employs slender artery-and-wick structure. Ribbon of stainless steel screen wrapped around copper mandrel in conical copper forming tool. Outside edge of wrapped screen welded to layer on which it rests. Long heat pipe transports thermal energy at rate of 2,600 watts at operating temperature of 923 K.

Ernst, D. M.↗

Study of a heat rejection system for the Nuclear Electric Propulsion (NEP) spacecraft

Two different heat pipe radiator elements, one intended for use with the power conversion subsystem of the NASA funded nuclear electric propulsion (NEP) spacecraft, and one intended for use with the DOE funded space power advanced reactor (SPAR) system were tested and evaluated. The NEP stainless steel/sodium heat pipe was 4.42 meters long and had a 1 cm diameter. Thermal performance testing at 920 K showed a non-limited power level of 3560 watts, well in excess of the design power of 2600 watts. This test verified the applicability of screen arteries for use in long radiator heat pipes. The SPAR titanium/potassium heat pipe was 5.5 meters long and had a semicircular crossection with a 4 cm diameter. Thermal performance testing at 775 K showed a maximum power level of 1.86 kW, somewhat short of the desired 2.6 kW beginning of life design requirement. The reduced performance was shown to be the result of the inability of the evaporator wall wick (shot blasted evaporator wall) to handle the required liquid flow.

Ernest, D. M.↗

Long titanium heat pipes for high-temperature space radiators

Titanium heat pipes are being developed to provide light weight, reliable heat rejection devices as an alternate radiator design for the Space Reactor Power System (SP-100). The radiator design includes 360 heat pipes, each of which is 5.2 m long and dissipates 3 kW of power at 775 K. The radiator heat pipes use potassium as the working fluid, have two screen arteries for fluid return, a roughened surface distributive wicking system, and a D shaped cross section container configuration. A prototype titanium heat pipe, 5.5 m long, was fabricated and tested in space simulating conditions. Results from startup and isothermal operation tests are presented. These results are also compared to theoretical performance predictions that were used to design the heat pipe initially.

Girrens, S. P.↗

System and method for moving a probe to follow movements of tissue

An apparatus is described for moving a probe that engages moving living tissue such as a heart or an artery that is penetrated by the probe, which moves the probe in synchronism with the tissue to maintain the probe at a constant location with respect to the tissue. The apparatus includes a servo positioner which moves a servo member to maintain a constant distance from a sensed object while applying very little force to the sensed object, and a follower having a stirrup at one end resting on a surface of the living tissue and another end carrying a sensed object adjacent to the servo member. A probe holder has one end mounted on the servo member and another end which holds the probe.

Feldstein, C.↗

The diagnostic accuracy of exercise electrocardiography - A review

The cardiovascular 'stress test', and particularly the graded treadmill exercist test, has gained wide acceptance as a diagnostic aid in searching for ischemic heart disease and as a prognostic indicator for those with known coronary artery disease. Controversies still exist, however, in its use in mass screening and in interpreting equivocal tests. A review of the use and value of electrocardiographic exercise testing is presented. Topics such as its use in asymptomatic individuals, the adjuvant use of clinical examination, and the examination of ancillary treadmill parameters are presented. No attempt is made to detail the very significant contributions of radionuclide scanning. The positive exercise electrocardiogram in the asymptomatic subject is discussed and guidelines for clinical management are offered.

Johnson, R. L.↗

Long titanium heat pipes for high-temperature space radiators

Titanium heat pipes are being developed to provide light weight, reliable heat rejection devices as an alternate radiator design for the Space Reactor Power System (SP-100). The radiator design includes 360 heat pipes, each of which is 5.2 m long and dissipates 3 kW of power at 775 K. The radiator heat pipes use potassium as the working fluid, have two screen arteries for fluid return, a roughened surface distributive wicking system, and a D-shaped cross-section container configuration. A prototype titanium heat pipe, 5.5-m long, has been fabricated and tested in space-simulating conditions. Results from startup and isothermal operation tests are presented. These results are also compared to theoretical performance predictions that were used to design the heat pipe initially.

Girrens, S. P.↗

Hormonal changes in antiorthostatic rats

Hypokinesia, especially hypokinesia with negative tilt ('antiorthostatic hypokinesia'), mimics some of the effects of weightlessness. It is shown that cardiac output is increased during early exposure of rats to antiorthostatic hypokinesia. The increase of the stroke volume and of the cardiac output observed in the antiorthostatic hypokinetic rats is probably the consequence of a blood volume shift toward the chest brought forth by head-down positioning of the animals. It is also possible that struggling of the animals to escape from the harness and an increased metabolism contribute to the elevation of cardiac output. In order to study this hypothesis 'stress hormones' were measured in the antiorthostatic rats. Plasma levels of ACTH, corticosterone and prolactin were measured in the arterial blood (0.3 ml) sampled before, during and after hypokinesia from chronic aortic cannulas of the rats.

Popovic, V.↗

Fluid and electrolyte homeostasis in space - A primate model to look at mechanisms

To elucidate the physiological mechanisms involved in the cardiovascular and renal responses to spaceflight, a ground-based primate model has been developed which uses lower body positive pressure (LBPP) to simulate the chronic central vascular expansion associated with weightlessnes. Four male squirrel monkeys with chronically implanted arterial and venous catheters and the capacity for continuous urine collection were subjected to LBPP for 4 days. Onset of LBPP resulted in an immediate diuresis, natriuresis and kaliuresis and a significant fall in plasma aldosterone and potassium levels. By day 2 the level of natriuresis had decreased by half, while potassium excretion and plasma aldosterone values had returned to control levels despite the persistence of a significantly reduced plasma potassium concentration. It is concluded that the low plasma potassium level appears not to stimulate a compensatory fall in plasma aldosterone because of the simultaneous presence of body volume contraction acting to raise aldosterone levels.

Moore-Ede, M. C.↗

Metabolic alkalosis during immobilization in monkeys (M. nemestrina)

The systemic and renal acid-base response of monkeys during ten weeks of immobilization was studied. By three weeks of immobilization, arterial pH and bicarbonate concentrations were elevated (chronic metabolic alkalosis). Net urinary acid excretion increased in immobilized animals. Urinary bicarbonate excretion decreased during the first three weeks of immobilization, and then returned to control levels. Sustained increases in urinary ammonium excretion were seen throughout the time duration of immobilization. Neither potassium depletion nor hypokalemia was observed. Most parameters returned promptly to the normal range during the first week of recovery. Factors tentatively associated with changes in acid-base status of monkeys include contraction of extracellular fluid volume, retention of bicarbonate, increased acid excretion, and possible participation of extrarenal buffers.

Young, D. R.↗

Pioneering in gravitational physiology

Gravity affects biology at almost all levels above that of the cell organelle. Attention is presently given to progress made in the understanding of gravitational effects through studies employing centrifuges, clinostats, inverted preparations, linear devices, water immersion, free fall, and short- and long-term spaceflight. The cardiovascular changes which cause malaise and illness during the first few days of extended space missions are the direct result of fluid translocation from the lower extremities. Upon reentry, there is hypovolumnia and a cardiovascular deconditioning that can include tachycardia, changes in arterial blood pressure, narrow pulse pressure, and syncope. Attention is also given to NASA's gravitational physiology reseach program.

Soffen, G. A.↗

Rotary Joint for Heat Transfer

Rotary joint exchanges heat between two heat pipes - one rotating and one stationary. Joint accommodates varying heat loads with little temperature drop across interface. According to concept, heat pipe enters center of disklike stationary section of joint. There, wicks in central artery of heat pipe separate into multiple strands that lead to concentric channels on rotaryinterface side of stationary disk. Thin layer of liquid sodium/potassium alloy carries heat from one member of rotary joint to other. Liquid conducts heat efficiently while permitting relative motion between members. Polypropylene rings contain liquid without interfering with rotation.

Shauback, R.↗