Replacing Neural Networks by Optimal Analytical Predictors for the Detection of Phase Transitions
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Many complex intermetallic structures possess cagelike environments that can host additional guest atoms. In Al 10 V, these atoms give rise to low-frequency, localized vibrations (Einstein modes) that dominate the thermodynamic response at low temperature. They become imaginary under volume expansion as temperature rises, invalidating the harmonic approximation. Here, we develop a framework to incorporate these strongly anharmonic vibrational modes into first-principles thermodynamic calculations. By explicitly modeling the cage potential and solving the associated Schrödinger equation numerically, we compute the full anharmonic free energy contribution and demonstrate its impact on the thermodynamic behavior of Al 10 V. This allows us to examine structures with different cage fillings and construct the Al-V phase diagram in the relevant composition range. Our results reproduce key experimental signatures, including the anomalous rise in the thermal expansion coefficient and heat capacity at low temperatures, and reveal that the presence and the extent of cage filling by guest atoms is essential to stabilizing the Al 10 V phase at elevated temperatures.
The energy-dispersive neutron spectra transmitted through single crystals are characterized by sharp Bragg dips at specific wavelengths, where Bragg's law is being fulfilled for certain crystallographic planes. This phenomenon allows for developing methods for crystal-orientation determination techniques similar to electron backscatter diffraction and X-ray diffraction microscopy. This work presents a new procedure to recover the orientation matrix for single crystals using transmission spectra recorded during rotation of a crystal about an axis perpendicular to a polychromatic neutron beam. The proposed method consists of an initial transformation of the as-collected wavelength–rotation maps to a wavevector $\textit{K}$ space, resulting in linear pseudo-Kossel lines that are suitable for analysis and indexing using image-processing procedures. Further, simulated neutron transmission spectra through a copper crystal with known orientations were used to set and prove the numerical approach. This technique may be expanded for cases where the neutron beam intersects multiple single-crystal grains with different orientations.
With the challenges of increased grid dynamics and more variability of power generation from renewable energy sources, rapidly increasing complexity in the grid model, and abundant data from measurements and simulations, the requirements for computational analysis have also increased dramatically. Power system operators and engineers need to analyze more scenarios, extract meaningful information from a larger set of data, and respond more quickly when faced with these new challenges for large-scale applications, such as contingency analysis. This paper proposes a novel big data analysis approach for power system cascading analysis, prevention, and remediation. The developed techniques will be capable of cascading analysis, better assessment of the system’s vulnerability level, as well as proposing potential remediation. Case studies using IEEE 118-bus system and a 500-bus system, with a comparison against a commercial tool, validate the advantages of the developed big data approach: accurate prediction, and more importantly, faster and effective correction actions.The developed techniques could be further used for other power system applications.
Grid-forming storage resources are critical to the operation of power grids with high renewable penetration. Over the years, there has been considerable emphasis on understanding the benefits these inverter-based storage resources bring towards managing volatility and enhancing grid reliability but little is studied about the supplementary advantages latent in their operation. This paper investigates one such application in which we explore the impact of grid-forming distributed storage in damping low-frequency inter-area oscillations. We present a detailed analysis characterizing the impact of inverter-droop and storage size on the slower eigenvalues, highlighting potential design considerations for enhancing system stability.
Explore the source record for details and available documents.
A network of virtual machines at cloud server sites connected over virtual IO connections is a flexible, easily deployable, and cost-effective alternative to a physical network infrastructure with dedicated servers connected over leased fiber lines. We study the throughput performance of such a cloud network by collecting measurements over Google Cloud infrastructure spanning multiple continents. To study its ideal performance and impact of packet losses, we utilize its emulation using dedicated servers and connection hardware emulation devices. We compare the measurements over the cloud network to those over its emulation on a testbed. We examine the throughput profiles of both networks as a function of the round trip time and their utilization-concavity coefficients, estimated using measurements for common TCP versions. The throughput profile's concave-convex shape and its coefficient are critical indicators of the network performance, qualitatively and quantitatively, respectively. The results indicate their overall agreement between the production cloud network and its emulation using dedicated connections, and a near optimal throughput performance of the former except for a few under-performing connections. Also, the number of parallel flows is found to be a dominant factor in optimizing the throughput across various conditions and TCP versions.
Accurate and synchronized timing information is required by power system operators for controlling the grid infrastructure (relays, Phasor Measurement Units (PMUs), etc.) and determining asset positions. Satellite-based global positioning system (GPS) is the primary source of timing information. However, GPS disruptions today (both intentional and unintentional) can significantly compromise the reliability and security of our electric grids. A robust alternate source for accurate timing is critical to serve both as a deterrent against malicious attacks and as a redundant system in enhancing the resilience against extreme events that could disrupt the GPS network. To achieve this, we rely on the highly accurate, terrestrial atomic clock-based network for alternative timing and synchronization. In this paper, we discuss an experimental setup for an alternative timing approach. The data obtained from this experimental setup is continuously monitored and analyzed using various time deviation metrics. We also use these metrics to compute deviations of our clock with respect to the National Institute of Standards and Technologys (NIST) GPS data. The results obtained from these metric computations are elaborately discussed. Finally, we discuss the integration of the procedures involved, like real-time data ingestion, metric computation, and result visualization, in a novel microservices-based architecture for situational awareness.
Not Available
A magnetic charge field analysis approach is presented that models an array of magnets by using a magnetic vector Fourier series representation. Using a Fourier series function enables the magnets' relative permeability to be accounted for and also reduces the computational burden. The accuracy of the presented modelling approach is validated by studying the fields and forces created by a magnetic lead screw when acting as a magnetic spring
Not provided.
Electric utilities in California have historically been linked to up to 10% of wildfires. To mitigate this risk, Southern California Edison has invested significantly in wildfire prevention strategies, including undergrounding cables and enhancing equipment inspections. This article explores a novel approach to fire prevention by detecting anomalies in the distribution system that may indicate potential fire hazards. The focus is on identifying arcing conditions through high-resolution point-on-wave (POW) measurements. Arcing, a precursor to fires, is challenging to detect due to its subtle transients and complex system topology. The article discusses the use of advanced signal processing and machine learning techniques, such as spectral correlation function and discrete wavelet transform, to extract features from POW data and accurately identify arcing events. The study demonstrates a high accuracy rate in detecting arcing, paving the way for improved fire prevention measures in electric distribution systems.
Not Available