Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “additional protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Update of Bisphosphonate Flight Experiment

Elevated bone resorption is a hallmark of human spaceflight and bed rest indicating that elevated remodeling is a major factor in the etiology of space flight bone loss. In a collaborative effort between the NASA and JAXA space agencies, we are testing whether an antiresorptive drug would provide additional benefit to in-flight exercise to ameliorate bone loss and hypercalciuria during long-duration spaceflight. Measurements of bone loss include DXA, QCT, pQCT, urinary and blood biomarkers. We have completed analysis of R+1year data from 7 crewmembers treated with alendronate during flight, as well as immediate post flight (R+<2wks) data from 6 of 10 concurrent controls without treatment. The treated astronauts used the Advanced Resistive Exercise Device (ARED) during their missions. The purpose of this report is twofold: 1) to report the results of inflight, post flight and one year post flight bone measures compared with available controls with and without the use of ARED; and 2) to discuss preliminary data on concurrent controls. The figure below compares the BMD changes in ISS crewmembers exercising with and without the current ARED protocol and the alendronate treated crewmembers also using the ARED. This shows that the use of ARED prevents about half the bone loss seen in early ISS crewmembers and that the addition of an antiresorptive provides additional benefit. Resorption markers and urinary Ca excretion are not impacted by exercise alone but are significantly reduced with antiresorptive treatment. Bone measures for treated subjects, 1 year after return from space remain at or near baseline. DXA data for the 6 concurrent controls using the ARED device are similar to DXA data shown in the figure below. QCT data for these six indicate that the integral data are consistent with the DXA data, i.e., comparing the two control groups suggests significant but incomplete improvement in maintaining BMD using the ARED protocol. Biochemical data of the concurrent control group await sample return and analysis. The preliminary conclusion is that an antiresorptive may be an effective adjunct to exercise during long-duration spaceflight.

LeBlanc, A.↗

Interindividual variability of arterial impulse response to intravenous injection of nonionic contrast agent (Iohexol) in DCE-CT study

Purpose: It is known that the arterial input function (AIF) in dynamic contrast-enhanced (DCE)-CT differs among patients even for fixed contrast injection protocols. Therefore, a study has been performed to investigate the interindividual variability of the AIF with respect to patient factors (such as weight, height, and age). In addition, it has been demonstrated that the relations from the interindividual variability investigation can be further used for the estimation of AIF for a patient without the requirement of measurement. Methods: DCE-CT data for a cohort of 34 patients with cervical carcinoma were used for the investigation of interindividual variability of the AIF. To dissociate the effect of different durations of contrast injection, the arterial impulse response (AIR) to intravenous contrast injection was calculated and examined for its correlations with these patient factors. An empirical functional form was proposed to model the AIR with temporal intensity of a first pass of contrast agent followed by recirculation and quasiequilibrium state of contrast concentration. Specific features (onset time, peak time, and amplitudes) of the AIR were tested for correlations with the patient factors. Linear regression was applied to cases that show significant strong correlation between the AIR amplitudes and patient factors. The results were then used to predict the AIR for any given patient based on the patient factors. It was shown that using the predicted AIR, the AIF of the patient can be estimated without the requirement of measurement given the injection protocol is known. The method of AIF estimation was tested in DCE-CT data from another group of 14 patients. The efficacy of individually estimated AIF on pharmacokinetic analysis was assessed against the use of measured AIF and population-averaged AIF as the latter is another possible strategy for AIF generation if AIF measurement is not available. Results: It was found that the amplitudes of AIR postonset time were significantly correlated with patient bodyweight at most time points (r<-0.44, P<0.01) except 8-17 s (P>0.01). When the adiabatic tissue homogeneity (ATH) and the Kety models were applied to the pharmacokinetic analysis, the mean percentage errors in kinetic parameter estimates induced by using the estimated AIF instead of the measured one for both models ranged from -4.98% to 11.19%. Conclusions: It was found that there are strong linear relationships between AIR and patient weight; thereby the AIR of a patient can be estimated with patient weight. The proposed method of AIF estimation is potentially applicable in cases where AIF measurement is not possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gender Consideration in Experiment Design for Airbrake in Prebreathe

If gender is a confounder of the decompression sickness (DCS) or venous gas emboli (VGE) outcomes of a proposed air break in oxygen prebreathe (PB) project, then decisions about the final experiment design must be made. We evaluated if the incidence of DCS and VGE from tests in altitude chambers over 20 years were different between men and women after resting and exercise prebreathe protocols. Nitrogen washout during PB is our primary risk mitigation strategy to prevent subsequent DCS and VGE in subjects. Bubbles in the pulmonary artery (venous blood) were detected from the precordial position using Doppler ultrasound bubble detectors. The subjects were monitored for VGE for four min at about 15 min intervals for the duration of the altitude exposure, with maximum bubble grade assigned a Spencer Grade of IV. There was no difference in DCS incidence between men and women in either PB protocol. The incidence of VGE and Grade IV VGE is statistically lower in women compared to men after resting PB. Even when 10 tests were compared with Mantel-Haenszel 2 where both men (n = 168) and women (n = 92) appeared, the p-value for VGE incidence was still significant at 0.03. The incidence of VGE and Grade IV VGE is not statistically lower in women compared to men after exercise PB. Even when six tests were compared with Mantel-Haenszel x2 where both men (n = 165) and women (n = 49) appeared, the p-value for VGE incidence was still not significant at 0.90. Our goal is to understand the risk of brief air breaks during PB without other confounding variables invalidating our conclusions. The cost to additionally account for the confounding role of gender on VGE outcome after resting PB is judged excessive. Our decision is to only evaluate air breaks in the exercise PB protocol. So there is no restriction to recruiting women as test subjects.

Conkin, Johnny↗

Integration of Small Angle X-Ray Scattering Data Into Structural Modeling of Proteins And Their Assemblies

A major challenge in structural biology is to determine the configuration of domains and proteins in multidomain proteins and assemblies, respectively. All available data should be considered to maximize the accuracy and precision of these models. Small-angle X-ray scattering (SAXS) efficiently provides low-resolution experimental data about the shapes of proteins and their assemblies. Thus, we integrated SAXS profiles into our software for modeling proteins and their assemblies by satisfaction of spatial restraints. Specifically, we modeled the quaternary structures of multidomain proteins with structurally defined rigid domains as well as quaternary structures of binary complexes of structurally defined rigid proteins. In addition to SAXS profiles and the component structures, we used stereochemical restraints and an atomic distance-dependent statistical potential. The scoring function is optimized by a biased Monte Carlo protocol, including quasi-Newton and simulated annealing schemes. The final prediction corresponds to the best scoring solution in the largest cluster of many independently calculated solutions. To quantify how well the quaternary structures are determined based on their SAXS profiles, we used a benchmark of 12 simulated examples as well as an experimental SAXS profile of the homotetramer D-xylose isomerase. Optimization of the SAXS-dependent scoring function generally results in accurate models if sufficiently precise approximations for the constituent rigid bodies are available; otherwise, the best scoring models can have significant errors. Thus, SAXS profiles can play a useful role in the structural characterization of proteins and assemblies if they are combined with additional data and used judiciously. Our integration of a SAXS profile into modeling by satisfaction of spatial restraints will facilitate further integration of different kinds of data for structure determination of proteins and their assemblies.

59 BASIC BIOLOGICAL SCIENCES↗

An active learning framework for the rapid assessment of galvanic corrosion

The current present in a galvanic couple can define its resistance or susceptibility to corrosion. However, as the current is dependent upon environmental, material, and geometrical parameters it is experimentally costly to measure. To reduce these costs, Finite Element (FE) simulations can be used to assess the cathodic current but also require experimental inputs to define boundary conditions. Due to these challenges, it is crucial to accelerate predictions and accurately predict the current output for different environments and geometries representative of in-service conditions. Machine learned surrogate models provides a means to accelerate corrosion predictions. However, a one-time cost is incurred in procuring the simulation and experimental dataset necessary to calibrate the surrogate model. Therefore, an active learning protocol is developed through calibration of a low-cost surrogate model for the cathodic current of an exemplar galvanic couple (AA7075-SS304) as a function of environmental and geometric parameters. The surrogate model is calibrated on a dataset of FE simulations, and calculates an acquisition function that identifies specific additional inputs with the maximum potential to improve the current predictions. This is accomplished through a staggered workflow that not only improves and refines prediction, but identifies the points at which the most information is gained, thus enabling expansion to a larger parameter space. The protocols developed and demonstrated in this work provide a powerful tool for screening various forms of corrosion under in-service conditions.

36 MATERIALS SCIENCE↗

Modular Processing of Flare Gas for Carbon Nanoproducts

This project demonstrated the technical viability and economic promise of a modular system for converting flared natural gas into valuable carbon nanoproducts (CNPs) through catalytic chemical vapor deposition (CVD). All major project milestones were successfully completed, including reactor design and commissioning, catalyst development, process optimization, technoeconomic analysis, and application testing in concrete systems. The overarching goal was to create a scalable, field-deployable process that valorizes stranded methane by producing high-value carbon materials for use in cementitious composites. At the lab scale, the team designed and built a fluidized bed reactor optimized for use with silica fume-supported nickel catalysts synthesized via atomic layer deposition (ALD). A statistically designed sintering study enabled precise tuning of nickel nanoparticle size, identifying the influence of oxygen partial pressure, time, and temperature on catalyst morphology and performance. These insights allowed the team to target catalyst conditions that maximize carbon nanofilament growth. Subsequent CVD experiments achieved up to 31.8 wt% carbon deposition under optimized conditions, with TEM confirming the presence of nanofilament structures and sustained hydrogen evolution during reaction. Reactor upgrades and empirical fluidization studies supported the development of reliable, repeatable experimental protocols. The modular pilot-scale skid reactor was fully constructed, instrumented, and commissioned. Capable of operating at 675–800°C and pressures up to 290 psig, the system was designed for continuous operation at a carbon production rate of 1 kg/hr. Initial demonstration runs confirmed solids handling, thermal control, and system leak-tightness, although a critical reactor component (the downfeed tube) was inadvertently omitted during final assembly. This omission limited gas–solid contact and prevented meaningful carbon deposition during pilot-scale CVD runs. Nonetheless, the system operated safely under design conditions, and the root cause of performance limitations was clearly identified. Complementary work on UHPC formulations demonstrated that small additions of carbon nanoproducts, including those derived from flare gas, can significantly enhance mechanical performance while preserving workability. A comprehensive study of CNF dispersion techniques and mix design optimization led to a clear protocol for integrating these nanomaterials into concrete. Incorporation of CNPs improved flexural toughness and reduced porosity, supporting their use in high-performance infrastructure applications. A technoeconomic analysis (TEA) confirmed that this process can produce CNP-loaded catalyst material at a levelized cost below $\$$7/kg across a range of catalyst loadings and reaction yields. With estimated market values for the carbon composite product ranging from $\$$14 to over $\$$60/kg, and the ability to blend CNPs into concrete at sub-percent levels with less than 10% added cost, the system presents a compelling economic case. While additional engineering work is needed to optimize fluidization and heat transfer at scale, this project establishes a strong foundation for commercial development. The process is not only technically sound but also economically promising, representing a viable pathway for flare gas mitigation through modular carbon nanomaterial production.

03 NATURAL GAS↗

Perspectives on the relationship between materials chemistry and roll-to-roll electrode manufacturing for high-energy lithium-ion batteries

As lithium-ion battery (LIB) active material and cell manufacturing costs continue to drop with wider adoption of electric vehicles, electrode and cell processing costs remain too high in terms of reaching the ultimate U.S. Department of Energy (DOE) cell cost target of $80/kWh. This paper primarily covers major materials chemistry advancements made over the last 10 years at Oak Ridge National Laboratory (ORNL) in the space of advanced manufacturing science for LIBs with the aim of simultaneously meeting the ultimate cost target, 500 Wh/kg gravimetric energy density, 10-15-min fast charge times, and 1000 deep discharge cycles. Aqeous electrode processing with a variety of active anode and cathode materials is now a standard procedure at the DOE Battery Manufacturing R&D Facility at ORNL (BMF), including the latest processes developed for Ni-rich cathodes. New results on cobalt-free LiNi 0.8 Fe 0.1 Al 0.1 O 2 (NFA 811) are also included and discussed in an electrode processing advantage context. In addition, colloidal processing advancements have been made for Si/C composite anodes for achieving >600 mA h/g capacities. Optimization of electrode coating parameters and drying protocols have been completed, which has elucidated how key processing variables need to be changed when parameters such as slurry solids loading, solvent type, and wet electrode thickness are changed. ORNL has also increased the line speeds at which thick cathodes can be processed using ultra-fast electron beam (EB) curing and substantially decreased formation cycling times to <1 day. Finally, key details of these advancements are discussed in the context of materials chemistry and process-property-performance relationships.

25 ENERGY STORAGE↗

Evolution of Ionomer Morphology from Dispersion to Film: An in Situ X-ray Study

Ion-conducting polymers (ionomers) have been extensively studied in solution, as membranes and substrate-supported thin films for various electrochemical energy-conversion devices, including fuel cells and electrolyzers. Formation of an ionomer film from a solution, however, is not well understood, despite its importance for fabrication of electrodes in energy devices. Here, the evolution of the perfluorinated sulfonic acid morphology upon casting from a solution is observed using in situ grazing-incidence small- and wide-angle X-ray scattering. Aggregate interactions in dispersion directly impact the hydrophilic-domain network of the cast film and the onset of crystallization occurs simultaneously with the solution-to-film transition but continues to evolve on different time scales. In addition, confinement is shown to induce anisotropic morphology at multiple length scales. These results show promise for elucidating the role of casting parameters, drying protocols, and ionomer-solvent interactions in governing film morphology and open new avenues for establishing structure/processing/property relationships for ionomer films and modifying their transport functionality at catalytic interfaces.

30 DIRECT ENERGY CONVERSION↗

The feasibility of a scanner-independent technique to estimate organ dose from MDCT scans: Using CTDI{sub vol} to account for differences between scanners

Purpose: Monte Carlo radiation transport techniques have made it possible to accurately estimate the radiation dose to radiosensitive organs in patient models from scans performed with modern multidetector row computed tomography (MDCT) scanners. However, there is considerable variation in organ doses across scanners, even when similar acquisition conditions are used. The purpose of this study was to investigate the feasibility of a technique to estimate organ doses that would be scanner independent. This was accomplished by assessing the ability of CTDI{sub vol} measurements to account for differences in MDCT scanners that lead to organ dose differences. Methods: Monte Carlo simulations of 64-slice MDCT scanners from each of the four major manufacturers were performed. An adult female patient model from the GSF family of voxelized phantoms was used in which all ICRP Publication 103 radiosensitive organs were identified. A 120 kVp, full-body helical scan with a pitch of 1 was simulated for each scanner using similar scan protocols across scanners. From each simulated scan, the radiation dose to each organ was obtained on a per mA s basis (mGy/mA s). In addition, CTDI{sub vol} values were obtained from each scanner for the selected scan parameters. Then, to demonstrate the feasibility of generating organ dose estimates from scanner-independent coefficients, the simulated organ dose values resulting from each scanner were normalized by the CTDI{sub vol} value for those acquisition conditions. Results: CTDI{sub vol} values across scanners showed considerable variation as the coefficient of variation (CoV) across scanners was 34.1%. The simulated patient scans also demonstrated considerable differences in organ dose values, which varied by up to a factor of approximately 2 between some of the scanners. The CoV across scanners for the simulated organ doses ranged from 26.7% (for the adrenals) to 37.7% (for the thyroid), with a mean CoV of 31.5% across all organs. However, when organ doses are normalized by CTDI{sub vol} values, the differences across scanners become very small. For the CTDI{sub vol}, normalized dose values the CoVs across scanners for different organs ranged from a minimum of 2.4% (for skin tissue) to a maximum of 8.5% (for the adrenals) with a mean of 5.2%. Conclusions: This work has revealed that there is considerable variation among modern MDCT scanners in both CTDI{sub vol} and organ dose values. Because these variations are similar, CTDI{sub vol} can be used as a normalization factor with excellent results. This demonstrates the feasibility of establishing scanner-independent organ dose estimates by using CTDI{sub vol} to account for the differences between scanners.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-D-BRD-00: Electronic Brachytherapy

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

60 APPLIED LIFE SCIENCES↗

MO-D-BRD-01: Clinical Implementation of An Electronic Brachytherapy Program for the Skin

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

60 APPLIED LIFE SCIENCES↗

MO-D-BRD-02: Radiological Physics and Surface Lesion Treatments with Electronic Brachytherapy

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-D-BRD-03: Radiobiology and Commissioning of Electronic Brachytherapy for IORT

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-D-BRD-04: NIST Air-Kerma Standard for Electronic Brachytherapy Calibrations

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

60 APPLIED LIFE SCIENCES↗

STITCHES: a Python package to amalgamate existing Earth system model output into new scenario realizations

Understanding the interaction between humans and the Earth system is a computationally daunting task, with many possible approaches depending on resources available and questions of interest. For example, state-of-the-art impact models require decade-long time series of relatively high frequency, spatially resolved and often multiple variables representing climatic impact-drivers (Ruane et al., 2022). Most commonly these are derived from the outputs of detailed, computationally expensive Earth System Models (ESMs) run according to a standard, limited set of future scenarios, the latest being the SSP-RCPs run under CMIP6/ScenarioMIP (Eyring et al., 2016; O’Neill et al., 2016). At the time of writing, O’Neill et al. (2016) has been cited more than 1750 times and Eyring et al. (2016) more than 5000 times, highlighting the broad, general applications of this data. Often, however, impact modeling seeks to explore new scenarios that were not part of the ScenarioMIP protocol, and/or needs a larger set of initial condition ensemble members than are typically available to quantify the effects of ESM internal variability. In addition, the recognition that the human and Earth systems are fundamentally intertwined, and may feature potentially significant feedback loops, is making integrated, simultaneous modeling of the coupled human-Earth system increasingly necessary, if computationally challenging with most existing tools (Thornton et al., 2017). For impact modelers, climate model emulators can be the answer to meet both the needs of: 1) creating realizations for novel scenarios and 2) achieving a simplified, computationally tractable representation of ESM behavior in a coupled human-Earth system modeling framework. We proposed a new, comprehensive approach to such emulation of gridded, multivariate ESM outputs for novel scenarios without the computational cost of a full ESM, STITCHES (Tebaldi et al., 2022). The approach outlined in Tebaldi et al. (2022) should be extensible to future CMIP eras, although the STITCHES software at present is strictly focused on CMIP6/ScenarioMIP data hosted on Pangeo (https://gallery.pangeo.io/repos/pangeo-gallery/cmip6/). The corresponding STITCHES Python package uses existing archives of ESMs’ scenario experiments from CMIP6/ScenarioMIP to construct gridded, multivariate realizations of new scenarios provided by reduced complexity climate models (Hartin et al., 2015; Meinshausen et al., 2011; Smith et al., 2018), or to enrich existing initial condition ensembles. Its output provides the same characteristics as the emulated ESM output: multivariate (spanning potentially all variables that the ESM has saved), spatially resolved (down to the native grid of the ESM), and preserving the same high frequency as the original data. A new realization of multiple variables can be generated on the order of minutes with STITCHES, rather than the hours or sometimes days that ESMs require.

97 MATHEMATICS AND COMPUTING↗

CSULA Hydrogen Refueling Facility Performance Evaluation and Optimization

Throughout its history, Cal State LA has been in the forefront of advanced energy and transportation technologies. The station is located at the intersection of two major highways in Los Angeles region and has a convenient access. It is capable of producing up to 60 kg/day and can fuel 15-20 vehicles per day. Cal State LA had partnered with DOE to establish a robust station operation and performance data collection program. This consisted of equipping the station with additional instrumentation and collecting fueling performance data for several years. The data was further furnished to NREL for processing and agglomeration with data from other stations. In addition to fueling, maintenance and failure events were shared as well as hydrogen purity reports. The station has also undergone several upgrades in fueling protocols and hardware for improved performance and code compliance.

08 HYDROGEN↗

Microreactor Incident-Free Transportation Radiation Dose Assessment

This report, prepared by Pacific Northwest National Laboratory (PNNL) for the U.S. Nuclear Regulatory Commission, provides an estimate of the radiation dose related to the transportation of microreactors following the regulatory limits established in Title 10 of the Code of Federal Regulations (10 CFR) 71.47(b). The transportation of irradiated microreactors poses unique challenges. Microreactors may be challenged to meet the current 10 mrem/hr limit at 2 meters from the vehicle in 10 CFR 71.47(b). The need to modify packaging to be within practical weight and size limits for shipping may limit the amount of shielding that can be applied for a microreactor transportation package design. Operational strategies that would necessitate moving a reactor within a short time after its operating life may result in higher radiation dose rates associated with lower cooling times. This study estimates the radiation dose to maximally exposed individuals (MEIs) under the current regulatory radiation level limit of 10 mrem/hr at 2 meters from the vehicle as well as alternative limits of 10, 50, 100, and 200 mrem/hr at 2 meters from the vehicle. This analysis expands on prior incident free transportation radiation dose assessments conducted for spent nuclear fuel (SNF) and radioactive waste transportation. The key factors analyzed include the microreactor fuel type and burnup, shipment cooling periods, shielding designs integrated into transport packaging, and exposure scenarios for MEIs for highway and rail transport. This report considers additional distances that may be associated with compensatory measures to ensure safe transport conditions under varying radiation dose limits, including enhanced routing measures, escort protocols, vehicle inspections, and operational restrictions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

MSAT network architecture

The Mobile Satellite (MSAT) communications system will support mobile voice and data services using circuit switched and packet switched facilities with interconnection to the public switched telephone network and private networks. Control of the satellite network will reside in a Network Control System (NCS) which is being designed to be extremely flexible to provide for the operation of the system initially with one multi-beam satellite, but with capability to add additional satellites which may have other beam configurations. The architecture of the NCS is described. The signalling system must be capable of supporting the protocols for the assignment of circuits for mobile public telephone and private network calls as well as identifying packet data networks. The structure of a straw-man signalling system is discussed.

Davies, N. G.↗