Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WAVELENGTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

On the modeling and optimization of Schottky varactor frequency multipliers at submillimeter wavelengths

Schottky varactor frequency multipliers are used to generate local oscillator power at millimeter and submillimeter wavelengths. The equivalent circuit of the Schottky varactor contains a junction capacitance, a junction conductance, a series resistance and a model for electron velocity saturation. A millimeter wavelengths the equivalent circuits is affected by the edge effects, which are due to the small-area circular anode. The correction factors due to the edge effect for the junction capacitance and for the series resistance are available in the literature. In this work the electron velocity saturation is modeled by limiting the velocity of the transition front between the depleted and undepleted layer. By using this model the maximum current of the diode is given by the actual area of the transition front between depleted and undepleted layers, and is therefore related to the capacitance correction factor. The new model has been tested by analyzing a two diode balanced doubler for 160 GHz presented earlier in the literature. The agreement between the theoretical results and the measurements is excellent. The new diode model is useful in optimization of varactors for high millimeter and submillimeter wave frequencies.

TRT-THEORETICAL↗

Long-wavelength 256x256 QWIP Hand-held Camera

In this paper, we discuss the development of very sensitive long wavelength infrared (LWIR) GaAs/AlxGa1-xAs quantum well infrared photodetectors (QWIPs), fabrication of random reflectors for efficient light coupling, and the demonstration of first hand-held long-wavelength 256x256 QWIP focal plane array camera. Excellent imagery, with a noise equivalent differential temperature of 25 mK has been achieved.

long↗

Precision Determination of Atmospheric Extinction at Optical and Near IR Wavelengths

The science goals for future ground-based all-sky surveys, such as the Dark Energy Survey, PanSTARRS, and the Large Synoptic Survey Telescope, require calibration of broadband photometry that is stable in time and uniform over the sky to precisions of a per cent or better, and absolute calibration of color measurements that are similarly accurate. This performance will need to be achieved with measurements made from multiple images taken over the course of many years, and these surveys will observe in less than ideal conditions. This paper describes a technique to implement a new strategy to directly measure variations of atmospheric transmittance at optical wavelengths and application of these measurements to calibration of ground-based observations. This strategy makes use of measurements of the spectra of a small catalog of bright 'probe' stars as they progress across the sky and back-light the atmosphere. The signatures of optical absorption by different atmospheric constituents are recognized in these spectra by their characteristic dependences on wavelength and airmass. State-of-the-art models of atmospheric radiation transport and modern codes are used to accurately compute atmospheric extinction over a wide range of observing conditions. We present results of an observing campaign that demonstrate that correction for extinction due to molecular constituents and aerosols can be done with precisions of a few millimagnitudes with this technique.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-client quantum key distribution using wavelength division multiplexing

Quantum Key Distribution (QKD) exploits the rules of quantum mechanics to generate and securely distribute a random sequence of bits to two spatially separated clients. Typically a QKD system can support only a single pair of clients at a time, and so a separate quantum link is required for every pair of users. We overcome this limitation with the design and characterization of a multi-client entangled-photon QKD system with the capacity for up to 100 clients simultaneously. The time-bin entangled QKD system includes a broadband down-conversion source with two unique features that enable the multi-user capability. First, the photons are emitted across a very large portion of the telecom spectrum. Second, and more importantly, the photons are strongly correlated in their energy degree of freedom. Using standard wavelength division multiplexing (WDM) hardware, the photons can be routed to different parties on a quantum communication network, while the strong spectral correlations ensure that each client is linked only to the client receiving the conjugate wavelength. In this way, a single down-conversion source can support dozens of channels simultaneously--and to the extent that the WDM hardware can send different spectral channels to different clients, the system can support multiple client pairings. We will describe the design and characterization of the down-conversion source, as well as the client stations, which must be tunable across the emission spectrum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assessment of radiography for diagnosing short wavelength instability growth and mix in NIF ignition capsules.

Understanding and controlling hydrodynamic instabilities is critical to achieving ignition at National Ignition Facility (NIF). High resolution x-ray radiography of a NIF capsule may be able to measure key aspects of short wavelength instability growth including time dependent areal density variations, the dominant wavelength of growth, amount of growth from isolated capsule defects on the ablator and ice surfaces, and growth of perturbations as a result of the fill tube or dust contaminants. Radiography of the capsule limb may also place constraints on the width of the ice/ablator mix layer. Measurement of these various observables are important to determine what effect target design changes has on instability growth and to validate code predictions. We present an analysis of 2D and 3D HYDRA simulations and demonstrate how radiography can be used to diagnose signatures of mix in NIC capsules.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single shot extreme ultraviolet laser imaging of nanostructures with wavelength resolution

We have demonstrated near-wavelength resolution microscopy in the extreme ultraviolet. Images of 50 nm diameter nanotubes were obtained with a single {approx}1 ns duration pulse from a desk-top size 46.9 nm laser. We measured the modulation transfer function of the microscope for three different numerical aperture zone plate objectives, demonstrating that 54 nm half-period structures can be resolved. The combination of near-wavelength spatial resolution and high temporal resolution opens myriad opportunities in imaging, such as the ability to directly investigate dynamics of nanoscale structures.

36 MATERIALS SCIENCE↗

Collecting EUV mask images through focus by wavelength tuning

Using an extreme-ultraviolet (EUV) microscope to produce high-quality images of EUV reticles, we have developed a new wavelength tuning method to acquire through-focus data series with a higher level of stability and repeatability than was previously possible. We utilize the chromatic focal-length dependence of a diffractive Fresnel zoneplate objective lens, and while holding the mask sample mechanically still, we tune the wavelength through a narrow range, in small steps. In this paper, we demonstrate the method and discuss the relative advantages that this data collection technique affords.

36 MATERIALS SCIENCE↗

Nanoscale Imaging with Resonant Coherent X Rays: Extension of Multiple-Wavelength Anomalous Diffraction to Nonperiodic Structures

The methodology of multiple-wavelength anomalous diffraction, widely used for macromolecular structure determination, is extended to the imaging of nonperiodic nanostructures. We demonstrate the solution of the phase problem by a combination of two resonantly recorded coherent scattering patterns at the carbon K edge (285 eV). Our approach merges iterative phase retrieval and x-ray holography approaches, yielding unique and rapid reconstructions. The element, chemical, and magnetic state specificity of our method further renders it widely applicable to a broad range of nanostructures, providing a spatial resolution that is limited, in principle, by wavelength only.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Accuracy Wavelength Calibration For A Scanning Visible Spectrometer

Spectroscopic applications for plasma velocity measurements often require wavelength accuracies ≤ 0.2Â. An automated calibration for a scanning spectrometer has been developed to achieve a high wavelength accuracy overr the visible spectrum, stable over time and environmental conditions, without the need to recalibrate after each grating movement. The method fits all relevant spectrometer paraameters using multiple calibration spectra. With a steping-motor controlled sine-drive, accuracies of ~0.025 Â have been demonstrated. With the addition of high resolution (0.075 aresec) optical encoder on the grading stage, greater precision (~0.005 Â) is possible, allowing absolute velocity measurements with ~0.3 km/s. This level of precision requires monitoring of atmospheric temperature and pressure and of grating bulk temperature to correct for changes in the refractive index of air and the groove density, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of at-wavelength metrology for x-ray optics at the ALS

The comprehensive realization of the exciting advantages of new third- and forth-generation synchrotron radiation light sources requires concomitant development of reflecting and diffractive x-ray optics capable of micro- and nano-focusing, brightness preservation, and super high resolution. The fabrication, tuning, and alignment of the optics are impossible without adequate metrology instrumentation, methods, and techniques. While the accuracy of ex situ optical metrology at the Advanced Light Source (ALS) has reached a state-of-the-art level, wavefront control on beamlines is often limited by environmental and systematic alignment factors, and inadequate in situ feedback. At ALS beamline 5.3.1, we are developing broadly applicable, high-accuracy, in situ, at-wavelength wavefront measurement techniques to surpass 100-nrad slope measurement accuracy for Kirkpatrick-Baez (KB) mirrors. The at-wavelength methodology we are developing relies on a series of tests with increasing accuracy and sensitivity. Geometric Hartmann tests, performed with a scanning illuminated sub-aperture determine the wavefront slope across the full mirror aperture. Shearing interferometry techniques use coherent illumination and provide higher sensitivity wavefront measurements. Combining these techniques with high precision optical metrology and experimental methods will enable us to provide in situ setting and alignment of bendable x-ray optics to realize diffraction-limited, sub 50 nm focusing at beamlines. We describe here details of the metrology beamline endstation, the x-ray beam diagnostic system, and original experimental techniques that have already allowed us to precisely set a bendable KB mirror to achieve a focused spot size of 150 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wavelength-specific reflections: A decade of EUV actinic mask inspection research

Mask inspection is essential for the success of any pattern-transfer lithography technology, and EUV Lithography in particular faces unique challenges. EUV masks resonant-reflective multilayer coatings have a narrow, wavelength-specific response that dramatically affects the way that defects appear, or disappear, at various illuminating wavelengths. Furthermore, the ever-shrinking size of 'critical' defects limits the potential effectiveness of DUV inspection techniques over time. Researchers pursuing numerous ways of finding and characterizing defects on EUV masks and have met with varying degrees of success. Their lessons inform the current, urgent exploration to select the most effective techniques for high-volume manufacturing. Ranging from basic research and demonstration experiments to commercial inspection tool prototypes, we survey the recent history of work in this area, including sixteen projects in Europe, Asia, and America. Solutions range from scanning beams to microscopy, dark field imaging to pattern transfer.

36 MATERIALS SCIENCE↗

Wavelength measurement of n = 3 - n' = 3 transitions in highly charged tungsten ions

3s{sub 1/2} - 3p{sub 3/2} and 3p{sub 1/2} - 3d{sub 3/2} transitions have been studied in potassium-like W{sup 55+} through neon-like W{sup 64}+ ions at the electron-beam ion trap facility in Livermore. The wavelengths of the lines have been measured in high resolution relative to well known reference lines from oxygen and nitrogen ions. Using the high-energy SuperEBIT electron-beam ion trap and an R = 44.3 m grazing-incidence soft x-ray spectrometer, the lines were observed with a cryogenic charge-coupled device camera. The wavelength data for the sodium-like and magnesium-like tungsten lines are compared with theoretical predictions for ions along the isoelectronic sequences.

74 ATOMIC AND MOLECULAR PHYSICS↗

Benefits of using multiple Raman laser wavelengths for characterizing defects in a UO 2 matrix

Abstract Raman spectroscopy is one of the most useful techniques for studying the structure of UO 2 and changes due to specific defects caused by doping, changes in stoichiometry, irradiation, or heating under oxidizing conditions. In this paper, we illustrate several aspects of the application of Raman techniques to the study of UO 2 , including the use of wavelength‐dependent excitation (455, 532, and 785 nm) to assess the effects of doping (Nd, Th, and Zr), ion irradiation, and in situ heating and oxidation (UO 2 to U 3 O 8 ). Additionally, we show examples of how correlative microscopy is possible using electron backscatter diffraction combined with Raman maps of specific vibration bands or of laser‐induced luminescence generated by rare‐earth dopants in the matrix. For each of these applications, we suggest optimal excitation wavelengths that vary depending on the desired data. Blue (455 nm) excitation tends to promote oxidation even at low powers, but because Raman spectra change little with doping, irradiation‐induced changes are easier to observe. Green (532 nm) excitation is optimal for observing electron–phonon resonance effects in UO 2 and offers a good compromise for high‐temperature oxidation experiments, delivering high‐quality spectra for both UO 2 and U 3 O 8 . Infrared (785 nm) excitation is best for observing “defect” bands associated with doping in UO 2 , as changes with irradiation are small. Raman spectroscopy is particularly suited for studying the stability of UO 2 towards oxidation in the presence of dopants simulating fission products, where electron–phonon resonant effects, dopant ion luminescence, and mapping can be used together to investigate structural rearrangement as a function of temperature. These techniques can offer insight into microstructural changes in UO 2 fuels at higher burnups envisioned in future reactors.

42 ENGINEERING↗

Investigation of goodness of model data fit using PLSR and PCR regression models to determine informative wavelength band in NIR region for non-invasive blood glucose prediction

Diabetes mellitus is a metabolic disorder characterized by the deficiency in insulin secretion or insulin action on target tissues. Diabetes being diagnosed, requires frequent monitoring. Current measurement techniques are invasive in nature, which is painful. Non-invasive measurement methods for the prediction of blood glucose is a big challenge. Hence this paper focuses on a comparative study to analyze the performance of the two regression models: partial least square regression (PLSR) and principal component regression (PCR) models to arrive at the best regression model for the prediction of blood glucose non-invasively based on NIR diffuse reflectance spectroscopy. The regression model developed involves spectral data collected from 32 subjects from a diabetic center using diffuse reflectance spectrometer (DRS). The spectroscopic data were acquired from the subjects both invasively using clinical method and non-invasively using DRS setup in the NIR spectral range whose wavelength ranges from 750 to 1040 nm. Multivariate analysis using PLSR is found to be a better regression model in terms of the fitted response and estimated mean square prediction error. It is observed that the mean square error value is 0.04 mg/dl for the tenth component in the PLSR model. The developed regression model also proves to be a useful tool in identifying the informative wavelength bands for blood glucose measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Near-UV and blue wavelength excitable Mg{sub 0.6}Ca{sub 2.16}Mo{sub 0.2}W{sub 0.8}O{sub 6}: Eu{sub 0.12}{sup 3+}/Na{sub 0.12}{sup +} high efficiency red phosphors

Red phosphors with narrow emission around 615 nm (with FWHM~5–10 nm) having chemical compositions of A{sub 0.6}Ca{sub 2.16}Mo{sub 0.2}W{sub 0.8}O{sub 6}: Eu{sub 0.12}{sup 3+}/Na{sub 0.12}{sup +} (A=Mg, Sr) have been found to exhibit the highest luminescence amongst the molybdate–tungstate family when excited by sources in the 380–420 nm wavelength range. Thus they are most suitable for enhancing color rendering index and lowering color temperature in phosphor converted white LEDs (pc-WLEDs) with near-UV/blue LED excitation sources. The excitation band edge in the near UV/blue wavelength in the reported phosphor has been attributed to the coordination environment of the transition metal ion (Mo{sup 6+}, W{sup 6+}) and host crystal structure. Furthermore the quantum efficiency of the phosphors has been enhanced by adjusting activator concentration, suitable compositional alloying using substitutional alkaline earth metal cations and charge compensation mechanisms. - Graphical abstract: The charge transfer excitation of orthorhombic Mg{sub 0.6}Ca{sub 2.16}Mo{sub 0.2}W{sub 0.8}O{sub 6}: Eu{sub 0.12}{sup 3+}/Na{sub 0.12}{sup +} is significantly higher than tetragonal CaMoO{sub 4}: Eu{sup 3+} phosphors making Mg{sub 0.6}Ca{sub 2.16}Mo{sub 0.2}W{sub 0.8}O{sub 6}: Eu{sub 0.12}{sup 3+}/Na{sub 0.12}{sup +} prime candidates for fabrication of warm white phosphor-converted LEDs. - Highlights: • LED excitable Mg{sub 0.6}Ca{sub 2.16}Mo{sub 0.2}W{sub 0.8}O{sub 6}: Eu{sub 0.12}{sup 3+}/Na{sub 0.12}{sup +} phosphors were synthesized. • These phosphors are 10 times more intense than CaMoO{sub 4}: Eu{sup 3+} red phosphors. • Their intensity and efficiency were enhanced by materials optimization techniques. • Such techniques include compositional alloying, charge compensation, etc.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Poly(sulfur-random-(1,3-diisopropenylbenzene)) based mid-wavelength infrared polarizer: Optical property experimental and theoretical analysis

Development of polymer based mid-wavelength infrared (MWIR) optics has been limited mainly due to high optical loss of organic polymers used in general optical components. In this study, a MWIR polarization grating based on a sulfuric polymer poly(sulfur-random-(1,3-diisopropenylbenzene)) with a low loss in the MWIR range was fabricated using a simple two-step process: imprint and metal deposition. Fourier-transform infrared (FTIR) spectroscopy measurement showed that this polymeric MWIR polarizer selectively transmitted the polarized IR in transverse magnetic (TM) mode over the transverse electric (TE) mode at normal incidence. The measured extinction ratios ( η = The ratio of transmissions in TM and TE) were 208, 176, and 212 at the wavelength of 3, 4, and 5 μm, respectively. The computational simulation and analytical model confirmed that the enhanced TM transmission efficiency and η followed a Fabry-Pérot (FP) resonance mode within the created sulfuric polymer film. This polymeric MWIR polarizer demonstrated a great potential for broader applications in IR photonics to realize low-cost and durable optical components.

42 ENGINEERING↗