RUSHMAPS: Real-Time Uploadable Spherical Harmonic Moment Analysis for Particle Spectrometers

RUSHMAPS is a new onboard data reduction scheme that gives real-time access to key science parameters (e.g. moments) of a class of heliophysics science and/or solar system exploration investigation that includes plasma particle spectrometers (PPS), but requires moments reporting (density, bulk-velocity, temperature, pressure, etc.) of higher-level quality, and tolerates a lowpass (variable quality) spectral representation of the corresponding particle velocity distributions, such that telemetry use is minimized. The proposed methodology trades access to the full-resolution velocity distribution data, saving on telemetry, for real-time access to both the moments and an adjustable-quality (increasing quality increases volume) spectral representation of distribution functions. Traditional onboard data storage and downlink bandwidth constraints severely limit PPS system functionality and drive cost, which, as a consequence, drives a limited data collection and lower angular energy and time resolution. This prototypical system exploit, using high-performance processing technology at GSFC (Goddard Space Flight Center), uses a SpaceCube and/or Maestro-type platform for processing. These processing platforms are currently being used on the International Space Station as a technology demonstration, and work is currently ongoing in a new onboard computation system for the Earth Science missions, but they have never been implemented in heliospheric science or solar system exploration missions. Preliminary analysis confirms that the targeted processor platforms possess the processing resources required for realtime application of these algorithms to the spectrometer data. SpaceCube platforms demonstrate that the target architecture possesses the sort of compact, low-mass/power, radiation-tolerant characteristics needed for flight. These high-performing hybrid systems embed unprecedented amounts of onboard processing power in the CPU (central processing unit), FPGAs (field programmable gate arrays), and DSP (digital signal processing) elements. The fundamental computational algorithm de constructs 3D velocity distributions in terms of spherical harmonic spectral coefficients (which are analogous to a Fourier sine-cosine decomposition), but uses instead spherical harmonics Legendre polynomial orthogonal functions as a basis for the expansion, portraying each 2D angular distribution at every energy or, geometrically, spherical speed-shell swept by the particle spectrometer. Optionally, these spherical harmonic spectral coefficients may be telemetered to the ground. These will provide a smoothed description of the velocity distribution function whose quality will depend on the number of coefficients determined. Successfully implemented on the GSFC-developed processor, the capability to integrate the proposed methodology with both heritage and anticipated future plasma particle spectrometer designs is demonstrated (with sufficiently detailed design analysis to advance TRL) to show specific science relevancy with future HSD (Heliophysics Science Division) solar-interplanetary, planetary missions, sounding rockets and/or CubeSat missions.

Figueroa-Vinas, Adolfo↗

Dark photon constraints from CMB temperature anisotropies

The resonant conversion, within the inter-galactic medium, of regular photons into dark photons amplifies the anisotropy observed in the CMB, thereby imposing stringent constraints on the existence of light dark photons. In this study, we investigate the impact of light dark photons, with masses in the range 3 × 10$^{-15}$ eV < mA' < 3 × 10$^{-12}$ eV on the power spectrum of temperature anisotropies within the cosmic microwave background (CMB) radiation utilizing the state-of-the-art large-volume FLAMINGO cosmological simulations. Our results show that using full Planck data, one can expect the existing constraints on the dark photon mixing parameter in this mass range to improve by an order of magnitude.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pore-scale supercritical CO 2 dissolution and mass transfer under drainage conditions

Abstract: Recently, both core- and pore-scale imbibition experiments have shown non-equilibrium dissolution of supercritical CO 2 (scCO 2 ) and a prolonged depletion of residual scCO 2 . In this study, pore-scale scCO 2 dissolution and mass transfer under drainage conditions were investigated using a two-dimensional heterogeneous micromodel and a novel fluorescent water dye with a sensitive pH range between 3.7 and 6.5. Drainage experiments were conducted at 9 MPa and 40 °C by injecting scCO 2 into the sandstone-analogue pore network initially saturated by water without dissolved CO 2 (dsCO 2 ). During the experiments, time-lapse images of dye intensity, reflecting water pH, were obtained. These images show non-uniform pH in individual pores and pore clusters, with average pH levels gradually decreasing with time. Further analysis on selected pores and pore clusters shows that (1) rate-limited mass transfer prevails with slowly decreasing pH over time when the scCO 2 -water interface area is low with respect to the volume of water-filled pores and pore clusters, (2) fast scCO 2 dissolution and phase equilibrium occurs when scCO 2 bubbles invade into water-filled pores, significantly enhancing the area-to-volume ratio, and (3) a transition from rate-limited to diffusion-limited mass transfer occurs in a single pore when a medium area-to-volume ratio is prevalent. The analysis also shows that two fundamental processes – scCO 2 dissolution at phase interfaces and diffusion of dsCO 2 at the pore scale (10-100 µm) observed after scCO 2 bubble invasion into water-filled pores without pore throat constraints – are relatively fast. The overall slow dissolution of scCO 2 in the millimeter-scale micromodel can be attributed to the small area-to-volume ratios that represent pore-throat configurations and characteristics of phase interfaces. This finding is applicable for the behavior of dissolution at pore, core, and field scales when water-filled pores and pore clusters of varying size are surrounded by scCO 2 at narrow pore throats.

54 ENVIRONMENTAL SCIENCES↗

A limited-angle intrafraction verification (LIVE) system for radiation therapy

Purpose: Currently, no 3D or 4D volumetric x-ray imaging techniques are available for intrafraction verification of target position during actual treatment delivery or in-between treatment beams, which is critical for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) treatments. This study aims to develop a limited-angle intrafraction verification (LIVE) system to use prior information, deformation models, and limited angle kV-MV projections to verify target position intrafractionally. Methods: The LIVE system acquires limited-angle kV projections simultaneously during arc treatment delivery or in-between static 3D/IMRT treatment beams as the gantry moves from one beam to the next. Orthogonal limited-angle MV projections are acquired from the beam's eye view (BEV) exit fluence of arc treatment beam or in-between static beams to provide additional anatomical information. MV projections are converted to kV projections using a linear conversion function. Patient prior planning CT at one phase is used as the prior information, and the on-board patient volume is considered as a deformation of the prior images. The deformation field is solved using the data fidelity constraint, a breathing motion model extracted from the planning 4D-CT based on principal component analysis (PCA) and a free-form deformation (FD) model. LIVE was evaluated using a 4D digital extended cardiac torso phantom (XCAT) and a CIRS 008A dynamic thoracic phantom. In the XCAT study, patient breathing pattern and tumor size changes were simulated from CT to treatment position. In the CIRS phantom study, the artificial target in the lung region experienced both size change and position shift from CT to treatment position. Varian Truebeam research mode was used to acquire kV and MV projections simultaneously during the delivery of a dynamic conformal arc plan. The reconstruction accuracy was evaluated by calculating the 3D volume percentage difference (VPD) and the center of mass (COM) difference of the tumor in the true on-board images and reconstructed images. Results: In both simulation and phantom studies, LIVE achieved substantially better reconstruction accuracy than reconstruction using PCA or FD deformation model alone. In the XCAT study, the average VPD and COM differences among different patient scenarios for LIVE system using orthogonal 30° scan angles were 4.3% and 0.3 mm when using kV+BEV MV. Reducing scan angle to 15° increased the average VPD and COM differences to 15.1% and 1.7 mm. In the CIRS phantom study, the VPD and COM differences for the LIVE system using orthogonal 30° scan angles were 6.4% and 1.4 mm. Reducing scan angle to 15° increased the VPD and COM differences to 51.9% and 3.8 mm. Conclusions: The LIVE system has the potential to substantially improve intrafraction target localization accuracy by providing volumetric verification of tumor position simultaneously during arc treatment delivery or in-between static treatment beams. With this improvement, LIVE opens up a new avenue for margin reduction and dose escalation in both fractionated treatments and SRS and SBRT treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-150: Comparing Normal Tissue Irradiated Volumes for Proton Vs. Photon Treatment Plans On Lung Patients

Purpose: The aim of this work is to compare the “irradiated volume” (IRV) of normal tissues receiving 5, 20, 50, 80 and 90% or higher of the prescription dose with passively scattered proton therapy (PSPT) vs. IMRT of lung cancer patients. The overall goal of this research is to understand the factors affecting outcomes of a randomized PSPT vs. IMRT lung trial. Methods: Thirteen lung cancer patients, selected randomly, were analyzed. Each patient had PSPT and IMRT 74 Gy (RBE) plans meeting the same normal tissue constraints generated. IRVs were created for pairs of IMRT and PSPT plans on each patient. The volume of iGTV, (respiratory motion-incorporated GTV) was subtracted from each IRV to create normal tissue irradiated volume IRVNT. The average of IRVNT DVHs over all patients was also calculated for both modalities and inter-compared as were the selected dose-volume indices. Probability (p value) curves were calculated based on the Wilcoxon matched-paired signed-rank test to determine the dose regions where the statistically significant differences existed. Results: As expected, the average 5, 20 and 50% IRVNT’s for PSPT was found to be significantly smaller than for IMRT (p < 0.001, 0.01, and 0.001 respectively). However, the average 90% IRVNT for PSPT was greater than for IMRT (p = 0.003) presumably due to larger penumbra of protons and the long range of protons in lower density media. The 80% IRVNT for PSPT was also larger but not statistically distinguishable (p = .224). Conclusion: PSPT modality has smaller irradiated volume at lower doses, but larger volume at high doses. A larger cohort of lung patients will be analyzed in the future and IRVNT of patients treated with PSPT and IMRT will be compared to determine if the irradiated volumes (the magnitude of “dose bath”) correlate with outcomes.

60 APPLIED LIFE SCIENCES↗

The Orthogonal In-Situ Machining of Single and Polycrystalline Aluminum and Copper, Volume 1

Metal cutting is a unique deformation process characterized by large strains, exceptionally high strain rates and few constraints to the deformation. These factors, along with the difficulty of directly measuring the shear angle, make chip formation difficult to model and understand. One technique for skirting the difficulty of post mortem chip measurement is to perform a cutting experiment dynamically in a scanning electron microscope. The performance of the in-situ experiment with full instrumentation allows for component force measurement, orientation measurement (on a round single crystal disk) and a timing device, all superimposed below the deformation on the TV monitor and recorded for future viewing. This allows the sher angle to be directly measured for the screen along with the other needed information.

Cohen, P. H.↗

Finite Volume schemes on unstructured grids for non-local models: Application to the simulation of heat transport in plasmas

In the so-called Spitzer-Haerm regime, equations of plasma physics reduce to a nonlinear parabolic equation for the electronic temperature. Coming back to the derivation of this limiting equation through hydrodynamic regime arguments, one is led to construct a hierarchy of models where the heat fluxes are defined through a non-local relation which can be reinterpreted as well by introducing coupled diffusion equations. We address the question of designing numerical methods to simulate these equations. The basic requirement for the scheme is to be asymptotically consistent with the Spitzer-Haerm regime. Furthermore, the constraints of physically realistic simulations make the use of unstructured meshes unavoidable. We develop a Finite Volume scheme, based on Vertex-Based discretization, which reaches these objectives. We discuss on numerical grounds the efficiency of the method, and the ability of the generalized models in capturing relevant phenomena missed by the asymptotic problem.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-580: Comparison of Cervical Carcinoma IMRT Plans From Four Commercial Treatment Planning Systems (TPS)

Purpose: Different treatment planning systems (TPS) use different treatment optimization and leaf sequencing algorithms. This work compares cervical carcinoma IMRT plans optimized with four commercial TPSs to investigate the plan quality in terms of target conformity and delivery efficiency. Methods: Five cervical carcinoma cases were planned with the Corvus, Monaco, Pinnacle and Xio TPSs by experienced planners using appropriate optimization parameters and dose constraints to meet the clinical acceptance criteria. Plans were normalized for at least 95% of PTV to receive the prescription dose (Dp). Dose-volume histograms and isodose distributions were compared. Other quantities such as Dmin(the minimum dose received by 99% of GTV/PTV), Dmax(the maximum dose received by 1% of GTV/PTV), D100, D95, D90, V110%, V105%, V100% (the volume of GTV/PTV receiving 110%, 105%, 100% of Dp), conformity index(CI), homogeneity index (HI), the volume of receiving 40Gy and 50 Gy to rectum (V40,V50) ; the volume of receiving 30Gy and 50 Gy to bladder (V30,V50) were evaluated. Total segments and MUs were also compared. Results: While all plans meet target dose specifications and normal tissue constraints, the maximum GTVCI of Pinnacle plans was up to 0.74 and the minimum of Corvus plans was only 0.21, these four TPSs PTVCI had significant difference. The GTVHI and PTVHI of Pinnacle plans are all very low and show a very good dose distribution. Corvus plans received the higer dose of normal tissue. The Monaco plans require significantly less segments and MUs to deliver than the other plans. Conclusion: To deliver on a Varian linear-accelerator, the Pinnacle plans show a very good dose distribution. Corvus plans received the higer dose of normal tissue. The Monaco plans have faster beam delivery.

60 APPLIED LIFE SCIENCES↗

LARGE volume string compactifications at finite temperature

We present a detailed study of the finite-temperature behaviour of the LARGE Volume type IIB flux compactifications. We show that certain moduli can thermalise at high temperatures. Despite that, their contribution to the finite-temperature effective potential is always negligible and the latter has a runaway behaviour. We compute the maximal temperature T{sub max}, above which the internal space decompactifies, as well as the temperature T{sub *}, that is reached after the decay of the heaviest moduli. The natural constraint T{sub *} < T{sub max} implies a lower bound on the allowed values of the internal volume V. We find that this restriction rules out a significant range of values corresponding to smaller volumes of the order V ∼ 10{sup 4}l{sub s}{sup 6}, which lead to standard GUT theories. Instead, the bound favours values of the order V ∼ 10{sup 15}l{sub s}{sup 6}, which lead to TeV scale SUSY desirable for solving the hierarchy problem. Moreover, our result favours low-energy inflationary scenarios with density perturbations generated by a field, which is not the inflaton. In such a scenario, one could achieve both inflation and TeV-scale SUSY, although gravity waves would not be observable. Finally, we pose a two-fold challenge for the solution of the cosmological moduli problem. First, we show that the heavy moduli decay before they can begin to dominate the energy density of the Universe. Hence they are not able to dilute any unwanted relics. And second, we argue that, in order to obtain thermal inflation in the closed string moduli sector, one needs to go beyond the present EFT description.

79 ASTRONOMY AND ASTROPHYSICS↗

Calcium Phosphate Constraints in HLW Glasses: Phosphate Liquidus Model

About 50 million gallons of high-level mixed waste is currently stored in underground tanks at the United States Department of Energy’s (DOE’s) Hanford site in the State of Washington. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) will provide DOE’s Office of River Protection (ORP) with a means of treating this waste by vitrification for subsequent disposal. The tank waste will be separated into low- and high-activity waste fractions, which will then be vitrified respectively into Immobilized Low Activity Waste (ILAW) and Immobilized High Level Waste (IHLW) products. The ILAW product will be disposed in an engineered facility on the Hanford site while the IHLW product is designed for acceptance into a national geological disposal facility for high-level nuclear waste. The ILAW and IHLW products must meet a variety of requirements before they can be accepted for disposal. Glass property-composition models will be used to control the vitrification process at the WTP to ensure that the glass meets product quality and processability requirements. The quality and the validity ranges of the property-composition models and the supporting database will greatly influence waste treatment operations, including the waste loading that is achievable in the glass for each waste composition. The current baseline models for operation of the WTP were developed under the Bechtel National, Inc. (BNI) WTP contract. These models were based on LAW and HLW glass property data over a range of compositions that was guided primarily by the WTP contract and the set of tanks specified therein. The HLW testing was directed towards waste streams from the then-planned early feed tanks for the WTP (i.e., AZ-101, AZ-102, C-106/AY-102, and C-104/AY-101). These wastes are high in iron (AZ-101, AZ-102, and C-106/AY-102) or thorium (C-104/AY-101). While the baseline models may be adequate for commissioning of the facility and processing of the specified tanks, refinements and extensions or augmentations of these models will be required to process the balance of the tank waste inventory. The overall mission of the WTP will require the immobilization of tank waste compositions that are variously dominated by mixtures of aluminum, chromium, bismuth, iron, phosphorous, zirconium, and sulfur compounds as waste-loading-limiting components. Further, the WTP contract includes minimum waste loading requirements that are generally rather modest while loadings significantly higher than those in the current baseline are likely achievable. In order to achieve these higher waste loadings and to expand the applicable composition regions, new models will be needed to support the optimized operation of the WTP. Since the development of the baseline WTP models, ORP directed a program of work at the Vitreous State Laboratory (VSL) to examine various approaches for optimization of the performance of the WTP, including increasing the waste loadings in the LAW and HLW glass products. That work involved HLW rich in Al, Al+Na, Cr, Bi, S, Zr, Sr, P and Fe, in contrast to old baseline models that were based mostly on HLW tanks that were high in Fe, with one other that was also high in Th. Glass property data collected under the ORP program were compiled and combined with data collected to develop the WTP models. The combined databases have been used to update pre-existing HLW composition models or to develop new models for properties such as Product Consistency Test (PCT) responses, spinel crystallization (one-percent crystal fraction temperature, T 1% ), melt viscosity, melt electrical conductivity, nepheline formation upon slow cooling (i.e., Canister Centerline Cooling [CCC]), and Toxicity Characteristic Leach Procedure (TCLP) Cd response. While spinel is typically the most commonly occurring phase in HLW glasses, other phases can be limiting depending on the waste and glass composition. For example, various phosphate phases can become important as the phosphorus content increases. Lithium phosphate crystallization can impact PCT releases of HLW glasses, while calcium phosphate phases forming in the cold-cap can deleteriously impact feed processing in the melter. At present, however, no models exist that relate glass composition and crystallization of phosphate phases in general and calcium phosphate in particular. The present work was therefore directed towards the initial development of such models. Future work may be directed at studying amorphous phase separation in high phosphate HLW glasses. Within the River Protection Project, feed compositions are projected using the Hanford Tank Waste Operations Simulator (HTWOS), a dynamic computer model that tracks the waste through storage, retrieval, feed staging, and treatment processes. A review of the HTWOS data shows that WTP will process 4106 batches of HLW glass for the overall mission (System Plan Rev. 6, ORP-11242), each with its own waste feed and glass composition. Some of the projected HTWOS feed batches are expected to have relatively high concentrations of phosphorous compared to typical HLW streams. In the 4106 batches of HLW for the overall WTP mission P 2 O 5 varies from 0.59 wt% to 13.00 wt%, with 95 batches containing at least 10 wt% P 2 O 5 . Occurrences of phosphate crystals have commonly been noted in glasses with high bismuth and phosphorus contents. In addition, recently collected data from a set of statistically designed HLW matrix glasses prepared and characterized to support enhancement of the HLW glass property-composition models identified apatite in a number of glass samples. However, the current HLW model for crystallization (one-percent crystal fraction temperature) is applicable only to spinel crystallization in glasses. Previous projections of waste loadings and glass volume (such as those in System Plan Rev. 6, ORP-11242) have used preliminary constraints for calcium phosphate crystallization that are based on the limited available data. Additional data and improved constraints or, preferably, models that relate glass composition to crystallization of phosphate-containing phases, are therefore needed to support HLW vitrification at the WTP. The present study focuses on the development of such a model based on data from previously characterized glasses and a set of newly fabricated glasses.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling of Salivary Production Recovery After Radiotherapy Using Mixed Models: Determination of Optimal Dose Constraint for IMRT Planning and Construction of Convenient Tools to Predict Salivary Function

Purpose: The mathematical relationship between the dose to the parotid glands and salivary gland production needs to be elucidated. This study, which included data from patients included in a French prospective study assessing the benefit of intensity-modulated radiotherapy (RT), sought to elaborate a convenient and original model of salivary recovery. Methods and Materials: Between January 2001 and December 2004, 44 patients were included (35 with oropharyngeal and 9 with nasopharyngeal cancer). Of the 44 patients, 24 were treated with intensity-modulated RT, 17 with three-dimensional conformal RT, and 2 with two-dimensional RT. Stimulated salivary production was collected for {<=}24 months after RT. The data of salivary production, time of follow-up, and dose to parotid gland were modeled using a mixed model. Several models were developed to assess the best-fitting variable for the dose level to the parotid gland. Results: Models developed with the dose to the contralateral parotid fit the data slightly better than those with the dose to both parotids, suggesting that contralateral and ipsilateral parotid glands are not functionally equivalent even with the same dose level to the glands. The best predictive dose-value variable for salivary flow recovery was the volume of the contralateral parotid gland receiving >40 Gy. Conclusion: The results of this study show that the recommendation of a dose constraint for intensity-modulated RT planning should be established at the volume of the contralateral parotid gland receiving >40 Gy rather than the mean dose. For complete salivary production recovery after 24 months, the volume of the contralateral parotid gland receiving >40 Gy should be <33%. Our results permitted us to establish two convenient tools to predict the saliva production recovery function according to the dose received by the contralateral parotid gland.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity modulated and volumetric modulated arc radiotherapy

This study examines and compares the dosimetric quality of radiotherapy treatment plans for prostate carcinoma across a cohort of 163 patients treated across five centres: 83 treated with three-dimensional conformal radiotherapy (3DCRT), 33 treated with intensity modulated radiotherapy (IMRT) and 47 treated with volumetric modulated arc therapy (VMAT). Treatment plan quality was evaluated in terms of target dose homogeneity and organs at risk (OAR), through the use of a set of dose metrics. These included the mean, maximum and minimum doses; the homogeneity and conformity indices for the target volumes; and a selection of dose coverage values that were relevant to each OAR. Statistical significance was evaluated using two-tailed Welch's T-tests. The Monte Carlo DICOM ToolKit software was adapted to permit the evaluation of dose metrics from DICOM data exported from a commercial radiotherapy treatment planning system. The 3DCRT treatment plans offered greater planning target volume dose homogeneity than the other two treatment modalities. The IMRT and VMAT plans offered greater dose reduction in the OAR: with increased compliance with recommended OAR dose constraints, compared to conventional 3DCRT treatments. When compared to each other, IMRT and VMAT did not provide significantly different treatment plan quality for like-sized tumour volumes. This study indicates that IMRT and VMAT have provided similar dosimetric quality, which is superior to the dosimetric quality achieved with 3DCRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Broadly Adaptive Array of Dose-Constraint Templates for Planning of Intensity-Modulated Radiation Therapy for Advanced T-Stage Nasopharyngeal Carcinoma

Purpose: To develop and validate adaptive dose-constraint templates in intensity-modulated radiotherapy (IMRT) planning for advanced T-stage nasopharyngeal carcinoma (NPC). Method and Materials: Dose-volume histograms of clinically approved plans for 20 patients with advanced T-stage NPC were analyzed, and the pattern of distribution in relation to the degree of overlap between targets and organs at risk (OARs) was explored. An adaptive dose constraint template (ADCT) was developed based on the degree of overlap. Another set of 10 patients with advanced T-stage NPC was selected for validation. Results of the manual arm optimization protocol and the ADCT optimization protocol were compared with respect to dose optimization time, conformity indices, multiple-dose end points, tumor control probability, and normal tissue complication probability. Results: For the ADCT protocol, average time required to achieve an acceptable plan was 9 minutes, with one optimization compared with 94 minutes with more than two optimizations of the manual arm protocol. Target coverage was similar between the manual arm and ADCT plans. A more desirable dose distribution in the region of overlap between planning target volume and OARs was achieved in the ADCT plan. Dose end points of OARs were similar between the manual arm and ADCT plans. Conclusions: With the developed ADCT, IMRT treatment planning becomes more efficient and less dependent on the planner's experience on dose optimization. The developed ADCT is applicable to a wide range of advanced T-stage NPC treatment and has the potential to be applied in a broader context to IMRT planning for other cancer sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proton Radiotherapy for Childhood Ependymoma: Initial Clinical Outcomes and Dose Comparisons

Purpose: To report preliminary clinical outcomes for pediatric patients treated with proton beam radiation for intracranial ependymoma and compare the dose distributions of intensity-modulated radiation therapy with photons (IMRT), three-dimensional conformal proton radiation, and intensity-modulated proton radiation therapy (IMPT) for representative patients. Methods and Materials: All children with intracranial ependymoma confined to the supratentorial or infratentorial brain treated at the Francis H. Burr Proton Facility and Harvard Cyclotron between November 2000 and March 2006 were included in this study. Seventeen patients were treated with protons. Proton, IMRT, and IMPT plans were generated with similar clinical constraints for representative infratentorial and supratentorial ependymoma cases. Tumor and normal tissue dose-volume histograms were calculated and compared. Results: At a median follow-up of 26 months from the start date of radiation therapy, local control, progression-free survival, and overall survival rates were 86%, 80%, and 89%, respectively. Subtotal resection was significantly associated with decreased local control (p = 0.016). Similar tumor volume coverage was achieved with IMPT, proton therapy, and IMRT. Substantial normal tissue sparing was seen with proton therapy compared with IMRT. Use of IMPT will allow for additional sparing of some critical structures. Conclusions: Preliminary disease control with proton therapy compares favorably with the literature. Dosimetric comparisons show the advantage of proton radiation compared with IMRT in the treatment of ependymoma. Further sparing of normal structures appears possible with IMPT. Superior dose distributions were accomplished with fewer beam angles with the use of protons and IMPT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of Helical Tomotherapy in Stereotactic Body Radiation Therapy for Centrally Located Early Stage Non-Small-Cell Lung Cancer or Lung Metastases

Purpose: To investigate the ability of helical tomotherapy (HT) to spare critical organs immediately adjacent to the tumor target in stereotactic body radiation therapy (SBRT) for centrally located lung lesions. Methods and Materials: HT SBRT plans for 10 patients with centrally located lesions or lesions immediately adjacent to a critical structure were generated. A total of 70 Gy in 10 fractions was prescribed to the planning target volume (PTV) to satisfy a target volume coverage of {>=}95% PTV receiving 70 Gy and an established set of dose constraints for the organs at risk (OARs). Quality assurance (QA) of the HT plans was performed with both ion chamber and film measurements. Results: The PTV coverage criteria was met with 95% of the PTV receiving 70.68 {+-} 0.33 Gy for all cases even though the OARs immediately adjacent to the PTV ranged from 0.38 to 0.85 cm away. The mean lung dose (MLD), and V{sub 20} were 7.15 {+-} 1.44 Gy, and 11.93 {+-} 3.24 % for the total lung, respectively. The dose parameters of MLD, V{sub 5}, V{sub 10}, and V{sub 20} for the contralateral lung were significantly lower than those for the ipsilateral lung (p < 0.05). An average dose fall off from the PTV periphery to the edge of the immediately adjacent OAR was 47.6% over an average distance of 4.87 mm. Comparison of calculated and measured doses with the ion chamber showed an average of 1.85% point dose error, whereas an average mean gamma and the area with a gamma larger than 1 of 0.20 and 0.94% were observed, respectively. Conclusion: HT allows the sparing of critical structures immediately adjacent to the tumor target, thus making SBRT for these centrally located lesions feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spine stereotactic body radiation therapy plans: Achieving dose coverage, conformity, and dose falloff

We report our experience of establishing planning objectives to achieve dose coverage, conformity, and dose falloff for spine stereotactic body radiation therapy (SBRT) plans. Patients with spine lesions were treated using SBRT in our institution since September 2009. Since September 2011, we established the following planning objectives for our SBRT spine plans in addition to the cord dose constraints: (1) dose coverage—prescription dose (PD) to cover at least 95% planning target volume (PTV) and 90% PD to cover at least 99% PTV; (2) conformity index (CI)—ratio of prescription isodose volume (PIV) to the PTV < 1.2; (3) dose falloff—ratio of 50% PIV to the PTV (R{sub 50%}); (4) and maximum dose in percentage of PD at 2 cm from PTV in any direction (D{sub 2cm}) to follow Radiation Therapy Oncology Group (RTOG) 0915. We have retrospectively reviewed 66 separate spine lesions treated between September 2009 and December 2012 (31 treated before September 2011 [group 1] and 35 treated after [group 2]). The χ{sup 2} test was used to examine the difference in parameters between groups. The PTV V{sub 100%} {sub PD} ≥ 95% objective was met in 29.0% of group 1 vs 91.4% of group 2 (p < 0.01) plans. The PTV V{sub 90%} {sub PD} ≥ 99% objective was met in 38.7% of group 1 vs 88.6% of group 2 (p < 0.01) plans. Overall, 4 plans in group 1 had CI > 1.2 vs none in group 2 (p = 0.04). For D{sub 2cm}, 48.3% plans yielded a minor violation of the objectives and 16.1% a major violation for group 1, whereas 17.1% exhibited a minor violation and 2.9% a major violation for group 2 (p < 0.01). Spine SBRT plans can be improved on dose coverage, conformity, and dose falloff employing a combination of RTOG spine and lung SBRT protocol planning objectives.

61 RADIATION PROTECTION AND DOSIMETRY↗

Strong North Pacific Subtropical Mode Water Volume and Density Decrease in Year 1999

Abstract A strong decrease of volume and density of North Pacific Subtropical Mode Water (NPSTMW) in 1999 was analyzed in a regional high‐resolution (0.1°) numerical ocean circulation model simulation. Both shoaling of the bottom and deepening of the top of the NPSTMW layer contributed equally to volume decrease. They were locally governed by different physical processes, but both seem to be associated with basin‐wide changes in wind. A westward propagating negative thermocline depth anomaly that developed in the Central Pacific when the Pacific Decadal Oscillation index changed from a positive to a negative phase in 1998 caused shoaling of the bottom of the NPSTMW layer. Deepening of the top of the NPSTMW layer was due to an increase in the near surface stratification, caused by an increase in wind‐driven lateral heat transport convergence by the Kuroshio Extension jet starting in 1997. Both processes increased the potential vorticity in the NPSTMW region, decreasing the volume of water in the NPSTMW density range that satisfied the low potential vorticity constraint that is part of the definition of “mode water.” The strong near‐surface density decrease provided preconditioning for preferential surface formation of a lighter variety of NPSTMW, further decreasing its density. It also resulted in decrease of the outcrop window in the NPSTMW density range, strongly reducing its formation rate in 1998 and 1999 despite strong surface heat loss.

Cerovečki, I.↗