Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Benchmarking of Improved DPAC Transient Deflagration Analysis Code

The deflagration pressure analysis code (DPAC) has been upgraded for use in modeling hydrogen deflagration transients. The upgraded code is benchmarked using data from vented hydrogen deflagration tests conducted at the HYDRO-SC Test Facility at the University of Pisa. DPAC originally was written to calculate peak pressures for deflagrations in radioactive waste storage tanks and process facilities at the Savannah River Site. Upgrades include the addition of a laminar flame speed correlation for hydrogen deflagrations and a mechanistic model for turbulent flame propagation, incorporation of inertial effects during venting, and inclusion of the effect of water vapor condensation on vessel walls. In addition, DPAC has been coupled with chemical equilibrium with applications (CEA), a NASA combustion chemistry code. The deflagration tests are modeled as end-to-end deflagrations. As a result, the improved DPAC code successfully predicts both the peak pressures during the deflagration tests and the times at which the pressure peaks.

42 ENGINEERING↗

Retrofit Integrated Space & Water Heating: Field Assessment: Minneapolis, Minnesota (Fact Sheet)

This project analyzed combined condensing water heaters or boilers and hydronic air coils to provide high efficiency domestic hot water and forced air space heating. Called 'Combi' systems, they provided similar space and water heating performance less expensively than installing two condensing appliances. The system's installed costs were cheaper than installing a condensing furnace and either a condensing tankless or condensing storage water heater. However, combi costs must mature and be reduced before they are competitive with a condensing furnace and power vented water heater (EF of 0.60). Better insulation and tighter envelopes are reducing space heating loads for new and existing homes. For many homes, decreased space heating loads make it possible for both space and domestic water heating loads to be provided with a single heating plant. These systems can also eliminate safety issues associated with natural draft appliances through the use of one common sealed combustion vent.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Status update of the BWR cask simulator

The performance of commercial nuclear spent fuel dry storage casks are typically evaluated through detailed numerical analysis of the system's thermal performance. These modeling efforts are performed by the vendor to demonstrate the performance and regulatory compliance and are independently verified by the Nuclear Regulatory Commission (NRC). Carefully measured data sets generated from testing of full sized casks or smaller cask analogs are widely recognized as vital for validating these models. Numerous studies have been previously conducted. Recent advances in dry storage cask designs have moved the storage location from above ground to below ground and significantly increased the maximum thermal load allowed in a cask in part by increasing the canister helium pressure. Previous cask performance validation testing did not capture these parameters. The purpose of the investigation described in this report is to produce a data set that can be used to test the validity of the assumptions associated with the calculations presently used to determine steady-state cladding temperatures in modern dry casks. These modern cask designs utilize elevated helium pressure in the sealed canister or are intended for subsurface storage. The BWR cask simulator (BCS) has been designed in detail for both the above ground and below ground venting configurations. The pressure vessel representing the canister has been designed, fabricated, and pressure tested for a maximum allowable pressure (MAWP) rating of 24 bar at 400 C. An existing electrically heated but otherwise prototypic BWR Incoloy-clad test assembly is being deployed inside of a representative storage basket and cylindrical pressure vessel that represents the canister. The symmetric single assembly geometry with well-controlled boundary conditions simplifies interpretation of results. Various configurations of outer concentric ducting will be used to mimic conditions for above and below ground storage configurations of vertical, dry cask systems with canisters. Radial and axial temperature profiles will be measured for a wide range of decay power and helium cask pressures. Of particular interest is the evaluation of the effect of increased helium pressure on heat load and the effect of simulated wind on a simplified below ground vent configuration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measure Guideline: Steam System Balancing and Tuning for Multifamily Residential Buildings

This guideline provides building owners, professionals involved in multifamily audits, and contractors insights for improving the balance and tuning of steam systems. It provides readers an overview of one-pipe steam heating systems, guidelines for evaluating steam systems, typical costs and savings, and guidelines for ensuring quality installations. It also directs readers to additional resources for details not included here. Measures for balancing a distribution system that are covered include replacing main line vents and upgrading radiator vents. Also included is a discussion on upgrading boiler controls and the importance of tuning the settings on new or existing boiler controls. The guideline focuses on one-pipe steam systems, though many of the assessment methods can be generalized to two-pipe steam systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Retrofitting Forced Air Combi Systems: A Cold Climate Field Assessment

This project analyzed combined condensing water heaters or boilers and hydronic air coils to provide high efficiency domestic hot water (DHW) and forced air space heating. Called 'combi' systems, they provided similar space and water heating performance less expensively than installing two condensing appliances. The system's installed costs were cheaper than installing a condensing furnace and either a condensing tankless or condensing storage water heater. However, combi costs must mature and be reduced before they are competitive with a condensing furnace and power vented water heater (energy factor of 0.60). Better insulation and tighter envelopes are reducing space heating loads for new and existing homes. For many homes, decreased space heating loads make it possible for both space and domestic water heating loads to be provided with a single heating plant. These systems can also eliminate safety issues associated with natural draft appliances through the use of one common sealed combustion vent. The combined space and water heating approach was not a new idea. Past systems have used non-condensing heating plants, which limited their usefulness in climates with high heating loads. Previous laboratory work (Schoenbauer et al. 2012a) showed that proper installation was necessary to achieve condensing with high efficiency appliances. Careful consideration was paid to proper system sizing and minimizing the water temperature returning from the air handling unit to facilitate condensing operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Complete genome sequence of Candidatus Ruthia magnifica

The hydrothermal vent clam Calyptogena magnifica (Bivalvia: Mollusca) is a member of the Vesicomyidae. Species within this family form symbioses with chemosynthetic Gammaproteobacteria. They exist in environments such as hydrothermal vents and cold seeps and have a rudimentary gut and feeding groove, indicating a large dependence on their endosymbionts for nutrition. The C. magnifica symbiont, Candidatus Ruthia magnifica, was the first intracellular sulfur-oxidizing endosymbiont to have its genome sequenced (Newton et al. 2007). Here we expand upon the original report and provide additional details complying with the emerging MIGS/MIMS standards. The complete genome exposed the genetic blueprint of the metabolic capabilities of the symbiont. Genes which were predicted to encode the proteins required for all the metabolic pathways typical of free-living chemoautotrophs were detected in the symbiont genome. These include major pathways including carbon fixation, sulfur oxidation, nitrogen assimilation, as well as amino acid and cofactor/vitamin biosynthesis. This genome sequence is invaluable in the study of these enigmatic associations and provides insights into the origin and evolution of autotrophic endosymbiosis.

59 BASIC BIOLOGICAL SCIENCES↗

Column Number Density Expressions Through M = 0 and M = 1 Point Source Plumes Along Any Straight Path

Providers of payloads carried aboard the International Space Station must conduct analyses to demonstrate that any planned gaseous venting events generate no more than a certain level of material that may interfere with optical measurements from other experiments or payloads located nearby. This requirement is expressed in terms of a maximum column number density (CND). Depending on the level of rarefaction, such venting may be characterized by effusion for low flow rates, or by a sonic distribution at higher levels. Since the relative locations of other sensitive payloads are often unknown because they may refer to future projects, this requirement becomes a search for the maximum CND along any path.In another application, certain astronomical observations make use of CND to estimate light attenuation from a distant star through gaseous plumes, such as the Fermi Bubbles emanating from the vicinity of the black hole at the center of our Milky Way galaxy, in order to infer the amount of material being expelled via those plumes.This paper presents analytical CND expressions developed for general straight paths based upon a free molecule point source model for steady effusive flow and for a distribution fitted to model flows from a sonic orifice. Among other things, in this Mach number range it is demonstrated that the maximum CND from a distant location occurs along the path parallel to the source plane that intersects the plume axis. For effusive flows this value is exactly twice the CND found along the ray originating from that point of intersection and extending to infinity along the plumes axis. For sonic plumes this ratio is reduced to about 43.

Venting↗

Gulf of Mexico Health & Air Quality Ii: Mapping Methane Emission Plumes Using Sunglint-Configured Imagery for Monitoring Offshore Oil and Gas Activity

Offshore oil and gas production in the United States is a major source of anthropogenic greenhouse gas emissions and accounts for nearly 30% of global oil and gas production. Methane venting and flaring are primary contributors to offshore emissions, and monitoring these activities is crucial for mitigating greenhouse gas emissions. Limited ground truthing and intermittent offshore satellite revisits make monitoring venting and flaring challenging. The Bureau of Ocean Energy Management (BOEM) and the Bureau of Safety and Environmental Enforcement (BSEE) oversee offshore oil and gas activity but rely primarily on operator-reported data. The non-profit organization SkyTruth monitors natural resources like methane and identifies sources of fugitive emissions. By combining BOEM and BSEE’s operational data along with observations from Sentinel-2 Multispectral Instrument (MSI), Landsat 8 Operational Land Imager (OLI) and Landsat 9 OLI-2, and PRecursore IperSpettrale della Missione Applicativa (PRISMA), the team further identified ultra-emitter point sources in the Gulf of Mexico using sunglint-configured imagery. We quantified these plume emission rates using the methodology from Varon et al. (2020). The team found three plumes in the Gulf of Mexico occurring between 2020 and 2022 using Sentinel-2 MSI and Landsat 9 OLI-2 imagery, in addition to the single plume identified by the Gulf of Mexico Health & Air Quality I team, and successfully quantified three plumes. Our statistical retrieval of three PRISMA images tasked over areas of interest yielded no methane plumes, despite a successful test of a known plume in Assam, India. These analyses serve as a proof of concept for the utility of remote sensing for methane emission monitoring offshore, which can complement regulator emission inventories and validate self-reported operator records.

sunglint↗

Cookoff of Black Powder and Smokeless Powder

We have completed a series of both vented and sealed cookoff experiments of black powder and smokeless powder in our Sandia Instrumented Thermal Ignition (SITI) apparatus at bulk densities of 1078 and 729 kg/m 3 , respectively. The confining aluminum cylinder was ramped from room temperature to a set point temperature and then held at the setpoint temperature until ignition. The setpoint temperatures varied between 495 to 523 K for the black powder and 401 to 412 K for the more sensitive smokeless powder. The vented experiments show a significant delay in thermal ignition, indicating that the ignition is dependent on pressure. Post experimental debris shows greater violence for our smokeless powder experiments than our black powder experiments. A simplified universal cookoff model (UCM) was calibrated using the black powder and smokeless powder SITI data and used to predict pressurization and thermal ignition. The current work presents the first calibration of the UCM with a double base propellant. Finally, this work also presents the first pressure-dependent cookoff model for black powder and smokeless powder.

42 ENGINEERING↗

Environmental Constraints that Limit Methanogenesis

Methanogens are active in many different ecosystems, including habitats with biologically-derived organic matter as substrates such as aquatic sediments, wetlands, agricultural or natural soils subject to inundation, sewage digesters, and the anoxic portions of animal digestive tracts. Methanogens are also present in habitats with geochemically-supplied substrates such as hot springs, hydrothermal vents, volcanically-influenced habitats, and, potentially, the deep crustal subsurface. Methanogens as a group tolerate a broad range of physicochemical conditions, including temperatures from -2 to 122°C, pH values of 3.0 to 10.2, salinities up to halite saturation, and pressures of at least 75 MPa. Globally, variations in methane emissions can be explained to a large degree by variations in temperature and water availability. The distribution and activity of methanogens are constrained by ecological interactions that can be stimulatory or competitive, and by physicochemical factors that act at the biochemical or bioenergetic levels. In addition to the constraints placed on methanogens by physicochemical extremes, methanogen distribution and activity are constrained by the availability of energy and nutrients, the presence of inhibitory molecules (most notably oxygen), and the seawater anion, sulfate, due to competitive ecological interactions. Although methanogen tolerances to individual extremes are documented in culture, and the corresponding biochemical adaptations are understood to varying degrees, the natural environment frequently presents combinations of extreme conditions and energy limitations that may limit methanogen distribution to less than the optimally tolerated range of a single parameter. Little is understood about the compound effects of such extremes, nor the commonalities among them that will ultimately form the basis for predictive models of environmental methanogen population distribution. Future work that targets these questions, through a combination of culture work, “omic” analyses, in situ studies, and conceptual and quantitative models, will be needed to better understand the physiological ecology of methanogens.

54 ENVIRONMENTAL SCIENCES↗

Ascent and emplacement dynamics of obsidian lavas inferred from microlite textures

Here, to assess the eruption and emplacement of volumetrically diverse rhyolite lavas, we measured microlite number densities and orientations from samples collected from nine lavas in Yellowstone Caldera and two from Mono Craters, USA. Microlite populations are composed of Fe-Ti oxides ± alkali feldspar ± clinopyroxene. Number densities range from 10 8.11 ± 0.03 to 10 9.45 ± 0.15 cm -3 and do not correlate with distance from the vent across individual flows and are remarkably similar between large- and small-volume lavas. Together, those observations suggest that number densities are unmodified during emplacement and that ascent rates in the conduit are similar between small domes and large lava flows. Microtextures produced by continuous decompression experiments best replicate natural textures at decompression rates of 1–2 MPa hr -1 . Acicular microlites have a preferred orientation in all natural samples. Because the standard deviation of microlite orientation does not become better aligned with distance travelled, we conclude that microlites exit the conduit aligned and that strain during subaerial flow was insufficient to further align microlites. The orientations of microlite trend and plunge in near-vent samples indicate that pure shear was the dominant style of deformation in the conduit. In conclusion, we speculate that collapsing permeable foam(s) provides a mechanism to concurrently allow microlite formation and alignment in response to the combination of degassing and flattening by pure shear.

58 GEOSCIENCES↗

Mechanical response and microprocesses of reconsolidating crushed salt at elevated temperature

Design, analysis and performance assessment of potential salt repositories for heat-generating nuclear waste require knowledge of thermal, mechanical, and fluid transport properties of reconsolidating granular salt. So, to inform salt repository evaluations, we have undertaken an experimental program to determine Bulk and Young’s moduli and Poisson’s ratio of reconsolidated granular salt as a function of porosity and temperature and to establish the deformational processes by which the salt reconsolidates. Our tests were conducted at 100, 175, and 250 °C. In hydrostatic tests, confining pressure is increased to 20 MPa with periodic unload/reload loops to determine K. Volume strain increases with increasing temperature. In shear tests at 2.5 and 5 MPa confining pressure, after confining pressure is applied, the crushed salt is subjected to a differential stress, with periodic unload/reload loops to determine E and ν. At predetermined differential stress levels the stress is held constant and the salt consolidates. Displacement gages mounted on the samples show little lateral deformation until the samples reach a porosity of ~10 %. Interestingly, vapor is vented only for 250 °C tests and condenses at the vent port. It is hypothesized that the brine originates from fluid inclusions, which were made accessible by heating and intragranular deformational processes including decrepitation. Furthermore, identification and documentation of consolidation processes are inferred from optical and scanning electron microstructural observations. As a result, densification at low porosity is enhanced by water film on grain boundaries that enables solution-precipitation phenomena.

58 GEOSCIENCES↗

Cost minimization of deoxygenation for control of Vampirovibrio chlorellavorus in Chlorella sorokiniana cultures

Deoxygenation is a strategy for preventing Vampirovibrio chlorellavorus infection of Chlorella sorokiniana cultures. Deoxygenation cost was minimized by sparging with nitrogen gas for only one hour at the onset of night and relying on naturally-occurring dark-respiration to maintain low oxygen concentrations throughout the night. This technique substantially reduced V. chlorellavorus infection in laboratory co-cultures. The cost of the approach was evaluated in outdoor experiments with one pure water and one pathogen-free C. sorokiniana culture, grown in a 150-L sealed, vented, translucent-polyethylene reactor. Unlike the small laboratory reactors, which were also sealed and vented, the much larger outdoor reactor maintained the dissolved oxygen concentration in the C. sorokiniana culture at near zero concentration throughout the night cycle. This demonstrates that large covered tanks in commercial applications would keep oxygen concentration near zero for the entire night. The total nitrogen sparged, per night, per liter of algal culture, was determined for the 150-L reactor, and used to estimate the cost per m2 for large scale raceways. Onsite nitrogen generators are the most cost-effective method to supply a high flow of nitrogen gas to commercial scale raceways. The cost of deoxygenation treatment ranged from $16/ton AFDW algae for a shallow (2 cm) gravity flow system with 75% harvest prior to deoxygenation to over $1,300/ton for a 20 cm depth raceway with plastic tanks.

59 BASIC BIOLOGICAL SCIENCES↗

Large deformation and gas retention during cookoff of a plastic bonded explosive (PBX 9407)

Here, we have used several configurations of the Sandia Instrumented Thermal Ignition (SITI) experiment to develop a pressure-dependent, four-step ignition model for a plastic bonded explosive (PBX 9407) consisting of 94 wt.% RDX (hexahydro-1,3,5-trinitro-1,3,5-triazine), and a 6 wt.% VCTFE binder (vinyl chloride/chlorotrifluoroethylene copolymer). The four steps include desorption of water, decomposition of RDX to form equilibrium products, pressure-dependent decomposition of RDX forming equilibrium products, and decomposition of the binder to form hydrogen chloride and a nonvolatile residue (NVR). We address drying, binder decomposition, and decomposition of the RDX component from the pristine state through the melt and into ignition. We used Latin Hypercube Sampling (LHS) of the parameters to determine the sensitivity of the model to variation in the parameters. We also successfully validated the model using one-dimensional time-to-explosion (ODTX and P-ODTX) data from a different laboratory. Our SITI test matrix included 1) different densities ranging from 0.7 to 1.63 g/cm 3 , 2) free gas volumes ranging from 1.2 to 38 cm 3 , and 3) boundary temperatures ranging from 170 to 190 °C. We measured internal temperatures using embedded thermocouples at various radial locations as well as pressure using tubing that was connected from the free gas volume (ullage) to a pressure gauge. We also measured gas flow from our vented experiments. A borescope was included to obtain in situ video during some SITI experiments. We observed significant changes in the explosive volume prior to ignition. Our model, in conjunction with data observations, imply that internal accumulation of decomposition gases in high density PBX 9407 (90% of the theoretical maximum density) can contribute to significant strain whether or not the experiment is vented or sealed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cookoff experiments of a melt cast explosive (Comp-B3)

Validated models of melt cast explosives exposed to accidental fires are essential for safety analysis. In the current work, we provide several experiments that can be used to develop and validate cookoff models of melt cast explosives such as Comp-B3 composed of 60:40 wt% RDX:TNT. We present several vented and sealed experiments from 2.5 mg to 4.2 kg of Comp-B3 in several configurations. We measured pressure, spatial temperature, and ignition time. Some experiments included borescope images obtained during both vented and sealed decomposition. We observed the TNT melt, the suspension of RDX particles in the melt, bubble formation caused by RDX decomposition, and bubble-induced mixing of the suspension. The RDX suspension did not completely dissolve, even as temperatures approached ignition. Our results contrast with published measurements of RDX solubility in hot TNT that suggest RDX would be completely dissolved at these high temperatures. These different observations are attributed to sample purity. We did not observe significant movement of the two-phase mixture until decomposition gases formed bubbles. Bubble generation was inhibited in our sealed experiments and suppressed mixing.

42 ENGINEERING↗

PERCOLATION ON GRAIN BOUNDARY NETWORKS: APPLICATION TO FISSION GAS RELEASE IN NUCLEAR FUELS

The percolation behavior of grain boundary networks is characterized in two- and three-dimensional lattices with circular macroscale cross-sections that correspond to nuclear fuel elements. The percolation of gas bubbles on grain boundaries, and the subsequent percolation of grain boundary networks is the primary mechanism of fission gas release from nuclear fuels. Both radial cracks and radial gradients in grain boundary property distributions are correlated with the fraction of grain boundaries vented to the free surfaces. Our results show that cracks surprisingly do not significantly increase the percolation of uniform grain boundary networks. However, for networks with radial gradients in boundary properties, the cracks can considerably raise the vented grain boundary content.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Micromechanical processes in consolidated granular salt

Here, granular salt is likely to be used as backfill material and a seal system component within geologic salt formations serving as a repository for long-term isolation of nuclear waste. Pressure from closure of the surrounding salt formation will promote consolidation of granular salt, eventually resulting in properties comparable to native salt. Understanding dependence of consolidation processes on stress state, moisture availability, temperature, and time is important for demonstrating sealing functions and long-term repository performance. This study characterizes laboratory-consolidated granular salt by means of microstructural observations. Granular salt material from mining operations was obtained from the bedded Salado Formation hosting the Waste Isolation Pilot Plant and the Avery Island salt dome. Laboratory test conditions included hydrostatic consolidation of jacketed granular salt with varying conditions of confining isochoric stress to 38 MPa, temperature to 250 °C, moisture additions of 1% by weight, time duration, and vented and non-vented states. Resultant porosities ranged between 1% and 22%. Optical and scanning electron microscopic techniques were used to ascertain consolidation mechanisms. From these investigations, samples with 1% added moisture or unvented during consolidation, exhibit clear pressure solution processes with tightly cohered grain boundaries and occluded fluid pores. Samples with only natural moisture content consolidated by a combination of brittle, cataclastic, and crystal plastic deformation. Recrystallization at 250 °C irrespective of moisture conditions was also observed. The range and variability of conditions applied in this study, combined with the techniques used to display microstructural features, are unique, and provide insight into an important area of governing deformation mechanism(s) occurring within salt repository applications.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Resilient design in nuclear energy: Critical lessons from a cross-disciplinary analysis of the Fukushima Dai-ichi nuclear accident

This paper presents a multidisciplinary analysis of the Fukushima Dai-ichi Nuclear Power Plant accident. Along with the latest observations and simulation studies, we synthesize the time-series and event progressions during the accident across multiple disciplines, including in-plant physics and engineering systems, operators’ actions, emergency responses, meteorology, radionuclide release and transport, land contamination, and health impacts. We identify three key factors that exacerbated the consequences of the accident: (1) the failure of Unit 2 containment venting, (2) the insufficient integration of radiation measurements and meteorology data in the evacuation strategy, and (3) the limited risk assessment and emergency preparedness. We conclude with new research and development directions to improve the resilience of nuclear energy systems and communities, including (1) meteorology-informed proactive venting, (2) machine learning-enabled adaptive evacuation zones, and (3) comprehensive risk-informed emergency planning while leveraging the experience from responses to other disasters.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗