Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Usability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Modeling Nanosecond-Pulsed Spark Discharge and Flame Kernel Evolution

Dilute combustion, either using exhaust gas recirculation or with excess air, is considered a promising strategy to improve the thermal efficiency of internal combustion engines. However, the dilute air-fuel mixture, especially under intensified turbulence and high-pressure conditions, poses significant challenges for ignitability and combustion stability, which may limit the attainable efficiency benefits. In-depth knowledge of the flame kernel evolution to stabilize ignition and combustion in a challenging environment is crucial for effective engine development and optimization. To date, a comprehensive understanding of ignition processes that result in the development of fully predictive ignition models usable by the automotive industry does not yet exist. Spark-ignition consists of a wide range of physics that includes electrical discharge, plasma evolution, joule-heating of gas, and flame kernel initiation and growth into a self-sustainable flame. In this study, an advanced approach is proposed to model spark-ignition energy deposition and flame kernel growth. To decouple the flame kernel growth from the electrical discharge, a nanosecond-pulsed high-voltage discharge is used to trigger spark-ignition in an optically accessible small ignition test vessel with a quiescent mixture of air and methane. Initial conditions for the flame kernel, including its thermodynamic state and species composition, are derived from a plasma-chemical equilibrium calculation. The geometric shape and dimension of the kernel are characterized using a multi-dimensional thermal plasma solver. Here, the proposed modeling approach is evaluated using a high-fidelity computational fluid dynamics procedure to compare the simulated flame kernel evolution against flame boundaries from companion Schlieren images.

42 ENGINEERING↗

Methods for Estimating Hydrogen Fuel Tank Characteristics

The pressure vessels needed to store hydrogen for next-generation hydrogen fuel cell vehicles are expected to be a substantial portion of the total system mass, volume, and cost. Gravimetric capacity, volumetric capacity, and cost per kilogram of usable hydrogen are key performance metrics that the U.S. Department of Energy (DOE) uses to determine the viability of hydrogen fuel cell systems. Research and development related to hydrogen storage systems covers a wide range of potential operating conditions, from cryogenic temperatures to high temperatures (above ambient) and low pressure to high pressure. Researchers at PNNL have developed methods for estimating these key pressure vessel characteristics to support on-board hydrogen storage system design and performance evaluation and to support decision-making about DOE hydrogen storage system research investments. This article describes the pressure tank estimation methodology that has been used as a stand-alone calculation and has been incorporated into larger system evaluation tools. The methodology estimates the geometry, mass, and material cost of type I, type III, and type IV pressure vessels based on operating pressure and material strength at the system's operating temperature, using classical thin-wall and thick-wall pressure vessel stress calculations. The geometry, mass, and material cost requirements of the pressure vessel have significant impacts on the total system performance. For example, hydrogen storage materials that can separately achieve a very high hydrogen density can be deemed impractical for use in fuel cell vehicle hydrogen storage systems because the pressure tank containing them is too large, heavy, or expensive. This article describes the design philosophy and analytical process of the tank characteristic estimation methodology, which has been implemented in spreadsheet calculation tools and system-level analysis tools used by DOE researchers. Each of the three tank types (type I, type III, and type IV) uses a different analysis methodology with some common elements. This article also provides examples of implementing the methodology to perform parametric studies of all three pressure vessel types. The goal of this article is to present the methodology in sufficient detail so it can be implemented in other hydrogen fuel cell vehicle design and analysis tools.

42 ENGINEERING↗

Experimental Combustion and Flame Characterization of a Chemical Looping-Based Oxidative Dehydrogenation Byproduct Fuel Mixture Containing High CO2 Dilution

Abstract This study investigates the combustion performance of a CO2-rich fuel mixture containing ethane and methane as active species using a constant volume combustion chamber. This fuel is obtained as a byproduct of a chemical looping-based oxidative dehydrogenation (Cl-ODH) process ethylene production. The byproduct gas mixture has 40.79% CO2, 39.49% ethane, and 4.88% methane by weight with other minor compounds. Using this fuel for energy extraction would improve the process efficiency of the ethane to ethylene conversion. After initial combustion modeling, the gas fuel mixture was reduced to just the major species: CO2, ethane, and methane. The mixture was then tested for flammability limits and combustion performance under spark-ignition conditions. Effects of ambient conditions like temperatures between 300 and 400 K with initial pressures from 1 to 10 bar were tested. The effects of stoichiometry were tested to understand flame velocities and heat release. The fuel mixture showed an overall reduced flame velocity compared to gasoline. Instability in combustion was believed to be caused by the dissociation of ethane under elevated conditions. At higher pressures, the flame produces lower cumulative heat release. Simulations were also performed using a model tuned to replicate the operations of the combustion chamber used in the experiments. Heat release and unburnt fuel mass data were calculated to identify the discrepancies in the combustion completeness at elevated pressures. The effects of CO2 quenching the flame coupled with the increased dissociation of the fuel species can lead to up to more than 75% of the fuel mixture being unburnt. Data from this study were used to modify a small-scale spark-ignition engine to use this fuel and produce usable energy.

Energy & Fuels↗

Exploring Electrode-Level State-of-Charge and State-of-Health Dynamics in Lithium-Ion Battery Cells: Modeling and Experimental Identification

A computationally efficient model serves as a critical prerequisite for battery performance analysis and advanced battery management algorithm design. Although battery models that capture cell-level behavior have been widely explored in existing literature, electrode-level battery models have received much lesser attention till to date. However, such electrode-level models can significantly increase battery performance and life by enabling electrode-level health-conscious control. Such electrode-level control can effectively expand usable energy and power limits of the battery cells by utilizing the knowledge of individual electrodes' charge and health. In this context, this paper presents a comprehensive battery model developed with a reference electrode insertion that captures (i) electrode-level charge/discharge dynamics, (ii) stoichiometric and temporal dependencies of electrode-level resistances, (iii) solid electrolyte interface (SEI) layer growth as key degradation phenomenon, and (iv) capacity fade and resistance rise in each electrode due to nominal battery aging. The proposed model is identified, and a preliminary validation is performed utilizing terminal voltage and negative electrode potential data collected from a pouch cell under one continuous cycling and accelerated aging conditions where the cell experienced 14% capacity loss.

aging↗

Application of Sol-Gel Method as a Protective Layer on a Specular Reflective Surface for Secondary Reflector in a Solar Receiver

Highly-specular reflective surfaces that can withstand elevated-temperatures are desirable for many applications including reflective heat shielding in solar receivers and secondary reflectors, which can be used between primary concentrators and heat collectors. A high-efficiency, high-temperature solar receiver design based on arrays of cavities needs a highly-specular reflective surface on its front section to help sunlight penetrate into the absorber tubes for effective flux spreading. Since this application is for high-temperature solar receivers, this surface needs to be durable and to maintain its optical properties through the usable life. Degradation mechanisms associated with elevated temperatures and thermal cycling, which include cracking, delamination, corrosion/oxidation, and environmental effects, could cause the optical properties of surfaces to degrade rapidly in these conditions. Protected mirror surfaces for these applications have been tested by depositing a thin layer of SiO2 on top of electrodeposited silver by means of the sol-gel method. To obtain an effective thin film structure, this sol-gel procedure has been investigated extensively by varying process parameters that affect film porosity and thickness. Endurance tests have been performed in a furnace at 150 degrees C for thousands of hours. This paper presents the sol-gel process for intermediate-temperature specular reflective coatings and provides the long-term reliability test results of sol-gel protected silver-coated surfaces.

14 SOLAR ENERGY↗

Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ~3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ~5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ~4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. Finally, we also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

36 MATERIALS SCIENCE↗

Raytracing the long trace profiler

The optical design of the Long Trace Profiler optical system is explored with a commercial raytrace program, Zemax OpticStudio™ (ZOS)1, with the intent of finding and correcting sources of systematic error. ZOS provides both geometric raytracing tools and physical optics Gaussian beam propagation and diffraction image calculation tools, and two design modes, sequential component (SC) and non-sequential component (NSC) that are optimized for different aspects of the design process. The original LTP-II system employs a singlet lens with a 1250 mm focal length. It is optimized to provide minimum distortion over a surface slope angle range of ±5 mrad. Using the ZOS tools, we are able to simulate ghost rays that produce distortion in the beam spot image and can minimize the distortion by deliberate misalignment of the beamsplitter (BS) components. Unfortunately, the reference beam is compromised because of the component tilts. The most recent LTP500 system design simplifies the optical system and makes the reference beam usable again, even with misalignment of the polarizing beamsplitter (PBS). Two lenses are designed for the LTP500 - a cemented doublet that has been fabricated, and a singlet with one aspheric surface. Both have focal distances of 500 mm with an expanded angular measurement range of ±10 mrad. The aspheric singlet provides superior performance. ZOS allows the import of wavefront measurement data produced by commercial interferometer software. We apply the wavefront error measurement from the cemented doublet to the model to show that the 19nm RMS wavefront error needs to be improved by at least a factor of ten in order to reduce the systematic error to a level that will allow the LTP to approach its design limit of a few tens of nanoradians.

Takacs, Peter Z.↗

Self-assessed performance improves statistical fusion of image labels

Purpose: Expert manual labeling is the gold standard for image segmentation, but this process is difficult, time-consuming, and prone to inter-individual differences. While fully automated methods have successfully targeted many anatomies, automated methods have not yet been developed for numerous essential structures (e.g., the internal structure of the spinal cord as seen on magnetic resonance imaging). Collaborative labeling is a new paradigm that offers a robust alternative that may realize both the throughput of automation and the guidance of experts. Yet, distributing manual labeling expertise across individuals and sites introduces potential human factors concerns (e.g., training, software usability) and statistical considerations (e.g., fusion of information, assessment of confidence, bias) that must be further explored. During the labeling process, it is simple to ask raters to self-assess the confidence of their labels, but this is rarely done and has not been previously quantitatively studied. Herein, the authors explore the utility of self-assessment in relation to automated assessment of rater performance in the context of statistical fusion. Methods: The authors conducted a study of 66 volumes manually labeled by 75 minimally trained human raters recruited from the university undergraduate population. Raters were given 15 min of training during which they were shown examples of correct segmentation, and the online segmentation tool was demonstrated. The volumes were labeled 2D slice-wise, and the slices were unordered. A self-assessed quality metric was produced by raters for each slice by marking a confidence bar superimposed on the slice. Volumes produced by both voting and statistical fusion algorithms were compared against a set of expert segmentations of the same volumes. Results: Labels for 8825 distinct slices were obtained. Simple majority voting resulted in statistically poorer performance than voting weighted by self-assessed performance. Statistical fusion resulted in statistically indistinguishable performance from self-assessed weighted voting. The authors developed a new theoretical basis for using self-assessed performance in the framework of statistical fusion and demonstrated that the combined sources of information (both statistical assessment and self-assessment) yielded statistically significant improvement over the methods considered separately. Conclusions: The authors present the first systematic characterization of self-assessed performance in manual labeling. The authors demonstrate that self-assessment and statistical fusion yield similar, but complementary, benefits for label fusion. Finally, the authors present a new theoretical basis for combining self-assessments with statistical label fusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Free software for performing physical analysis of systems for digital radiography and mammography

Purpose: In this paper, the authors present a free software for assisting users in achieving the physical characterization of x-ray digital systems and image quality checks. Methods: The program was developed as a plugin of a well-known public-domain suite ImageJ. The software can assist users in calculating various physical parameters such as the response curve (also termed signal transfer property), modulation transfer function (MTF), noise power spectra (NPS), and detective quantum efficiency (DQE). It also includes the computation of some image quality checks: defective pixel analysis, uniformity, dark analysis, and lag. Results: The software was made available in 2009 and has been used during the last couple of years by many users who gave us valuable feedback for improving its usability. It was tested for achieving the physical characterization of several clinical systems for digital radiography and mammography. Various published papers made use of the outcomes of the plugin. Conclusions: This software is potentially beneficial to a variety of users: physicists working in hospitals, staff working in radiological departments, such as medical physicists, physicians, engineers. The plugin, together with a brief user manual, are freely available and can be found online ( http://www.medphys.it/downloads.htm ). With our plugin users can estimate all three most important parameters used for physical characterization (MTF, NPS, and also DQE). The plugin can run on any operating system equipped with ImageJ suite. The authors validated the software by comparing MTF and NPS curves on a common set of images with those obtained with other dedicated programs, achieving a very good agreement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-E-01: ABR Diagnostic Radiology Core Exam: Was Our Redesigned Physics Course Successful in Teaching Physics to Radiology Residents?

Purpose: Our purpose is to evaluate the effectiveness of our two year physics course in preparing radiology residents for the American Board of Radiology (ABR) diagnostic radiology exam. Methods: We designed a new two-year physics course that integrates radiology clinical content and practice and is primarily based on the AAPM curriculum and RSNA/AAPM physics modules. Biweekly classes focus on relevant concepts from assigned reading and use audience response systems to encourage participation. Teaching efficiency is optimized through lecturer rotations of physicists, radiologists, and guest speakers. An emphasis is placed on clinical relevance by requiring lab work and providing equipment demonstrations. Periodic quiz were given during the course. The course website was also redesigned for usability, and physics review lectures were conducted two weeks before the board exam to refresh key concepts. At the completion of our first two-year course, we conducted a confidential evaluation of the faculty and course. The evaluation assessed metrics such as overall organization, clinical relevance of content, and level of difficulty, with a rating scale from poor to excellent. Results: Our evaluation indicated that the redesigned course provided effective board exam preparation, with most responses between good and excellent. There was some criticism on the course length and on chronological discontinuity, but the review lectures were appreciated by the residents. All of our residents passed the physics component of the ABR exam with scores exceeding the minimum passing score by a significant margin. Conclusion: The course evaluation and board exam results indicate that our new two-year course format provides valuable board exam preparation. This is possible thanks to the time and effort taken by the physics faculty on ensuring the residents get quality physics education.

60 APPLIED LIFE SCIENCES↗

SU-E-J-141: Comparison of Dose Calculation On Automatically Generated MRBased ED Maps and Corresponding Patient CT for Clinical Prostate EBRT Plans

Purpose: To analyze the effect of computing radiation dose on automatically generated MR-based simulated CT images compared to true patient CTs. Methods: Six prostate cancer patients received a regular planning CT for RT planning as well as a conventional 3D fast-field dual-echo scan on a Philips 3.0T Achieva, adding approximately 2 min of scan time to the clinical protocol. Simulated CTs (simCT) where synthesized by assigning known average CT values to the tissue classes air, water, fat, cortical and cancellous bone. For this, Dixon reconstruction of the nearly out-of-phase (echo 1) and in-phase images (echo 2) allowed for water and fat classification. Model based bone segmentation was performed on a combination of the DIXON images. A subsequent automatic threshold divides into cortical and cancellous bone. For validation, the simCT was registered to the true CT and clinical treatment plans were re-computed on the simCT in pinnacle{sup 3}. To differentiate effects related to the 5 tissue classes and changes in the patient anatomy not compensated by rigid registration, we also calculate the dose on a stratified CT, where HU values are sorted in to the same 5 tissue classes as the simCT. Results: Dose and volume parameters on PTV and risk organs as used for the clinical approval were compared. All deviations are below 1.1%, except the anal sphincter mean dose, which is at most 2.2%, but well below clinical acceptance threshold. Average deviations are below 0.4% for PTV and risk organs and 1.3% for the anal sphincter. The deviations of the stratifiedCT are in the same range as for the simCT. All plans would have passed clinical acceptance thresholds on the simulated CT images. Conclusion: This study demonstrated the clinical usability of MR based dose calculation with the presented Dixon acquisition and subsequent fully automatic image processing. N. Schadewaldt, H. Schulz, M. Helle and S. Renisch are employed by Phlips Technologie Innovative Techonologies, a subsidiary of Royal Philips NV.

60 APPLIED LIFE SCIENCES↗

SU-E-T-196: Heat Diffusion Modeling for Digital Holographic Interferometry Dosimetry

Purpose: We have previously demonstrated that with Digital Holographic Interferometry (DHI) 2D spatial calorimetric measurements of high dose rate radiation sources can be obtained. The impact of heat transfer must be considered when undertaking any form of calorimetric measurement, as the radiation induced temperature distributions are subject to degradation due to heat diffusion. Unaccounted for, this limits the accuracy of the approach especially for long delivery times. Methods: 3D modelling of the heat diffusion in water was undertaken, and two different approaches developed to account for this effect. The mathematical framework to describe heat diffusion in 3D was applied, with the differential equations solved numerically using an implicit method. The first approach involved the comparison of the DHI measurements to an independent dose model of the source. The model was forward modeled to account for the heat diffusion during irradiation, allowing a direct comparison to validate the measured results. The second approach involved the correction of the measured data directly, by comparing the temperature distribution of two instances and subtracting the effects of heat diffusion of the first distribution from the second instance. This required the use of the Abel transform to approximate the 3D dose distribution from the 2D DHI results, thus limiting the approach to radiation applications possessing cylindrical symmetry. Results: The first approach resulted in higher accuracy and was more straightforward, but has a major limitation in that the measured results are only able to be utilized in comparison with an independent dose model. The applicability of the second approach is affected by noise in the measurement data and introduces higher uncertainties, but results in higher usability of the final data. Conclusion: Both approaches were implemented, and if used in conjunction would provide the most utility for the interpretation and use of DHI measurements.

07 ISOTOPE AND RADIATION SOURCES↗

TU-A-BRD-01: Outcomes of Hypofractionated Treatments - Initial Results of the WGSBRT

Stereotactic Body Radiation Therapy (SBRT) has emerged in recent decades as a treatment paradigm that is becoming increasingly important in clinical practice. Clinical outcomes data are rapidly accumulating. Although published relations between outcomes and dose distributions are still sparse, the field has progressed to the point where evidence-based normal tissue dose-volume constraints, prescription strategies, and Tumor Control Probability (TCP) and Normal Tissue Complication Probability (NTCP) models can be developed. The Working Group on SBRT (WGSBRT), under the Biological Effects Subcommittee of AAPM, is a group of physicists and physicians working in the area of SBRT. It is currently performing critical literature reviews to extract and synthesize usable data and to develop guidelines and models to aid with safe and effective treatment. The group is investigating clinically relevant findings from SBRT in six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session of AAPM 2014, interim results are presented on TCP for lung and liver, NTCP for thoracic organs, and radiobiological foundations:• Lung TCP: Detailed modeling of TCP data from 118 published studies on early stage lung SBRT investigates dose response and hypothesized mechanisms to explain the improved outcomes of SBRT. This is presented from the perspective of a physicist, a physician, and a radiobiologist.• Liver TCP: For primary and metastatic liver tumors, individual patient data were extracted from published reports to examine the effects of biologically effective dose on local control.• Thoracic NTCP: Clinically significant SBRT toxicity of lung, rib / chest wall and other structures are evaluated and compared among published clinical data, in terms of risk, risk factors, and safe practice.• Improving the clinical utility of published toxicity reports from SBRT and Hypofractionated treatments. What do we want, and how do we get it? Methods and problems of synthesizing data from published reports. Learning Objectives: Common SBRT fractionation schemes and current evidence for efficacy. Evidence for normal tissue tolerances in hypofractionated treatments. Clinically relevant radiobiological effects at large fraction sizes.

60 APPLIED LIFE SCIENCES↗

TH-C-19A-05: Evaluation of a New Reusable 3D Dosimeter

Purpose: PRESAGE is a radiochromic plastic which has demonstrated strong potential for high resolution single-use 3D dosimetry. This study evaluates a new PRESAGE formulation (Presage-RU) in which the radiochromic response is reversible (the dosimeter optically clears after irradiation), enabling the potential for reusability. Methods: Presage-RU dose response and optical-clearing rates were evaluated in both small volume dosimeters (1×1×4.5cm) and a larger cylindrical dosimeter (8cm diameter, 4.5cm length). All dosimeters were allowed to fully optically clear in dark, room temperature conditions between irradiations. Dose response was determined by irradiating small volume samples from 0–8.0Gy and measuring change in optical density. The cylindrical dosimeter was irradiated with a simple 4-field box plan (parallel opposed pairs of 4cm×4cm AP-PA beams and 2cm×4cm lateral beams) to 20Gy. High resolution 3D dosimetry was achieved utilizing optical-CT readout. Readings were tracked up to 14 days to characterize optical clearing. Results: Initial irradiation yielded a response of 0.0119△OD/(Gy*cm) while two subsequent reirradiations yielded a lower but consistent response of 0.0087△OD/(Gy*cm). Strong linearity of dose response was observed for all irradiations. In the large cylindrical dosimeter, the integral dose within the high dose region exhibited an exponential decay in signal over time (halflife= 23.9 hours), with the dosimeter effectively cleared (0.04% of the initial signal) after 10 days. Subsequent irradiation resulted in 19.5% lower initial signal but demonstrated that the exponential clearing rate remained consistent. Results of additional subsequent irradiations will also be presented. Conclusion: This work introduces a new re-usable radiochromic dosimeter (Presage-RU) compatible with high resolution (sub-millimeter) 3D dosimetry. Sensitivity of the initial radiation was observed to be slightly higher than subsequent irradiations, but the clearing time remained constant, indicating the dosimeter can be re-used after 10 days. Presage-RU has potential to dramatically improve cost-effectiveness and thereby lower the barrier for implementing comprehensive, high resolution 3D dosimetry. John Adamovics is the president of Heuris Inc., which commercializes PRESAGE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a 6DOF robotic motion phantom for radiation therapy

Purpose: The use of medical technology capable of tracking patient motion or positioning patients along 6 degree-of-freedom (6DOF) has steadily increased in the field of radiation therapy. However, due to the complex nature of tracking and performing 6DOF motion, it is critical that such technology is properly verified to be operating within specifications in order to ensure patient safety. In this study, a robotic motion phantom is presented that can be programmed to perform highly accurate motion along any X (left–right), Y (superior–inferior), Z (anterior–posterior), pitch (around X), roll (around Y), and yaw (around Z) axes. In addition, highly synchronized motion along all axes can be performed in order to simulate the dynamic motion of a tumor in 6D. The accuracy and reproducibility of this 6D motion were characterized. Methods: An in-house designed and built 6D robotic motion phantom was constructed following the Stewart–Gough parallel kinematics platform archetype. The device was controlled using an inverse kinematics formulation, and precise movements in all 6 degrees-of-freedom (X, Y, Z, pitch, roll, and yaw) were performed, both simultaneously and separately for each degree-of-freedom. Additionally, previously recorded 6D cranial and prostate motions were effectively executed. The robotic phantom movements were verified using a 15 fps 6D infrared marker tracking system and the measured trajectories were compared quantitatively to the intended input trajectories. The workspace, maximum 6D velocity, backlash, and weight load capabilities of the system were also established. Results: Evaluation of the 6D platform demonstrated translational root mean square error (RMSE) values of 0.14, 0.22, and 0.08 mm over 20 mm in X and Y and 10 mm in Z, respectively, and rotational RMSE values of 0.16°, 0.06°, and 0.08° over 10° of pitch, roll, and yaw, respectively. The robotic stage also effectively performed controlled 6D motions, as well as reproduced cranial trajectories over 15 min, with a maximal RMSE of 0.04 mm translationally and 0.04° rotationally, and a prostate trajectory over 2 min, with a maximal RMSE of 0.06 mm translationally and 0.04° rotationally. Conclusions: This 6D robotic phantom has proven to be accurate under clinical standards and capable of reproducing tumor motion in 6D. Such functionality makes the robotic phantom usable for either quality assurance or research purposes.

60 APPLIED LIFE SCIENCES↗

Segmentation-free empirical beam hardening correction for CT

Purpose: The polychromatic nature of the x-ray beams and their effects on the reconstructed image are often disregarded during standard image reconstruction. This leads to cupping and beam hardening artifacts inside the reconstructed volume. To correct for a general cupping, methods like water precorrection exist. They correct the hardening of the spectrum during the penetration of the measured object only for the major tissue class. In contrast, more complex artifacts like streaks between dense objects need other techniques of correction. If using only the information of one single energy scan, there are two types of corrections. The first one is a physical approach. Thereby, artifacts can be reproduced and corrected within the original reconstruction by using assumptions in a polychromatic forward projector. These assumptions could be the used spectrum, the detector response, the physical attenuation and scatter properties of the intersected materials. A second method is an empirical approach, which does not rely on much prior knowledge. This so-called empirical beam hardening correction (EBHC) and the previously mentioned physical-based technique are both relying on a segmentation of the present tissues inside the patient. The difficulty thereby is that beam hardening by itself, scatter, and other effects, which diminish the image quality also disturb the correct tissue classification and thereby reduce the accuracy of the two known classes of correction techniques. The herein proposed method works similar to the empirical beam hardening correction but does not require a tissue segmentation and therefore shows improvements on image data, which are highly degraded by noise and artifacts. Furthermore, the new algorithm is designed in a way that no additional calibration or parameter fitting is needed. Methods: To overcome the segmentation of tissues, the authors propose a histogram deformation of their primary reconstructed CT image. This step is essential for the proposed algorithm to be segmentation-free (sf). This deformation leads to a nonlinear accentuation of higher CT-values. The original volume and the gray value deformed volume are monochromatically forward projected. The two projection sets are then monomially combined and reconstructed to generate sets of basis volumes which are used for correction. This is done by maximization of the image flatness due to adding additionally a weighted sum of these basis images. sfEBHC is evaluated on polychromatic simulations, phantom measurements, and patient data. The raw data sets were acquired by a dual source spiral CT scanner, a digital volume tomograph, and a dual source micro CT. Different phantom and patient data were used to illustrate the performance and wide range of usability of sfEBHC across different scanning scenarios. The artifact correction capabilities are compared to EBHC. Results: All investigated cases show equal or improved image quality compared to the standard EBHC approach. The artifact correction is capable of correcting beam hardening artifacts for different scan parameters and scan scenarios. Conclusions: sfEBHC generates beam hardening-reduced images and is furthermore capable of dealing with images which are affected by high noise and strong artifacts. The algorithm can be used to recover structures which are hardly visible inside the beam hardening-affected regions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Latent uncertainties of the precalculated track Monte Carlo method

Purpose: While significant progress has been made in speeding up Monte Carlo (MC) dose calculation methods, they remain too time-consuming for the purpose of inverse planning. To achieve clinically usable calculation speeds, a precalculated Monte Carlo (PMC) algorithm for proton and electron transport was developed to run on graphics processing units (GPUs). The algorithm utilizes pregenerated particle track data from conventional MC codes for different materials such as water, bone, and lung to produce dose distributions in voxelized phantoms. While PMC methods have been described in the past, an explicit quantification of the latent uncertainty arising from the limited number of unique tracks in the pregenerated track bank is missing from the paper. With a proper uncertainty analysis, an optimal number of tracks in the pregenerated track bank can be selected for a desired dose calculation uncertainty. Methods: Particle tracks were pregenerated for electrons and protons using EGSnrc and GEANT4 and saved in a database. The PMC algorithm for track selection, rotation, and transport was implemented on the Compute Unified Device Architecture (CUDA) 4.0 programming framework. PMC dose distributions were calculated in a variety of media and compared to benchmark dose distributions simulated from the corresponding general-purpose MC codes in the same conditions. A latent uncertainty metric was defined and analysis was performed by varying the pregenerated track bank size and the number of simulated primary particle histories and comparing dose values to a “ground truth” benchmark dose distribution calculated to 0.04% average uncertainty in voxels with dose greater than 20% of D{sub max}. Efficiency metrics were calculated against benchmark MC codes on a single CPU core with no variance reduction. Results: Dose distributions generated using PMC and benchmark MC codes were compared and found to be within 2% of each other in voxels with dose values greater than 20% of the maximum dose. In proton calculations, a small (≤1 mm) distance-to-agreement error was observed at the Bragg peak. Latent uncertainty was characterized for electrons and found to follow a Poisson distribution with the number of unique tracks per energy. A track bank of 12 energies and 60000 unique tracks per pregenerated energy in water had a size of 2.4 GB and achieved a latent uncertainty of approximately 1% at an optimal efficiency gain over DOSXYZnrc. Larger track banks produced a lower latent uncertainty at the cost of increased memory consumption. Using an NVIDIA GTX 590, efficiency analysis showed a 807 × efficiency increase over DOSXYZnrc for 16 MeV electrons in water and 508 × for 16 MeV electrons in bone. Conclusions: The PMC method can calculate dose distributions for electrons and protons to a statistical uncertainty of 1% with a large efficiency gain over conventional MC codes. Before performing clinical dose calculations, models to calculate dose contributions from uncharged particles must be implemented. Following the successful implementation of these models, the PMC method will be evaluated as a candidate for inverse planning of modulated electron radiation therapy and scanned proton beams.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-P-26: Oncospace: A Shared Radiation Oncology Database System Designed for Personalized Medicine, Decision Support, and Research

Purpose: Advancement in Radiation Oncology (RO) practice develops through evidence based medicine and clinical trial. Knowledge usable for treatment planning, decision support and research is contained in our clinical data, stored in an Oncospace database. This data store and the tools for populating and analyzing it are compatible with standard RO practice and are shared with collaborating institutions. The question is - what protocol for system development and data sharing within an Oncospace Consortium? We focus our example on the technology and data meaning necessary to share across the Consortium. Methods: Oncospace consists of a database schema, planning and outcome data import and web based analysis tools.1) Database: The Consortium implements a federated data store; each member collects and maintains its own data within an Oncospace schema. For privacy, PHI is contained within a single table, accessible to the database owner.2) Import: Spatial dose data from treatment plans (Pinnacle or DICOM) is imported via Oncolink. Treatment outcomes are imported from an OIS (MOSAIQ).3) Analysis: JHU has built a number of webpages to answer analysis questions. Oncospace data can also be analyzed via MATLAB or SAS queries.These materials are available to Consortium members, who contribute enhancements and improvements. Results: 1) The Oncospace Consortium now consists of RO centers at JHU, UVA, UW and the University of Toronto. These members have successfully installed and populated Oncospace databases with over 1000 patients collectively.2) Members contributing code and getting updates via SVN repository. Errors are reported and tracked via Redmine. Teleconferences include strategizing design and code reviews.3) Successfully remotely queried federated databases to combine multiple institutions’ DVH data for dose-toxicity analysis (see below – data combined from JHU and UW Oncospace). Conclusion: RO data sharing can and has been effected according to the Oncospace Consortium model: http://oncospace.radonc.jhmi.edu/ . John Wong - SRA from Elekta; Todd McNutt - SRA from Elekta; Michael Bowers - funded by Elekta.

60 APPLIED LIFE SCIENCES↗