Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thermal testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Titanium Honeycomb Panel Testing

Thermal-mechanical tests were performed on a titanium honeycomb sandwich panel to experimentally validate the hypersonic wing panel concept and compare test data with analysis. Details of the test article, test fixture development, instrumentation, and test results are presented. After extensive testing to 900 deg. F, non-destructive evaluation of the panel has not detected any significant structural degradation caused by the applied thermal-mechanical loads.

Richards, W. Lance↗

An Evaluation of Pressure and Flow Measurement in the Molten Salt Test Loop (MSTL) System

The National Solar Thermal Test Facility at Sandia National Laboratories has a unique test capability called the Molten Salt Test Loop (MSTL) system. MSTL allows customers and researchers to test components in flowing, molten nitrate salt at plant-like conditions for pressure, flow, and temperature. An important need in thermal storage systems that utilize molten salts is for accurate flow and pressure measurement at temperatures above 535ÀC. Currently available flow and pressure instrumentation for molten salt is limited to 535ÀC and even at this temperature the pressure measurement appears to have significant variability. It is the design practice in current Concentrating Solar Power plants to measure flow and pressure on the cold side of the process or in dead-legs where the salt can cool, but this practice won t be possible for high temperature salt systems. For this effort, a set of tests was conducted to evaluate the use of the pressure sensors for flow measurement across a device of known flow coefficient Cv. To perform this task, the pressure sensors performance was evaluated and was found to be lacking. The pressure indicators are severely affected by ambient conditions and were indicating pressure changes of nearly 200psi when there was no flow or pressure in the system. Several iterations of performance improvement were undertaken and the pressure changes were reduced to less than 15psi. The results of these pressure improvements were then tested for use as flow measurement. It was found that even with improved pressure sensors, this is not a reliable method of flow measurement. The need for improved flow and pressure measurement at high temperatures remains and will need to be solved before it will be possible to move to high temperature thermal storage systems with molten salts.

Gill, David Dennis↗

21st Century Locomotive Technology: Quarterly Technical Status Report 28

Thermal testing of a subscale locomotive sodium battery module was initiated.to validate thermal models. The hybrid trip optimizer problem was formulated. As outcomes of this project, GE has proceeded to commercialize trip optimizer technology, and has initiated work on a state-of-the-art battery manufacturing plant for high energy density, sodium-based batteries.

25 ENERGY STORAGE↗

The X-37 Hot Structure Control Surface Testing

Thermal-structural testing of three hot structure control surface subcomponent test articles (STA) designed for the X-37 (Boeing Phantom Works, Huntington Beach, California) Orbital Vehicle (OV) has been completed. The test articles were subcomponents of the X-37 OV bodyflap and flaperon control surfaces.

Hudson, Larry D.↗

Thermal Stability of Silica for Application in Thermal Energy Storage

Thermal energy storage (TES) systems have enabled concentrating solar power (CSP) to remain competitive in the modern energy mix by providing economical load shifting grid services and firming up intermittent solar resource. Free from siting constraints, TES also shows promise as an economical alternative to traditional pumped-storage hydropower (PSH) and compressed air energy storage (CAES). As potential thermal energy storage media, some solid particles demonstrate stability over wide temperature ranges which allows for increased sensible energy storage density and is essential in achieving low-cost storage. Silica sand, in the form of a-quartz, is one such candidate. This work presents a brief review of relevant silica thermophysical properties and further investigates the thermal stability of silica particles as a candidate TES media by subjecting them to two different thermal tests: (1) a 500-hour thermal treatment at 1200 degrees C under varied atmospheres; and (2) cycling 25, 50, and 100 times between 300 degrees C and 1200 degrees C. For both tests, particle stability is examined by means of pre- and post-treatment Mie scattering. An additional XRD analysis is conducted for the 500-hour treatment in air. Results indicate limited changes in both particle distribution and crystallographic structure which is promising for the application as solid particle media for thermal energy storage.

concentrating solar power↗

Transportation Package Seal Performance in Beyond Design Basis Thermal Exposures - 12472

The Nuclear Regulatory Commission (NRC) technical report, NUREG/CR-6886, 'Spent Fuel Transportation Package Response to the Baltimore Tunnel Fire Scenario', describes, in detail, an evaluation of the potential for a theoretical release of radioactive material from three different spent nuclear fuel (SNF) transportation packages, had they been exposed to the Baltimore tunnel fire that occurred in July of 2001. This evaluation determined the temperatures of various components of the packages, including the seals, using temperatures resulting from models of the Baltimore tunnel fire (as boundary conditions) and finite element models of the SNF packages. For two of the packages evaluated, the analyses indicated that the seals used would have exceeded their continuous-use rated service temperatures, meaning the release of radioactive material could not be ruled out with available information; However, for both of the packages evaluated, the analysis determined, by a bounding calculation, that the maximum potential release was well below the regulatory requirements for releases from a SNF package during the hypothetical accident condition (HAC) sequence of events in 10CFR Part 71. The NRC is investigating the performance of seals in SNF transportation packages exposed to fires that could exceed the HAC fire described in 10CFR Part 71, such as the Baltimore Tunnel Fire that occurred in 2001. The performance of package seals is important for determining the potential release of radioactive material from a package during a beyond-design-basis accident. The seals have lower temperature limits than other package components and are the containment barrier between the environment and the cask contents. The NRC Office of Nuclear Regulatory Research contracted the National Institute of Standards and Technology (NIST) to conduct small-scale thermal testing to obtain experimental data of the performance of seals during extreme temperature exposures. The experimental testing consisted of several small-scale pressure vessels fabricated with a modified ASME flange design and tested metallic and elastomeric seals, similar to those that might be used on an actual SNF transportation package. The vessels were heated in an electrical oven to temperatures as high as 800 deg. C (1472 deg. F), exceeding the rated temperatures of the seals in question. This paper will provide a summary of the testing conducted and present test results and conclusions. Fifteen metallic and elastomeric seal performance tests including two shakedowns were performed under beyond-design-basis thermal exposure conditions; twelve tests used metallic seals, two used ethylene-propylene seals, and one used a Teflon seal. Of the five repeat metallic-seal tests (Tests No.2, 3, 4, 8, and 9), leakage (decreasing vessel pressure) was observed in three of the tests (Tests No.3, 4, and 8) during the 9 h 800 deg. C (1472 deg. F) exposure. The times when the leakage occurred (the vessel pressure started to decrease) varied in the three tests performed. The two shakedown tests were conducted using a 30 min and 4 h exposure to 800 deg. C (1472 deg. F), respectively, and the seal appeared to hold vessel pressure. No leakage (unchanged vessel pressure within the pressure measurement uncertainty) was also observed in the two metallic seal tests that used 100 deg. C incremental heating from 427 deg. C (800 deg. F) to 627 deg. C (1160 deg. F) and from 427 deg. C (800 deg. F) to 727 deg. C (1340 deg. F), respectively, with at least 9 h exposure to each temperature increment. Three repeat metallic seal tests were also conducted at the seal maximum operating temperature of 427 deg. C (800 deg. F) for 9 h. The seal maintained vessel pressure within the measurement of the pressure transducer in all three tests. No leakage was observed in one ethylene-propylene seal tested at 300 deg. C (572 deg. F) for more than 20 hours; however, leakage was found in another ethylene-propylene seal tested at 450 deg. C (842 deg. F) for more than 20 hours (Test No.15). Leakage was also observed in the test (Test No.12) that used a TFE seal subject to 300 deg. C (572 deg. F) exposure. In these fifteen tests the temperature and time exposure variables were changed to map the performance of the metallic and polymeric seals at elevated temperatures beyond the rated operating temperatures. Both the metallic and polymeric seals were able to hold pressure even after leaks were detected and no catastrophic seal failure (i.e., a rapid release of pressure to atmospheric) occurred. Further testing on the polymeric seals would need to be performed to confirm the results in these tests.(authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sprayable Phase Change Coating Thermal Protection Material

NASA has expressed a need for reusable, environmentally friendly, phase change coating that is capable of withstanding the heat loads that have historically required an ablative thermal insulation. The Space Shuttle Program currently relies on ablative materials for thermal protection. The problem with an ablative insulation is that, by design, the material ablates away, in fulfilling its function of cooling the underlying substrate, thus preventing the insulation from being reused from flight to flight. The present generation of environmentally friendly, sprayable, ablative thermal insulation (MCC-l); currently use on the Space Shuttle SRBs, is very close to being a reusable insulation system. In actual flight conditions, as confirmed by the post-flight inspections of the SRBs, very little of the material ablates. Multi-flight thermal insulation use has not been qualified for the Space Shuttle. The gap that would have to be overcome in order to implement a reusable Phase Change Coating (PCC) is not unmanageable. PCC could be applied robotically with a spray process utilizing phase change material as filler to yield material of even higher strength and reliability as compared to MCC-1. The PCC filled coatings have also demonstrated potential as cryogenic thermal coatings. In experimental thermal tests, a thin application of PCC has provided the same thermal protection as a much thicker and heavier application of a traditional ablative thermal insulation. In addition, tests have shown that the structural integrity of the coating has been maintained and phase change performance after several aero-thermal cycles was not affected. Experimental tests have also shown that, unlike traditional ablative thermal insulations, PCC would not require an environmental seal coat, which has historically been required to prevent moisture absorption by the thermal insulation, prevent environmental degradation, and to improve the optical and aerodynamic properties. In order to reduce the launch and processing costs of a reusable space vehicle to an affordable level, refurbishment costs must be substantially reduced. A key component of such a cost effective approach is the use of a reusable, phase change, thermal protection coating.

Richardson, Rod W.↗

Power Control and Monitoring Requirements for Thermal Vacuum/Thermal Balance Testing of the MAP Observatory

The specific heater control requirements for the thermal vacuum and thermal balance testing of the Microwave Anisotropy Probe (MAP) Observatory at the Goddard Space Flight Center (GSFC) in Greenbelt, Maryland are described. The testing was conducted in the 10m wide x 18.3m high Space Environment Simulator (SES) Thermal Vacuum Facility. The MAP thermal testing required accurate quantification of spacecraft and fixture power levels while minimizing heater electrical emissions. The special requirements of the MAP test necessitated construction of five (5) new heater racks.

Johnson, Chris↗

Customer interface document for the Molten Salt Test Loop (MSTL) system

The National Solar Thermal Test Facility at Sandia National Laboratories has a unique test capability called the Molten Salt Test Loop (MSTL) system. MSTL is a test capability that allows customers and researchers to test components in flowing, molten nitrate salt. The components tested can range from materials samples, to individual components such as flex hoses, ball joints, and valves, up to full solar collecting systems such as central receiver panels, parabolic troughs, or linear Fresnel systems. MSTL provides realistic conditions similar to a portion of a concentrating solar power facility. The facility currently uses 60/40 nitrate 'solar salt' and can circulate the salt at pressure up to 600psi, temperature to 585 C, and flow rate of 400-600GPM depending on temperature. The purpose of this document is to provide a basis for customers to evaluate the applicability to their testing needs, and to provide an outline of expectations for conducting testing on MSTL. The document can serve as the basis for testing agreements including Work for Others (WFO) and Cooperative Research and Development Agreements (CRADA). While this document provides the basis for these agreements and describes some of the requirements for testing using MSTL and on the site at Sandia, the document is not sufficient by itself as a test agreement. The document, however, does provide customers with a uniform set of information to begin the test planning process.

14 SOLAR ENERGY↗

Advanced Testing Method for Ground Thermal Conductivity

A new method is developed that can quickly and more accurately determine the effective ground thermal conductivity (GTC) based on thermal response test (TRT) results. Ground thermal conductivity is an important parameter for sizing ground heat exchangers (GHEXs) used by geothermal heat pump systems. The conventional GTC test method usually requires a TRT for 48 hours with a very stable electric power supply throughout the entire test. In contrast, the new method reduces the required test time by 40%–60% or more, and it can determine GTC even with an unstable or intermittent power supply. Consequently, it can significantly reduce the cost of GTC testing and increase its use, which will enable optimal design of geothermal heat pump systems. Further, this new method provides more information about the thermal properties of the GHEX and the ground than previous techniques. It can verify the installation quality of GHEXs and has the potential, if developed, to characterize the heterogeneous thermal properties of the ground formation surrounding the GHEXs.

47 OTHER INSTRUMENTATION↗

LM passive thermal design and test.

Apollo Lunar Module passive thermal control design problems solution, discussing full scale vehicle and thermal model performance test data

Bartilucci, A.↗

High-Efficiency Low-Cost Solar Receiver for Use Ina a Supercritical CO 2 Recompression Cycle

This project has performed solar receiver designs for two supercritical carbon dioxide (sCO 2 ) power cycles. The first half of the program focused on a nominally 2 MWe power cycle, with a receiver designed for test at the Sandia Solar Thermal Test Facility. This led to an economical cavity-type receiver. The second half of the program focused on a 10 MWe power cycle, incorporating a surround open receiver. Rigorous component life and performance testing was performed in support of both receiver designs. The receiver performance objectives are set to conform to the US DOE goals of 6¢/kWh by 2020 . Key findings for both cavity-type and direct open receiver are highlighted below: A tube-based absorber design is impractical at specified temperatures, pressures and heat fluxes for the application; a plate-fin architecture however has been shown to meet performance and life targets; the $148/kW th cost of the design is significantly less than the SunShot cost target with a margin of 30%; the proposed receiver design is scalable, and may be applied to both modular cavity-type installations as well as large utility-scale open receiver installations; the design may be integrated with thermal storage systems, allowing for continuous high-efficiency electrical production during off-sun hours; costs associated with a direct sCO 2 receiver for a sCO 2 Brayton power cycle are comparable to those of a typical molten salt receiver; lifetimes in excess of the 90,000 hour goal are achievable with an optimal cell geometry; the thermal performance of the Brayton receiver is significantly higher than the industry standard, and enables at least a 30% efficiency improvement over the performance of the baseline steam-Rankine boiler/cycle system; brayton’s patent-pending quartz tube window provides a greater than five-percent efficiency benefit to the receiver by reducing both convection and radiation losses.

14 SOLAR ENERGY↗

Comparing Growth Rates of Simulated Moist and Dry Convective Thermals

The spreading rates of convective thermals are linked to their net entrainment, and previous literature has suggested differences in spreading rates between moist and dry thermals. Here, growth rates of idealized numerically simulated axisymmetric dry and moist convective thermals are directly compared. In an environment with dry-neutral stratification, the increase of thermal radius with height dR / dz is a larger by a factor of 1.7 for dry thermals relative to moist thermals. The fractional change in thermal volume ε is also greater for dry thermals within a distance of ~4 radii from the initial thermal height. Values of dR / dz are nearly constant with height for both moist and dry thermals consistent with classical theory based on dimensional analysis. The simulations are also consistent with theory relating impulse, circulation, and spreading rate for dry thermals proposed in previous papers and extended here to moist thermals, predicting they will spread less than dry thermals. Tests adding heating to dry thermals, either spread uniformly across the thermal volume or concentrated in the inner core, indicate that dR / dz and ε are smaller for moist thermals because latent heating is confined mostly to their cores. Additional axisymmetric moist simulations using modified lapse rates and large-eddy simulations support this analysis. Overall, these results indicate that slow spreading rates are a fundamental feature of moist thermals caused by latent heating that alters the spatial distribution of buoyancy within them relative to dry thermals.

54 ENVIRONMENTAL SCIENCES↗

Comparison of JPL and European Environmental Testing Standards

A comparison of JPL and European environmental testing standards is presented. The contents include: 1) JPL Environmental Testing Documents; 2) Focus of the Comparison; 3) Test Policy; 4) Documentation; 5) Programmatics; 6) Functional Testing; 7) Reporting; 8) Dynamics Test Levels, Durations, & Margins; 9) Thermal Test Levels, Durations, & Margins; and 10) EMC Test Levels, Durations, & Margins.

spacecraft↗

Photogrammetric recession measurements of an ablating surface

An instrument and method for measuring the time history of recession of an ablating surface of a test article during testing in a high enthalpy thermal test facility, such as an arcjet. The method advances prior art by providing time-history data over the full ablating surface without targets and without any modifications to the test article. The method is non-intrusive, simple to implement, requires no external light source, and does not interfere with normal operations of the arcjet facility.

Schairer, Edward T.↗

Using Enterprise Architecture for Analysis of a Complex Adaptive Organization's Risk Inducing Characteristics

Sandia National Laboratories is an organization with a wide range of research and development activities that include nuclear, explosives, and chemical hazards. In addition, Sandia has over 2000 labs and over 40 major test facilities, such as the Thermal Test Complex, the Lightning Test Facility, and the Rocket Sled Track. In order to support safe operations, Sandia has a diverse Environment, Safety, and Health (ES&H) organization that provides expertise to support engineers and scientists in performing work safely. With such a diverse organization to support, the ES&H program continuously seeks opportunities to improve the services provided for Sandia by using various methods as part of their risk management strategy. One of the methods being investigated is using enterprise architecture analysis to mitigate risk inducing characteristics such as normalization of deviance, organizational drift, and problems in information flow. This paper is a case study for how a Department of Defense Architecture Framework (DoDAF) model of the ES&H enterprise, including information technology applications, can be analyzed to understand the level of risk associated with the risk inducing characteristics discussed above. While the analysis is not complete, we provide proposed analysis methods that will be used for future research as the project progresses.

99 GENERAL AND MISCELLANEOUS↗