Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Acceptance criteria for in situ surveillance of MSR materials based on thermally-loaded mechanical test articles

This report describes practices and acceptance test procedures for designing, running, and maintaining a material surveillance program in a future operating molten salt reactor. The programs described here rely on test data from passively actuated mechanical test articles inserted into critical regions of the reactor and periodically removed for out-of-reactor testing. The report defines definite acceptance procedures, based on the results of these tests, to determine whether a component can continue to operate accounting for the accumulation of environmentally-assisted mechanical damage in the component materials to date, and extrapolated out through the next inspection period. Additionally, the report describes work on a software tool implementing many of the surveillance methods and procedures described here and progress on simplified methods for inferring damage accumulation in the test articles, based on out-of-reactor thermal cycling, that do not rely on sophisticated numerical analysis.

36 MATERIALS SCIENCE↗

Microstructural Engineering and Accelerated Test Method Development to Achieve Low Cost, High Performance Solutions for Hydrogen Storage and Delivery

This project made advancements in developing lower cost steel alloys with novel microstructural design for use in hydrogen refueling infrastructure such as storage, compressors, and dispensing components, and utilizing accelerated test methods to efficiently evaluate variations in alloy and microstructure design. The project specifically sought to design alloys with lower nickel contents to reduce alloy cost, which was accomplished through substituting manganese for nickel along with other alloy additions to control deformation characteristics known to be important for hydrogen embrittlement resistance. Through Mn substitutions for nickel, austenitic and duplex austenite-ferrite steels were successfully developed with lower cost than currently available commercial stainless steel products that are employed for hydrogen refueling infrastructure. The steels were processed to achieve comparable strength and toughness in hydrogen environments as the commercially available steels containing high Ni contents. To evaluate mechanical performance in hydrogen, a testing methodology was employed to compare ubiquitous laboratory testing using electrochemical hydrogen charging in a liquid electrolyte to less accessible high pressure gaseous testing. While the application of these steels is in high pressure gaseous environments, the electrochemical hydrogen charging tests produced comparable results. Additionally, the Los Alamos Neutron Scatting Center enabled characterization of deformation mechanisms of the steel alloys in the presence of hydrogen, which has been associated with steel alloy characteristics associated with hydrogen embrittlement. Finally, a fracture mechanics based test bed model was developed to predict the influence of hydrogen gas pressure and fatigue conditions on fatigue lifetimes of pressure vessel steels. Together, these developments can be employed to enable lower cost hydrogen fueling infrastructure and more reliable prediction of steel alloy components in hydrogen service conditions. In particular, the newly alloys have the potential to replace stainless steels, having demonstrated comparable performance at substantially reduced cost.

08 HYDROGEN↗

Affinity of LDR Organics to Cementitious Materials: Sorption and Leaching Tests

SRNL is working to identify and test the physiochemical interactions of organic contaminants of potential concern with minerals in grout/cementitious materials. Organic species may interact with cementitious minerals including slag, fly ash, cement, and other components/dopants like carbon in fly ash. The identification of such interactions will support the solidification process design, performance assessments for the chemicals of concern, and a proposed Resource Conservation and Recovery Act (RCRA) treatment variance the technology-based treatment standard specified for the Land Disposal Restriction (LDR) organics associated with Hanford tank waste. In FY24, a list of the 132 reasonably expected to be present LDR organics associated with Hanford tank waste (RPP-RPT-63493, Rev 1a) was screened by functional groups, octanol-water partitioning coefficients, and detection frequency in Hanford tank waste samples. A subset of 10 compounds spanning the identified properties were tested using sorption and leachate tests. These compounds were subject to traditional batch sorption tests and leaching tests on/from Cast Stone cementitious material with and without activated carbon (a potential organic adsorption additive). The tests have been completed and analysis is underway but as yet currently unavailable. The analytical results (and conclusions) will be included in a forthcoming revision to this report as soon as they are available

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Single Event Error (SEE) test and analysis of the CMS Endcap Timing Layer readout chip

The ETROC2, the first full size and full functionality prototype chip for the CMS Endcap Timing Layer readout, is strategically designed to meet the SEE immunity requirements of detector operation with the low power constraint. The triplicated periphery and pixel I2C configuration registers are designed with self-correction feature. The pixel readout control is centralized in the global readout and fully triplicated. The pixel readout is not triplicated, instead protected with power-efficient one-bit correction Hamming code. The TMR protection of the on-pixel threshold calibration can be turned off allowing the detection of the beam spot during the beam test by checking the bit-flips of the internal memory cells. In the initial proton beam test in January 2024, the chip readout process did not hang throughout the tests. The Hamming code correction strategy works because the error corrected TDC data were observed in the data frames. The error-injection simulation is performed to analy ze the small number of bit-flips in the configuration registers. We also performed SEE testing with a heavy ion beam in April and the data analysis is ongoing. The detailed design on the SEE immunity and the testing as well as simulation results will be presented, including follow-up SEE testing results in May and June 2024.

Gong, Datao↗

Test and Validate Distributed Coaxial Cable Sensors for in situ Condition Monitoring of Coal-Fired Boiler Tubes

This project aims to test, validate, and advance the technology readiness level (from TRL5 to TRL7) of a novel low-cost distributed stainless-steel/ceramic coaxial cable sensing (SSC-CCS) technology for in situ monitoring of the boiler tube temperature in existing coal-fired power plants. The novel SSC-CCS sensing technology and associated condition-based monitoring (CBM) software to be demonstrated in this project will lead to an improved understanding of the boiler tube failure mechanisms and a prognostic system to improve the overall performance, reliability, and flexibility of the nation’s coal-fired power plant fleet. A boiler tube monitoring system with distributed coaxial cable temperature sensors and a sensor acquisition system was constructed. The high-temperature coaxial cable sensor with a length of 1.3m was made by using a quartz tube (1mm inner diameter (ID) and 6mm outer diameter (OD)) to concentrically separate a 304 stainless-steel (SS) rod (1mm OD) and SS tube (7.94mm OD and 6.16mm ID). The sensor acquisition system includes a vector network analyzer (VNA), a radio frequency (RF) power amplifier, multiple switches and a USB hub. The distributed stainless-steel quartz coaxial cable sensor (SSQ-CCS) had a linear response to temperature with a resolution uncertainty of σ = 0.77℃. To withstand the harsh conditions of 3,300 steam pressures and 800℃ high temperatures, the sensor was shielded by a protective tube made of the same material as the boiler tube. The protection tube had an OD of 1.5 inches and a thickness of 0.25 inches. In the laboratory tests, the sensor showed good sensitivity and fast response. The drift was bounded between +0.33% and -0.67% during a test at 600℃ for 350 hours, indicating good stability of the sensor. A field test was conducted where four sensors were welded on four superheat tubes (SH-Ts) at a coal-fired power station over 400 days. Conventional thermocouples were welded to the superheater tubes alongside the coaxial cable sensors for the purpose of comparison. Two sensors were capable of distributed sensing, with three multiplexed sensing sections. The other two sensors were single section. During the 400-day test period, the power plant experienced startups and shutdowns. At the steady state operations, the temperature of the boiler tube is about 600℃ (1112°F). The sensors recorded the entire coal-firing processes (start-up, steady state, and shut-down) and the glitch event. A GSM modem and a Watchdog were added to the system to ensure reliable data recording. The GSM modem sent daily messages to plant managers and Clemson team to inform the status of the sensor system. If the system was not normally working, the Watchdog would reboot the system automatically. The new coaxial cable based distributed sensing technology has been proven to be successful in both laboratory and field tests. A comprehensive four-stage multi-physics computational framework has been developed to assist the design, optimization, installation, and operation of SSQ-CCS. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. A conditional-based monitoring system is implemented as well. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

01 COAL, LIGNITE, AND PEAT↗

Affinity of LDR Organics to Cementitious Materials: Sorption and Leaching Tests

SRNL is working to identify and test the physiochemical interactions of organic contaminants of potential concern with minerals in grout/cementitious materials. Organic species may interact with cementitious minerals including slag, fly ash, cement, and other components/dopants like carbon in fly ash. The identification of such interactions will support the solidification process design, performance assessments for the chemicals of concern, and a proposed Resource Conservation and Recovery Act (RCRA) treatment variance specified for the Land Disposal Restriction (LDR) organics associated with Hanford tank waste. Inably expected to be present LDR organics associated with Hanford tank waste (RPP-RPT-63493, Rev 1a) was screened by functional groups, octanol-water partitioning coefficients, and detection frequency in Hanford tank waste samples. A subset of 10 compounds, spanning the identified properties, were tested using sorption and leachate tests. These compounds were subjected to traditional batch sorption tests and leaching tests on/from Cast Stone cementitious material with and without activated carbon (a potential organic adsorption additive). The interactions between organic compounds were observed in traditional batch sorption and modified Toxic Characteristic Leaching Procedure (TCLP) leachate tests for a surrogate Cast Stone material with and without an activated carbon addition. Specifically, phthalic acids (negatively charged) and 4-chloroaniline (polar) sorbed strongly to unmodified Cast Stone and a group of 3 phenolic compounds (2,4,6-Trichlorophenol, Pentachlorophenol, o-Cresol) were sorbed to and were retained by Cast Stone with a 1% activated carbon amendment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assessment of Flow-Enhanced Electrochemical Sensor Testing and Deployments for MSRs

This report serves as the deliverable for Milestone M3RS-23AN0401061 that is part of Work Package RS-23AN040106 (Flow Enhanced Sensors for MSRs – ANL). The goal of this milestone was to determine performance of the flow enhanced electrochemical sensor (FEES) and modular flow instrumentation testbed (MFIT) in safeguards relevant scenarios. Flow enhanced electrochemical sensors are a type of electroanalytical sensor that has been developed at Argonne National Laboratory to be installed directly into MSR flow conduits to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. Previous work has focused on testing of the FEES in flowing conditions provided by the MFIT to assess the accuracy and precision of the sensor measurements. To further improve this capability, in FY23 we undertook a campaign of safeguards relevant scenarios in molten salt containing a range of uranium chloride concentrations (0 to 3 wt%). All the testing carried out in FY23 was aided by a control system designed to automatically actuate flow conditions and collect data. This new automation system is estimated to have increased experimental throughput by a factor of four and enabled testing in a variety of complex conditions. The advancements in throughput and repeatability led to improved quantification of actinide concentrations using the in-flow sensors, with a reduction of the mean absolute relative error from 5.6% in FY22 to 3.1% in FY23. In addition to safeguards scenarios run in the MFIT, FY23 work included deployment of a FEES at a partner institution where it will be tested in a flowing salt loop. The FEES was successfully integrated into that loop and is being tested prior to loop startup. In FY23, work also continued on the smaller flow system that we have named the mini-MFIT. This smaller system is capable of rapid prototyping of new sensor designs prior to installation in the larger MFIT radiological flow system. Work was carried out to test this new system in non-radiological molten salts in a separate glovebox. This work is helping us to enhance the accuracy of our salt monitoring capabilities through the integration of multiple types of sensors. The high degree of accuracy required by 10 CFR 74 represents a significant challenge, and further design evolution and integration of the sensors into multimodal sensing frameworks will be needed to further push the measurement accuracy to the needed level.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

BioID/LID System Cartridge Testing Report

LLNL produced two lots of lyophilized LAMP assay containing cartridges, LNL022818 and LNL071818, for testing on Gen3 BioID systems. Thirty-nine cartridges were tested for lot LNL022818. All thirty-nine cartridges performed as expected regarding correct positive control (IPC) and negative control (NTC) reactions. Five different templates were tested on these 39 cartridges. The BioID system detected 79.1% true positives and 9.3% false positives along with 98.9% true negatives and 2.9% false negatives for cartridge lot LNL022818. Thirty cartridges were tested for lot LNL071818. It was noted early that due to a manufacturing issue with the cartridges related to incomplete sonic welding of the cartridge, a large fraction of lot LNL071818 cartridges leaked. Insufficient funds were available to replace this lot of cartridges. Twenty three of 30 cartridges performed as expected regarding correct positive control (IPC) and negative control (NTC) reactions. Four different templates were tested on these 30 cartridges. The BioID system detected 77% true positives and 23% false positives along with 96.9% true negatives and 3.1% false negatives for cartridge lot LNL071818. For all tested cartridges using DNA template, DNA was added at a final concentration of 25 pg/ul. All reactions contained positive control DNA at 2.5 pg/ul.

42 ENGINEERING↗

Field Test Report Neutron Scintillator Array Dry Storage Cask Scanner FY2024

During two weeks of Field Testing at the Idaho National Laboratory INTEC Cask Farm in July and August 2024, the LLNL Dry Storage Cask Scanner Array was lifted on top of an MC-10 dry storage fuel cask and operated to acquire neutron and gamma-ray data from the 24 fuel bundle positions. Neutron and gamma-ray data acquisition scans across the top of the cask of varying dwell times were performed July 15-18, 2024 and August 19-22, 2024 to evaluate the ability of the scanner data to reveal asymmetries in the fuel positions that reflect asymmetries in the MC-10 cask fuel bundle loading. The MC-10 cask 24 position fuel bundle loading at the INTEC Cask Farm is well documented, including the locations of six empty fuel bundle positions. This loading presents an opportunity to test the ability of the scanner system to detect diversion of spent fuel bundles as well as to validate the MC-10 cask MCNP modeling. The cask scanner array consists of six Stilbene crystal scintillator detectors and a linear actuator frame that moves the six detectors across the MC-10 dry storage cask to obtain data above each of the 24 fuel bundle positions. The detectors are connected to a pulse-shape discrimination data acquisition system capable of generating separate neutron and gamma-ray spectra for each detector and for each scan position. From the prior single detector Field Test in 2021 and iteration with MCNP modeling, the neutron and gamma-ray data were analyzed in multiple energy regions to identify an analysis method that would provide the strongest and most consistent signature of the asymmetric MC-10 cask fuel loading1 . From both the 2021 Field Test and the current Field Test results, the neutron capture gamma-ray count rate around 2.2 MeV provides the strongest signature of the asymmetric MC-10 cask fuel loading and has qualitative agreement with MCNP calculations. Counting all gamma-rays produces a similar signature. Neutrons emerging from the cask top are moderated and captured by the hydrogen in the polyethylene moderator and scintillator detector, producing a 2.2 MeV gamma ray which is seen in the scintillator gamma-ray spectrum. The count rate in the 2.2 MeV gamma-ray region is ~50 c/s, which is ~1000x higher than the ~0.05 n/s rate in the > 4MeV neutron region, and ~50x greater than the ~1 n/s rate in the neutrons > 500 keV region. Analysis of the 2.2 MeV neutron-capture Compton-scattered gamma-rays produces a statistically significant signature of the INTEC Cask Farm MC-10 asymmetric fuel loading. MCNP simulations indicate that the average neutron energy spectrum offers the potential to detect a large asymmetry from several missing bundles as well as individual missing fuel bundles. Testing this feature will require measurements on a cask with single missing elements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Full Submersion Water Testing of SAVY-4000 Nuclear Material Storage Containers

SAVY-4000 (SAVY) containers are the primary container used at Technical Area (TA) TA-55 plutonium facility for the prevention of water ingress to mitigate against a criticality event. The basis for water resistance of these containers has long been attributed to the Polytetrafluoroethylene (PTFE) membrane that is assembled on the outermost surface of the filter assembly. On August 22nd a test of a container used inside of a glovebox was performed that brought into question this long-standing-basis. This test was performed by inverting a SAVY-lid onto a specialized piece of equipment for evaluating the integrity of the PTFE membrane. During the test water was observed passing through the filter indicating that the filter membrane was no longer preventing the ingress of water through the filter. The assumption after making this observation was that alpha-particles were rapidly degrading the membrane creating a leak path through the underlying aluminosilicate media (Fiberfrax®). The apparatus used was designed to only test the lid rather than the entire SAVY assembly. A test plan, PA-PLAN-01921, was developed to investigate whether a fully assembled container with a fully degraded PTFE membrane would be capable of meeting the criteria defined in PA-RD-1009 of not allowing more than 200 ml of water to enter the container with a water column of 6-inches applied over a 2-hour period. This report provides the results of the testing performed against PA-PLAN-01921.

36 MATERIALS SCIENCE↗

SAS4A/SASSYS-1 Validation with FFTF Tests

The FFTF liquid sodium cooled test reactor was built to assist the development and testing of advanced fuels and material for fast reactors. The goals of the FFTF Passive Safety Testing program included confirming the safety margins of FFTF as a liquid metal reactor, providing data for computer code validation, and demonstrating the inherent and passive safety benefits of its specific design features. The program included thirteen unprotected loss of flow without scram tests. In preparation for the Passive Safety Testing program, a series of individual reactivity feedback tests were performed which were designed to simulate and validate specific features and reactivity feedbacks of the FFTF core.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Real time heat load calculation software based on EPICS for Fermilab PIP-II CM tests

Fermilab has a project to improve the proton beam energy which is called PIP-II (the 2nd Proton Improvement Plan). There is a superconducting linear accelerator, LINAC, to improve the proton beam power and the LINAC consists of 5 types of cryomodules (CM), 1 HWR CM, 2 SSR1 CM, 4 SSR2 CM, LB650 CM, and HB650 CM. The prototypes of these cryomodules are being tested at Fermilab’s CryoModule Test Facility (CMTF). Heat load measurements are an important part of the prototype CM testing. The CMTF cryogenic control system was developed based on the ACNET (Accelerator Control NETwork) for CM testing for other projects, but the PIP-II cryogenic control system will be implemented using the Experimental Physics and Industrial Control System (EPICS). As part of the prototype CM testing campaign an EPICS based control system has been implemented at CMTF. This EPICS cryogenic control system includes real time heat load calculation software utilizing the Fortran implementation of Hepak. This paper details the real time heat load calculation software developed for the prototype CM testing including the first results from the HB 650 CM.

Yoon, S. [Fermilab]↗

Transient Testing of Nuclear Fuels Performed in the Original Operation of TREAT, Third Edition

TREAT core was upgraded at the end of the 1980s. The tests performed since about 1970 are summarized in considerable detail. Earlier tests are noted by their designated series and by some parameters that help to identify and distinguish each series from the others. The detailed summary descriptions are intended to help inform future researchers regarding the large, historical, empirical data base generated from that 35-year span during which hundreds of TREAT experiments were performed to investigate and demonstrate the transient behavior of a wide variety of nuclear fuels during severe off-normal and accident conditions -- using direct nuclear heating of the test samples. That empirical basis is foundational and valuable for guiding future qualification and safety evaluation of improved fuel designs and for future transient test planning and performance in TREAT. The second edition of this report added descriptions of the following test series: D, E, EOS, F, H, J, R, RX, and S. This third edition includes descriptions of an additional four test series: the HUT, HOP (& HUC), ORNL-TR, and PNL.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Sierra/SolidMechanics 5.26 Verification Tests Manual

Presented in this document is a small portion of the tests that exist in the Sierra/SolidMechanics (Sierra/SM) verification test suite. Most of these tests are run nightly with the Sierra/SM code suite, and the results of the test are checked versus the correct analytical result. For each of the tests presented in this document, the test setup, a description of the analytic solution, and comparison of the Sierra/SM code results to the analytic solution is provided.

97 MATHEMATICS AND COMPUTING↗

Long-Term Evaluation of Remedial Technology Performance in the Laboratory: Multi-year Experimental Test Plan

An understanding of the long-term effectiveness of remediation technologies is central to sustainable environmental cleanup. Long-term experiments are valuable for reducing uncertainty and predicting remediation outcomes at scales required for regulatory compliance. However, these types of tests can be costly and challenging to interpret. Therefore, contaminated sites often rely on short-term laboratory experiments that may not account for the potentially significant effects of gradual, time- dependent processes governing contaminant retention, release, and species transformation. For example, short-term lab experiments (from months to a year) conducted with sediments from the unsaturated and saturated zones at the Hanford Site play an important role in initial evaluations of remediation technologies but cannot capture the full extent of time-dependent reactions, leaving uncertainties in field-scale deployment. Here, long-term testing will be conducted on select technologies based on their performance in short-term testing. The overall objective is to directly address the challenges described above by generating and analyzing data on long-term (2–10 years) efficacy of selected remediation technologies, integrating this understanding into models, and providing critical input for remediation planning, monitoring, and 5-year review cycles for field-implemented remedies. Specific objectives include: 1. Evaluating long-term efficiency of promising remedies under site-specific conditions. 2. Generating robust parameters for modeling, reducing uncertainty in predictive simulations. 3. Advancing integrated monitoring by combining geochemical and geophysical observations. 4. Informing field-scale implementation by incrementally advancing technologies, identifying failure mechanisms early, and prioritizing robust, cost-effective remedies. Through systematic evaluation of technologies in laboratory-scale column experiments, integrated monitoring, and modeling support, this project is designed to bolster confidence in the long-term robustness of selected technologies. The ultimate outcome is the identification and deployment of more reliable, cost-effective remedies that safeguard human health and the environment while reducing the uncertainties that have historically hindered cleanup progress at Hanford Site. An experimental approach was developed and initiated for long-term testing potentially up to 10 years. The table below summarizes the experimental approach developed for testing select technologies and presented in this multi-year experimental test plan.

54 ENVIRONMENTAL SCIENCES↗

FY20 Improvements to CTF Code Verification and Unit Testing

In 2010, the U.S. Department of Energy created its first Energy Innovation Hub, which focuses on improving Light Water Reactors (LWRs) through Modeling and Simulation. This hub, named the Consortium for the Advanced Simulation of LWRs (CASL), attempts to characterize and understand LWR behavior under normal operating conditions and use any gained insights to improve their efficiency. In collaboration with North Carolina State University (NCSU), CASL has worked extensively on the thermal-hydraulic subchannel code Coolant Boiling in Rod Arrays–Three Field (COBRA-TF). The NCSU/CASL version of COBRA-TF has been rebranded as CTF. This document focuses on code verification test problems that ensure CTF converges to the correct answer for the intended application. The suite of code verification tests are mapped to the underlying conservation equations of CTF, and significant gaps are addressed. Convergence behavior and numerical errors are quantified for each of the tests. Tests that converge at the correct rate to the corresponding analytic solution are incorporated into the CTF automated regression suite. A new verification utility is created for this purpose, which enables code verification by generalizing the process. For problems that do not behave correctly, the results are reported but the problem is not included in the regression suite. In addition to verification studies, this document also quantifies the existing tests of constitutive models. A few existing gaps are addressed by adding new unit tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

IOTA Pre-Bake Test Development

The poster presentation prepared for the IOTA (Integrable Optics Test Accelerator) Pre-Bake Test Development project consists of introducing the background of the project, the work completed, and the new test configurations available with the newly designed assembly. It explains the scale of the projects, both within the IOTA ring assembly and test assembly, and describes the purpose in baking or incrementing and holding exterior heat on the beampipe to reduce impurities in the vacuum. The originally designed test, Configuration One, uses RCA scans on the interior of the pipe, increments and holds heat for a set amount of time, and is scanned again to check for water evaporation. Configuration Two begins with the same test for Configuration One but has a second cross section of beampipe separated by a gate valve. After configuration one is complete, the gate valve opens, and after a period of cooling the other side is heated, molecular movement is scanned and observed.

Seagrave, Kayla [DuPage Coll.]↗

Engineering-Scale Test of a Water-Lean Solvent for Post-Combustion Capture

EPRI, Pacific Northwest National Laboratory, RTI International, and their project collaborators developed an engineering-scale test of a new water-lean solvent, N-(2-ethoxyethyl)-3-morpholinopropan-1-amine (EEMPA or 2-EEMPA) as a post-combustion CO 2 capture solvent for power plant applications. This test was conducted using the Pilot Solvent Test Unit at the National Carbon Capture Center. The primary objective of this test was to collect long-term data operating EEMPA with both coal- and natural gas-representative flue gases at the approximately 0.5 MW e -equivalent scale (5–10 metric tons CO 2 /day captured). This report details the activities preparing for that test, data collected during the test campaign, and analyses and interpretations of that data.

20 FOSSIL-FUELED POWER PLANTS↗