Atom Probe Tomography and Three-Dimensional Atomic Scale Characterisation of Interplanetary Dust Particles: Inorganic and Organic, Hydrous and Anhydrous Assemblages

Interplanetary dust particles (IDPs)preserve primordial fragments from our Solar System and external stellar systems, sampled from a vast range of dust forming bodies that often display smaller degrees of parent body processing than is seen in meteorites. IDPs preserve some of the smallest astromaterials from our Solar System, many of which are believed to be among the most important materials for studying physical and chemical processing, and formation mechanisms occurring within the interstellar medium (ISM), Solar Nebula and external planetary systems[1]. However, their formation processes and provenance are poorly constrained, owing in part to spatial resolution limitations of traditional analytical techniques. Atom probe tomography (APT) uses a pulsed laser to field-evaporate material at the atomic scale from needle-shaped samples, and time-of-flight spectrometry for 3D reconstruction of element and isotope distribution in samples after data acquisition. This technique has the highest spatial resolution available of any technique used within the geoscience field[2]. However, measuring multi-phase specimens and porous media in APT can be challenging, two primary characteristics of IDPs. Here we present a custom method for APT needle design and the first results of a 3Datomic scale study of interplanetary dust particles, salt crystals and extraterrestrial insoluble and soluble organic matter designed to overcome the challenges of studying IDP-like materials.

N D Nevill↗

A New Coordinated NanoSIMS, Transmission Electron Microscopy and Atom Probe Tomography Approach For the Characterization of Primitive Astromaterials

Presolar grains are remnants of evolved stellar systems preserved within primitive extraterrestrial materials. They are important for studying physical and chemical processing, and formation mechanisms occurring within the interstellar medium, Solar Nebula and their parent stellar environments [1]. Our recent work has shown coordinated nano-scale Secondary Ion Mass Spectrometry (NanoSIMS) and Atom Probe Tomography (APT) can show isotopic and chemical signatures at major to trace levels, morphological signatures, and regional contextual relationships [2,3]. Previous studies have shown Transmission Electron Microscopy (TEM) of Focus Ion Beam (FIB) TEM lamella, can provide localized contextual relationships, crystallographic information and chemical information [1]. Coordinating NanoSIMS, TEM, and APT could gain access to almost all contextual, structural and geochemical signatures within each presolar grain. However, this has proved challenging owing to the preparation requirements for TEM and APT. For example, studying specimen prepared as APT needles in TEM removes the local context, the higher degree of surface exposure can alter the chemistry of beam sensitive materials, and the shank angle of the needle can impact the quality of TEM diffraction images. We designed a new FIB method which takes a 100 nm thick FIB-TEM lamella and sandwiches it between two indium slices (5 μm x ~300 nm x 3 μm). The indium is melted onto the lamella surface using the electron beam (Fig 1). This process adds bulk to the lamella, making it more amenable to APT needle formation (Fig 2). Consequently, samples can be prepared per the optimal requirements for each technique improving data quality, acquisition stability, and access to the signatures and relationships summarised earlier. This technique can be used for measuring multiple phases across a TEM lamella and targeting an individual phase. For example, a presolar grain identified in NanoSIMS could be targeted, studied in TEM and then indium sandwiched with its precise location in the TEM lamella marked using a Pt button for preparation of an APT needle and atomic scale acquisition. [1] A. M. Davis (2014) Meteorites and cosmochemical processes, 1. [2] Nevill N. et al. (2023) LPSC, 54, #1707. [3] Nevill N. et al. (2023) LPSC, 54, #1714.

NanoSIMS↗

Electrical Impedance Tomography Technology: 2013 Center Innovation Fund Final Report

Electrical impedance tomography is a medical noninvasive imaging technology which has advantages over other medical imaging technologies for medically safe long term real time internal imaging monitoring applications in human patients. The technology is much more compact, portable, low power and potentially more low cost compared to other medical image technologies, making it very well suited for medical aerospace and spaceflight applications. EIT technology’s main drawback has been low image resolution, and consequently improving EIT resolution is the primary research goal, as well as increasing imaging speed for real time animation imaging. In a relatively short time the BERL group has brought together design plans, technical resources and has built and tested hardware with the purpose of improving EIT imaging technology. EIT prototype system development plans and system designs have been made to target needed EIT technical improvement in electronic and computer hardware as well as EIT software technology. New hardware design and fabrication resources and technologies have been brought together through resourceful use of existing equipment and software at BERL, and a significant advance has been made in custom electronic hardware prototyping capabilities in collaboration with EFAL, for mutual benefit for both NASA KSC laboratories. BERL has gained significant EIT software capability and tested EIT imaging algorithm code through collaboration with an internationally recognized EIT software development and research forum. A new custom workstation has been developed, built and tested using internal resources, equipment and expertise, that includes a new state-of-the-art massively parallel technology that is commercially available. Custom prototype hardware has been designed and tested, a high priority electronic design, key to improving electronic performance and image quality, has been researched and tested in four designs, with a summary of test results of the selected design illustrated here. The selected design performance exceeds the developed EIT design hardware specifications.

Michael R Lapointe↗

Using Multiplicative Algebraic Reconstruction Techniques (MART) to Derive Instrument Requirements for Computed Tomography Imaging Spectrographs

Computed Tomography Imaging Spectrographs (CTISs), which are generally slitless or large-aperture spectrographs that observe a wide, dispersed field of view in multiple dispersion angles or diffraction orders, provide a unique opportunity to capture spectral information over an extended source, such as the Sun, but require software reconstruction techniques to be fully utilized. A useful data product that can be recovered from CTIS observations is intensity maps of solar features in single spectral lines. These intensity maps can then be used to determine temperature, density, abundance, and equilibrium properties of the emitting plasma. We apply the multiplicative algebraic reconstruction technique (MART) to example data from a variety of CTIS configurations to determine the capability and limitations of the method to return spectrally-pure maps. By completing this study, we aim to establish a path to derive requirements for CTIS instruments that rely on reconstruction techniques to meet their science objectives.

Amy Winebarger↗

Investigating the Impact of X-Ray Computed Tomography Imaging on Soluble Organic Matter in the Murchison Meteorite: Implications for Bennu Sample Analyses

X-ray computed tomography (XCT) is a valuable reconnaissance tool for three-dimensional imaging and identification of distinct lithologies in extraterrestrial samples. It will be used as part of the preliminary examination of samples returned from asteroid (101955) Bennu by the Origins, Spectral Interpretation, Resource Identification, and Security–Regolith Explorer (OSIRIS-REx) mission. However, it must first be established whether x-rays generated during XCT could degrade or alter the organic composition of the returned samples by radiolysis. To test this, we split a crushed sample of the Murchison CM2 meteorite, kept one portion as a control, and irradiated the other portion up to the maximum x-ray dosage (~180 Gy) that a Bennu sample would experience during an XCT imaging experiment. We then extracted organic compounds from both splits and conducted (i) nontargeted soluble organic analyses to compare the chemical distributions of C-, H-, O-, N-, and S-bearing species and (ii) targeted measurements to quantify the abundances of 96 individual soluble organic molecules that included protein amino acids, amines, carboxylic acids, hydroxy acids, carbonyl compounds, polycyclic aromatic hydrocarbons, alcohols, sugars, and N-heterocycles. We found that XCT imaging of the Murchison meteorite had no measurable impact on the relative abundances or enantiomeric compositions of most of the soluble organic compounds targeted in this study. Elevated total abundances of several soluble organic compound classes were observed in the XCT-scanned Murchison sample relative to the control. This is likely related to particle size heterogeneity and specific surface area differences between the sample aliquots used for the extractions, rather than a result of the x-ray exposure. Assuming the samples returned from asteroid Bennu by OSIRIS-REx have a similar composition to carbonaceous chondrites, these data provide confidence that XCT will not significantly alter their soluble organic compositions.

Daniel P Glavin↗

X-Ray Micro- and Nano-Tomography Analysis of Bennu Samples: A Preliminary Report

X-ray tomography (XCT) is an effective technique for obtaining the 3D structures of returned samples. XCT using synchrotron radiation provides high-resolution CT images with quantitative information. The XCT systems at SPring-8, an SR facility in Japan, have been used to analyze samples returned from the asteroids Itokawa and Ryugu. In this study, we plan to apply SR-XCT to samples returned from the asteroid Bennu.

A Tsuchiyama↗

Investigating Space Weathering of Ryugu Grains Using Electron Microscopy and X-Ray Computed Tomography

The effects of micrometeorite bombardment and solar wind ion irradiation – collectively known as space weathering – alter the microstructural, chemical, and spectral properties of airless surfaces. Characteristics of space weathering include vesiculated textures, amorphous grain rims (upper ~100 nm), and the production of Fe-bearing nanoparticles (npFe). The resulting modifications in the optical properties of the surface regolith include changes in spectral slope and overall reflectance of the surfaces as well as the attenuation of their characteristic absorption bands across VIS-NIR wavelengths. As the surface is continuously exposed to interplanetary space over time, the accrual of these features complicates the interpretation of remote sensing spectral data and the characterization of returned samples. Laboratory experiments that simulate solar wind irradiation and micrometeoroid impacts using carbonaceous analogs have revealed novel and complex microstructural and chemical changes, including the decrease in organic species concentrations and the reduction of Fe 3+ . In 2020, the Japan Aerospace Exploration Agency (JAXA)’s Hayabusa2 mission returned over 5 g of regolith particles from near- Earth C-type asteroid (162173) Ryugu – a unique opportunity to study space weathering on carbonaceous materials. Initial studies have established that the surface morphology and chemical signatures of space weathering in returned samples share characteristics with laser irradiation experiments simulating micrometeoroid bombardment, indicating that impacts are a significant space weathering mechanism operating on Ryugu. Here, we seek to improve our understanding of space weathering of carbonaceous asteroidal regolith grains by characterizing its effects directly on returned samples to determine the nature of space weathering on Ryugu. To do so, we performed coordinated analyses using electron beam techniques and X-ray computed tomography (XCT) to examine the effects of space weathering on grains returned from the surface of Ryugu by the Hayabusa2 mission.

L. E. Melendez↗

Geochemical Quantification of Olivine Minerals by Atom Probe Tomography

The ability of atom probe tomography (APT) to interrogate small sample volumes with high efficiency makes it uniquely useful in the study of small mineral grains or domains. Although it is frequently employed in the analysis of geological materials, particularly in the characterization of nanoscale chemical heterogeneities, the degree of quantitative accuracy achieved by APT can be difficult to determine.

D W Saxey↗

Methods and compositions for protection of cells and tissues from computed tomography radiation

Described are methods for preventing or inhibiting genomic instability and in cells affected by diagnostic radiology procedures employing ionizing radiation. Embodiments include methods of preventing or inhibiting genomic instability and in cells affected by computed tomography (CT) radiation. Subjects receiving ionizing radiation may be those persons suspected of having cancer, or cancer patients having received or currently receiving cancer therapy, and or those patients having received previous ionizing radiation, including those who are approaching or have exceeded the recommended total radiation dose for a person.

Grdina, David J.↗

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of anisotropic mechanical properties of polymer composites from a hybrid additive manufacturing-compression molding process using x-ray computer tomography

In this study, anisotropic stiffness tensors were reconstructed based on fiber orientation distributions obtained from X-ray computer tomography (xCT). A preform was manufactured via a big area additive manufacturing (BAAM) system with carbon fiber (CF) filled acrylonitrile butadiene styrene (ABS). The tailored preform from additive manufacturing (AM) was used in the compression molding (CM) process to produce a low-void high-performance thermoplastic composite panel. An xCT technique was employed to detect the fiber orientations in CF/ABS composites manufactured via three different methods: AM from BAAM, extrusion compression molding (ECM), and AM-CM. The anisotropic stiffness tensor was obtained from the composite panel manufactured via the three manufacturing methods (AM, ECM, and AMCM). A micromechanics theory was used to obtain the orthotropic stiffness tensors of the composite panels and compared with the experimental values. The predicted stiffness tensors of AM and AM-CM composite panels were used to study the deformation characteristics of a steering wheel during airbag deployment by performing finite element analysis (FEA). The approach developed in this study can be utilized for evaluating high-performance composites.

Pokkalla, Deepak↗

Composition and Structure of the EGS Collab Test Bed 1 Based Upon Electrical Resistivity Tomography, Core Compositions, and Wireline Logging

The nature of core from the EGS Collab project was characterized with high resolution XRF analyses on selected core intervals and wireline geophysical logs. Electrical resistivity profiles from the wireline geophysical surveys are consistent with the electrical resistivity tomographic three-dimensional images, and the XRF profiles show elevated levels of sulfur in the vicinity of the interpreted conductivity anomalies. The compositional and wireline logging data are consistent with interpretations from the electrical resistivity tomography data. Based upon these observations the best candidate for the source of the high electrical conductivities is the presence of significant amounts of sulfides within the unit.

Roggenthen, William↗

Systems and methods for increasing efficiency of ultrasound waveform tomography

Ultrasound tomography imaging methods for imaging a tissue medium with one or more ultrasound transducer arrays comprising a plurality of transducers, wherein said transducers comprise source transducers, receiving transducers. The methods include assigning a phase value or time delay to source transducers, exciting the transducers and calculating a search direction based on data relating to the excited transducers.

Huang, Lianjie↗

Systems and methods for point-of-care positron emission tomography

A positron emission tomography (PET) system is provided. The system includes a first detector panel including a first array of detectors, a second detector panel including a second array of detectors, said second detector panel being moveable relative to a point between the first detector panel and the second detector panel, a tracking system configured to detect a position of said second detector panel relative to the first detector panel while imaging a subject, a computing device in communication with the first detector panel, the second detector panel, and the tracking system, the computing device configured to receive coincidence data from the first and second detector panels, receive position data from the tracking system, wherein each coincidence datum of the received coincidence data is associated with a unique position datum of the received position data, and reconstruct a plurality of images based on the received coincidence data and the received position data.

Tai, Yuan-Chuan↗

Calibration method for a spectral computerized tomography system

A calibration method for an x-ray computerized tomography system and a method of tomographic reconstruction are provided. The calibration method includes steps of measuring at least one point spread function (PSF) at each of a plurality of points, compressing each PSF, and in one or more storing operations, storing the compressed PSFs in a computer-accessible storage medium. The PSF measurements are made in a grid of calibration points in a field of view (FOV) of the system. In the measuring step, an absorber is positioned at each of the calibration points, and an x-ray projection is taken at least once at each of those absorber positions. In the method of tomographic image reconstruction, projection data from an x-ray tomographic projection system are input to an iterative image reconstruction algorithm. The algorithm retrieves and utilizes a priori system information (APSI) The APSI comprises comprising point spread functions (PSFs) of all voxels in a voxelization of the field of view that are compressed in the form of vectors of parameters. For utilization, each retrieved vector of parameters is decompressed so as to generate a discretized PSF.

Jimenez, Jr., Edward Steven↗

Systems and methods for plane-wave and fan-beam ultrasound-waveform tomography

A method for plane-wave or fan-beam ultrasound tomography includes: controlling, by a processor, a multi-channel ultrasound array controller to control a linear ultrasound transducer array to emit plane-wave or fan-beam ultrasound into a biological tissue, the linear ultrasound transducer array including a plurality of transducers; receiving, by the processor, plane-wave or fan-beam ultrasound waveform data from the transducers, the plane-wave or fan-beam ultrasound waveform data including reflections of the plane-wave or fan-beam ultrasound from the biological tissue; computing, by the processor, a synthetic ultrasound-waveform inversion from the received plane-wave or fan-beam ultrasound waveform data; and computing, by the processor, an image of the biological tissue from the synthetic ultrasound-waveform inversion.

Huang, Lianjie↗

Ultrafast CMOS image sensors and data-enabled super-resolution for multimodal radiographic imaging and tomography

We summarize recent progress in ultrafast Complementary Metal Oxide Semiconductor (CMOS) image sensor development and the application of neural networks for post-processing of CMOS and charge-coupled device (CCD) image data to achieve sub-pixel resolution (thus $super$-$resolution$). The combination of novel CMOS pixel designs and data-enabled image post-processing provides a promising path towards ultrafast high-resolution multi-modal radiographic imaging and tomography applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗