Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Time and spectrum-resolving multiphoton correlator for 300–900 nm

We demonstrate a single-photon sensitive spectrometer in the visible range, which allows us to perform time-resolved and multi-photon spectral correlation measurements at room temperature. It is based on a monochromator composed of two gratings, collimation optics, and an array of single photon avalanche diodes. The time resolution can reach 110 ps and the spectral resolution is 2 nm/pixel, limited by the design of the monochromator. This technique can easily be combined with commercial monochromators and can be useful for joint spectrum measurements of two photons emitted in the process of parametric down conversion, as well as time-resolved spectrum measurements in optical coherence tomography or medical physics applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Time-resolved orbital angular momentum spectroscopy

We introduce pump-probe magneto-orbital spectroscopy, wherein Laguerre-Gauss optical pump pulses impart orbital angular momentum to the electronic states of a material and subsequent dynamics are studied with 100 fs time resolution. The excitation uses vortex modes that distribute angular momentum over a macroscopic area determined by the spot size, and the optical probe studies the chiral imbalance of vortex modes reflected off the sample. First observations in bulk GaAs yield transients that evolve on time scales distinctly different from population and spin relaxation, as expected, but with surprisingly large lifetimes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effective temporal resolution in pump-probe spectroscopy with strongly chirped pulses

This paper introduces a general theoretical description of femtosecond pump-probe spectroscopy with chirped pulses whose joint spectral and temporal profile is expressed by Wigner spectrograms. We demonstrate that the actual experimental time resolution intimately depends on the pulse-sample interaction and that the commonly used instrumental response function needs to be replaced by a sample-dependent effective response function. We also show that, using the proper configurations in excitation and/or detection, it is possible to overcome the temporal smearing of the measured dynamics due to chirp-induced pulse broadening and recover the temporal resolution that would be afforded by the transform-limited pulses. We verify these predictions with experiments using broadband chirped pump and probe pulses. Our results allow optimization of the temporal resolution in the common case when the chirp of the pump and/or probe pulse is not corrected and may be extended to a broad range of time-resolved experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing Laser-accelerated Ion Beams for a Collimated Neutron Source

High-flux neutrons for imaging and materials analysis applications have typically been provided by accelerator- and reactor-based neutron sources. A novel approach is to use ultraintense (>1018W/cm2) lasers to generate picosecond, collimated neutrons from a dual target configuration. In this article, the production capabilities of present and upcoming laser facilities are estimated while independently maximizing neutron yields and minimizing beam divergence. A Monte-Carlo code calculates angular and energy distributions of neutrons generated by D-D fusion events occurring within a deuterated target for a given incident beam of D+ ions. Tailoring of the incident distribution via laser parameters and microlens focusing modifies the emerging neutrons. Projected neutron yields and distributions are compared to conventional sources, yielding comparable on-target fluxes per discharge, shorter time resolution, larger neutron energies and greater collimation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental Developments for the Lamb Shift Investigation in Heavy Ions

Novel high-resolution spectrometer setups are presently commissioned for X-ray experiments at the Experimental Storage Ring (ESR) at GSI, Darmstadt, aiming at an accurate determination of QED corrections in the critical field limit via an accurate determination of the ground-state binding energy in a high-Z, H-like ion. Until now for H-like uranium, an accuracy of 1% could be reached in an experiment performed at the electron cooler, due to the deceleration capability of the ESR. A further improvement by almost one order of magnitude is envisaged by a transmission x-ray spectrometer setup in the FOcusing Compensated Asymmetric Laue (FOCAL) geometry, as well as by the implementation of high-resolution microcalorimeter devices.Here we report on the latest commissioning experiment of a two-arm transmission X-ray spectrometer, along with high-performance position-sensitive microstrip germanium detectors. Due to a photon efficiency of only 10{sup -8}, the position sensitivity, as well as the energy and time resolution of segmented solid-state germanium detectors, are absolutely essential for the experiment. In combination with the FOCAL spectrometer, these position-sensitive detectors permit the simultaneous measurement of all energies in the regime of interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-Resolved X-Ray Reflectometry in the Multiwavelength Dispersive Geometry

A new method of measuring specular X-ray reflectivity curves with a time resolution of milliseconds to seconds is developed. A horizontally convergent X-ray beam having a one-to-one correlation between its direction and energy is realized by a curved crystal or a laterally graded multilayer on an elliptic substrate. The X-ray beam is then incident on the surface of the specimen placed at the focus in such a way that the glancing angle in the vertical direction is the same for all X-ray components, which are reflected in the vertical direction by the surface and diverge in the horizontal plane. The perpendicular momentum transfer continuously changes as a function of the horizontal ray direction since the wavelength change similarly. The normalized linear intensity distribution across the beam direction measured downstream of the specimen represents the X-ray reflectivity curve. Examples of time-resolved measurements of X-ray reflectivity curves are shown.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Brightest Fermi-LAT flares of PKS 1222+216: implications on emission and acceleration processes

We present a high time resolution study of the two brightest γ-ray outbursts from a blazar PKS 1222+216 observed by the Fermi Large Area Telescope (LAT) in 2010. The γ-ray light curves obtained in four different energy bands, 0.1-3, 0.1-0.3, 0.3-1, and 1-3 GeV, with time bins of six hours, show asymmetric profiles with similar rise times in all the bands but a rapid decline during the April flare and a gradual one during the June flare. The light curves during the April flare show an ∼2 day long plateau in 0.1-0.3 GeV emission, erratic variations in 0.3-1 GeV emission, and a daily recurring feature in 1-3 GeV emission until the rapid rise and decline within a day. The June flare shows a monotonic rise until the peak, followed by a gradual decline powered mainly by the multi-peak 0.1-0.3 GeV emission. The peak fluxes during both the flares are similar except in the 1-3 GeV band in April, which is twice the corresponding flux during the June flare. Hardness ratios during the April flare indicate spectral hardening in the rising phase followed by softening during the decay. We attribute this behavior to the development of a shock associated with an increase in acceleration efficiency followed by its decay leading to spectral softening. The June flare suggests hardening during the rise followed by a complicated energy dependent behavior during the decay. Observed features during the June flare favor multiple emission regions while the overall flaring episode can be related to jet dynamics.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-751: Three-Component Kinetic Model of Tumor Growth and Radiation Response for Stereotactic Radiosurgery

Purpose: To develop and study a kinetic model of tumor growth and its response to stereotactic radiosurgery (SRS) by assuming that the cells in irradiated tumor volume were made of three types. Methods: A set of ordinary differential equations (ODEs) were derived for three types of cells and a tumor growth rate. It is assumed that the cells were composed of actively proliferating cells, lethally damaged-dividing cells, and non-dividing cells. We modeled the tumor volume growth with a time-dependent growth rate to simulate the saturation of growth. After SRS, the proliferating cells were permanently damaged and converted to the lethally damaged cells. The amount of damaged cells were estimated by the LQ-model. The damaged cells gradually stopped dividing/proliferating and died with a constant rate. The dead cells were cleared from their original location with a constant rate. The total tumor volume was the sum of the three components. The ODEs were numerically solved with appropriate initial conditions for a given dosage. The proposed model was used to model an animal experiment, for which the temporal change of a rhabdomyosarcoma tumor volume grown in a rat was measured with time resolution sufficient to test the model. Results: To fit the model to the experimental data, the following characteristics were needed with the model parameters. The α-value in the LQ-model was smaller than the commonly used value; furthermore, it decreased with increasing dose. At the same time, the tumor growth rate after SRS had to increase. Conclusions: The new 3-component model of tumor could simulate the experimental data very well. The current study suggested that the radiation sensitivity and the growth rate of the proliferating tumor cells may change after irradiation and it depended on the dosage used for SRS. These preliminary observations must be confirmed by future animal experiments.

60 APPLIED LIFE SCIENCES↗

TRACKING THE SOLAR CYCLE THROUGH IBEX OBSERVATIONS OF ENERGETIC NEUTRAL ATOM FLUX VARIATIONS AT THE HELIOSPHERIC POLES

With seven years of Interstellar Boundary Explorer ( IBEX ) observations, from 2009 to 2015, we can now trace the time evolution of heliospheric energetic neutral atoms (ENAs) through over half a solar cycle. At the north and south ecliptic poles, the spacecraft attitude allows for continuous coverage of the ENA flux; thus, signal from these regions has much higher statistical accuracy and time resolution than anywhere else in the sky. By comparing the solar wind dynamic pressure measured at 1 au with the heliosheath plasma pressure derived from the observed ENA fluxes, we show that the heliosheath pressure measured at the poles correlates well with the solar cycle. The analysis requires time-shifting the ENA measurements to account for the travel time out and back from the heliosheath, which allows us to estimate the scale size of the heliosphere in the polar directions. We arrive at an estimated distance to the center of the ENA source region in the north of 220 au and in the south a distance of 190 au. We also find a good correlation between the solar cycle and the ENA energy spectra at the poles. In particular, the ENA flux for the highest IBEX energy channel (4.3 keV) is quite closely correlated with the areas of the polar coronal holes, in both the north and south, consistent with the notion that polar ENAs at this energy originate from pickup ions of the very high speed wind (∼700 km s{sup −1}) that emanates from polar coronal holes.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal emittance and response time measurements of a GaN photocathode.

We present the measurements of thermal emittance and response time for a GaN photocathode illuminated with 5 ps pulses at 260 nm wavelength. The thermal emittance was measured downstream of a 100 kV dc gun using a solenoid scan with a wire scanner and a beam viewscreen and was found to be 1.35 {+-} 0.11 mm mrad normalized rms emittance per 1 mm rms of illuminated spot size. The response time of the photoemitted electrons was evaluated using a deflecting mode rf cavity synchronized to the laser pulses and was found to be prompt within the time resolution capability of our setup.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental station for laser-based picosecond time-resolved x-ray absorption near-edge spectroscopy

We present an experimental station designed for time-resolved X-ray Absorption Near-Edge Spectroscopy (XANES). It is based on ultrashort laser-plasma x-ray pulses generated from a table-top 100 mJ-class laser at 10 Hz repetition rate. A high transmission (10%–20%) x-ray beam line transport using polycapillary optics allows us to set the sample in an independent vacuum chamber, providing high flexibility over a wide spectral range from 0.5 up to 4 keV. Some XANES spectra are presented, demonstrating 1% noise level in only ∼1 mn and ∼100 cumulated laser shots. Time-resolved measurements are reported, indicating that the time resolution of the entire experimental station is 3.3 ± 0.6 ps rms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-resolved spectroscopy using a chopper wheel as a fast shutter

Widely available, small form-factor, fiber-coupled spectrometers typically have a minimum exposure time measured in milliseconds, and thus cannot be used directly for time-resolved measurements at the microsecond level. Spectroscopy at these faster time scales is typically done with an intensified charge coupled device (CCD) system where the image intensifier acts as a “fast” electronic shutter for the slower CCD array. In this paper, we describe simple modifications to a commercially available chopper wheel system to allow it to be used as a “fast” mechanical shutter for gating a fiber-coupled spectrometer to achieve microsecond-scale time-resolved optical measurements of a periodically pulsed light source. With the chopper wheel synchronized to the pulsing of the light source, the time resolution can be set to a small fraction of the pulse period by using a chopper wheel with narrow slots separated by wide spokes. Different methods of synchronizing the chopper wheel and pulsing of the light sources are explored. The capability of the chopper wheel system is illustrated with time-resolved measurements of pulsed plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2-ps Hard X-Ray Streak Camera Measurements at Sector 7 Beamline of the Advanced Photon Source

A hard X-ray streak camera capable of 2-ps time resolution is in operation at the Sector 7 beamline of the Advanced Photon Source. It is used for laser-pump, X-ray probe experiments using the Ti:Sapphire femtosecond laser system installed on the beamline. This streak camera, combined with standardized and prealigned experimental setups, can perform time-resolved liquid-phase absorption spectroscopy, reflectivity, and diffraction experiments.

43 PARTICLE ACCELERATORS↗

Note: Spectrometer with multichannel photon-counting detector for beam emission spectroscopy in magnetic fusion devices

A spectrometer based on a linear array photomultiplier tube (PMT) has been developed and calibrated. A 0.635 m focal length Czerny-Turner monochromator combined with a coupling optics provides an image of a narrow 0.5 nm spectral range with a resolution of 0.015 nm/channel on a 32-anode PMT. The system aims at spectroscopy of D{sub α} or H{sub α} lines emitted by a diagnostic atomic beam in a plasma (primarily a motional Stark effect diagnostics). To record a low photon flux of ∼10{sup 6} s{sup −1} per channel with the time resolution of 100 μs, a pulse counting approach has been used. Wideband amplifiers scale single-electron pulses and transmit them to a digital data processing core hardwired in a programmable logic matrix. Calibrations have shown that the aberration-limited instrument function fits to a single detector channel of 1 mm width. Pilot results of passive measurements of D{sub α} light emission from the plasma confined in a magnetic trap are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AUTOMATIC DETECTION ALGORITHM OF DYNAMIC PRESSURE PULSES IN THE SOLAR WIND

Dynamic pressure pulses (DPPs) in the solar wind are a significant phenomenon closely related to the solar-terrestrial connection and physical processes of solar wind dynamics. In order to automatically identify DPPs from solar wind measurements, we develop a procedure with a three-step detection algorithm that is able to rapidly select DPPs from the plasma data stream and simultaneously define the transition region where large dynamic pressure variations occur and demarcate the upstream and downstream region by selecting the relatively quiet status before and after the abrupt change in dynamic pressure. To demonstrate the usefulness, efficiency, and accuracy of this procedure, we have applied it to the Wind observations from 1996 to 2008 by successfully obtaining the DPPs. The procedure can also be applied to other solar wind spacecraft observation data sets with different time resolutions.

79 ASTRONOMY AND ASTROPHYSICS↗

Narrow Field of View Zenith Radiometer (NFOV) Handbook

The two-channel narrow field-of-view radiometer (NFOV2) is a ground-based radiometer that looks straight up and measures radiance directly above the instrument at wavelengths of 673 and 870 nm. The field-of-view of the instrument is 1.2 degrees, and the sampling time resolution is one second. Measurements of the NFOV2 have been used to retrieve optical properties for overhead clouds that range from patchy to overcast. With a one-second sampling rate of the NFOV2, faster than almost any other ARM Climate Research Facility (ACRF) instrument, we are able, for the first time, to capture changes in cloud optical properties at the natural time scale of cloud evolution.

54 ENVIRONMENTAL SCIENCES↗

Measurement of the edge plasma rotation on J-TEXT tokamak

A multi-channel high resolution spectrometer was developed for the measurement of the edge plasma rotation on J-TEXT tokamak. With the design of two opposite viewing directions, the poloidal and toroidal rotations can be measured simultaneously, and velocity accuracy is up to 1 km/s. The photon flux was enhanced by utilizing combined optical fiber. With this design, the time resolution reaches 3 ms. An assistant software “Spectra Assist” was developed for implementing the spectrometer control and data analysis automatically. A multi-channel monochromatic analyzer is designed to get the location of chosen ions simultaneously through the inversion analysis. Some preliminary experimental results about influence of plasma density, different magnetohydrodynamics behaviors, and applying of biased electrode are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of methods for ultrasonic scanning of X-ray wavelength

The method for X-ray wavelength tuning using an adaptive element (a quartz monolithic resonator modulated by a standing longitudinal low-frequency ultrasonic wave) has been proposed and implemented. This method is characterized by high tuning accuracy and possibility of scanning X-ray beam parameters with a time resolution of up to 3 μs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗