Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMAL STRESS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Microreactor Agile Nonnuclear Experimental Testbed Test Plan

Microreactors are an attractive technology option for kick-starting nuclear innovation if they can be operated at high temperature, yielding high power conversion thermal efficiencies comparable or better than in commercial light water reactors. Microreactors are currently the smallest variation of Small Modular Reactors (SMRs). SMRs are “newer generation reactors designed to generate electric power up to 300 MWe and whose components and systems can be shop-fabricated and then transported as modules to the sites for installation as demand arises.” (IAEA, 2016). Vendors are developing microreactor designs to provide an affordable, potentially mobile source of electricity - see Fig. 1 for an example of a microreactor on a semi-truck. Various microreactor designs are possible including heat pipe- and gascooled options, which are the focus of the nonnuclear testing described in this document. In heat pipe microreactors, high-temperature heat pipes using liquid sodium or potassium working fluid transport fission heat from the core to a heat removal section which in turn transfers heat to the power conversion system working fluid. In a gas-cooled design, He or other gas will flow through a solid monolith of material and transfer heat as the temperature of the gas increases through a heat exchanger to a power conversion unit. The logistics of all these processes will be examined and tested through a series of articles at the nonnuclear test bed at Idaho National Laboratory (INL), the Microreactor Agile Nonnuclear Experiment Testbed (MAGNET) facility. Microreactors designed to produce power of 0.1-20 MWt offer the potential for more affordable nuclear energy for a range of applications. In a heat pipe microreactor, heat pipes, fuel rods, and/or moderator are intermixed in the reactor core assembly. Heat pipes extend from the core region into the heat removal section where the power conversion unit working fluid flows through holes or channels, transferring heat from the heat pipes to the working fluid. In a gas-cooled microreactor, gas flows through the solid monolith region and up into the heat exchanger region, transferring heat to the working fluid. For initial testing, the heat removal working fluid can be a low pressure gas for testing that addresses thermal stresses. In the final application, heat addition to the power conversion working fluid typically occurs at high pressure, supporting operation of an air-Brayton, supercritical CO 2 (SCO2), or He-recuperated Brayton cycle. Various stages of the steps above will be demonstrated through the tests described in this report.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improving Ni-Based SOFC Anode Resilience and Durability through Secondary Phase Formation

The project used a multi-disciplinary approach to test test if 2° materials, added to traditional cermet components, enhanced SOFC mechanical strength, anode resilience and durability when subjected to electrochemical and environmental redox cycling. Findings from fracture testing, electrochemical studies and operando Raman spectroscopy measurements demonstrated that aluminum titanate (Al 2 TiO 5 or ALT) mechanically mixed with NiO-YSZ cermets confers superior mechanical strength and slower degradation rates under polarization. No deleterious effects from ALT in conversion efficiency were observed. Specific accomplishments included the following: (1) Refined methods used to fabricate ALT enhanced anodes into bi-layer anode supports to achieve high power densities; (2) Compared the effects of adding ALT mechanically to Ni-YSZ powders prior to anode fabrication with adding ALT through infiltration and co-infiltration of YSZ scaffolds; (3) Tested the resilience of these novel materials to electrochemical and environmental redox cycling and thermal stresses commonly encountered in functioning SOFCs; and (4) Characterized the ability of ALT to improve the carbon tolerance of Ni-YSZ anodes operating with dry methane.

01 COAL, LIGNITE, AND PEAT↗

Example Evaluation of a Representative Heat Pipe Test Article Design for Structural Acceptability using ASME Design Rules

This report describes a design analysis of a test article mimicking a core block of a heat-pipe mi-croreactor using the ASME Boiler & Pressure Vessel Code Section III, Division 5, Subsection HB, Subpart B rules. These rules cover the design and construction of elevated temperature nu-clear reactor structural components, like the core block of a heat-pipe microreactor emulated by the test article. The purposes of the report are to: (1) provide a step-by-step example of applying the ASME rules to a reasonable core block geometry and corresponding loading conditions, (2) to provide design feedback on the test article, and (3) to evaluate the ASME rules for use in the design of complex heat-pipe microreactor components. The test article design has a relatively short ASME design life, limited by high thermal stresses. The current ASME rules are adequate for evaluating the core block component designs, though they could be optimized to increase the design efficiency and reduce the amount of designer/analyst time required to execute the design process. The report covers both the current, 2019 edition ASME rules and modified, currently unapproved, rules designed to improve the design process for components with complex geometries and high secondary stresses, like the core block test article.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Initial microstructural model for creep-fatigue damage in Grade 91 steel

This report describes an initial Crystal Plasticity Finite Element Method (CPFEM) model for cyclic plasticity and damage in Grade 91 steel. The objective of this work is to develop a framework for modeling creep-fatigue interaction in Grade 91 steel to better predict the onset of damage in high temperature microreactor components. Many microreactor concepts envision low operating pressures but relatively high thermal stresses. Under these conditions, creep-fatigue will likely be the dominant design failure mechanism. Physically based models, like the one under development here, could lead to a better understanding of creep-fatigue mechanisms and the effect of stress multiaxiality and hold time on creep-fatigue damage. In turn, this could lead to more efficient microreactor component designs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sample problems for Section III, Division 5 design by inelastic analysis of Grade 91 components

This report works through two sample design analyses of representative Grade 91 components using the ASME Boiler & Pressure Vessel Code Section III, Division 5, Appendix HBB-T rules for the strain and deformation and creep-fatigue design criteria using a design by inelastic analysis approach. The component geometries and loadings were selected to span a wide variety of potential applications. The sample components are an endplate geometry, which is fairly representative of typical pressure vessel construction, and a core block, representing a critical component in a heat pipe microreactor, which has a complicated geometry and complex thermal stress history. These sample problems serve several functions. First, they are complete worked examples of how to apply the current design by inelastic analysis rules. Second, they serve as test cases to evaluate the current rules and provide feedback on how they could be optimized to deal with complicated component geometries or to be better automated in modern finite element analysis software. Finally, the analysis here uses an inelastic constitutive model for Grade 91 developed by Argonne National Laboratory and proposed for inclusion in the ASME Boiler & Pressure Vessel Code Section III, Division 5 rules as a reference constitutive model. Using this constitutive model in the sample problem analyses tests the model in the context of the ASME Code rules. The final conclusions of this report are that the material model and the current Code rules are satisfactory, but that the Code rules could be optimized to simplify automation and reduce over conservatism. Future work should address the specific optimization topics discussed in this report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interaction of Concentrated (68%) Aqueous Nitric Acid Solutions with Cheesecloth: A TGA-DSC-MS Study

The exposure of cotton cheesecloth to concentrated aqueous solutions of nitric acid reduced the onset of combustion by 30-40°C (from ~350°C to ~310°C) relative to that of both unexposed cheesecloth and cheesecloth that was rinsed immediately following exposure to the same solution. Cheesecloth exposed to concentrated (68%) nitric acid underwent three exothermic pre-combustion reactions which onset at 125-135°C, 160- 170°C and 200-210°C. These reactions give off mostly water vapor, with lesser amounts of NO and carbon dioxide. Exposure to concentrated nitric acid damages the cellulose polymers, oxidizing them, reducing them in length, and increasing their reactivity in response to thermal stress. Cheesecloth which was rinsed after exposure behaved similarly to unexposed cheesecloth, indicating that NC was not formed on exposure to the concentrated aqueous nitric acid solution. The addition of a 239Pu – 241Am spike in an aqueous nitric – hydrofluoric solution to the cheesecloth reduced the onset temperature of the first exothermic reaction to 126°C and lowered the onset temperature of combustion from ~310°C to ~275°C. When dried on to cellulose substrates in the presence of excess nitrate, metal ions may act as oxidizers, or may catalyze the oxidation of the carbonaceous material, lowering ignition temperatures. No evidence for the formation of nitrocellulose following the exposure of cheesecloth to nitric acid was observed during this study

36 MATERIALS SCIENCE↗

Status of Additive Manufacturing Capabilities for Processing Refractory Alloys Under the Mo-99 Program

The enriched 100 Mo target, denoted as aMo, that Northstar Medical Radioisotopes is developing to produce 99 Mo from an accelerator-based method is a disk-type geometry with a 0.5–0.715 mm thickness and a 29 mm outer diameter. A press and sinter method was adopted to fabricate these samples from aMo powder feedstock. Inherent porosity from the press and sinter method makes the disks more easily dissolvable during 99 Mo postprocessing. However, the disk-type geometry will be subject to thermal stresses due to temperature variations once the geometry is in line with the accelerated electron beam, causing warping and possible failure. Additive manufacturing (AM) processes such as laser powder bed fusion (LPBF) enable the manufacturing of custom, complex geometries that may otherwise be difficult to produce with more conventional methods (e.g., press and sinter approach). Therefore, the National Nuclear Security Administration’s Molybdenum-99 Program invested in developing an AM facility dedicated to processing and printing refractory powders. This report details the LPBF process, how irregular refractory powder can be prepared for LPBF, and the equipment that is available to support the program.

36 MATERIALS SCIENCE↗

Well-Controlled Hydro-thermo-chemical Stimulation of a Coso Geothermal Well to Enhance Productivity

The goal of this project was to demonstrate controlled fracturing and permeability increase to enhance resource production and power generation at Coso. It was planned to stimulate at least two intervals in the Well 73-18RD with zonal isolation using advanced high-temperature packer technology. The anticipation was that a hydraulic fracture would form in one zone and in the second zone natural fractures would reopen, shear and extend, thereby increasing fluid communication in the field. In both cases, the intent was to carefully design the stimulation to take advantage of the relative roles of hydraulic pressure, thermal stress and chemical (“hydro-thermo-chemical”) dissolution. The project had planned to use the Welltec Annular Barrier (WAB) system developed as part of another DOE-funded project which was on schedule to be ready for field deployment. If successful, the Coso Operating Company would incorporate this approach into their ongoing well maintenance in other wells increasing the total MWs produced. The project had multiple tasks and the objective of Task 1 was to develop a workover plan, to build a geologic model, to design a stimulation program, and to work with the operating and services companies to develop a detailed budget and obtain the necessary permits and sundry notices. In Phase 2 the workover plan would be implemented, the designed stimulation would be carried out, and subsequently the well would logged and tested to measure the impact of stimulation. Per sponsor request, a Pre-Task 1 activity with a Go/No Go decision point was scheduled in Task 1.

02 PETROLEUM↗

Technology Maturation of Wireless Harsh Environment Sensors For Improved Condition Based Monitoring Of Coal Fired Power Generation

The overall goal of this project was to demonstrate and develop the usage of high-temperature (HT) harsh-environment (HE) wireless surface acoustic wave resonator (SAWR) sensor technology to promote reliable maintenance through condition-based maintenance (CBM) for field applications in harsh service conditions associated with power plant environments. The project aimed to advance the HT HE wireless SAWR sensor technology from TRL 5 to TRL 7. In addition to HT HE wireless temperature sensing, efforts were dedicated during this project to investigate, develop and increase the TRL from 3 to 5 for the following technologies: (a) HT HE strain sensors to address additional CBM monitoring needs, such as boiler tube mechanical / thermal stresses, which can provide early indications for boiler tube cracking and failure; and (b) HT aluminum nitride (AlN) and scandium aluminum nitride (ScAlN) based piezoelectric thin film fabrication and implementation of SAW sensors, with the goal of releasing the need to use single crystal piezoelectric materials for SAWRs and thus broaden possible technology applications to non-planar and harder to modify surfaces. To achieve the goals mentioned above, UMaine and its partner, Environetix Technologies Corporation, established partnerships with the following power plants: Longview Power (Maidsville, WV), a coal-fired power plant; Penobscot Energy Recovery Corp (PERC, Orrington, ME), a waste-to-energy power plant; and the UMaine Steam Plant (Orono, ME), an oil / natural gas power plant. To realize wireless HT HE SAWR sensor systems in these harsh service conditions, the University of Maine research team worked with Environetix and these power plants to define, design, fabricate, test and validate a mature prototype wireless temperature SAWR sensor system for boiler tube applications within the HT HE of the reheater pass damper chamber to directly and wirelessly monitor the temperature at eighteen independent boiler tube locations. The system included three levels, or “tiers”, of wireless communication to enable remote monitoring: Tier 1, the wireless link in the reheater pass damper chamber directly accessing the sensors on the boilers; Tier 2, the wireless local area network link, transmitting processed sensor information within the power plant to the Tier 3, a commercial wireless signal carrier company for secure remote data monitoring outside of the power plant. Regarding the wireless sensor system installed at Longview Power, temperature information from the boilers was continuously transmitted from the Longview boilers at Maidsville, WV, to Environetix headquarters, Orono, ME, over a 34 month period, when the system was finally decommissioned. Strain sensors and piezoelectric ScAlN thin film sensors were successfully installed on the exhaust duct at the UMaine Steam Power plant. The advances in wireless strain sensors and thin film piezoelectric film fabrication and testing were performed mostly in UMaine laboratories and field tested at the UMaine Steam Plant, due to its close proximity to UMaine/Environetix, access to the plant facility, and due to difficulties in accessing the other power plants during the COVID shut-down period. The project accomplished the TRL level increase of the targeted CBM technologies through the successful fabrication, installation, test, and validation of dedicated and commercial wireless sensor systems, utilizing the three different power plants. The outcomes of this project, including the wireless sensor data capability, are expected to yield an advance for CBM in harsh power plant environments. The reduction of maintenance costs, improved safety during plant operation, and increased power plant efficiency will lead to increased revenues (i.e., fewer forced outages) due to better process monitoring enabled by the wireless HT HE SAWR temperature sensor technology.

20 FOSSIL-FUELED POWER PLANTS↗

Divertor Component Testing

Power exhaust is an immense challenge in tokamaks. Commonwealth Fusion Systems (CFS), in collaboration with MIT and others, is working on the design of a compact (R 0 = 1.85 m), high-field (B 0 = 12 T) tokamak for the demonstration of net fusion energy, called SPARC. Empirical scaling laws indicate that the unmitigated heat flux in the boundary plasma will exceed 10 GW/m 2 . Such high heat fluxes will be a formidable challenge. The scope of this work is to utilize the HHF testing expertise maintained by ORNL, used in support of NSTX-U and to demonstrate the thermal performance of tungsten-coated graphitic foam targets, to help CFS and its collaborators to assess the performance of (1) base materials (tungsten and its alloys) and (2) divertor mockups under SPARC-like divertor heat flux conditions. These activities will be performed by ORNL personnel using electron beam exposure facilities at the Pennsylvania State University’s Applied Research Laboratory (ARL). ARL is a Department of Defense University Affiliated Research Center where ORNL has successfully executed NSTX-U and graphitic foam high heat flux testing using electron beam (e-beam) facilities, which is a nonstandard service. For the assessment of base materials, CFS will do an initial thermal analysis, in consultation with ORNL, to understand under what scenarios the materials are most likely to fail. CFS will supply to ORNL various tungsten-based material samples to test with testing taking 3 weeks. ORNL will thermally stress the samples under SPARC divertor-like conditions to either failure or to a prescribed number of pulses. ORNL will record experimental data, including IR surface temperature and embedded thermocouple readings, and report results to CFS

36 MATERIALS SCIENCE↗

Simulations Supporting the Development of Northstar's Indirect Beam Parameters Monitoring System

NorthStar Medical Radioisotopes, LLC is planning to produce the important medical radioisotope molybdenum-99 (Mo-99), the parent of technetium-99m (Tc-99m), through photonuclear reactions in molybdenum-100 (Mo-100). In this approach, a target comprising multiple thin disks of enriched molybdenum metal is bombarded with a 40-MeV electron beam. Electrons impinged on the molybdenum target produce bremsstrahlung X-rays that cause the nuclear reaction. Because enriched Mo-100 is expensive, there is a desire to utilize as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (and heat deposition in the target), which creates challenging requirements for the cooling of the target. The critical part of the target is the target window. It separates the high-pressure helium cooled target from the vacuum beamline and the subject of structural and thermal stress. The temperature of the target window is proportional to the energy density deposited by the beam, so it is critical to maintain the desired beam profile on the target window. The feasibility of indirectly monitoring the maximum energy density of the beam on the beam window through beam losses at the main collimator (Collimator) before the production target was verified. A model of the NorthStar beam transport line was constructed for this purpose using MAD-X and Tao/Bmad codes. Beam optics were computed for the standard operational scenario, followed by an investigation involving approximately 400 cases with parameter variations in the last tuning quadrupoles. This was done to assess the correlation between losses in the collimator and the peak energy density on the target. We developed a model to explore the potential application of Optical transition radiation (OTR) for controlling beam parameters in the NorthStar beam delivery system. This model was based on a generic formula derived from the fundamental solution of the inhomogeneous wave equation of the vector potential, and allowed us to consider various surfaces, even those with irregular or random features, using numerical integration. We applied the model to OTR generated by relativistic electrons impacting an Inconel® 718 beam window. We examined cases with different levels of the window’s surface roughness, ranging from 0.5 to 3.0 microns of root square mean (RMS) deviation. The results of the OTR simulations provided distributions of OTR photons that can be used to study the limitations of optical systems for controlling beam parameters.

43 PARTICLE ACCELERATORS↗

Probing Fundamental Mechanisms of Plastic Deformation with High Energy X-rays (Final Progress Report)

Overall, substantial progress was made on developing BCDI techniques in the direction of imaging defects in multi-crystal samples. Section 2.1 describes a new method to reconstruct the 3D atomic displacement field within a grain from multiple coherently resolved diffraction peaks. The key development is the ability to recover a best fit to the grain shape at the same time as the internal displacement (strain) variation with no prior knowledge of the microstructure. This is complemented by the development of a method, Sec. 2.2, to separate out sets of Laue reflections that belong to a single grain (and thus be able to index its orientation) in the commonly encountered situation in which the beam illuminates several grains in a given location. This is essential for enabling collection of coherent diffraction data (at APS 34-ID-C) from neighboring grains. All experiments depend on the quality of samples used. Although good progress has been made with thin film samples, we are working with a broader range of geometries. A new sample design uses a high-Z metal (e.g., Pt) deposited in a sub-micron trench in a low-Z metal (e.g., Al) so that the grain size is prevented from exceeding the current limit for BCDI. We also report in section 3.1 on successfully applying NF-HEDM to a fine-grain Mg sample that would normally be considered out of scope for the method. This represents progress towards being able to map out polycrystalline samples in 3D before performing BCDI on individual grains. We further report in section 3.2 on preliminary NF-HEDM characterization of a sample of UO2 that has sub-micron grains; the data imply the capability of mapping fine-grain polycrystals at 1-ID-E, again for the purposes of BCDI in the bulk. Lastly, our plan is to load grains in polycrystalline samples by inducing thermal stress. We also report the experimental measurements of the Ti- 6Al-4V alloy obtained at the European Synchrotron Radiation Facility (ESRF), which had been indexed and mapped via HEDM at APS in section 9. As discussed below, however, technique development pre-occupied the team throughout the project which meant that we did not make any significant progress towards answering the original hypotheses as stated in the proposal. In summary, we assert that we have made good progress in methods and samples and future work taking advantage of this progress is likely to obtain and analyze BCDI data from multiple adjacent grains in 3D polycrystals. Obtaining such data depends on re-gaining access to the Advanced Photon Source, which is anticipated in late summer or the Fall. In all cases, work has involved close collaboration with faculty, staff, postdocs and students from Brigham Young University (BYU), the Los Alamos National Laboratory and APS beamlines 1-ID and 34-ID.

36 MATERIALS SCIENCE↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization through Integration of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗

Combustion Performance and Emissions Optimization Through Integration of a Miniaturized High-Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution of wall conditions in utility boilers. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of a coal-fired utility boiler in this project but can be applied to many other industries and applications as well. The new sensor design, leveraging the existing electrochemical noise-based monitoring system, is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data can be transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, five mMPMS were installed at a full-scale pulverized coal-fired plant, Basin Electric Power Cooperative’s Leland Olds Unit 1. The systems were demonstrated over a 6-week period during typical operation. Sensor measurements of deposit thickness were validated during the demonstration and subsequently leveraged to determine sensor-based boiler cleaning strategies. These strategies have the benefit of reduced thermal stresses on boiler tubes from over-cleaning and improved boiler water management. At the end of the project, continued development of the sensor technology was carried out at PacifiCorp’s Hunter Station. REI leveraged the permanent installation of the mMPMS in Unit 3 made possible by DOE funding on a separate program. The work at Hunter Plant focused on application of machine learning and artificial intelligence-based models for integration of sensor signals into control and optimization of Hunter Unit 3 processes.

42 ENGINEERING↗

Loss of Vacuum Condition for IER 479 [Slides]

Conservative thermal transient calculations and simulations show that a loss of vacuum condition would lead to a small (~6 °C) temperature differential across the Jemima Plates. Jemima plates would experience very low thermal stresses, well below the temperature differences of concern (>40 °C).

42 ENGINEERING↗