Observation of atomic ordering of triple-period-A and -B type in GaAsBi

We report the observation of atomic ordering of triple-period (TP)-A and -B type in low temperature (LT) grown GaAsBi alloy using transmission electron microscopy (TEM). In addition to previous reports, where only TP-A ordering was identified in III-V alloys, here, we confirm by electron diffraction, high-resolution (HR) TEM, and HR Z-contrast scanning TEM that two ordering variants coexists for LT-GaAsBi. We find that the TP-A ordering variant dominates over the TP-B variant. TP-A domains extend over 50–100 nm (projected lateral width) and are of higher perfection compared to TP-B domains. HR Z-contrast scanning TEM on different domains reveals a variation in the Bi occupancy in the (111) planes with triple period sequence. Since the formation of ordered phases has been directly linked to the occurrence of specific surface reconstructions, our results suggest a correlation between the TP-A and B type domains and the multiple stability of n × 3 and 3 × n reconstructions on the (001) surface of GaAsBi under low temperature growth.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electric field enhancement in a self-assembled 2D array of silver nanospheres

We investigate the plasmonic properties of a self-assembled 2D array of Ag nanospheres (average particle diameter/inter-particle separation distance of 9/3.7 nm). The structures of the individual particles and their assemblies are characterized using high-resolution transmission electron microscopy (HR-TEM). The plasmonic response of the nanoparticle network is probed using two-photon photoemission electron microscopy (TP-PEEM). HR-TEM and TP-PEEM statistics reveal the structure and plasmonic response of the network to be homogeneous on average. This translates into a relatively uniform surface-enhanced Raman scattering (SERS) response from biphenyl,4-4{sup ′}-dithiol (BPDT) molecules adsorbed onto different sites of the network. Reproducible, bright, and low-background SERS spectra are recorded and assigned on the basis of density functional theory calculations in which BPDT is chemisorbed onto the vertex of a finite tetrahedral Ag cluster consisting of 20 Ag atoms. A notable agreement between experiment and theory allows us to rigorously account for the observable vibrational states of BPDT in the ∼200–2200 cm{sup −1} region of the spectrum. Finite difference time domain simulations further reveal that physical enhancement factors on the order of 10{sup 6} are attainable at the nanogaps formed between the silver nanospheres in the 2D array. Combined with modest chemical enhancement factors, this study paves the way for reproducible single molecule signals from an easily self-assembled SERS substrate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Correlative transmission electron microscopy and electrical properties study of switchable phase-change random access memory line cells

Phase-change memory line cells, where the active material has a thickness of 15 nm, were prepared for transmission electron microscopy (TEM) observation such that they still could be switched and characterized electrically after the preparation. The result of these observations in comparison with detailed electrical characterization showed (i) normal behavior for relatively long amorphous marks, resulting in a hyperbolic dependence between SET resistance and SET current, indicating a switching mechanism based on initially long and thin nanoscale crystalline filaments which thicken gradually, and (ii) anomalous behavior, which holds for relatively short amorphous marks, where initially directly a massive crystalline filament is formed that consumes most of the width of the amorphous mark only leaving minor residual amorphous regions at its edges. The present results demonstrate that even in (purposely) thick TEM samples, the TEM sample preparation hampers the probability to observe normal behavior and it can be debated whether it is possible to produce electrically switchable TEM specimen in which the memory cells behave the same as in their original bulk embedded state.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Resolution enhancement in transmission electron microscopy with 60-kV monochromated electron source

Transmission electron microscopy (TEM) at low accelerating voltages is useful to obtain images with low irradiation damage. For a low accelerating voltage, linear information transfer, which determines the resolution for observation of single-layered materials, is largely limited by defocus spread, which improves when a narrow energy spread is used in the electron source. In this study, we have evaluated the resolution of images obtained at 60 kV by TEM performed with a monochromated electron source. The defocus spread has been evaluated by comparing diffractogram tableaux from TEM images obtained under nonmonochromated and monochromated illumination. The information limits for different energy spreads were precisely measured by using diffractograms with a large beam tilt. The result shows that the information limit reaches 0.1 nm with an energy width of 0.10 eV. With this monochromated source and a higher-order aberration corrector, we have obtained images of single carbon atoms in a graphene sheet by TEM at 60 kV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Crossover from disordered to core-shell structures of nano-oxide Y 2 O 3 dispersed particles in Fe

Here, molecular dynamic simulations of Y 2 O 3 in bcc Fe and transmission electron microscopy (TEM) observations were used to understand the structure of Y 2 O 3 nano-clusters in an oxide dispersion strengthened steel matrix. The study showed that Y 2 O 3 nano-clusters below 2 nm were completely disordered. Y 2 O 3 nano-clusters above 2 nm, however, form a core-shell structure, with a shell thickness of 0.5–0.7 nm that is independent of nano-cluster size. Y 2 O 3 nano-clusters were surrounded by off-lattice Fe atoms, further increasing the stability of these nano-clusters. TEM was used to corroborate our simulation results and showed a crossover from a disordered nano-cluster to a core-shell structure.

36 MATERIALS SCIENCE↗

Deformation of Néel-type skyrmions revealed by Lorentz transmission electron microscopy

Néel-type magnetic skyrmions in multilayers are promising candidates for ultra-low power spintronic devices. To image the Néel-type skyrmions using Lorentz transmission electron microscopy (L-TEM), the samples must be tilted. Thus, the external magnetic field consists of both in-plane and out-of-plane components. To date, it is still not well known on the effect of the in-plane magnetic field on the L-TEM images, leading to ambiguities in retrieving the structure of Néel-type skyrmions. Here, Néel-type skyrmions in three [Pt/Co/Ta]$_{20}$ multilayer samples, with the easy magnetization axis being tuned from the out-of-plane to the in-plane direction by increasing the Co thickness from 1.8 to 2.2 nm, are imaged. When using a smaller defocus value (-2 mm) and a higher magnification (×9100) of L-TEM, a surprising dark-bright-dark-bright double contrasted pattern, instead of the previously reported dark-bright contrasted pattern, is observed. The additional dark-bright contrasted pattern becomes more evident for thicker Co layer samples in which the magnetization axis tilts more toward the in-plane direction. Further analysis, via a combination of magnetic force microscopy experiments, micromagnetic simulations, and micromagnetic analysis to Lorentz TEM simulation, shows that the additional dark-bright features originate from the deformation of the Néel-type skyrmions within an in-plane magnetic field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of fluorite-structured ferroelectrics using transmission electron microscopy: Techniques, challenges, and recent advances

Fluorite-structured ferroelectrics, such as hafnium oxide and its alloyed variants, are key candidates for next-generation memory devices. Yet, fundamental questions about switching mechanisms, domain dynamics, and phase evolution remain open. Transmission electron microscopy (TEM) provides unique capabilities to address these challenges by simultaneously resolving the positions of anions and cations, chemical variations, and structural transformations. Recent advances—including in situ heating, electron beam-induced switching, electron energy loss spectroscopy, and differential phase contrast imaging—have revealed critical insights into phase transitions, potential switching pathways, and oxygen vacancy behavior. However, experimental barriers such as TEM sample-preparation-induced artifacts, high coercive fields, and imaging constraints persist, especially for polycrystalline films. By offering a focused overview of current TEM developments in fluorite ferroelectrics, this work outlines how TEM contributes to understanding key phenomena and proposes a roadmap for future studies.

36 MATERIALS SCIENCE↗

Thermal stability and irradiation response of nanocrystalline CoCrCuFeNi high-entropy alloy

Grain growth and phase stability of a nanocrystalline face-centered cubic (fcc) Ni 0.2 Fe 0.2 Co 0.2 Cr 0.2 Cu 0.2 high-entropy alloy (HEA), either thermally- or irradiation-induced, are investigated through in situ and post-irradiation transmission electron microscopy (TEM) characterization. Synchrotron and lab x-ray diffraction measurements are carried out to determine the microstructural evolution and phase stability with improved statistics. Under in situ TEM observation, the fcc structure is stable at 300 °C with a small amount of grain growth from 15.8 to ~20 nm being observed after 1800 s. At 500 °C, however, some abnormal growth activities are observed after 1400 s, and secondary phases are formed. Under 3 MeV Ni room temperature ion irradiation up to an extreme dose of nearly 600 displacements per atom, the fcc phase is stable and the average grain size increases from 15.6 to 25.2 nm. Lastly, grain growth mechanisms driven by grain rotation, grain boundary curvature, and disorder are discussed.

36 MATERIALS SCIENCE↗

Gyrokinetic simulations of core turbulence and thermal transport in the high-β P discharge on EAST

The properties of core turbulence and thermal transport are investigated for EAST high-β P (β P ~ 3.1) plasmas with dominant electron heating (Te/Ti > 1) via gyrokinetic simulation with the NLT code. Linear simulations identify that the electrostatic η e -driven trapped electron mode (η e -TEM) dominates in the core region (ρ< 0.7) and the ion temperature gradient (ITG) mode dominates in the out region (ρ≥ 0.7), consistent with the linear threshold analysis of micro-instabilities. Sensitivity analysis shows that the normalized electron density gradient (R/L ne ) and ITG (R/L Ti ) are two effective parameters to stabilize TEM instability. Nonlinear simulations are also carried out and compared with the experimental results, which show that the electron thermal internal transport barrier (ITB) in EAST high-β P plasma is determined by the TEM-induced turbulence. A higher zonal flow shearing rate is observed in the ITB region (0.2 < ρ < 0.34), which can regulate energy transport induced by TEM turbulence and facilitate the formation of e-ITB. A plausible positive feedback mechanism to mitigate turbulence transport and improve energy confinement via enhanced ion heating is proposed for future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New understanding of inter-ELM pedestal turbulence, transport, and gradient behavior in the DIII-D tokamak

New observations of pedestal localized turbulence in the inter-ELM period of H-mode plasmas in DIII-D show that ion temperature gradient mode scale (ITG-scale) density fluctuation (ñ) increases immediately after each ELM crash and is quickly suppressed during the increase in local E × B shear. This excitation and subsequent suppression of ITG-scale ñ can explain the previously reported anomalous ion heat flux, Qi during the ELM (Viezzer et al 2017 Nucl. Fusion 57 022020). Shorter wavelength trapped electron mode scale (TEM-scale) ñ starts to increase at a critical pedestal temperature gradient (∇Te,ped) and saturates as local E × B shear, ${T}_{\mathrm{i}}^{\mathrm{C}\mathrm{6}+}/{T}_{\mathrm{e}}$ ratio, and ∇Te,ped saturate. This TEM-scale ñ, which has the potential to cause electron (and also ion) heat transport, is consistent with driving an anomalous electron heat flux Qe, where Qe is estimated between ELMs using experimental profiles and power balance. Both ITG- and TEM-scale ñ amplitude variations with background Ti/Te and ∇ne,ped are found to be consistent with theoretical predictions of these measured density fluctuations being ITG and TEM instabilities respectively. Furthermore, these new and unique observations on the nature of turbulence and their potential contributions to electron and ion heat fluxes at different ELM periods (i.e. collapse, recovery, and saturation phases of pedestal gradients) can significantly test and improve our pedestal predictive capabilities for ITER and other future fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Scanning Transmission Electron Microscopy–Atom Probe Tomography Correlative Analysis for the Characterization of Solute-defect Interactions

Atom probe tomography (APT) and (scanning) transmission electron microscopy ((S)TEM) are complementary techniques that provide spatially resolved chemical and structural information at the atomic scale. Here, in this study, we employ two different STEM/APT correlative analysis methods to investigate Cr segregation at dislocation loops in ultra-high purity Fe–Cr alloys. APT needles for the correlative analysis were extracted either from bulk material or from thinned TEM lamellae. STEM analysis was used to determine the Burgers vectors of ion-irradiation-induced dislocation loops, while APT reconstruction of the same region revealed the Cr segregation to these loops. We extended the g•b = 0 invisibility criterion of dislocation loops from TEM mode in a lamella to STEM mode in a needle-shaped specimen. STEM and APT analysis on the same needle provide straightforward correlative analysis, although it is limited by a small observation volume. In contrast, iterative STEM analysis of TEM lamellae, followed by the selective extraction of specific regions of interest for APT analysis, expands the observation area by up to 100 times but requires additional time-consuming steps for APT needle extraction from the lamellae.

47 OTHER INSTRUMENTATION↗

Understanding Interfacial Electrochemical Reactions through in situ ec-STEM and IL-Cryo-STEM

A major criterion in the design of next generation materials for electrical energy storage applications is a comprehensive understanding of interfacial electrochemical reactions as well as correlating the structure and chemistry across site-specific electrode/electrolyte interfaces with electron, charge, and mass transport processes as they govern performance characteristics. Scanning transmission electron microscopy (STEM) based techniques have emerged as an indispensable materials characterization tool that provides high spatial resolution imaging and chemical analysis and has been effectively utilized to obtain an atomic to nanoscale view of the interfacial structure before and after electrochemical cycling. More recently, there have been several advances that now allows us to obtain more detailed mechanistic insight into evolving reactions through in situ ec-STEM and electrical biasing platforms such as in the understanding of the mechanisms of solid electrolyte interphase formation, lithium dendrite nucleation and growth mechanisms and ionic transport mechanisms within intercalation, conversion, and alloying electrode materials. Several major advantages of the in situ ec-STEM approach is the quantitative electrochemical measurement of charge passed during cycling with simultaneous analysis of the electrochemical processes with STEM imaging and diffraction. Here, while spectroscopic analysis of the electrochemical reactions products has been performed, there is the issue of beam sensitivity and therefore, Cryo-STEM imaging combined with electron energy loss spectroscopy (EELS) techniques have been employed to analyze the chemistry of the SEI and Li dendrites. In this talk, we discuss the potential for combining identical location (IL) STEM techniques with Cryo-EM. The advantage of using this approach is that the sample is placed on a conventional TEM grid and the exact same location of the specimen can be analyzed before and after quantitative electrochemical measurements. Moreover, since the sample is on the TEM grid, the grid itself can be prepared for further Cryo-TEM experiments by plunge freezing in liquid nitrogen then transferred to the Cryo-TEM under liquid nitrogen. Results obtain from these experiments can be used to enhance our scientific understanding of interfacial chemistry at electrode/electrolyte interfaces and may be useful in the design of new materials.

36 MATERIALS SCIENCE↗

Quantifying chiral exchange interaction for Néel-type skyrmions via Lorentz transmission electron microscopy

Magnetic skyrmions are topological spin textures that have been observed in bulk magnets and magnetic multilayers. For bulk magnetic materials, their noncollinear spin profiles have often been studied by using Lorentz transmission electron microscopy (TEM). We experimentally utilized Lorentz TEM imaging to study an inversion asymmetric [Pt(1.5nm)/Co(1 nm)/W(1 nm)] 8 heterostructure that exhibits Neel-type skyrmions at zero field. By tracking the evolution of skyrmion diameters as a function of magnetic fields, we determined the strength of the interfacial Dzyaloshinskii-Moriya interaction (DMI). Our results suggest that in situ Lorentz TEM imaging combined with simulations can provide valuable quantitative information about the interfacial DMI strengths, which can be helpful for optimizing skyrmion materials. Furthermore, we show that in theory, Lorentz TEM can identify the spin chirality of Neel-type skyrmions, although an experimental verification is challenging due to the relatively low signal-to-noise ratio.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In Situ Transmission Electron Microscopy: Signal processing challenges and examples

Transmission electron microscopy (TEM) is a powerful tool for imaging material structure and characterizing material chemistry. Recent advances in data collection technology for TEM have enabled high-volume and high-resolution data collection at a microsecond frame rate. Here, taking advantage of these advances in data collection rates requires the development and application of data processing tools, including image analysis, feature extraction, and streaming data processing techniques. In this article, we highlight a few areas in materials science that have benefited from combining signal processing and statistical analysis with data collection capabilities in TEM and present a future outlook on opportunities of integrating signal processing with automated TEM data analysis.

36 MATERIALS SCIENCE↗

Mitigating e-beam-induced hydrocarbon deposition on graphene for atomic-scale scanning transmission electron microscopy studies

Chemical vapor deposition (CVD) grown graphene used in (scanning) transmission electron microscopy [(S)TEM] studies must undergo a careful transfer of the one-atom-thick membrane from the growth surface (typically a Cu foil) to the TEM grid. During this transfer process, the graphene invariably becomes contaminated with foreign materials. This contamination proves to be very problematic in the (S)TEM because often >95% of the graphene is obscured, and imaging of the pristine areas results in e-beam-induced hydrocarbon deposition which further acts to obscure the desired imaging area. In this article, the authors examine two cleaning techniques for CVD grown graphene that mitigate both aspects of the contamination problem: visible contamination covering the graphene, and “invisible” contamination that deposits onto the graphene under e-beam irradiation. Furthermore, the visible contamination may be removed quickly by a rapid thermal annealing to 1200 °C in situ and the invisible e-beam-deposited contamination may be removed through an Ar/O 2 annealing procedure prior to imaging in the (S)TEM.

36 MATERIALS SCIENCE↗

Temperature-induced degradation of GaN HEMT: An in situ heating study

High-power electronics, such as GaN high electron mobility transistors (HEMTs), are expected to perform reliably in high-temperature conditions. This study aims to gain an understanding of the microscopic origin of both material and device vulnerabilities to high temperatures by real-time monitoring of the onset of structural degradation under varying temperature conditions. This is achieved by operating GaN HEMT devices in situ inside a transmission electron microscope (TEM). Electron-transparent specimens are prepared from a bulk device and heated up to 800 °C. High-resolution TEM (HRTEM), scanning TEM (STEM), energy-dispersive x-ray spectroscopy (EDS), and geometric phase analysis (GPA) are performed to evaluate crystal quality, material diffusion, and strain propagation in the sample before and after heating. Gate contact area reduction is visible from 470 °C accompanied by Ni/Au intermixing near the gate/AlGaN interface. Elevated temperatures induce significant out-of-plane lattice expansion at the SiNx/GaN/AlGaN interface, as revealed by geometry-phase GPA strain maps, while in-plane strains remain relatively consistent. Exposure to temperatures exceeding 500 °C leads to almost two orders of magnitude increase in leakage current in bulk devices in this study, which complements the results from our TEM experiment. The findings of this study offer real-time visual insights into identifying the initial location of degradation and highlight the impact of temperature on the bulk device’s structure, electrical properties, and material degradation.

36 MATERIALS SCIENCE↗

SU-G-TeP3-03: Dose Enhancement of Gold Nanoparticle in Proton Therapy: A Monte Carlo Study Based On the Transmission Electron Microscopy Imaging

Purpose: Gold nanoparticle (GNP) is a promising radiosensitizer that selectively boosts tumor dose in radiotherapy. Transmission electron microscopy (TEM) imaging observations recently revealed for the first time that GNP exists in vivo in the form of highly localized vesicles, instead of hypothetical uniform distribution. This work investigates the corresponding difference of energy deposition in proton therapy. Methods: First, single vesicles of various radii were constructed by packing GNPs (as Φ50 nm gold spheres) in spheres and were simulated, as well as a single GNP. The radial energy depositions (REDs) were scored using 100 concentric spherical shells from 0.1µm to 10µm, 0.1µm thickness each, for both vesicles and GNP, and compared. TEM images, 8 days after injection in a PC3 prostate cancer murine model, were used to extract position/dimension of vesicles, as well as contours of cytoplasmic and nucleus membranes. Vesicles were then constructed based on the TEM images. A 100 MeV proton beam was studied by using the Geant4-DNA code, which simulates all energy deposition events. Results: The vesicle REDs, normalized to the same proton energy loss as in a single GNP, are larger (smaller) than that of a single GNP when radius >2µm (<2µm). The peak increase (at about 3µm radius) is about 10% and 18% for Φ1µm and Φ1.6µm vesicles respectively, relative to a single GNP. The TEM-based simulation resulted in a larger energy deposition (by about one order of magnitude) that follows completely different pattern from that of hypothetical GNP distributions (regular dotted pattern in extracellular and/or extranucleus regions). Conclusion: The in vivo energy deposition, both in pattern and magnitude, of proton therapy is greatly affected by the true distribution of the GNP, as illustrated by the presence of GNP vesicles compared to hypothetical scenarios. Work supported by NSERC Discovery Grant #435510, Canada.

60 APPLIED LIFE SCIENCES↗

Outstanding radiation resistance of tungsten-based high-entropy alloys

A body-centered cubic W-based refractory high entropy alloy with outstanding radiation resistance has been developed. The alloy was grown as thin films showing a bimodal grain size distribution in the nanocrystalline and ultrafine regimes and a unique 4-nm lamella-like structure revealed by atom probe tomography (APT). Transmission electron microscopy (TEM) and x-ray diffraction show certain black spots appearing after thermal annealing at elevated temperatures. TEM and APT analysis correlated the black spots with second-phase particles rich in Cr and V. No sign of irradiation-created dislocation loops, even after 8 dpa, was observed. Furthermore, nanomechanical testing shows a large hardness of 14 GPa in the as-deposited samples, with near negligible irradiation hardening. Theoretical modeling combining ab initio and Monte Carlo techniques predicts the formation of Cr- and V-rich second-phase particles and points at equal mobilities of point defects as the origin of the exceptional radiation tolerance.

36 MATERIALS SCIENCE↗