Defect-free periodic structures using extreme ultraviolet Talbot lithography in a table-top system
N/A
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
N/A
Purpose: In image-guided radiotherapy, an artifact typically seen in axial slices of x-ray cone-beam computed tomography (CBCT) reconstructions is a dark region or ''black hole'' situated below the scan isocenter. The authors trace the cause of the artifact to scattered radiation produced by radiotherapy patient tabletops and show it is linked to the use of the offset-detector acquisition mode to enlarge the imaging field-of-view. The authors present a hybrid scatter kernel superposition (SKS) algorithm to correct for scatter from both the object-of-interest and the tabletop. Methods: Monte Carlo simulations and phantom experiments were first performed to identify the source of the black hole artifact. For correction, a SKS algorithm was developed that uses separate kernels to estimate scatter from the patient tabletop and the object-of-interest. Each projection is divided into two regions, one defined by the shadow cast by the tabletop on the imager and one defined by the unshadowed region. The region not shadowed by the tabletop is processed using the recently developed fast adaptive scatter kernel superposition (fASKS) method which employs asymmetric kernels that best model scatter transport through bodylike objects. The shadowed region is convolved with a combination of slab-derived symmetric SKS kernels and asymmetric fASKS kernels. The composition of the hybrid kernels is projection-angle-dependent. To test the algorithm, pelvis phantom and in vivo data were acquired using a CBCT test stand, a Varian Acuity simulator, and a Varian On-Board Imager, all of which have similar geometries and components. Artifact intensities and Hounsfield unit (HU) accuracies in the reconstructions were assessed before and after the correction. Results: The hybrid kernel algorithm provided effective correction and produced substantially better scatter estimates than the symmetric SKS or asymmetric fASKS methods alone. HU nonuniformities in the reconstructed pelvis phantom were reduced from 220 to 50 HU (i.e., 22%-5%). In the in vivo scans, the black hole artifact was reduced by up to 147 HU, a 73% improvement, and anatomical details in the prostate and rectum areas were made considerably more visible. Conclusions: Radiotherapy tabletops, which are generally flatter and larger than those used for diagnostic CT, can produce significant scatter-related artifacts. The proposed hybrid SKS algorithm accurately estimates scatter from both the object-of-interest and the patient tabletop, and resulting image uniformities and HU accuracies are greatly improved.
Purpose: Total lymphoid irradiation (TLI) is conventionally delivered through the dosimetric matching of mantle, spleen, and pelvis fields, necessitating multiple isocenters delivered through a combination of couch shifts and sliding of patients relative to the couch rendering the technique susceptible to shifting errors. To address this challenge, a novel technique for the couch indexing of TLI treatments is developed and evaluated through a multi-patient pilot trial. Methods: An immobilization device was designed consisting of a movable indexed slide board with an Exact Lok-Bar drilled into it. A Timo headrests were used fixate the head of the patient relative to the slide board. For the Varian Exact Couch™, the immobilization board was connected to the H3 notch to avoid the metal infrastructure of the couch for the delivery of the mantle and spleen fields. For tall patients the required shift for the pelvis isocenter reaches the shifting limit and the board was slid from H3 to H4 (a fixed distance of 14 cm). A total 22 patients were stratified in two groups of 11, one consisting of the conventional setup, and one group with the proposed immobilization technique. Results: The standard deviations (SD) of the couch positions in lateral, longitudinal, and vertical directions for 10 fractions for each patient in both groups were calculated. In the non-indexed group, the positioning SD ranged from 0.9 to 4.7 cm. Using our device, the positioning SD was reduced to a range of 0.2 to 0.9 cm, with the longitudinal direction showing the largest improvement. Conclusion: Matched field TLI remains error prone to geometrical misses. The feasibility of full indexing TLI treatments was validated and shown to result in a significant reduction of positioning errors.
Genome sequences of Methylobacter luteus, Methylobacter whittenburyi, Methylosarcina fibrata, Methylomicrobium agile, and Methylovulum miyakonense were generated. The strains represent aerobic methanotrophs typically isolated from various terrestrial ecosystems.
Genomic sequences are described from five novel viruses and divergent strains of Brejeira and Guaico Culex viruses from mosquitoes collected in Pantanal, Brazil, in 2010.
An expression for the binding energies of electrons in the ground state of an atom is derived on the basis of the Bohr–Sommerfeld quantization rule within the Thomas–Fermi model. The validity of this relation for all elements from neon to uranium is tested within a more perfect quantum-mechanical model with and without the inclusion of relativistic effects, as well as with experimental binding energies. As a result, the ordering of electronic levels in filled atomic shells is established, manifested in an approximate atomic-number similarity. It is proposed to use this scaling property to analytically estimate the binding energies of electrons in an arbitrary atom.
Abstract not provided.
The data set includes gamma spectroscopy peak data for measurements taken with two different high purity germanium detectors using a mixed nuclide source and a U-235 fuel rod. There are a total of 5 specific energy peaks that were analyzed for the mixed nuclide source stemming from Am-241, Cd-109, Cs-137, and Co-60. There are a total of 3 specific energy peaks that were analyzed for the U-235 fuel rod. The data set includes the calculations and results from using a linear correction factor, absolute efficiency curve, and relative efficiency curve to compare the net peaks counts from two different detectors.
The Energy Market Price Response (EMPR) service is provided by the device, which shifts demand from high price periods in the day to low price periods. The device would consume energy when prices are low and release energy (or defer consumption) when prices are high. This load shifting benefits the individual consumers and society in general by shifting consumption to periods when production resources are available at lower costs. The service could be driven by price forecasts of the day-ahead market or shorter time periods. The service could be facilitated by demand response aggregators, utilities, or other load serving entities.
An interactive plugin for Binary Ninja that resolves indirect branches/jumps in V850 software samples.
SF-25-140 atct is a lightweight, Python client for the ATcT v1 API that enables programmatic access to high-accuracy thermochemical data and turnkey reaction-enthalpy analysis. The package implements full v1 endpoint coverage (species lookup by ATcT ID, name, formula, SMILES, InChI, CAS RN; covariance queries; health checks) with robust error handling, retries, and environment-based configuration for local/production endpoints. Beyond data retrieval, atct provides rigorously implemented reaction calculators that propagate uncertainties via either (i) a conventional independent-errors method (0 K or 298.15 K) or (ii) covariance-aware propagation using provided covariances at 298.15 K. Typed data classes ensure transparent, reproducible data structures and carry ATcT Thermochemical Network (TN) version identifiers for provenance. Dual import paths and comprehensive examples facilitate integration into research pipelines, enabling reproducible thermochemical calculations, automated validation, and downstream method development.
Data package purpose: This data package was created to contain all data used in an upcoming article, "Canopy Cover and Microtopography Control Precipitation-Enhanced Thaw of Ecosystem-Protected Permafrost." In review.This data package includes: Raw output from 19 distributed temperature profilers with a thermistor every 10 cm along a 160 cm length at a measurement interval of 15 minutes (.CSV). Raw output from two soil moisture and temperature profilers (90 cm length and 120 cm length) that took composite soil moisture readings every 15 cm along the sensor length at a measurement interval of 30 minutes (.CSV). Permafrost depths were measured annually in mid-September at DTP sensor locations (.CSV) and along an across-site transect (.CSV). Environmental variables (snow depth, canopy closure, moss depth, and elevation) for all sensor locations. Real-time kinetic (RTK) GPS points showing site microtopography (.CSV).Analysis software: Our analysis was done in Matlab. File types can be used with any software.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.