Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Statistical techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

MO-C-18A-01: Advances in Model-Based 3D Image Reconstruction

Recent years have seen the emergence of CT image reconstruction techniques that exploit physical models of the imaging system, photon statistics, and even the patient to achieve improved 3D image quality and/or reduction of radiation dose. With numerous advantages in comparison to conventional 3D filtered backprojection, such techniques bring a variety of challenges as well, including: a demanding computational load associated with sophisticated forward models and iterative optimization methods; nonlinearity and nonstationarity in image quality characteristics; a complex dependency on multiple free parameters; and the need to understand how best to incorporate prior information (including patient-specific prior images) within the reconstruction process. The advantages, however, are even greater – for example: improved image quality; reduced dose; robustness to noise and artifacts; task-specific reconstruction protocols; suitability to novel CT imaging platforms and noncircular orbits; and incorporation of known characteristics of the imager and patient that are conventionally discarded. This symposium features experts in 3D image reconstruction, image quality assessment, and the translation of such methods to emerging clinical applications. Dr. Chen will address novel methods for the incorporation of prior information in 3D and 4D CT reconstruction techniques. Dr. Pan will show recent advances in optimization-based reconstruction that enable potential reduction of dose and sampling requirements. Dr. Stayman will describe a “task-based imaging” approach that leverages models of the imaging system and patient in combination with a specification of the imaging task to optimize both the acquisition and reconstruction process. Dr. Samei will describe the development of methods for image quality assessment in such nonlinear reconstruction techniques and the use of these methods to characterize and optimize image quality and dose in a spectrum of clinical applications. Learning Objectives: Learn the general methodologies associated with model-based 3D image reconstruction. Learn the potential advantages in image quality and dose associated with model-based image reconstruction. Learn the challenges associated with computational load and image quality assessment for such reconstruction methods. Learn how imaging task can be incorporated as a means to drive optimal image acquisition and reconstruction techniques. Learn how model-based reconstruction methods can incorporate prior information to improve image quality, ease sampling requirements, and reduce dose.

60 APPLIED LIFE SCIENCES↗

Polynomial meta-models with canonical low-rank approximations: Numerical insights and comparison to sparse polynomial chaos expansions

The growing need for uncertainty analysis of complex computational models has led to an expanding use of meta-models across engineering and sciences. The efficiency of meta-modeling techniques relies on their ability to provide statistically-equivalent analytical representations based on relatively few evaluations of the original model. Polynomial chaos expansions (PCE) have proven a powerful tool for developing meta-models in a wide range of applications; the key idea thereof is to expand the model response onto a basis made of multivariate polynomials obtained as tensor products of appropriate univariate polynomials. The classical PCE approach nevertheless faces the “curse of dimensionality”, namely the exponential increase of the basis size with increasing input dimension. To address this limitation, the sparse PCE technique has been proposed, in which the expansion is carried out on only a few relevant basis terms that are automatically selected by a suitable algorithm. An alternative for developing meta-models with polynomial functions in high-dimensional problems is offered by the newly emerged low-rank approximations (LRA) approach. By exploiting the tensor–product structure of the multivariate basis, LRA can provide polynomial representations in highly compressed formats. Through extensive numerical investigations, we herein first shed light on issues relating to the construction of canonical LRA with a particular greedy algorithm involving a sequential updating of the polynomial coefficients along separate dimensions. Specifically, we examine the selection of optimal rank, stopping criteria in the updating of the polynomial coefficients and error estimation. In the sequel, we confront canonical LRA to sparse PCE in structural-mechanics and heat-conduction applications based on finite-element solutions. Canonical LRA exhibit smaller errors than sparse PCE in cases when the number of available model evaluations is small with respect to the input dimension, a situation that is often encountered in real-life problems. By introducing the conditional generalization error, we further demonstrate that canonical LRA tend to outperform sparse PCE in the prediction of extreme model responses, which is critical in reliability analysis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct comparison of using a Z -transformation instead of the traditional $Q^2$ for extraction of the proton radius from $e-p$ scattering data

A discrepancy in the determination of the proton’s charge radius, r p , between muonic hydrogen spectroscopy versus classic atomic spectroscopy and electron scattering data has become known as the proton radius puzzle. Extractions of r p from electron scattering data require determination of the slope of the proton’s charge form factor, $G$$^{p}_{E}$, in the limit of Q 2 → 0 through fitting and extrapolation. Some works have presented the Z-transformation fitting technique as the best choice for this type of extraction due to the true functional form of $G$$^{p}_{E}$ being mathematically guaranteed to exist within the parameter-space of the fit function. In this work, we test this claim by examining the mathematical bias and variances introduced by this technique as compared to the more traditional Q 2 fits using statistically sampled $G$$^{p}_{E}$ parameterizations with known input radii. Furthermore, our tests conclude that the quality of the Z-transformation technique depends on the range of data used. In the case of new experiments, the fit function and technique should be selected in advance by generating realistic pseudodata and assessing the power of different techniques.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development and application of a standardized flow measurement uncertainty analysis framework to various low-head short-converging intake types across the United States federal hydropower fleet

Turbine discharges at low-head short converging intakes are difficult to measure accurately. The proximity of the measurement section to the intake entrance admits large uncertainties related to asymmetry of the velocity profile, swirl, and turbulence. Existing turbine performance codes [10, 24] do not address this special case and published literature is largely silent on rigorous evaluation of uncertainties associated with this measurement context. The American Society of Mechanical Engineers (ASME) Committee investigated the use of Acoustic transit time (ATT), Acoustic scintillation (AS), and Current meter (CM) in a short converging intake at the Kootenay Canal Generating Station in 2009. Based on their findings, a standardized uncertainty analysis (UA) framework for velocity-area method (specifically for CM measurements) is presented in this paper given the fact that CM is still the most fundamental and common type of measurement system. Typical sources of systematic and random errors associated with CM measurements are investigated, and the major sources of uncertainties associated with turbulence and velocity fluctuations, numerical velocity integration technique (bi-cubic spline), and the number and placement of current meters are being considered for an evaluation. Since the velocity measurements in a short converging intake are associated with complex nonlinear and time varying uncertainties (e.g., Reynolds stress in fluid dynamics), simply applying the law of propagation of uncertainty is known to overestimate the measurement variance while the Monte Carlo method does not. Therefore, a pseudo-Monte Carlo simulation method (random flow generation technique [8]) which was initially developed for the purpose of establishing upstream or initial conditions in the Large-Eddy Simulation (LES) and the Direct Numerical Simulation (DNS) is used to statistically determine uncertainties associated with turbulence and velocity fluctuations. This technique is then combined with a bi-cubic spline interpolation method which converts point velocities into a continuous velocity distribution over the measurement domain. Subsequently the number and placement of current meters are simulated to investigate the accuracy of the estimated flow rates using the numerical velocity-area integration method outlined in ISO 3354 [12]. The authors herein consider that statistics on generated flow rates processed with bi-cubic interpolation and sensor simulations are the combined uncertainties which already accounted for the effects of all those three uncertainty sources. A preliminary analysis based on the current meter data obtained through an upgrade acceptance test of a single unit located in a mainstem plant has been presented.

Smith, Brennan T↗

Signal/noise enhancement strategies for stochastically estimated correlation functions

We develop here strategies for enhancing the signal/noise ratio for stochastically sampled correlation functions. The techniques are general and offer a wide range of applicability. We demonstrate the potential of the approach with a generic two-state system and then explore the practical applicability of the method for single hadron correlators in lattice quantum chromodynamics. In the latter case, we determine the ground state energies of the pion, proton, and delta baryon, as well as the ground and first excited state energy of the rho meson using matrices of correlators computed on an exemplary ensemble of anisotropic gauge configurations. In the majority of cases, we find a modest reduction in the statistical uncertainties on extracted energies compared to conventional variational techniques. However, in the case of the delta baryon, we achieve a factor of 3 reduction in statistical uncertainties. The variety of outcomes achieved for single hadron correlators illustrates an inherent dependence of the method on the properties of the system under consideration and the operator basis from which the correlators are constructed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Bladder radiotherapy treatment: A retrospective comparison of 3-dimensional conformal radiotherapy, intensity-modulated radiation therapy, and volumetric-modulated arc therapy plans

To examine tumor's and organ's response when different radiotherapy plan techniques are used. Ten patients with confirmed bladder tumors were first treated using 3-dimensional conformal radiotherapy (3DCRT) and subsequently the original plans were re-optimized using the intensity-modulated radiation treatment (IMRT) and volumetric-modulated arc therapy (VMAT)-techniques. Targets coverage in terms of conformity and homogeneity index, TCP, and organs' dose limits, including integral dose analysis were evaluated. In addition, MUs and treatment delivery times were compared. Better minimum target coverage (1.3%) was observed in VMAT plans when compared to 3DCRT and IMRT ones confirmed by a statistically significant conformity index (CI) results. Large differences were observed among techniques in integral dose results of the femoral heads. Even if no statistically significant differences were reported in rectum and tissue, a large amount of energy deposition was observed in 3DCRT plans. In any case, VMAT plans provided better organs and tissue sparing confirmed also by the normal tissue complication probability (NTCP) analysis as well as a better tumor control probability (TCP) result. Our analysis showed better overall results in planning using VMAT techniques. Furthermore, a total time reduction in treatment observed among techniques including gantry and collimator rotation could encourage using the more recent one, reducing target movements and patient discomfort.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Calibration System of the E989 Experiment at Fermilab

The muon anomaly aµ is one of the most precise quantity known in physics experimentally and theoretically. The high level of accuracy permits to use the measurement of aµ as a test of the Standard Model comparing with the theoretical calculation. After the impressive result obtained at Brookhaven National Laboratory in 2001 with a total accuracy of 0.54 ppm, a new experiment E989 is under construction at Fermilab, motivated by the diff of aexp SM µ − aµ ∼ 3σ. The purpose of the E989 experiment is a fourfold reduction of the error, with a goal of 0.14 ppm, improving both the systematic and statistical uncertainty. With the use of the Fermilab beam complex a statistic of × 21 with respect to BNL will be reached in almost 2 years of data taking improving the statistical uncertainty to 0.1 ppm. Improvement on the systematic error involves the measurement technique of ωa and ωp, the anomalous precession frequency of the muon and the Larmor precession frequency of the proton respectively. The measurement of ωp involves the magnetic field measurement and improvements on this sector related to the uniformity of the field should reduce the systematic uncertainty with respect to BNL from 170 ppb to 70 ppb. A reduction from 180 ppb to 70 ppb is also required for the measurement of ωa; new DAQ, a faster electronics and new detectors and calibration system will be implemented with respect to E821 to reach this goal. In particular the laser calibration system will reduce the systematic error due to gain fl of the photodetectors from 0.12 to 0.02 ppm. The 0.02 ppm limit on systematic requires a system with a stability of 10−4 on short time scale (700 µs) while on longer time scale the stability is at the percent level. The 10−4 stability level required is almost an order of magnitude better than the existing laser calibration system in particle physics, making the calibration system a very challenging item. In addition to the high level of stability a particular environment, due to the presence of a 14 m diameter storage ring, a highly uniform magnetic field and the detector distribution around the storage ring, set specific guidelines and constraints. This thesis will focus on the final design of the Laser Calibration System developed for the E989 experiment. Chapter 1 introduces the subject of the anomalous magnetic moment of the muon; chapter 2 presents previous measurement of g-2, while chapter 3 discusses the Standard Model prediction and possible new physics scenario. Chapter 4 describes the E989 experiment. In this chapter will be described the experimental technique and also will be presented the experimental apparatus focusing on the improvements necessary to reduce the statistical and systematic errors. The main item of the thesis is discussed in the last two chapters: chapter 5 is focused on the Laser Calibration system while chapter 6 describes the Test Beam performed at the Beam Test Facility of Laboratori Nazionali di Frascati from the 29th February to the 7th March as a final test for the full calibrations system. An introduction explain the physics motivation of the system and the diff t devices implemented. In the final chapter the setup used will be described and some of the results obtained will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Statistical analysis of AFM topographic images of self-assembled quantum dots

To obtain statistical data on quantum-dot sizes, AFM topographic images of the substrate on which the dots under study are grown are analyzed. Due to the nonideality of the substrate containing height differences on the order of the size of nanoparticles at distances of 1-10 {mu}m and the insufficient resolution of closely arranged dots due to the finite curvature radius of the AFM probe, automation of the statistical analysis of their large dot array requires special techniques for processing topographic images to eliminate the loss of a particle fraction during conventional processing. As such a technique, convolution of the initial matrix of the AFM image with a specially selected matrix is used. This makes it possible to determine the position of each nanoparticle and, using the initial matrix, to measure their geometrical parameters. The results of statistical analysis by this method of self-assembled InAs quantum dots formed on the surface of an AlGaAs epitaxial layer are presented. It is shown that their concentration, average size, and half-width of height distribution depend strongly on the In flow and total amount of deposited InAs which are varied within insignificant limits.

36 MATERIALS SCIENCE↗

Highly accelerated life testing (HALT): A review from a statistical perspective

Despite its use in one form or another for at least four decades, HALT and related techniques [e.g., highly accelerated-stress screening (HASS) and stress audits (HASA)] are not well understood within the statistical community and remain controversial. This largely reflects a conflict in motivation between engineers, testing under harsh conditions to discover and eliminate failure modes, and statisticians, taking a more cautious approach to develop quantitative estimates of parameters such as mean time between failures (MTBF). Here, this review article will clarify HALT concepts and methods and explain where it fits within the universe of methods that involve the application of accelerating factors to compress the time required to evaluate or enhance product reliability. A major distinction is between methods such as HALT, a high-stress test-analyze-fix-test iterative process directed at improving reliability by discovering and fixing weak points in a design, and quantitative accelerated life testing (QALT), whose goal is the estimation of product life for a fixed design. We discuss methods such as physics of failure that offer some hope of bridging the gap between the qualitative nature of HALT, and purely quantitative statistical methods. We present a variety of engineering applications of HALT including metal fatigue, piping and pressure vessels, structural damage, radiation damage, and rotating machinery. We also discuss potential synergies between HALT and QALT, such as rapid identification, through HALT, of failure modes requiring quantitative analysis. For further study, extensive references to the applicable literature are provided as well as an appendix that describes related methods.

97 MATHEMATICS AND COMPUTING↗

Smart Sampling and HPC-based Probabilistic Look-ahead Contingency Analysis Implementation and its Evaluation with Real-world Data

This paper describes a probabilistic look-ahead contingency analysis application that incorporates smart sampling and high-performance computing (HPC) techniques. Smart sampling techniques are implemented to effectively represent the structure and statistical characteristics of uncertainty introduced by different sources in the power system. They can significantly reduce the data set size required for multiple look-ahead contingency analyses, and therefore reduce the time required to compute them. High-performance-computing (HPC) techniques are used to further reduce computational time. These two techniques enable a predictive capability that forecasts the impact of various uncertainties on potential transmission limit violations. The developed package has been tested with real world data from the Bonneville Power Administration. Case study results are presented to demonstrate the performance of the applications developed.

high performance computing↗

Determination of B*B{pi} coupling in unquenched lattice QCD

The B*B{pi} coupling is a fundamental parameter of chiral effective Lagrangian with heavy-light mesons and can constrain the chiral behavior of f{sub B}, B{sub B}, and the B{yields}{pi}l{nu} form factor in the soft pion limit. We compute the B*B{pi} coupling with the static heavy quark and the O(a)-improved Wilson light quark. Simulations are carried out with n{sub f}=2 unquenched 12{sup 3}x24 lattices at {beta}=1.80 and 16{sup 3}x32 lattices at {beta}=1.95 generated by the CP-PACS collaboration. To improve the statistical accuracy, we employ the all-to-all propagator technique and the static quark action with smeared temporal link variables. These methods successfully work also on unquenched lattices, and determine the B*B{pi} coupling with 1%-2% statistical accuracy on each lattice spacing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Collaborative Exploration of Scientific Datasets Using Immersive and Statistical Visualization: Preprint

We discuss the value of collaborative, immersive visualization for the exploration of scientific datasets and review techniques and tools that have been developed and deployed at the National Renewable Energy Laboratory (NREL). We believe that collaborative visualizations linking statistical interfaces and graphics on laptops and high-performance computing (HPC) with 3D visualizations on immersive displays (head-mounted displays and large-scale immersive environments) enable scientific workflows that further rapid exploration of large, high-dimensional datasets by teams of analysts. We present a framework, PlottyVR, that blends statistical tools, general-purpose programming environments, and simulation with 3D visualizations. To contextualize this framework, we propose a categorization and loose taxonomy of collaborative visualization and analysis techniques. Finally, we describe how scientists and engineers have adopted this framework to investigate large, complex datasets.

collaborative visualization↗

Geometry tagging for heavy ions at JLEIC

Geometry tagging is an experimental analysis technique for selecting event samples where one can, on a statistical basis, control the geometry of the collision in order to make more incisive physics measurements. Several physics measurements at the EIC would benefit significantly from the use of this technique, including studies of gluon anti-shadowing, studies of parton propagation, attenuation and hadronization in the nucleus, and ultimately the search for parton saturation. The JLEIC full-acceptance detector, with full acceptance to forward-going neutrons, protons and nuclear fragments and a high data-taking rate is ideally suited to such geometry tagging. We improve, tune, and apply existing modeling codes, BeAGLE, Sartre, and GEMC, and detector descriptions to study this physics.

Morozov, Vasiliy↗

Dosimetric Comparison of 6 MV and 15 MV Single Arc Rapidarc to Helical TomoTherapy for the Treatment of Pancreatic Cancer

We conducted a planning study to compare Varian's RapidArc (RA) and helical TomoTherapy (HT) for the treatment of pancreatic cancer. Three intensity-modulated radiotherapy (IMRT) plans were generated for 8 patients with pancreatic cancer: one using HT with 6-MV beam (Plan{sub HT6}), one using single-arc RA with 6-MV beam (Plan{sub RA6}), and one using single-arc RA with 15-MV beam (Plan{sub RA15}). Dosimetric indices including high/low conformality index (CI{sub 100%}/CI{sub 50%}), heterogeneity index (HI), monitor units (MUs), and doses to organs at risk (OARs) were compared. The mean CI{sub 100%} was statistically equivalent with respect to the 2 treatment techniques, as well as beam energy (0.99, 1.01, and 1.02 for Plan{sub HT6}, Plan{sub RA6}, and Plan{sub RA156,} respectively). The CI{sub 50%} and HI were improved in both RA plans over the HT plan. The RA plans significantly reduced MU (MU{sub RA6} = 697, MU{sub RA15} = 548) compared with HT (MU{sub HT6} = 6177, p = 0.008 in both cases). The mean maximum cord dose was decreased from 29.6 Gy in Plan{sub HT6} to 21.6 Gy (p = 0.05) in Plan{sub RA6} and 21.7 Gy (p = 0.04) in Plan{sub RA15}. The mean bowel dose decreased from 17.2 Gy in Plan{sub HT6} to 15.2 Gy (p = 0.03) in Plan{sub RA6} and 15.0 Gy (p = 0.03) Plan{sub RA15}. The mean liver dose decreased from 8.4 Gy in Plan{sub HT6} to 6.3 Gy (p = 0.04) in Plan{sub RA6} and 6.2 Gy in Plan{sub RA15}. Variations of the mean dose to the duodenum, kidneys, and stomach were statistically insignificant. RA and HT can both deliver conformal dose distributions to target volumes while limiting the dose to surrounding OARs in the treatment of pancreatic cancer. Dosimetric advantages might be gained by using RA over HT by reducing the dose to OARs and total MUs used for treatment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Discovering Active Subspaces for High-Dimensional Computer Models

Dimension reduction techniques have long been an important topic in statistics, and active subspaces (AS) have received much attention this past decade in the computer experiments literature. The most common approach towards estimating the AS is to use Monte Carlo with numerical gradient evaluation. While sensible in some settings, this approach has obvious drawbacks. Recent research has demonstrated that active subspace calculations can be obtained in closed form, conditional on a Gaussian process (GP) surrogate, which can be limiting in high-dimensional settings for computational reasons. In this paper, we produce the relevant calculations for a more general case when the model of interest is a linear combination of tensor products. These general equations can be applied to the GP, recovering previous results as a special case, or applied to the models constructed by other regression techniques including multivariate adaptive regression splines (MARS). Furthermore, using a MARS surrogate has many advantages including improved scaling, better estimation of active subspaces in high dimensions and the ability to handle a large number of prior distributions in closed form. In one real-world example, we obtain the active subspace of a radiation-transport code with 240 inputs and 9,372 model runs in under half an hour.

97 MATHEMATICS AND COMPUTING↗

Leveraging interpolation models and error bounds for verifiable scientific machine learning

Effective verification and validation techniques for modern scientific machine learning workflows are challenging to devise. Statistical methods are abundant and easily deployed, but often rely on speculative assumptions about the data and methods involved. Error bounds for classical interpolation techniques can provide mathematically rigorous estimates of accuracy, but often are difficult or impractical to determine computationally. Here, in this work, we present a best-of-both-worlds approach to verifiable scientific machine learning by demonstrating that (1) multiple standard interpolation techniques have informative error bounds that can be computed or estimated efficiently; (2) comparative performance among distinct interpolants can aid in validation goals; (3) deploying interpolation methods on latent spaces generated by deep learning techniques enables some interpretability for black-box models. We present a detailed case study of our approach for predicting lift-drag ratios from airfoil images. Code developed for this work is available in a public Github repository.

97 MATHEMATICS AND COMPUTING↗

Resolution of the vibrational energy distribution function using a direct simulation Monte Carlo-master equation approach

The direct simulation Monte Carlo (DSMC) method is the primary numerical technique for analysis of rarefied gas flows. While recent progress in computational chemistry is beginning to provide vibrationally resolved transition and reaction cross sections that can be employed in DSMC calculations, the particle nature of the standard DSMC method makes it difficult to use this information in a statistically significant way. The current study introduces a new technique that makes it possible to resolve all of the vibrational energy levels by using a master equation approach along with temperature-dependent transition rates. The new method is compared to the standard DSMC technique for several heat bath and shock wave conditions and demonstrates the ability to resolve the full vibrational manifold at the expected overall rates of relaxation. The ability of the new master equation approach to the DSMC method for resolving, in particular, the high-energy states addresses a well-known, longstanding deficiency of the standard DSMC method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficacy and Safety of Augmenting the Preclose Technique with a Collagen-Based Closure Device for Percutaneous Endovascular Aneurysm Repair

PurposeTo report our experience of selectively augmenting the preclose technique for percutaneous endovascular aneurysm repair (p-EVAR) with an Angio-Seal device as a haemostatic adjunct in cases of significant bleeding after tensioning the sutures of the suture-mediated closure devices.Materials and MethodsProspectively collected data for p-EVAR patients at our institute were analysed. Outcomes included technical success and access site complications. A logistic regression model was used to analyse the effects of sheath size, CFA features and stent graft type on primary failure of the preclose technique necessitating augmentation and also on the development of complications.Resultsp-EVAR was attempted via 122 CFA access sites with a median sheath size of 18-French (range 12- to 28-French). Primary success of the preclose technique was 75.4 % (92/122). Angio-Seal augmentation was utilised as an adjunct to the preclose technique in 20.5 % (25/122). The overall p-EVAR success rate was 95.1 % (116/122). There was a statistically significant relationship (p = 0.0093) between depth of CFA and primary failure of preclose technique. CFA diameter, calcification, type of stent graft and sheath size did not have significant effects on primary preclose technique failure. Overall 4.9 % (6/122) required surgical conversion but otherwise there were no major complications.ConclusionAugmentation with an Angio-Seal device is a safe and effective adjunct to increase the success rate of the preclose technique in p-EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗