Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Quantum-cascade-laser-absorption-spectroscopy diagnostic for temperature, pressure, and NO X 2 Π 1/2 at 500 kHz in shock-heated air at elevated pressures

The design, validation, and application of a quantum-cascade-laser-absorption-spectroscopy diagnostic for measuring gas temperature, pressure, and nitric oxide (NO) in high-temperature air are presented. A distributed-feedback quantum-cascade laser (QCL) centered near 1976 c m − <#comment/> 1 was used to scan across two transitions of NO in its ground electronic state ( X 2 Π <#comment/> 1 / 2 ). A measurement rate of 500 kHz was achieved using a single QCL by: (1) performing current modulation through a bias-tee, and (2) targeting closely spaced transitions with a large difference in lower-state energy. The diagnostic was validated in a mixture of 95% argon and 5% NO, which was shock-heated to ≈ <#comment/> 2000 to 3700 K. The average mean percent differences between laser-absorption-spectroscopy (LAS) measurements and predictions from shock-jump relations for temperature, pressure, and NO mole fraction were 3.1%, 4.1%, and 6.5%, respectively. The diagnostic was then applied to characterize shock-heated air at high temperatures (up to ≈ <#comment/> 5500 K ) and high pressures (up to 12 atm) behind either incident or reflected shocks. The LAS measurements were compared to theoretical predictions from shock-jump relations, pressure sensors mounted in the wall of the shock tube, and equilibrium values of the NO mole fraction. The average mean percent differences between LAS measurements and their aforementioned reference values were 3.2%, 10.8%, and 10.4% for temperature, pressure, and NO mole fraction, respectively. Last, a comparison between a measured NO mole fraction time history and a time-stepped homogeneous reactor simulation performed using two different chemical kinetics mechanisms is presented.

Gilvey, Jonathan J. (ORCID:0000000317664383)↗

Near-MHz temperature and H 2 O measurements in post-detonation fireballs of 25 g hemispherical explosives using scanned-wavelength-modulation spectroscopy

A laser absorption spectroscopy diagnostic integrated within a hardened optical probe was used to measure temperature and water mole fraction at 500 kHz in post-detonation fireballs of explosives. In the experiments, an exploding-bridgewire detonator initiated a 25 g hemisphere of explosive (N5 or PETN). This produced a hemispherical fireball that traveled radially towards a hardened measurement probe. The probe contained a pressure transducer and optical equipment to pitch fiber-coupled laser light across a 12.6 cm gap onto a detector. Tunable diode lasers emitting near 7185.6 and 6806 c m − <#comment/> 1 were used to measure the absorbance spectrum of H 2 O utilizing peak-picking scanned-wavelength-modulation spectroscopy with a scan frequency of 500 kHz and modulation frequencies of 35 and 45.5 MHz, respectively. This enabled measurements of temperature and X H 2 O in the shock-heated air and trailing fireball at 500 kHz. Time histories of pressure, temperature, and H 2 O mole fraction were acquired at different standoff distances to quantify how the fireball evolved in space and time as well as to compare measured quantities between PETN and N5 fireballs. The standard deviation of temperature and X H 2 O during one representative test were found to be 17 K (1.3%) and 0.011 (5%), respectively. These measurements demonstrate this diagnostic’s ability to provide rapid and reliable measurements in harsh, highly transient post-detonation environments produced by solid explosives.

Schwartz, Charles J.↗

H 2 O absorption spectroscopy via focused laser differential interferometry

A modification of focused laser differential interferometry (FLDI) is demonstrated with an infrared tunable diode laser (TDL) to achieve simultaneous absorption spectroscopy (AS) measurements. Measurements from this absorbing-FLDI (A-FLDI) are shown for a Hencken burner plume. Initial comparison measurements are recorded using TDLAS and an electrical hygrometer. Raw voltage and estimated absorbance measurements illustrate that the technique detects five distinct absorbance peaks of the methane–air flame while retaining the expected behavior of typical FLDI. This modification furthers efforts to enable FLDI to conduct analysis of the pressures, temperatures, and molecular densities of flows. It also explores the potential for reducing path-integration (PI) effects in absorption spectroscopy and potentially enabling spatially and temporally resolved local flow measurements. Reductions in PI length as high as 82%–84% are observed.

Holladay, Seth (ORCID:0009000650875421)↗

Filament-induced breakdown spectroscopy with structured beams

Filament-induced ablation represents an attractive scheme for long-range material identification via optical spectroscopy. However, the delivery of laser energy to the target can be severely hindered by the stochastic nature of multiple-filamentation, ionization of ambient gas, and atmospheric turbulence. In order to mitigate some of these adverse effects, we examine the utility of beam shaping for femtosecond filament-induced breakdown spectroscopy with Gaussian and structured (Laguerre-Gaussian, Airy, and Bessel-Gaussian) beams in the nonlinear regime. Interaction of filaments with copper, zinc, and brass targets was studied by recording axially-resolved broadband emission from the filament-induced plasma. The laser-solid coupling efficacy was assessed by inferring thermodynamic parameters such as excitation temperature and electron density. While under our experimental conditions the ablation rate with Gaussian- and Laguerre-Gaussian beams is found to be similar, the Airy and Bessel-Gaussian beams offer the advantage of longitudinally extended working zones. These results provide insights into potential benefits of structuring ultrafast laser beams for standoff sensing applications.

47 OTHER INSTRUMENTATION↗

Frequency-domain terahertz spectroscopy using long-carrier-lifetime photoconductive antennas

We present a telecommunication-compatible frequency-domain terahertz spectroscopy system realized by novel photoconductive antennas without using short-carrier-lifetime photoconductors. Built on a high-mobility InGaAs photoactive layer, these photoconductive antennas are designed with plasmonics-enhanced contact electrodes to achieve highly confined optical generation near the metal/semiconductor surface, which offers ultrafast photocarrier transport and, hence, efficient continuous-wave terahertz operation including both generation and detection. Consequently, using two plasmonic photoconductive antennas as a terahertz source and a terahertz detector, we successfully demonstrate frequency-domain spectroscopy with a dynamic range more than 95 dB and an operation bandwidth of 2.5 THz. Moreover, this novel approach to terahertz antenna design opens up a wide range of new possibilities for many different semiconductors and optical excitation wavelengths to be utilized, therefore bypassing short-carrier-lifetime photoconductors with limited availability.

36 MATERIALS SCIENCE↗

Implementing an electronic sideband offset lock for isotope shift spectroscopy in radium

We demonstrate laser frequency stabilization with at least 6 GHz of offset tunability using an in-phase/quadrature (IQ) modulator to generate electronic sidebands (ESB) on a titanium sapphire laser at 714 nm and we apply this technique to perform isotope shift spectroscopy of 226 Ra and 225 Ra. By locking the laser to a single resonance of a high finesse optical cavity and adjusting the lock offset, we determine the frequency difference between the magneto-optical trap (MOT) transitions in the two isotopes to be 2630.0 ± 0.3 MHz, a factor of 29 more precise than the previously available data. Using the known value of the hyperfine splitting of the 3 P 1 level, we calculate the isotope shift for the 1 S 0 to 3 P 1 transition to be 2267.0 ± 2.2 MHz, a factor of 8 more precise than the best available value. Our technique could be applied to countless other atomic systems to provide unprecedented precision in isotope shift spectroscopy and other relative frequency comparisons.

47 OTHER INSTRUMENTATION↗

Broadband rapid-scanning phase-modulated Fourier transform electronic spectroscopy

We present a phase-modulated approach for ultrabroadband Fourier transform electronic spectroscopy. To overcome the bandwidth limitations and spatial chirp introduced by acousto-optic modulators (AOMs), pulses from a 1 µm laser are modulated using AOMs prior to continuum generation. This phase modulation is transferred to the continuum generated in a yttrium aluminum garnet crystal. Separately generated phase-modulated continua in two arms of a Mach-Zehnder interferometer interfere with the difference of their modulation frequencies, enabling physical under-sampling of the signal and the suppression of low-frequency noise. By interferometrically tracking the relative time delay of the continua, we perform continuous, rapid-scanning Fourier transform electronic spectroscopy with a high signal-to-noise ratio and spectral resolution. As proof of principle, we measure the linear absorption and fluorescence excitation spectra of a laser dye and various biological samples.

Javed, Ariba↗

Polarization-separated double-imaging spectroscopy for weakly-ionized plasma diagnostics

Laser Thomson scattering, which provides thermal properties of electrons, has been extensively utilized in plasma diagnostics. However, being a non-resonant linear light scattering technique, it often encounters several challenges in weakly-ionized plasma diagnostics due to spectral overlap with different scatterings induced from other existing species, including Mie, Rayleigh, and rotational Raman scatterings. To address this challenge, we propose an imaging spectroscopy technique, polarization-separated double-imaging spectroscopy (PoDIS), which selectively separates specific scatterings based on their polarization characteristics. Using an atmospheric plasma jet as a plasma source for demonstration, we show that PoDIS can effectively separate rotational Raman and Thomson scatterings from a superimposed spectrum without prior knowledge or assumptions about the thermal properties of neutrals or electrons. This separation enables independent fitting of the rotational Raman and Thomson scattering spectra, allowing for precise determination of the thermal properties of neutral particles and electrons separately.

Bak, Junhwi [Texas A&M University, College Station↗

Stochastic equilibrium Raman spectroscopy (STERS)

In this manuscript, we propose a new method for cavity- and surface-enhanced Raman spectroscopy (SERS) with improved temporal resolution in the measurement of stochastic Raman spectral fluctuations. Our approach combines Fourier spectroscopy and photon correlation to decouple the integration time from the temporal resolution. Using statistical optics Monte Carlo simulations, we establish the relationship between time resolution and Raman signal strength, revealing that typical Raman spectral fluctuations, commensurate with molecular conformational dynamics, can theoretically be resolved on micro- to millisecond timescales. The method can further extract average single-molecule dynamics from small sub-ensembles, thereby potentially mitigating challenges in achieving strictly single-molecule isolation on SERS substrates.

Cobb-Bruno, Colburn [University of California, Ber↗

Low blaze angle grating for fully dispersive x-ray spectroscopy

We demonstrate fabrication of an ultra-low blaze angle (LBA) grating designed for time-resolved spectroscopy in the x-ray region. A blaze angle of 0.12° was achieved by the groove depth reduction process providing a perfect saw-tooth shape of the grooves. The 200 lines/mm LBA grating exhibited high diffraction efficiency at a photon energy of 8 KeV. Use in a spectrometer would open up dispersive x-ray absorption spectroscopy across a wide energy range including the K edges of 3d transition metals, with much greater efficiency than traditional crystal spectrometers.

Voronov, D. L.↗

Two-dimensional phase cartography for high-harmonic spectroscopy

Extremely nonlinear spectroscopy based on high-order-harmonic generation has become a powerful investigation method for attosecond dynamics in gas and solid targets. In particular, the phase of harmonic emission was shown to carry profound insight into atomic and molecular structure and dynamics. However, current techniques offer phase measurements only along specific directions, thus providing partial characterization. Here we report on a new approach combining optical and quantum interferometers measuring along two dimensions the intensity and phase of harmonic emission from aligned molecules in the exact same experimental conditions. This two-dimensional cartography technique measures the phase with no arbitrary offset and no uncertainty on its sign. Measurements along different dimensions can be combined in two ways: either a single mapping or a redundant mapping allowing high-precision phase recovery using a Shack–Hartmann-like algorithm. We demonstrate both methods in a nitrogen test case, which allows disentangling structural and dynamical effects. Two-dimensional phase cartography paves the way to high-resolution high-harmonic spectroscopy for applications such as quantum orbital tomography and attosecond charge migration in molecules.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dual-comb spectroscopy in the deep ultraviolet

This Letter reports dual-frequency-comb spectroscopy in the deep ultraviolet used to characterize transient laser-produced plasmas. Dual-comb spectroscopy at these wavelengths enables access to a large number of strong electronic transitions in neutral and ionized atoms and molecules. This broadband dual-frequency-comb system at 265 nm measures multiple transitions in neutral and singly ionized iron atoms in a laser-produced plasma. Analysis of absorption spectra yields time-resolved ion and neutral column densities, excitation temperatures, and electron densities, which are measured down to 10 14 cm —3 levels. The results provide insights into low-temperature plasma properties.

47 OTHER INSTRUMENTATION↗

Redefining precision interferometry and spectroscopy with high-performance optical interference coatings

High-performance optical interference coatings have transformed precision interferometry and spectroscopy by enabling unparalleled control over light–matter interactions. This review explores recent innovations in ion-beam sputtered amorphous dielectric, as well as substrate-transferred crystalline coatings, and their impact on systems at the forefront of precision metrology. These state-of-the-art coating techniques generate multilayers with ultralow optical losses, yielding mirrors with exceptional reflectivity. Refinements in their noise performance push the ultimate limits of sensitivity, resolution, and stability in demanding laser-based metrology applications. These technologies underpin the most advanced timekeeping and spatial measurement tools, enabling high-finesse reference cavities for the world’s most precise optical atomic clocks and low-noise reflective test masses for km-baseline gravitational-wave detectors. Emerging hybrid designs combining these techniques expand access to the mid-infrared spectral region, enabling the first ultralow-optical-loss coatings in the 3000–5000 nm wavelength range for enhanced spectroscopy and trace-gas detection. We highlight how these technologies redefine coating performance metrics and set new benchmarks in quantum science, fundamental physics, and precision optical sensing.

Cole, Garrett D. [University of Arizona, Tucson, A↗

The importance of electron scattering in the analysis of actinide X-ray spectroscopy

Abstract Manifestations of electron scattering in X-ray spectroscopy have been evident for decades. Here, it will be shown that the proper interpretation of variants of X-ray Absorption Spectroscopy (XAS) of actinide materials must include an accurate treatment of features caused by electron scattering, i.e., EXAFS or Extended X-ray Absorption Fine Structure. These EXAFS features can be of such low energy that they are within ten to twenty electron volts of the Unoccupied Density of States (UDOS), immediately above the Fermi Energy or Band Gap. The adaption of simple models using the FEFF simulation program will be presented, including the demonstration of the robust nature of the results from different models. Graphical abstract

Tobin, J. G. (ORCID:0000000322943301)↗

Nuclear Spectroscopy for the Exploration of Mars and Beyond

Nuclear spectroscopy will continue to play a critical role in planetary exploration in the next decade, including searching for habitable environments and biosignatures, identifying ideal targets for in-situ resource utilization, and continuing its track record in understanding planetary evolution. Nuclear spectroscopy is the only technique that provides bulk geochemical abundance at depth, at a range of spatial scales depending on platform.

79 ASTRONOMY AND ASTROPHYSICS↗

Connecting Activation Calculations with Gamma Spectroscopy

For many years Lawrence Livermore National Laboratory (LLNL) has used gamma spectroscopy to determine quantities of radioactive nuclides created by irradiation of stable species with neutrons and light charged particles. LLNL has also maintained activation codes and nuclear cross sections for the purpose of modeling activations under the experimental conditions, and the cross section sets used in those calculations typically include nuclear isomers. Connecting the measurements to activation calculations that include isomers is a non-trivial matter because an activation calculation must be followed by a procedure for bookkeeping of calculated isomer populations after the irradiation to simulate what radiochemists would infer about isotope populations from gamma spectroscopy performed days or weeks after the irradiation. Traditionally we have used the method of “isomer sums” for this bookkeeping. This report explains our formulation of isomer sums and application to specific cross section sets for different nuclides that were detected.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Investigating the Curing Process of Epoxy Thermosets by Near-Infrared (nIR) Spectroscopy

Near-Infrared (nIR) Spectroscopy is a type of absorption spectroscopy that may be used to study the curing process of thermosetting epoxy-based resins like Eccostock FFP. This is accomplished by monitoring the absorption bands of the epoxy oxirane ring, which decrease in intensity with increasing degree of cure. Relative to epoxy absorption bands in the mid-IR region, those in the nIR range exhibit less overlap, allowing for a more accurate analysis of cure kinetics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The transient properties of 2D magnets: from mechanical exfoliation to ultrafast optical spectroscopy of CrX 3 materials

The discovery of two-dimensional (2D) systems hosting intrinsic long-range magnetic order represents a seminal achievement, adding to the already diverse array of physics supported by layered van der Waals (vdW) materials. This finding has spurred great interest among the research community, with efforts aimed at uncovering their fundamental properties and light- matter interactions. A prototypical example of a 2D magnetic material is Crl 3 , where the strong relationship between crystalline structure and magnetic order, along with strong light- matter interactions, provide a promising platform to explore the nature of couplings between magnetism and the other degrees of freedom at the 2D limit. In this report, we highlight our efforts involving the use of time-resolved magneto-optical Kerr effect (TR-MOKE) spectroscopy to probe the magnetization and vibrational dynamics of Crl 3 . These measurements reveal evidence of strong exchange-mediated coupling between lattice vibrations and spin oscillations. Additionally, we discuss our related efforts to explore other material from the Chromium trihalide family through mechanical exfoliation to support subsequent optical spectroscopy investigations.

36 MATERIALS SCIENCE↗