Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Imaging MS Methodology for More Chemical Information in Less Data Acquisition Time Utilizing a Hybrid Linear Ion Trap-Orbitrap Mass Spectrometer

A novel mass spectrometric imaging method is developed to reduce the data acquisition time and provide rich chemical information using a hybrid linear ion trap-orbitrap mass spectrometer. In this method, the linear ion trap and orbitrap are used in tandem to reduce the acquisition time by incorporating multiple linear ion trap scans during an orbitrap scan utilizing a spiral raster step plate movement. The data acquisition time was decreased by 43-49% in the current experiment compared to that of orbitrap-only scans; however, 75% or more time could be saved for higher mass resolution and with a higher repetition rate laser. Using this approach, a high spatial resolution of 10 {micro}m was maintained at ion trap imaging, while orbitrap spectra were acquired at a lower spatial resolution, 20-40 {micro}m, all with far less data acquisition time. Furthermore, various MS imaging methods were developed by interspersing MS/MS and MSn ion trap scans during orbitrap scans to provide more analytical information on the sample. This method was applied to differentiate and localize structural isomers of several flavonol glycosides from an Arabidopsis flower petal in which MS/MS, MSn, ion trap, and orbitrap images were all acquired in a single data acquisition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pulsed Multiple Reaction Monitoring Approach to Enhancing Sensitivity of a Tandem Quadrupole Mass Spectrometer

Liquid chromatography (LC)-triple quadrupole mass spectrometers operating in a Multiple Reaction Monitoring (MRM) mode are increasingly used for quantitative analysis of low abundance analytes in highly complex biochemical matrices. After development and selection of optimum MRM transition, sensitivity and data quality limitations are largely related to mass spectral peak interferences from sample or matrix constituents and statistical limitations at low number of ions reaching the detector. Herein, we report a new approach to enhancing MRM sensitivity by converting the continuous stream of ions from the ion source into a pulsed ion beam through the use of an Ion Funnel Trap (IFT). Evaluation of the pulsed MRM approach was performed with a tryptic digest of Shewanella oneidensis strain MR-1 spiked with several reference peptides. The sensitivity improvement observed with the IFT coupled to the triple quadrupole instrument is based on several unique features. First, ion accumulation in the radio frequency (RF) ion trap facilitates improved droplet desolvation, which is manifested in the reduced background ion noise at the detector. Second, signal amplitude for a given transition is enhanced because of an order-of-magnitude increase in the ion charge density per unit time compared to a continuous mode of operation. Third, signal detection at the full duty cycle is obtained, as the trap use eliminates dead times between transitions, which are inevitable with continuous ion streams. In comparison with the conventional approach, the pulsed MRM signals showed up to 5-fold enhanced peak amplitude and 2-3 fold reduced chemical background, resulting in an improvement in the limit of detection (LOD) by a factor of ~ 4 to ~ 8.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Novel Application of Machine Learning Techniques for Rapid Source Apportionment of Aerosol Mass Spectrometer Datasets

In this work, we apply machine learning approaches sparse multinomial logistic regression to classify aerosol mass spectrometer (AMS) unit mass resolution (UMR) data followed by an ensemble regression technique for source apportionment of organic aerosols (OA). The classifier was trained on 60 well characterized laboratory and positive matrix factorization (PMF) deconvolved reference spectra to identify eight OA types. These include four laboratory-derived secondary organic aerosol (SOA) spectra, which include isoprene photooxidation SOA, isoprene epoxydiols (IEPOX) SOA, a monoterpene SOA type that includes a-pinene and ß-pinene SOA, and aromatic SOA from oxidation of naphthalene and m-xylene precursors, as well as PMF deconvolved spectra for three primary organic aerosol (POA) types, namely, hydrocarbon-like organic aerosol (HOA), biomass burning organic aerosol (BBOA), and cooking OA (COA), and a more oxidized oxygenated OA type (MO-OOA). A 5-fold cross-validation strategy, repeated 10 times, was used to assess the classifier’s performance. The classifier had high classification accuracy for COA, aromatic SOA, and isoprene SOA spectra but incorrectly classified ~9% by number of MO-OOA spectra as BBOA, 12% of BBOA spectra as HOA (and vice versa), and 18% of IEPOX-SOA spectra as aromatic SOA. Next, an ensemble regression model was trained on an artificially generated dataset consisting of mixtures of different OA types to assess its ability to predict fractional mass abundances from classification probabilities of various OA species obtained from the multinomial logistic regression classifier trained on the reference spectra. Ultimately, the proposed approach was applied for source apportionment of aircraft-based AMS measurements of OA UMR spectra during the HI-SCALE field campaign. On two representative days (May 6th and 18th, 2016), the algorithm determined that ~50-60% of OA by mass was MO-OOA, which represented a highly aged organic aerosol mixture from different sources. On both days, BBOA was determined to contribute less than 10% to OA by mass. However, on May 18th, the aromatic SOA fraction was higher compared to that on May 6th. The proposed approach is capable of rapidly analyzing AMS data in real time, making it suitable for applications where rapid source apportionment of AMS OA spectra is desirable.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fast In Situ Airborne Measurement of Ammonia Using a Mid-Infrared Off-Axis ICOS Spectrometer

A new ammonia (NH 3 ) analyzer was developed based on off-axis integrated cavity output spectroscopy. Its feasibility was demonstrated by making tropospheric measurements in flights aboard the Department of Energy Gulfstream-1 aircraft. The ammonia analyzer consists of an optical cell, quantum-cascade laser, gas sampling system, control and data acquisition electronics, and analysis software. The NH 3 mixing ratio is determined from high-resolution absorption spectra obtained by tuning the laser wavelength over the NH 3 fundamental vibration band near 9.67 μm. Excellent linearity is obtained over a wide dynamic range (0–101 ppb v ) with a response rate (1/e) of 2 Hz and a precision of ±90 ppt v (1σ in 1 s). Two research flights were conducted over the Yakima Valley in Washington State. In the first flight, the ammonia analyzer was used to identify signatures of livestock from local dairy farms with high vertical and spatial resolution under low wind and calm atmospheric conditions. In the second flight, the analyzer captured livestock emission signals under windy conditions. Finally, our results demonstrate that this new ammonia spectrometer is capable of providing fast, precise, and accurate in situ observations of ammonia aboard airborne platforms to advance our understanding of atmospheric compositions and aerosol formation.

airborne↗

Multichannel Doppler transmission grating spectrometer at the Alcator C-Mod tokamak

Upgrades to an existing transmission grating spectrometer for visible light used for Doppler velocity and temperature measurements at the Alcator C-Mod tokamak are given. These include a new Princeton Instruments Photonmax 512B charge-coupled device and a four channel fiber optic input. These together allow improvements to the signal level, time resolution, and the number of spatial channels. The fiber optic input allows four simultaneous spatial channels each of which offers a larger percentage of input light flux when compared to the standard fiber slit combination. The ''on chip'' amplification combined with versatile pixel binning further increases the signal to noise ratio allowing a continuous acquisition of spectra every 8 ms. The error bars for extracted velocity and temperature values are potentially smaller owing to the smaller pixel size and increased light flux which allow a more detailed line shape and simplifies line fitting. Examples of time and space resolved spectra are shown and further improvements are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopic evaluation of three different gratings used for a flat-field extreme ultraviolet spectrometer to monitor {delta}n=1 transitions from medium-Z impurities in 10-30 A

Spectral characteristics of varied line spacing 2400 grooves/mm gratings used for a flat-field extreme ultraviolet spectrometer have been evaluated to monitor {delta}n=1 (n=2-3) transitions from medium-Z impurities in 10-30 A, where many spectral lines from metallic impurities closely exist. For this purpose emission spectra of the {delta}n=1 transitions from partially L-shell-ionized Ti and Fe have been measured in large helical device. At first, a ruled and a holographic grating were utilized for the comparative study. Both gratings suppressed higher order light effectively but spectral sensitivity was much higher for the holographic grating. The ruled grating, however, attained better spectral resolution (0.083 A at 18.97 A) in the 10-100 A range compared to that (0.130 A) of the holographic grating. After that a recently developed new holographic grating with different laminar shapes and line spacings has attempted to improve the spectral resolution. As a result, it has considerably improved the spectral resolution in the 10-30 A range, i.e., {approx}0.090 A. However, it is found that the experimentally obtained spectral resolution is quit poor compared to the computationally simulated one, suggesting a technical difficulty in manufacturing exactly the varied line spacing of the holographic grating at such a short wavelength range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Suprathermal electron studies in the TCV tokamak: Design of a tomographic hard-x-ray spectrometer

Electron cyclotron resonance heating and electron cyclotron current drive, disruptive events, and sawtooth activity are all known to produce suprathermal electrons in fusion devices, motivating increasingly detailed studies of the generation and dynamics of this suprathermal population. Measurements have been performed in the past years in the tokamak a configuration variable (TCV) tokamak using a single pinhole hard-x-ray (HXR) camera and electron-cyclotron-emission radiometers, leading, in particular, to the identification of the crucial role of spatial transport in the physics of ECCD. The observation of a poloidal asymmetry in the emitted suprathermal bremsstrahlung radiation motivates the design of a proposed new tomographic HXR spectrometer reported in this paper. The design, which is based on a compact modified Soller collimator concept, is being aided by simulations of tomographic reconstruction. Quantitative criteria have been developed to optimize the design for the greatly variable shapes and positions of TCV plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutron spectrometer for ITER using silicon detectors

High resolution neutron spectrometers provide information about plasma parameters at existing fusion experiments. Such a system may also be employed at ITER. Proton recoil telescopes have classically been used to detect neutrons with good energy resolution but poor efficiency. Using annular silicon detectors, it is possible to greatly increase the solid angle coverage and hence improve efficiency. Based on a simulation (MCNPX) study, the scaling of energy resolution, efficiency, and time to determine an ion temperature to 10% accuracy on foil thickness and detector location is shown. The latter quantity is used to determine the optimum foil thickness and detector geometry for specific plasma temperatures. For a 20 keV deuterium-tritium (DT) plasma, 5.3% resolution with efficiency of 2.9x10{sup -4} n cm{sup 2} is attainable using the available detectors. This gives a temperature measurement with 10% accuracy in 1.1 ms for a neutron flux of 2x10{sup 9} n cm{sup -2}. Multiple detectors can be used to further increase the efficiency if needed. A system of this kind could be tested in a future DT campaign at, for example, JET.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A spatially resolving x-ray crystal spectrometer for measurement of ion-temperature and rotation-velocity profiles on the Alcator C-Mod tokamak

A new spatially resolving x-ray crystal spectrometer capable of measuring continuous spatial profiles of high resolution spectra ({lambda}/d{lambda}>6000) of He-like and H-like Ar K{alpha} lines with good spatial ({approx}1 cm) and temporal ({approx}10 ms) resolutions has been installed on the Alcator C-Mod tokamak. Two spherically bent crystals image the spectra onto four two-dimensional Pilatus II pixel detectors. Tomographic inversion enables inference of local line emissivity, ion temperature (T{sub i}), and toroidal plasma rotation velocity (v{sub {phi}}) from the line Doppler widths and shifts. The data analysis techniques, T{sub i} and v{sub {phi}} profiles, analysis of fusion-neutron background, and predictions of performance on other tokamaks, including ITER, will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral resolution measurement of an x-ray imaging crystal spectrometer for KSTAR

A spectral resolution measurement of the x-ray imaging crystal spectrometer for the Korea Superconducting Tokamak Advanced Research machine utilizing a segmented position-sensitive detector and time-to-digital converter based delay-line readout electronics was performed by using an x-ray tube in a laboratory. The measured spectral resolution is about 12 600, which means the actual energy resolution is 0.32 eV for the x-ray tube's bremsstrahlung peak energy of 4 keV. The results from the spectral resolution measurement are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Results from The MAGNEX Large Acceptance Spectrometer

The MAGNEX large-acceptance spectrometer was commissioned with beams from the LNS Tandem. First results of physical interest are presented. The obtained 10{sup -3} energy resolution confirms the ambitious characteristic of the calculations and allows considering the instrument as an ideal tool for future studies in the field of nuclear spectroscopy and reaction mechanisms at incident energies not far form the Coulomb barrier.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Realistic simulations of the AGATA Demonstrator+PRISMA Spectrometer

The performance of the AGATA Demonstrator Array coupled to the PRISMA magnetic spectrometer have been evaluated in a consistent way using detailed Monte Carlo simulations of the two devices. Results for the {sup 90}Zr+{sup 208}Pb at 560 MeV reaction are presented and discussed here, proving that the Doppler correction capabilities of the AGATA+PRISMA setup will be very close to the intrinsic energy resolution of the germanium detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Collective excitations in {sup 88}Zr studied with the HORUS spectrometer

Using the HORUS spectrometer at the Cologne FN-TANDEM accelerator, we performed a {gamma}{gamma} coincidence measurement on {sup 88}Zr. The reaction used was {sup 89}Y(p,2n){sup 88}Zr. A particular point of interest was the search for a potential 2{sup +} mixed-symmetric state. In the experiment, we measured the multipole mixing ratios of the decays of the 2{sub 2}{sup +} and the 2{sub 3}{sup +} states and determined the energies of the 2{sub 3}{sup +} and 0{sub 2}{sup +} states precisely. Furthermore, we found two new levels and seven new {gamma} transitions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gain stabilization control system of the upgraded magnetic proton recoil neutron spectrometer at JET

Burning plasma experiments such as ITER and DEMO require diagnostics capable of withstanding the harsh environment generated by the intense neutron flux and to maintain stable operating conditions for times longer than present day systems. For these reasons, advanced control and monitoring (CM) systems will be necessary for the reliable operation of diagnostics. This paper describes the CM system of the upgraded magnetic proton recoil neutron spectrometer installed at the Joint European Torus focusing in particular on a technique for the stabilization of the gain of the photomultipliers coupled to the neutron detectors. The results presented here show that this technique provides good results over long time scales. The technique is of general interest for all diagnostics that employ scintillators coupled to photomultiplier tubes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a compact electron ion coincidence analyzer using a coaxially symmetric mirror electron energy analyzer and a miniature polar-angle-resolved time-of-flight ion mass spectrometer with four concentric anodes

A compact electron ion coincidence (EICO) analyzer that uses a coaxially symmetric mirror electron energy analyzer and a miniature polar-angle-resolved time-of-flight ion mass spectrometer with four concentric anodes was developed for surface science and surface analysis. The apparatus is especially useful in the study of ion desorption stimulated by an Auger process because information on the mass, yield, desorption polar angle, and kinetic energy of ions can be obtained for the selected core-ionization-final-states or the selected Auger-final-states. The analyzer can be used also for analysis of the configuration of specific surface molecules because the desorption polar angles reflect the direction of surface bonds. The EICO analyzer was evaluated by measuring polar-angle-resolved-ion yield spectra and coincidence spectra of Auger-electron and polar-angle-resolved H{sup +} from condensed water.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultraviolet photodissociation of C{sub 2}F{sub 5}I with a small and simple photofragment translational spectrometer

Photodissociation dynamics of C{sub 2}F{sub 5}I near 280 and 304 nm has been investigated on a small and simple time-of-flight photofragment translational spectrometer (PTS). On this new PTS, the photolyzed and ionized fragments, not accelerated by electric field, travel freely for a short flight path (<50 mm) and are detected by microchannel plates. In the spectra of the I*({sup 2}P{sub 1/2}) channel at 281.73 and 304.02 nm, vibrational peaks with spacing of {approx}350 cm{sup -1} are partially resolved, indicating the preferential excitation of CF{sub 2} wag mode ({nu}{sub 11}=366 cm{sup -1}) of C{sub 2}F{sub 5} photofragment. The fraction of the available energy disposed into the internal energy is higher than 50% for both I{sup *} channel and I channel, showing the high excitation of vibration in the C{sub 2}F{sub 5} fragments. The fragment recoil anisotropy parameter {beta}(I{sup *}), determined to be 1.70 at 281.73 nm and 1.64 at 304.02 nm, reveals that I* atoms are produced predominantly from the parallel {sup 3}Q{sub 0}<-N transition. The anisotropy parameter {beta}(I), determined to be 1.25 at 279.71 nm and 0.88 at 304.67 nm, implies that I atoms are produced from two excited states, i.e., direct dissociation via the perpendicular {sup 3}Q{sub 1}(leftarrow)N transition, and indirect dissociation via the parallel {sup 3}Q{sub 0}(leftarrow)N transition then curve crossing to the {sup 1}Q{sub 1} potential energy surface. Analysis on the recent studies with vibrational state resolution in the photodissociation of alkyl iodides in the A band reveals that the ''symmetric bending'' mode on {alpha}-carbon of alkyl iodides is the preferential vibrational excitation mode, which can be explained by the classic impulsive model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Broadband, high dynamics and high resolution charge coupled device-based spectrometer in dynamic mode for multi-keV repetitive x-ray sources

We present a new operating mode, using a charged coupled device as dispersionless spectrometer dedicated to repetitive x-ray sources in the multi-keV domain. This enables to get spectra with high statistics in a short acquisition time and a way compatible with the operation of other diagnostics requiring accumulation. Several reconstruction algorithms for the spreading events are discussed, and a near Fano-limited resolution is demonstrated by using single pixel events. In this case, a method to take into account partial canceling of the events is presented. Experimental characterization and detailed modeling of the detector are performed, which allow to determine absolute number of photon with {+-}35% accuracy. Characterization of the 5-25 keV x rays emitted by a short pulse laser-produced plasma is reported, as well as their dependency with the atomic number, the laser duration, and energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗