Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Selection optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Comparison of the efficacy of a biocompatible and a distillable solvent for pretreatment of mixed bioenergy feedstocks

Biomass deconstruction is a crucial step in the production of lignocellulosic biofuels and bioproducts. However, identifying and selecting an optimal pretreatment solvent that enhances enzymatic saccharification while being cost-efficient and ensuring sustainability remains a challenge. In this study, we compare the effectiveness of the biocompatible ionic liquid cholinium lysinate ([Ch][Lys]) against the distillable solvent ethanolamine, when used for the pretreatment of mixed bioenergy feedstocks, including poplar, switchgrass, and sorghum. [Ch][Lys] was used at a concentration of 10 % wt. in a one-pot configuration without biomass washing and ethanolamine was used in a concentrated form and removed with a vacuum oven, before performing enzymatic hydrolysis and microbial conversion. Our results show that ethanolamine pretreatment consistently enhances the glucose yield across various biomass types compared to [Ch][Lys], with improvements ranging from 22.0 % to 52.7 %. The highest combined sugar release was observed when the three feedstocks were combined in equal amounts and pretreated with ethanolamine, achieving a glucose yield of 84.6 % and a xylose yield of 76.6 %. Additionally, ethanolamine exhibited exceptional solvent recovery efficiency, with removal efficiencies exceeding 99.8 % at 120 °C across all feedstocks, highlighting its advantage over non-distillable solvents. While both solvents produced biocompatible hydrolysates, the hydrolysates prepared using ethanolamine resulted in higher bioproduct formation. These findings highlight the industrial relevance of selecting recyclable and biocompatible solvents for scalable, sustainable, and cost-effective bioenergy production. This study contributes to the development of economically viable and scalable pretreatment technologies for bioenergy applications using different feedstocks and process configurations.

Rahman, Maksudur↗

Quantitative Evaluation of Top Coal Caving Methods at the Working Face of Extra‐Thick Coal Seams Based on the Random Medium Theory

Adopting an effective top coal caving method is the key to enhancing coal recovery and reducing gangue content for the fully mechanized top coal caving working face with extra‐thick coal seams. In this study, the movement of coal particles generated during top coal caving is considered to follow a normal distribution. Then, the caving body and coal‐rock settlement along the working face during the caving process are studied based on both the random media theory and probability theory. Accordingly, the optimal caving interval and caving sequences are determined, and a novel interval symmetrical coal caving method is proposed. The proposed method is systematically verified with results from physical similarity tests, and different caving methods are assessed by field tests. The results show the following: (1) The coal‐rock settlement and the caving body demonstrate clear axial symmetrical features along the working face; the size of the caving body increases as the caving height grows and its shape turns progressively from semicircular to semielliptical with a lower foot of the coal‐rock settlement. (2) The caving interval is derived using the sum of the radii of the coal‐rock settlement curves formed by the two largest caving bodies. (3) The symmetrical caving approach provides a symmetrical space for the subsequent movement of the broken top coal, which enables a uniform development of the caving body. (4) Compared with the traditional sequential coal caving method with the same number of supports, the interval symmetrical caving method results in a 21.7% of coal production increase, 17% caving rate promotion, and a shortened caving time by 23.4%. (5) The interval symmetrical caving method is found to improve the controllability of the caving process at the fully mechanized top coal caving working face. In general, this work presents a theoretical approach to select the optimal caving methods for the fully mechanized caving working face in extra‐thick coal seams for an improved production efficiency of the work face. The results of this study can also provide theoretical significance and referencing value for quantitative analyses of the coal caving methods for work faces with similar geological conditions.

Jiulin, Shi (ORCID:0000000155819062)↗

High Pressure Water Stripping Using Multi-Orifice Nozzles

The use of multi-orifice rotary nozzles greatly increases the speed and stripping effectiveness of high pressure water blasting systems, but also greatly increases the complexity of selecting and optimizing the operating parameters. The rotational speed of the nozzle must be coupled with its transverse velocity as it passes across the surface of the substrate being stripped. The radial and angular positions of each orifice must be included in the analysis of the nozzle configuration. Orifices at the outer edge of the nozzle head move at a faster rate than the orifices located near the center. The energy transmitted to the surface from the impact force of the water stream from an outer orifice is therefore spread over a larger area than energy from an inner orifice. Utilizing a larger diameter orifice in the outer radial positions increases the total energy transmitted from the outer orifice to compensate for the wider distribution of energy. The total flow rate from the combination of all orifices must be monitored and should be kept below the pump capacity while choosing orifice to insert in each position. The energy distribution from the orifice pattern is further complicated since the rotary path of all the orifices in the nozzle head pass through the center section. All orifices contribute to the stripping in the center of the path while only the outer most orifice contributes to the stripping at the edge of the nozzle. Additional orifices contribute to the stripping from the outer edge toward the center section. With all these parameters to configure and each parameter change affecting the others, a computer model was developed to track and coordinate these parameters. The computer simulation graphically indicates the cumulative affect from each parameter selected. The result from the proper choices in parameters is a well designed, highly efficient stripping system. A poorly chosen set of parameters will cause the nozzle to strip aggressively in some areas while leaving the coating untouched in adjacent sections. The high pressure water stripping system can be set to extremely aggressive conditions allowing stripping of hard to remove adhesives, paint systems, and even cladding and chromate conversion coatings. The energy force can also be reduced to strip coatings from thin aluminum substrates without causing any damage or deterioration to the substrate's surface. High pressure water stripping of aerospace components has thus proven to be an efficient and cost effective method for cleaning and removing coatings.

Hoppe, David↗

High Pressure Water Stripping Using Multi-Orifice Nozzles

The use of multi-orifice rotary nozzles not only increases the speed and stripping effectiveness of high pressure water blasting systems, but also greatly increases the complexity of selecting and optimizing the operating parameters. The rotational speed of the nozzle must be coupled with the transverse velocity of the nozzle as it passes across the surface of the substrate being stripped. The radial and angular positions of each orifice must be included in the analysis of the nozzle configuration. Since orifices at the outer edge of the nozzle head move at a faster rate than the orifice located near the center, the energy impact force of the water stream from the outer orifice is spread over a larger area than the water streams from the inner orifice. Utilizing a larger diameter orifice in the outer radial positions increases the energy impact to compensate for its wider force distribution. The total flow rate from the combination of orifices must be monitored and kept below the pump capacity while choosing an orifice to insert in each position. The energy distribution from the orifice pattern is further complicated since the rotary path of all orifices in the nozzle head pass through the center section, contributing to the stripping in this area while only the outer most orifice contributes to the stripping in the shell area at the extreme outside edge of the nozzle. From t he outer most shell to the center section, more orifices contribute to the stripping in each progressively reduced diameter shell. With all these parameters to configure and each parameter change affecting the others, a computer model was developed to track and coordinate these parameters. The computer simulation responds by graphically indicating the cumulative affect from each parameter selected. The results from the proper choices in parameters is a well designed, highly efficient stripping system. A poorly chosen set of parameters will cause the nozzle to strip aggressively in some areas while leaving the coating untouched in adjacent sections. The high pressure water stripping system can be set to extremely aggressive conditions allowing stripping of hard to remove adhesives, paint systems, cladding and chromate conversion coatings. The energy force can be reduced to strip coatings from thin aluminum substrates without causing damage or deterioration to the substrate's surface. High pressure water stripping of aerospace components have thus proven to be an efficient and cost effective method for cleaning and removing coatings.

Hoppe, David T.↗

Ablation-initiated Isotope-selective Atomic Absorption Spectroscopy of Lanthanide Elements

For remote isotope analysis of low-decontaminated trans-uranium (TRU) fuel, absorption spectroscopy has been applied to a laser-ablated plume of lanthanide elements. To improve isotopic selectivity and detection sensitivity of the ablated species, various experimental conditions were optimized. Isotope-selective absorption spectra were measured by observing the slow component of the plume produced under low-pressure rare-gas ambient. The measured minimum line width of about 0.9 GHz was close to the Doppler width of the Gd atomic transition at room temperature. The relaxation rate of high-lying metastable state was found to be higher than that of the ground state, which suggests that higher analytical sensitivity can be obtained using low-lying state transition. Under helium gas environment, Doppler splitting was caused from particle motion. This effect was considered for optimization for isotope selection and analysis. Some analytical performances of this method were determined under optimum conditions and were discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Identification and in Vivo Evaluation of Liver X Receptor β-Selective Agonists for the Potential Treatment of Alzheimer’s Disease

Herein, we describe the development of a functionally selective liver X receptor β (LXRβ) agonist series optimized for Emax selectivity, solubility, and physical properties to allow efficacy and safety studies in vivo. Compound 9 showed central pharmacodynamic effects in rodent models, evidenced by statistically significant increases in apolipoprotein E (apoE) and ATP-binding cassette transporter levels in the brain, along with a greatly improved peripheral lipid safety profile when compared to those of full dual agonists. These findings were replicated by subchronic dosing studies in non-human primates, where cerebrospinal fluid levels of apoE and amyloid-β peptides were increased concomitantly with an improved peripheral lipid profile relative to that of nonselective compounds. Lastly, these results suggest that optimization of LXR agonists for Emax selectivity may have the potential to circumvent the adverse lipid-related effects of hepatic LXR activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Site Selection for Mars Exopaleontology in 2001

The microbial fossil record encompasses a wide range of information, including cellular remains, stromatolites, biofabrics, trace fossils, biominerals and chemofossils. The preservation of fossils is strongly influenced by the physical, chemical and biological factors of the environment which, acting together, ultimately determine the types of information that will be captured and retained in the rock record. The critical factor in assessing the suitability of a site for a microbial fossil record is the paleoenvironment. The reconstruction of ancient sedimentary environments usually requires the integration of a wide variety of geological information, including the shape, geometry and internal structure of sedimentary deposits, their mineralogy, and geochemistry. For Mars, much of our knowledge about past environments is based on orbital imaging of geomorphic features. This evidence provides an important context and starting point for site selection. However, our knowledge of the martian surface is quite limited, and a major goal of the upcoming exploration effort is to reconstruct the history of Martian volatiles, climate, and hydrology as a context for the exploration for past or present life. Mineralogical mapping from orbit will be an important key in this effort. In exploring for evidence of past life, terrestrial experience suggests that the long-term preservation of biological information as fossils occurs under a fairly narrow range of geological conditions that are well known to paleontologists (1). In detrital sedimentary systems, microbial fossilization is favored by rapid burial in fine-grained, clay-rich sediments. In chemical sedimentary systems, preservation is enhanced by rapid entombment in fine-grained chemical precipitates. For long term preservation, host rocks must be composed of stable minerals that resist chemical weathering, and which form an impermeable matrix and closed chemical system that can protect biosignatures from alteration during subsequent diagenetic change or metamorphism. In this context, host rocks composed of highly ordered, chemically-stable mineral phases, like silica (forming cherts) or phosphate (forming phosphorites), are especially favored. Such lithologies tend to have very long crustal residence times and (along with carbonates and shales), are the most common host rocks for the Precambrian microfossil record on Earth. If we assume that a subsurface hydrosphere has been present throughout martian history, then life could have originated there at any time, perhaps emerging at the surface periodically when climate changes, induced by external forcing or endogenous processes (e.g. volcanism), allowed liquid water to exist at the surface. The recent discovery of subsurface chemolithoautotrophic organisms which are capable of synthesizing organic substrates from C02 and H2 liberated from the aqueous weathering of basalt, is especially. relevant as a model for martian life. While a subsurface habitable zone may yet exist on Mars, access to such environments will likely require drilling to depths of several kilometers. Given the technological challenge of deep drilling, this is unlikely to occur prior to human missions. So, even if there is extant life on Mars today in subsurface habitats, it may be much easier to find its fossil counterparts in ancient deposits exposed at the surface. In exploring for a fossil record in subsurface environments on Mars there are several geological situations that may provide access to the appropriate materials. These include 1) ejecta from impact craters, 2) talus slopes, debris flows or alluvial fans developed below the walls of deep canyons, and 3) the deposits of outflood channels. Examples of aqueous mineral deposits of formed in subsurface environments that could harbor a microbial fossil record include such things as cements in detrital sedimentary rocks, low temperature diagenetic minerals deposited in veins, or filling vesicles in volcanic rocks, and hydrothermal deposits formed below the upper temperature limit for life (about 160 degrees C). There are many sites within the present latitudinal constraints for the 2001 mission (15 deg S to 30 deg N) that meet these requirements. But the practical problem with these kinds of deposits is that they tend to be disseminated, making up only a small percentage of a host rock. Even with mineralogical information provided by the Thermal Emission Spectrometer (TES) presently in orbit around Mars, predicting their occurrence ahead of time may be quite difficult. The deposits of surficial aqueous sedimentary systems are likely to provide the largest targets for site selection in 2001. Of these, the deposits of hydrothermal systems (subaerial and subaqueous thermal springs) have been discussed previously. It is likely that hydrothermal systems were widespread on Mars early in its history and a number of common geo-tectonic settings on Mars are likely to have hosted hydrothermal activity. Most of these are represented within the latitudinal constraints presently identified for 2001. However, the deposits of surface spring systems are likely to be difficult to find as well. On Earth, exposure areas for hydrothermal spring mounds are typically a few square kms, less than a single TES pixel. But such deposits may be quite abundant within some volcanic terrains, It is estimated, for example, that between 15-20% of the floor of Yellowstone caldera is covered by thermal spring deposits. In such abundances, subaerial sinters could well be detected by TES. Where exposed, the shallow subsurface portions of these systems may be quite a lot larger (perhaps tens of square kms), although (as noted above) mineralization may be finely disseminated in the basement rock, making remote detection more difficult. Paleolake Basins. There are a large number of potential paleolake basins on Mars (inclusive of impact craters and volcanic calderas) that have been previously identified using Viking images. Most of these lie in the southern highlands beyond the l5 deg S constraint for 2001. However, deposits of paleolakes may offer the largest and most easily identified exopaleontological targets from orbit. Based on a variety of arguments, some workers have suggested that there was once an ancient ocean on the northern plains, and some sites of interest (potential shoreline terraces) fall within the 30 deg N constraint. From a paleontological standpoint the most interesting places of this type are terminal paleolake basins which are likely to have been both saline and alkaline. Models by Schaefer suggest such environments could be widespread on Mars. The conditions in terminal lake basin settings favor widespread chemical sedimentation, an important condition for microbial fossilization. Important lithological targets for a microbial fossil record in terminal lake basins include spring-deposited carbonates, shoreline cements, a wide variety of evaporite minerals and fine-grained detrital sediments including shales, marls, and water-lain volcanic ash deposits. In developing a strategy to explore for ancient hydrothermal deposits on Mars, we can learn from the methods that have been developed by explorationists to explore for economic mineral deposits on Earth. Due to their simple mineralogy, hydrothermal deposits can often be detected using remote sensing methods. Common thermal spring mineral assemblages include silica, carbonate, and various metallic oxides and sulfides. But there are also a number of diagnostic silicate minerals, including clays, formed by the hydrothermal alteration of country rocks. These hydrothermal minerals have characteristic spectral signatures that could be detected from Mars orbit using high resolution infrared remote sensing methods. In playa lake settings, evaporite deposits often form a predictable "bull's eye" pattern with carbonates being deposited in marginal basin areas, and sulfates and halides occurring progressively more basinward. The floors of some impact craters on Mars, such as "White Rock" and Bequeral Crater (see Oxia Palus NE, Site 148), have floor deposits that could be evaporites, inclusive of carbonates. Evaporite minerals possess characteristic spectral signatures in the infrared and could similarly be identified from Mars orbit using high resolution remote sensing methods. Clearly, utilization of TES data will be important for optimizing site selection for Exopaleontology, and every effort should be made to benefit from that data before a final decision is made.

Farmer, Jack↗

Impact of Electrolyte Composition on Bulk Electrolysis of Furfural over Platinum Electrodes

Partial oxidation of furanic biomass derivatives such as furfural is of interest for the sustainable production of chemicals including furoic acid, maleic acid, and 2,5-furandicarboxylic acid (FDCA). The oxidative bulk electrolysis of furfural is here investigated on platinum electrodes in acidic media. The effects of potential, concentration, pH, and supporting anion are studied, and selectivity trends are coupled with attenuated total reflectance surface-enhanced infrared absorption spectroscopy (ATR-SEIRAS) to illuminate adsorbate structures that influence the catalysis. Increasing potential is found to shift selectivity from primarily C 5 products to C 4 products, coincident with oxidation of the Pt surface. Selectivity changes are also observed moving from pH 1 to pH 4, with an increase in C 5 products at higher pH. Furthermore, changing from the weakly adsorbing perchlorate anion to the specifically-adsorbing phosphate anion results in a number of changes that manifest differently depending on potential and pH. Selectivity to furoic acid is found to be highest above the pKa of phosphoric acid due to the strongly adsorbed phosphate ions suppressing flat-lying configurations of furfural that lead to C−C cleavage. These results point toward opportunities to use electrolyte engineering to tune selectivity and optimize surface conditions to disfavor binding of inhibitory products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi‐dimensional lock‐free arrays for multithreaded mode‐directed tabling in Prolog

Summary This work proposes a new design for the supporting data structures used to implement multithreaded tabling in Prolog systems. Tabling is an implementation technique that improves the expressiveness of traditional Prolog systems in dealing with recursion and redundant computations. Mode‐directed tabling is an extension to the tabling technique that supports the definition of alternative criteria for specifying how answers are aggregated, thus being very suitable for problems where the goal is to dynamically calculate optimal or selective answers. In this work, we leverage the intrinsic potential that mode‐directed tabling has to express dynamic programming problems by creating a new design that improves the representation of multi‐dimensional arrays in the context of multithreaded tabling. To do so, we introduce a new mode for indexing arguments in mode‐directed tabled evaluations, named dim , where each dim argument features a uni‐dimensional lock‐free array. Experimental results using well‐known dynamic programming problems on a 32‐core machine show that the new design introduces less overheads and clearly improves the execution time for sequential and multithreaded tabled evaluations.

Areias, Miguel↗

Search for heavy resonances decaying into two Higgs bosons or into a Higgs boson and a W or Z boson in proton-proton collisions at 13 TeV

A search is presented for massive narrow resonances decaying either into two Higgs bosons, or into a Higgs boson and a W or Z boson. The decay channels considered are $ \mathrm{H}\mathrm{H}\to \mathrm{b}\overline{\mathrm{b}}{\tau}^{+}{\tau}^{-} $ and $ \mathrm{V}\mathrm{H}\to \mathrm{q}\overline{\mathrm{q}}{\tau}^{+}{\tau}^{-} $ , where H denotes the Higgs boson, and V denotes the W or Z boson. This analysis is based on a data sample of proton-proton collisions collected at a center-of-mass energy of 13 TeV by the CMS Collaboration, corresponding to an integrated luminosity of 35.9 fb$^{−1}$. For the TeV-scale mass resonances considered, substructure techniques provide ways to differentiate among the hadronization products from vector boson decays to quarks, Higgs boson decays to bottom quarks, and quark- or gluon-induced jets. Reconstruction techniques are used that have been specifically optimized to select events in which the tau lepton pair is highly boosted. The observed data are consistent with standard model expectations and upper limits are set at 95% confidence level on the product of cross section and branching fraction for resonance masses between 0.9 and 4.0 TeV. Exclusion limits are set in the context of bulk radion and graviton models:spin-0 radion resonances are excluded below a mass of 2.7 TeV at 95% confidence level. In the spin-1 heavy vector triplet framework, mass-degenerate W′ and Z′ resonances with dominant couplings to the standard model gauge bosons are excluded below a mass of 2.8 TeV at 95% confidence level. These are the first limits for massive resonances at the TeV scale with these decay channels at $ \sqrt{s}=13 $ TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sensitivity of the NEXT experiment to Xe-124 double electron capture

Double electron capture by proton-rich nuclei is a second-order nuclear process analogous to double beta decay. Despite their similarities, the decay signature is quite different, potentially providing a new channel to measure the hypothesized neutrinoless mode of these decays. The Standard-Model-allowed two-neutrino double electron capture (2$\nu$EC EC) has been predicted for a number of isotopes, but only observed in 78 Kr, 130 Ba and, recently, 124 Xe. The sensitivity to this decay establishes a benchmark for the ultimate experimental goal, namely the potential to discover also the lepton-number-violating neutrinoless version of this process, 0$\nu$EC EC. Here we report on the current sensitivity of the NEXT-White detector to 124 Xe 2$\nu$EC EC and on the extrapolation to NEXT-100. Using simulated data for the 2$\nu$EC EC signal and real data from NEXT-White operated with 124 Xe-depleted gas as background, we define an optimal event selection that maximizes the NEXT-White sensitivity. We estimate that, for NEXT-100 operated with xenon gas isotopically enriched with 1 kg of 124 Xe and for a 5-year run, a sensitivity to the 2$\nu$EC EC half-life of 6 × 10 22 y (at 90% confidence level) or better can be reached.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the inclusive WZ production cross section in pp collisions at $\sqrt{\textrm{s}}$ = 13.6 TeV

The inclusive WZ production cross section is measured in proton-proton collisions at a centre-of-mass energy of 13.6 TeV, using data collected during 2022 with the CMS detector, corresponding to an integrated luminosity of 34.7 fb −1 . The measurement uses multileptonic final states and a simultaneous likelihood fit to the number of events in four different lepton flavour categories: eee, ee μ , μμ e, and μμμ . The selection is optimized to minimize the number of background events, and relies on an efficient prompt lepton discrimination strategy. The WZ production cross section is measured in a phase space defined within a 30 GeV window around the Z boson mass, as σ total (pp → WZ) = 55.2 ± 1.2 (stat) ± 1.2 (syst) ± 0.8 (lumi) ± 0.3 (theo) pb. In addition, the cross section is measured in a fiducial phase space closer to the detector-level requirements. All the measurements presented in this paper are in agreement with standard model predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for $ \mathrm{t}\overline{\mathrm{t}} $ resonances in highly boosted lepton+jets and fully hadronic final states in proton-proton collisions at $ \sqrt{s}=13 $ TeV

A search for the production of heavy resonances decaying into top quark-antiquark pairs is presented. The analysis is performed in the lepton+jets and fully hadronic channels using data collected in proton-proton collisions at $ \sqrt{s}=13 $ TeV using the CMS detector at the LHC, corresponding to an integrated luminosity of 2.6 fb$^{−1}$. The selection is optimized for massive resonances, where the top quarks have large Lorentz boosts. No evidence for resonant $ \mathrm{t}\overline{\mathrm{t}} $ production is found in the data, and upper limits on the production cross section of heavy resonances are set. The exclusion limits for resonances with masses above 2 TeV are significantly improved compared to those of previous analyses at $ \sqrt{s}=8 $ TeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Technical and Imaging Outcomes from the UK Registry of Prostate Artery Embolization (UK-ROPE) Study: Focusing on Predictors of Clinical Success

Introduction: The UK Registry of Prostate Artery Embolization (UK-ROPE) was a prospective, multicentre study comparing PAE against surgical therapies for symptomatic benign prostatic hyperplasia (BPH). A wealth of data was collected supplementary to the main study outcomes which provide a snapshot of UK PAE practice. We aimed to interpret these data in the hope of providing insight into factors which affect clinical outcome and radiation dose. Methods: 216 patients (mean age 66, mean IPSS 21.3) undergoing PAE at 20 British centres from July 2014 to January 2016 were prospectively followed up to 12 months with retrospective analysis of the data. Technical outcome was evaluated based on procedural and fluoroscopy times, skin dose and dose area product (DAP). Clinical outcome was evaluated through collection of Qmax, IPSS reduction and prostate volume reduction. Multiple analysis of variance (MANOVA) was used to assess the significance of various patients and procedural factors on clinical outcome and patient dose. Results: Significant predictors of technical outcome which affected patient skin dose included severity of CTA-detected atheroma (p < 0.001), the practitioner (p < 0.001) and use of protective coil embolization (p = 0.019). Predictors of clinical outcome included initial prostate size (dichotomized into groups > 80 ml and = <80 ml, d = 1, p = 0.0138), embolic agent (spherical particles < 300 nm performed best, p = 0.01) and number of arteries embolized (IPSS reduction of 32.9% in unilateral PAE versus 54.4% for bilateral PAE, p = 0.026). Conclusion: We have identified several important factors which are associated with improved clinical outcome and increased patient dose which we hope will facilitate optimal patient selection and encourage improved embolization technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Benchmark of the No-Core Monte Carlo Shell Model in Light Nuclei

We report the benchmark comparison of the properties in light nuclei among the Monte Carlo Shell Model, Full Configuration Interaction and No Core Full Configuration approaches. For this benchmark process, we compare results for the energies of 9 states from helium-4 to carbon-12 that includes 7 ground states and 2 excited states. The JISP16 NN interaction is adopted. The Coulomb and all other interactions are neglected. The contributions of spurious center-of-mass excitation are not discussed here. The basis space is truncated by the cutoff of the single-particle basis space, N shell . We select the optimal $\hbar$ω that minimizes the energy for that state and basis space cutoff. The MCSM results are obtained by exploiting the recent development in the computation of two-body matrix elements between non-orthogonal Slater determinants and technique of the energy-variance extrapolation. All results are found to be consistent with each other to within quoted uncertainties when they could be quantified. As an exploratory attempt, we also demonstrate how to draw the intrinsic density from no-core MCSM wave functions by taking the 8 Be ground state as an example.

Physics↗

Antibacterial and Structural Properties and Printability of Starch/Clay/Polyethylene Composite Films

A composite of thermoplastic starch (TPS), low-density polyethylene (LDPE) and citric acid-modified montmorillonite (CMMT) was prepared in a twin screw extruder for packaging film application. Starch was first converted to the thermoplastic state by using sorbitol and water. Composite films were produced on a chill roll system and then were modified for printability by grafting of acrylonitrile onto the starch backbone. Antimicrobial property and printability of the films were studied from which the sample with the highest antimicrobial property and the best printability was selected. This optimal sample was then characterized by Fourier transform infrared, thermal gravimetric analysis, differential scanning calorimetry, X-ray diffraction, and scanning electron microscopy. The composite film showed a matrix/dispersed morphology in which LDPE formed a continuous phase and TPS/CMMT nanocomposite particles appeared as dispersed phase. Biodegradability, water absorption, oxygen permeability, tensile strength and transparency of optimal film were also studied. The results indicated very good properties of the produced composite film for packaging application. Graphical Abstract: .

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Effect Laws of Different Factors on Levitation Characteristics of High-T{sub c} Superconducting Maglev System with Numerical Solutions

The interaction between the high-temperature superconducting (HTS) bulk and permanent magnet guideway (PMG) has been a topic among the existing HTS magnetic levitation systems. Up to now, the theories about the electromagnetic and force characteristics have been relatively consummated. Here, using the finite element model by COMSOL Multiphysics 5.3a, we investigated the impact of the intrinsic and external factors on the levitation characteristics of HTS maglev systems, the application laws are concluded. Factors including the critical current density and geometric dimensions of the bulk superconductor, as well as the moving velocity, are discussed. The effects of the multiple back and forth movements are also analyzed. By comparing calculation results of the distributions of the induced current and the levitation force of the bulk superconductor, we can clearly confirm the effect laws of various factors on the electromagnetic characteristics and levitation force. These observations support the physical parameters that are difficult to be tested by experiments. And they also have a significant contribution to the experimental condition selections and optimization of the high-temperature superconducting magnetic levitation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cerebral quantification of N-acetyl aspartate, aspartate, and glutamate levels in local structures of the human brain using J-editing of {sup 1}H magnetic resonance spectra in vivo

A procedure was developed for the first time for simultaneous in vivo quantification of local aspartate and glutamate concentrations in the human brain using {sup 1}H magnetic resonance spectroscopy ({sup 1}H MRS) and spectral J-editing. The MEGA-PRESS pulse sequence was modified to observe β-CH{sub 2} nonequivalent proton resonances of aspartate (δ 2.65 and 2.80) and glutamate (δ 2.04 and 2.12) overlapped by signals of other metabolites. The frequencies, frequency selective pulse durations, and optimal echo times were selected by simulation and experimentally (for phantoms and in the brain in vivo).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗