Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STALLING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Performance of a 1380-foot-per-second-tip-speed axial-flow compressor rotor with a blade tip solidity of 1.3

Aerodynamic design parameters are presented along the overall and blade element performance, of an axial flow compressor rotor designed to study the effects of blade solidity on efficiency and stall margin. At design speed the peak efficiency was 0.844 and occurred at an equivalent weight flow of 63.5 lb/sec with a total pressure ratio of 1.801. Design efficiency, pressure ratio, and weight flow 0.814, 1.65, and 65.3(41.1 lb/sec/sq ft of annulus area), respectively. Stall margin for design speed was 6.4 percent based on the weight flow and pressure ratio values at peak efficiency and just prior to stall.

Hager, R. D.↗

Delta wing separation can dominate shuttle dynamics.

The unsteady aerodynamics of the delta wing, high cross range, shuttle orbiter have been investigated. Three potentially dangerous flow separation phenomena involving the delta wing have been identified, each of which could seriously compromise the flight dynamics. They are (1) leeside shock-induced separation, (2) sudden leading-edge stall, and (3) the subsonic leading-edge vortex and vortex burst. Each of these unsteady flow phenomena can be triggered by control surface deflection. Furthermore, wing stall and control-induced separation effects interact with the relatively large fuselage, causing simultaneous alteration of the lateral-directional stability. Trajectory shaping may be the most powerful means of dealing with these stall effects.

Reding, J. P.↗

Large-Angle Motion Tests, Including Spins, of A Free-Flying Radio-Controlled 0.13-Scale Model of A Twin Jet Swept Wing Fighter Airplane

An investigation has been conducted with a free-flying radio-controlled 0.15-scale model of a twin-jet swept-wing fighter airplane to determine the tendency of this design to enter spins and to evaluate the nature of the spin obtained from post-stall motions. The test results indicate that it may be difficult to obtain a developed spin on the airplane, particularly the flat-type spin. Two types of erect developed spins will be possible; one will be flat and fast rotating from which recovery may not be obtained and the other will be steeper and oscillatory from which recoveries will be satisfactory. Controls will be effective for satisfactory termination of the post-stall gyrations obtained. The recommended recovery technique from both post-stall gyrations and developed spins will be movement of the rudder to oppose the yawing rotation and simultaneous movement of the ailerons to with the rotation (stick right when turning to the right). When recovery is imminent, the stick should be moved longitudinally to neutral. It is recommended that the spin not be allowed to develop fully on this airplane. The developed-spin results obtained in the investigation were in good agreement with spin-tunnel results.

Sanger M Burk, Jr↗

High loading, 1800 ft/sec tip speed, transonic compressor fan stage. 2: Final report

Tests were conducted on a 0.5 hub/tip ratio, single-stage fan-compressor designed to produce a pressure ratio of 2.285 an efficiency of 84 percent with a rotor tip speed of 1800 feet per second. A peak efficiency of 82 percent was achieved by the stage at a stall margin of 6.5 percent. Tests showed that stall-limit line was slightly sensitive to tip-radial distortion, but stall-line improvements were noted when the stage was subjected to circumferential and hub-radial flow distortions. Rotor blade passage and trailing edge shock positions were inferred from static pressure contours over the rotor tips.

Morris, A. L.↗

Overall and blade-element performance of a transonic compressor stage with multiple-circular-arc blades at tip speed of 419 meters per second

A 50-centimeter-diameter axial-flow transonic compressor stage with multiple-circular-arc blades was designed and tested to study the effects of blade shape on efficiency and stall margin. At design speed, peak efficiency of 0.80 occurred at an equivalent weight flow of 29.0 kilograms per second. Measured total pressure ratio and total temperature ratio at peak efficiency were 1.69 and 1.20, respectively. The stall margin at design speed and an equivalent weight flow of 29.0 kilograms per second was 9 percent. The measured stall margin at design weight flow and speed was 15 percent. A comparison of rotor performance made with and without the stator showed a decrease in pressure ratio, peak efficiency, and maximum weight flow with the addition of the stator.

Kovich, G.↗

Overall and blade-element performance of a multiple-circular-arc bladed transonic compressor rotor with tip speed of 1375 feet per second

The design and experimental performance of a 20-inch-diameter multiple-circular-arc bladed axial-flow transonic compressor rotor is presented. Radial surveys of the flow conditions were made. At design speed the peak efficiency was 0.882 and occurred at a weight flow of 64.0 pounds per second. At this point the total-pressure and total-temperature ratios were 1.79 and 1.205, respectively. The stall margin at design speed was 8 percent based on weight flows and total-pressure ratios at experimental peak efficiency and near stall. The measured stall margin was 20 percent at design weight flow and speed.

Kovich, G.↗

Wind tunnel investigation of effects of variations in Reynolds number and leading-edge treatment on the aerodynamic characteristics of an externally blown jet-flap configuration

An investigation has been conducted in a full-scale tunnel to determine the effects of variations in Reynolds number and leading-edge treatment on the aerodynamic characteristics of an externally blown jet-flap transport configuration. The model had a double-slotted trailing-edge flap and was powered by four high-bypass-ratio turbofan engines. Tests were performed by using each of three leading-edge devices (a 30-percent-chord flap and 15- and 25-percent-chord slats) at Reynolds numbers from 0.47 x one million to 1.36 x one million thrust coefficients up to 3.5. The use of a 25-percent-chord slat was found to be more effective than a 15-percent-chord slat or a 30-percent-chord flap in extending the stall angle of attack and in minimizing the loss of lift after the stall. The large slat was also effective in reducing the rolling moments that occurred when the engine-out wing stalled first.

Parlett, L. P.↗

Some comparisons of the flow characteristics of a turbofan compressor system with and without inlet pressure distortion

The measured effects of a circumferential distortion in inlet total pressure on the fan, low, and high compressor of an afterburning turbofan engine are presented and discussed. Extensive inner-stage instrumentation, combined with a unique test technique offered an accurate means of measuring the shifts in flow, performance, and stall mechanisms within the compressor. These effects are compared at one speed to the corresponding effects measured with undistorted inlet flow. The results show the rate at which the distorted flow areas were attenuated and rotated as well as the change in flow velocities that occurred at various points in the compressor. High response pressure traces indicated the location of stalls including the sequence of dynamic events from the onset and propagation of various stall-recovery events, to compressor surge, to the resulting hammershock.

Evans, D. G.↗

Formulation of a distortion index based on peak compressor pressure ratios

In order to effectively use a compressor face total-pressure distortion index as a measure of inlet-engine compatibility, a correlation of distortion amplitude with stall margin must be developed with minimal scatter. A recent analysis of data recorded in extensive distortion screen tests with the J85-GE-13 turbojet engine has resulted in a correlation based on compressor discharge pressure ratioed to the minimum pressure at the compressor face. Simply by determining compressor stall lines with a single hub radial distortion pattern, a single tip radial pattern, and with undistorted inflow, the overall compressor pressure ratio at stall for even the most complex distortion pattern was found to be predictable.

Calogeras, J. E.↗

Wind-tunnel investigation to determine the low speed yawing stability derivatives of a twin jet fighter model at high angles of attack

An investigation was conducted to determine the low-speed yawing stability derivatives of a twin-jet fighter airplane model at high angles of attack. Tests were performed in a low-speed tunnel utilizing variable-curvature walls to simulate pure yawing motion. The results of the study showed that at angles of attack below the stall the yawing derivatives were essentially independent of the yawing velocity and sideslip angle. However, at angles of attack above the stall some nonlinear variations were present and the derivatives were strongly dependent upon sideslip angle. The results also showed that the rolling moment due to yawing was primarily due to the wing-fuselage combination, and that at angles of attack below the stall both the vertical and horizontal tails produced significant contributions to the damping in yaw. Additionally, the tests showed that the use of the forced-oscillation data to represent the yawing stability derivatives is questionable, at high angles of attack, due to large effects arising from the acceleration in sideslip derivatives.

Coe, P. L., Jr.↗

Some comparisons of the flow characteristics of a turbofan compressor system with and without inlet pressure distortion

The measured effects of a circumferential distortion in inlet total pressure on the fan, low, and high compressor of an afterburning turbofan engine are presented and discussed. Extensive inner-stage instrumentation, combined with a unique test technique offered an accurate means of measuring the shifts in flow, performance, and stall mechanisms within the compressor. These effects are compared at one speed to the corresponding effects measured with undistorted inlet flow. The results show the rate at which the distorted flow areas were attenuated and rotated, as well as the change in flow velocities that occurred at various points in the compressor. High response pressure traces indicated the location of stalls including the sequence of dynamic events from the onset and propagation of various stall-recovery events, to compressor surge, to the resulting hammershock.

Evans, D. G.↗

Formulation of a distortion index based on peak compressor pressure ratios

In order to effectively use a compressor face total-pressure distortion index as a measure of inlet-engine compatibility, a correlation of distortion amplitude with stall margin must be developed with minimal scatter. A recent analysis of data recorded in extensive distortion screen tests with the J85-GE-13 turbojet engine has resulted in a correlation based on compressor discharge pressure ratioed to the minimum pressure at the compressor face. Simply by determining compressor stall lines with a single hub radial distortion pattern, a single tip radial pattern, and with undistorted inflow, the overall compressor pressure ratio at stall for even the most complex distortion pattern was found to be predictable.

Calogeras, J. E.↗

Stator hub treatment study

The results of an experimental research program to investigate the potential of improving compressor stall margin by the application of hub treatment are presented. Extensive tuft probing showed that the two-stage, 0.5 radius ratio compressor selected for the test was indeed hub critical. Circumferential groove and baffled wide blade angle slot hub treatments under the stators were tested. Performance measurements were made with total and static pressure probes, wall static pressure taps, flow angle measuring instrumentation and hot film anemometers. Stator hub treatment was not found to be effective in improving compressor stall margin by delaying the point of onset of rotating stall or in modifying compressor performance for any of the configurations tested. Extensive regions of separated flow were observed on the suction surface of the stators near the hub. However, the treatment did not delay the point where flow separation in the stator hub region becomes apparent.

Wisler, D. C.↗

Performance of inlet stage of transonic compressor

The overall and blade-element performances are presented over the stable flow operating range of the stage at the design tip speed of 426 m/sec. Stage peak efficiency of 0.83 was obtained at a weight flow of 28.8 kg/sec and a pressure ratio of 1.52. The stall margin for the stage was 8 percent based on weight flow and pressure ratio at peak efficiency and stall. The rotor appears to be stalling prematurely as evidenced by high rotor tip losses.

Urasek, D. C.↗

Evaluation of an envelope-limiting device using simulation and flight test of a remotely piloted research vehicle

The operating characteristics of a nonlinear envelope-limiting device were investigated at extreme flight conditions by using a real time digital aircraft spin simulation and flight tests of a scale model remotely piloted research vehicle. A digital mechanization of the F-15 control system, including the stall inhibiter, was used in the simulation and in the control system of the scale model. The operational characteristics of the stall inhibiter and the effects of the stall inhibiter on the spin susceptibility of the airplane were investigated.

Petersen, K. L.↗

Effects of tip clearance on overall performance of transonic fan stage with and without casing treatment

The overall performance of a transonic fan stage is presented for various tip clearances, with and without casing treatment. The stage was tested with a solid casing, and with open skewed slots and closed skewed slots in the casing over the rotor blade tips. Four nominal nonrotating rotor blade tip clearances from 0.061 to 0.178 centimeter were used. For all three casings, the pressure ratio and efficiency decreased with increasing tip clearance. The stall margin for a given casing also decreased with increasing clearance. At design speed and a given tip clearance, the highest stall margin was obtained with the open-slot casing, and the lowest stall margin was obtained with the solid casing.

Moore, R. D.↗

Effect of casing treatment of overall performance of axial-flow transonic fan stage with pressure ratio of 1.75 and tip solidity of 1.5

The effect of a number of casing treatments on the overall performance of a 1.75-pressure-ratio, 423-m/sec-tip-speed fan stage was evaluated. The skewed slot configuration with short-open slots over the midportion of the rotor had a stall margin of 23.5 percent, while the solid casing had a stall margin of 15.0 percent. The skewed slot configuration with long open slots extending ahead of and over portion of rotor displaced the stall line to the lowest flow at all speeds tested. At design speed, the peak efficiency for the long, forward open slots was 1 point less than that for the short midopen slots and 3 points less than that for the solid casing.

Osborn, W. M.↗

Analysis of internal flow of J85-13 multistage compressor

Interstage data recorded on a J85-13 engine were used to analyze the internal flow of the compressor. Measured pressures and temperatures were used as input to a streamline analysis program to calculate the velocity diagrams at the inlet and outlet of each blade row. From the velocity diagrams and blade geometry, selected blade-element performance parameters were calculated. From the detailed analysis it is concluded that the compressor is probably hub critical (stall initiates at the hub) in the latter stages for the design speed conditions. As a result, the casing treatment over the blade tips has little or no effect on stall margin at design speed. Radial inlet distortion did not appear to change the flow in the stages that control stall because of the rapid attenuation of the distortion within the compressor.

Hager, R. D.↗