Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SOLUTIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Evolution of discontinuous solutions to transport equations in stellarators

It was shown earlier that, in the range of rare collisions, transport equations for stellarators allow steady discontinuous solutions for the ambipolar electric field and for the plasma density and temperature gradients. Moreover, such solutions are non-single-valued; that is, their explicit form depends on the initial values of the ambipolar electric field. The time-independent transport equations are derived under the conventional quasineutrality condition; i.e., it is assumed that the electron and ion densities, N{sub e} and N{sub i}, are related by the relationship N{sub e} = ZN{sub i} (where Z is the ion charge number). In other words, the plasma charge density is assumed to be much less than the product e{sub i}N{sub i}. Under typical conditions, the corresponding inequality is satisfied by a large margin. However, if the electric field E has discontinuities, then it can be seen from the equation {nabla}.E = 4{pi}{rho} that, at the discontinuity points, the charge density becomes infinite and the relationship N{sub e} = ZN{sub i} fails to hold, so it is necessary to replace it with N{sub e} = ZN{sub i} + {rho}/e{sub e}. In the transport equations, this latter replacement produces additional terms, proportional to the second radial derivative of the field E. With these additional terms, the steady solutions are modified substantially. First, the ambipolar field and the derivatives of the density and temperatures all become continuous functions of the coordinates, a result that seems to be quite obvious. The second, not-so-obvious result is that the steady solutions become single-valued, i.e., independent of the initial values of the ambipolar electric field. It turns out that, in this case, two regimes are possible, depending on the values of the plasma parameters. In the first regime, the solution is unique and is independent of the initial conditions. In the second regime, two steady solutions can exist, depending on the initial conditions. One of the solution is similar to that obtained in the first regime, and the other differs from the first one both in the ambipolar field profile and in the dependence of the density and temperatures on the minor plasma radius. It cannot be excluded that different plasma confinement modes revealed in experiments are associated with the existence of such solutions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Multi-physics (Multiphase CFD + MCNP) simulation for generic solution vessel power calculation

The current study aims to predict the steady state power of a generic solution vessel and to develop a corresponding heat transfer coefficient correlation for a Moly99 production facility by conducting a fully coupled multi-physics simulation. A prediction of steady state power for the current application is inherently interconnected between thermal hydraulic characteristics (i.e. Multiphase computational fluid dynamics solved by ANSYS-Fluent 17.2) and the corresponding neutronic behavior (i.e. particle transport solved by MCNP6.2) in the solution vessel. Thus, the development of a coupling methodology is vital to understand the system behavior at a variety of system design and postulated operating scenarios. In this study, we report on the k-effective (keff) calculation for the baseline solution vessel configuration with a selected solution concentration using MCNP K-code modeling. The associated correlation of thermal properties (e.g. density, viscosity, thermal conductivity, specific heat) at the selected solution concentration are developed based on existing experimental measurements in the open literature. The numerical coupling methodology between multiphase CFD and MCNP is successfully demonstrated, and the detailed coupling procedure is documented. In addition, improved coupling methods capturing realistic physics in the solution vessel thermal-neutronic dynamics are proposed and tested further (i.e. dynamic height adjustment, mull-cell approach). As a key outcome of the current study, a multi-physics coupling methodology between MCFD and MCNP is demonstrated and tested for four different operating conditions. Those different operating conditions are determined based on the neutron source strength at a fixed geometry condition. The steady state powers for the generic solution vessel at various operating conditions are reported, and a generalized correlation of the heat transfer coefficient for the current application is discussed. The assessment of multi-physics methodology and preliminary results from various coupled calculations (power prediction and heat transfer coefficient) can be further utilized for the system code validation and generic solution vessel design improvement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hybrid Analytics Solution to Improve Coal Power Plant Operations

This project focused on developing advanced methods for thermal performance monitoring of a coal-fueled power plant. The specific goal was to develop and demonstrate a new thermal performance monitoring approach using a hybrid model that integrates a physics-based heat balance model with a machine learning-based pattern recognition model. The hybrid model enables increased accuracy and scope of the thermal analysis and an improved ability to monitor and detect changes in plant operation. This new approach takes full advantage of the individual model capabilities and creates an important new set of capabilities not previously possible using the two types of models separately. Using the heat balance model, a rich set of derived parameters (virtual sensors) are calculated from the measured plant operating data at each time point. The combined measured and derived data values are used by machine learning algorithms to create pattern recognition models over the range of normal unit operation. To create the monitoring models, historical data from normal operation of the plant is first processed by the heat balance model to compute the derived parameter data. The result is a greatly expanded set of normal operating data that can be used as input to create the pattern recognition model. Once the models are calibrated for normal operation, the hybrid model is suitable for use in continuous online monitoring. During online monitoring, new plant operating data is processed first by the heat balance model and then by the pattern recognition model. Results from the pattern recognition model quantify the deviation of each measured or derived parameter from its expected value in normal operation. The hybrid models can detect abnormal changes in plant operating data with very high accuracy and sensitivity. When abnormal behavior is detected, alerts are generated automatically for evaluation by the plant monitoring staff. The new hybrid solution product was developed and verified in the performance of the project. The hybrid solution was tested first in a simulation environment that mimicked the plant data systems and infrastructure used by U.S. power generating plants and utilities. The hybrid solution was then deployed for real-time, online monitoring of an operating coal-fueled power plant at a field test site. Field testing demonstrated that all hybrid solution development objectives were accomplished. The project work was based on combining the capabilities of two existing software products to create the new hybrid solution product. One of these was the existing MapEx® heat balance product and the other was the existing SureSense® advanced pattern recognition product. Each of these separate products was assessed to be at a Technology Readiness Level (TRL) of 9 at the start of the effort. The hybrid solution product was assessed to be at a TRL of 2 at the start of the project based on early feasibility work by the project team. At completion of the field testing performed in the project, the hybrid solution product was assessed to be at a TRL of 7. The project team expects that the hybrid solution product will be deployed commercially and will achieve a TRL of 9 within one year after completion of the project.

01 COAL, LIGNITE, AND PEAT↗

SODIUM ALUMINOSILICATE FOULING AND CLEANING OF DECONTAMINATED SALT SOLUTION COALESCERS

During initial non-radioactive operations at the Modular Caustic Side Solvent Extraction Unit (MCU), the pressure drop across the decontaminated salt solution coalescer reached {approx}10 psi while processing {approx}1250 gallons of salt solution, indicating possible fouling or plugging of the coalescer. An analysis of the feed solution and the 'plugged coalescer' concluded that the plugging was due to sodium aluminosilicate solids. MCU personnel requested Savannah River National Laboratory (SRNL) to investigate the formation of the sodium aluminosilicate solids (NAS) and the impact of the solids on the decontaminated salt solution coalescer. Researchers performed developmental testing of the cleaning protocols with a bench-scale coalescer container 1-inch long segments of a new coalescer element fouled using simulant solution. In addition, the authors obtained a 'plugged' Decontaminated Salt Solution coalescer from non-radioactive testing in the MCU and cleaned it according to the proposed cleaning procedure. Conclusions from this testing include the following: (1) Testing with the bench-scale coalescer showed an increase in pressure drop from solid particles, but the increase was not as large as observed at MCU. (2) Cleaning the bench-scale coalescer with nitric acid reduced the pressure drop and removed a large amount of solid particles (11 g of bayerite if all aluminum is present in that form or 23 g of sodium aluminosilicate if all silicon is present in that form). (3) Based on analysis of the cleaning solutions from bench-scale test, the 'dirt capacity' of a 40 inch coalescer for the NAS solids tested is calculated as 450-950 grams. (4) Cleaning the full-scale coalescer with nitric acid reduced the pressure drop and removed a large amount of solid particles (60 g of aluminum and 5 g of silicon). (5) Piping holdup in the full-scale coalescer system caused the pH to differ from the target value. Comparable hold-up in the facility could lead to less effective cleaning and precipitation of bayerite solid particles. (6) Based on analysis of the cleaning solutions from the full-scale test, the 'dirt capacity' of a 40 inch coalescer for these NAS solids was calculated to be 40-170 grams.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

REMOVAL OF SOLIDS FROM HIGHLY ENRICHED URANIUM SOLUTIONS USING THE H-CANYON CENTRIFUGE

Prior to the dissolution of Pu-containing materials in HB-Line, highly enriched uranium (HEU) solutions stored in Tanks 11.1 and 12.2 of H-Canyon must be transferred to provide storage space. The proposed plan is to centrifuge the solutions to remove solids which may present downstream criticality concerns or cause operational problems with the 1st Cycle solvent extraction due to the formation of stable emulsions. An evaluation of the efficiency of the H-Canyon centrifuge concluded that a sufficient amount (> 90%) of the solids in the Tank 11.1 and 12.2 solutions will be removed to prevent any problems. We based this conclusion on the particle size distribution of the solids isolated from samples of the solutions and the calculation of particle settling times in the centrifuge. The particle size distributions were calculated from images generated by scanning electron microscopy (SEM). The mean particle diameters for the distributions were 1-3 {micro}m. A significant fraction (30-50%) of the particles had diameters which were < 1 {micro}m; however, the mass of these solids is insignificant (< 1% of the total solids mass) when compared to particles with larger diameters. It is also probable that the number of submicron particles was overestimated by the software used to generate the particle distribution due to the morphology of the filter paper used to isolate the solids. The settling times calculated for the H-Canyon centrifuge showed that particles with diameters less than 1 to 0.5 {micro}m will not have sufficient time to settle. For this reason, we recommend the use of a gelatin strike to coagulate the submicron particles and facilitate their removal from the solution; although we have no experimental basis to estimate the level of improvement. Incomplete removal of particles with diameters < 1 {micro}m should not cause problems during purification of the HEU in the 1st Cycle solvent extraction. Particles with diameters > 1 {micro}m account for > 99% of the solid mass and will be efficiently removed by the centrifuge; therefore, the formation of emulsions during solvent extraction operations is not an issue. Under the current processing plan, the solutions from Tanks 11.1 and 12.2 will be transferred to the enriched uranium storage (EUS) tank following centrifugation. The solution from Tanks 11.1 and 12.2 may remain in the EUS tank for an extended time prior to purification. The effects of extended storage on the solution were not evaluated as part of this study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Low-temperature solution growth of ZnO nanotube arrays

Single crystal ZnO nanotube arrays were synthesized at low temperature in an aqueous solution containing zinc nitrate and hexamethylenetetramine. It was found that the pH value of the reaction solution played an important role in mediating the growth of ZnO nanostructures. A change in the growth temperature might change the pH value of the solution and bring about the structure conversion of ZnO from nanorods to nanotubes. It was proposed that the ZnO nanorods were initially formed while the reaction solution was at a relatively high temperature (~90 °C) and therefore enriched with colloidal Zn(OH) 2 , which allowed a fast growth of ZnO nanocrystals along the [001] orientation to form nanorods. A decrease in the reaction temperature yielded a supersaturated solution, resulting in an increase in the concentration of OH - ions as well as the pH value of the solution. Colloidal Zn(OH) 2 in the supersaturated solution trended to precipitate. However, because of a slow diffusion process in view of the low temperature and low concentration of the colloidal Zn(OH) 2 , the growth of the (001) plane of ZnO nanorods was limited and only occurred at the edge of the nanorods, eventually leading to the formation of a nanotube shape. In addition, it was demonstrated that the pH might impact the surface energy difference between the polar and non-polar faces of the ZnO crystal. Such a surface energy difference became small at high pH and hereby the prioritized growth of ZnO crystal along the [001] orientation was suppressed, facilitating the formation of nanotubes. This paper demonstrates a new strategy for the fabrication of ZnO nanotubes on a large scale and presents a more comprehensive understanding of the growth of tube-shaped ZnO in aqueous solution at low temperature.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Comments on the Leimanis solution of self-excited rigid body

An attempt is made to apply the solutions contained in a book by Leimanis (1965), which includes the Bodewadt solution, to the performance assessment of the Galileo spacecraft during spin up and spin down maneuvers. Because the Galileo is not precisely symmetric, however, the Bodewadt solution fails to achieve the desired accuracy for useful analysis. It is noted that in the case of the Leimanis solution, the analytic results are incorrect for theoretical reasons. In order to remedy this situation, analytic solutions are developed which satisfy the criterion of high accuracy and provide a useful analytic tool for the performance assessment and maneuver analysis of the Galileo spacecraft and many similar near symmetric spinning spacecraft. Simulation results suggest the relative accuracies of the Bodewadt solution and the author's solution, while the restricted regions of validity of the Leimanis solution are clearly indicated.

Longuski, J. M.↗

Multiple transonic solutions with a new class of shock transitions in steady isothermal solar and stellar winds

It is shown that a new class of shock transitions arises in the transonic solutions of the steady isothermal solar wind equations when momentum deposition and/or nonradial flow tube divergence give rise to multiple critical points in the flow. These shock transitions between critical solutions occur for a certain range of the parameters which characterize the momentum deposition function. The isothermal wind equations allow multiple transonic solutions in the presence of such shock transitions, yielding a continuous solution passing through an inner critical point and solutions involving a shock transition between critical solutions. It is determined that these multiple transonic solutions have the same flow speed at the base but different supersonic flow speeds at infinity. It is found that the nonradial flow tube divergence and momentum addition are equivalent, which gives rise to multiple critical points and hence to multiple transonic solutions with shock transitions. In addition, the physical relevance of these properties are examined for astrophysical systems such as the inner solar wind, flows in extragalactic jets, and accretion discs.

Habbal, S. R.↗

Method and apparatus for minimizing convection during crystal growth from solution

A method and apparatus are disclosed for growing in a gravitational field a microscopic crystal from a solution. The solution is held in a vertical chamber which is relatively thin, the thin being generally perpendicular to the vertical. There is a substrate crystal disposed at either the upper or lower end of the chamber and the crystal grows from this substrate crystal in one direction. The temperature conditions of the solution are controlled so that, as the crystal forms, the effects of buoyant convection within the solution are minimized. This is accomplished in two different ways depending upon whether the crystal is grown from the upper or lower end of the chamber. When grown from the upper end of the chamber, the temperature of the solution is controlled so that it remains essentially isothermal so that there is essentially no heat loss from the solution. When the crystal is grown from the lower end of the chamber, the temperature of the solution is controlled so that there is a differential in temperature throughout the solution which provides a positive thermal gradient within the chamber.

Shlichta, P. J.↗

Effect of solution concentration and aging conditions on PMR-15 resin

High performance liquid chromatography is utilized to evaluate the effect of temperature, solution concentration, and aging time on PMR-15 resin solutions. Fifty- and 70-wt percent PMR-15 resin solutions were prepared from the mixture of 5-norbornene-2,3-dicarboxylic ester (NE) acid, 4.4'-methylenedianiline (MDA), methanol, and 3,3',4.4.-benzophenonetetracarboxylic dimethyl ester (BTDE) acid solution. It is observed that in PMR-15 resin solution aged for 35 days at room temperature NE and MDA react to form amide and imide intermediates. The precipitation data reveal that in the 70-wt percent solution precipitation occurs after 12 days and in the 50-wt percent solution after 20 days; however, at lower temperatures (-11 C, and 2 C) no precipitation is detected. It is concluded that storage of resin solutions and powders at reduced temperatures extends shelf life by reducing the rate of imide formation.

Roberts, G. D.↗

Nature of fluid flows in differentially heated cylindrical container filled with a stratified solution

Semiconductor crystals such as Hg(1-x)Cd(x)Te grown by unidirectional solidification Bridgmann method have shown compositional segregations in both the axial and radial directions. Due to the wide separation between the liquidus and the solidus of its pseudobinary phase diagram, there is a diffusion layer of higher HgTe content built up in the melt near the melt-solid interface which gives a solute concentration gradient in the axial direction. Because of the higher thermal conductivity in the melt than that in the crystal there is a thermal leakage through the fused silica crucible wall near the melt-solid interface. This gives a thermal gradient in the radial direction. Hart (1971), Thorpe, Hutt and Soulsby (1969) have shown that under such condition a fluid will become convectively unstable as a result of different diffusivities of temperature and solute. It is quite important to understand the effects of this thermosolute convection on the compositional segregation in the unidirectionally solidified crystals. To reach this goal, we start with a simplified problem. We study the nature of fluid flows of a stratified solution in a cylindrical container with a radial temperature gradient. The cylindrical container wall is considered to be maintained at a higher temperature than that at the center of the solution and the solution in the lower gravitational direction has higher solute concentration which decrease linearly to a lower concentration and then remain constant to the top of the solution. The sample solution is taken to be salt water.

Wang, Jai-Ching↗

Device and method for screening crystallization conditions in solution crystal growth

A device and method for detecting optimum protein crystallization conditions and for growing protein crystals in either 1g or microgravity environments comprising a housing, defining at least one pair of chambers for containing crystallization solutions is presented. The housing further defines an orifice therein for providing fluid communication between the chambers. The orifice is adapted to receive a tube which contains a gelling substance for limiting the rate of diffusive mixing of the crystallization solutions. The solutions are diffusively mixed over a period of time defined by the quantity of gelling substance sufficient to achieve equilibration and to substantially reduce density driven convection disturbances therein. The device further includes endcaps to seal the first and second chambers. One of the endcaps includes a dialysis chamber which contains protein solution in which protein crystals are grown. Once the endcaps are in place, the protein solution is exposed to the crystallization solutions wherein the solubility of the protein solution is reduced at a rate responsive to the rate of diffusive mixing of the crystallization solutions. This allows for a controlled approach to supersaturation and allows for screening of crystal growth conditions at preselected intervals.

Carter, Daniel C.↗

Device and Method for Screening Crystallization Conditions in Solution Crystal Growth

A device and method for detecting optimum protein crystallization conditions and for growing protein crystals in either 1 g or microgravity environments comprising a housing defining at least one pair of chambers for containing crystallization solutions. The housing further defines an orifice therein for providing fluid communication between the chambers. The orifice is adapted to receive a tube which contains a gelling substance for limiting the rate of diffusive mixing of the crystallization solutions. The solutions are diffusively mixed over a period of time defined by the quantity of gelling substance sufficient to achieve equilibration and to substantially reduce density driven convection disturbances therein. The device further includes endcaps to seal the first and second chambers. One of the endcaps includes a dialysis chamber which contains protein solution in which protein crystals are grown. Once the endcaps are in place. the protein solution is exposed to the crystallization solutions wherein the solubility of the protein solution is reduced at a rate responsive to the rate of diffusive mixing of the crystallization solutions. This allows for a controlled approach to supersaturation and allows for screening of crystal growth conditions at preselected intervals.

Carter, Daniel C.↗

A System for Managing Replenishment of a Nutrient Solution Using an Electrical Conductivity Controller

Control of nutrient solution parameters is very important for the growth and development of plants grown hydroponically. Protocols involving different nutrient solution replenishment times (e.g. one-week, two-week, or two-day replenishment) provide manual periodic control of the nutrient solution's electrical conductivity (EC). Since plants take-up nutrients as they grow, manual control has a drawback in that EC is not held constant between replenishments. In an effort to correct this problem the Center for Food and Environmental Systems for Human Exploration of Space at Tuskegee University has developed a system for managing and controlling levels of EC over a plant's entire growing cycle. A prototype system is being tested on sweetpotato production using the nutrient film technique (NFT), and it is being compared to a system in which sweetpotatoes are grown using NFT with manual control. NASA has played an important role in the development of environmental control systems. They have become a forerunner in growing plants hydroponically with some control systems through the use of networked data acquisition and control using environmental growth chambers. Data acquisition systems which involve the use of real-time, calibration, set points, user panel, and graphical representation programming provide a good method of controlling nutrient solution parameters such as EC and pH [Bledsoe, 19931]. In NASA's Biomass Production Chamber (BPC) at Kennedy Space Center, control is provided by a programmable logic controller (PLC). This is an industrial controller which combines ladder computer logic which has the ability to handle various levels of electrical power. The controller controls temperature, light and other parameters that affect the plant's environment, in the BPC, the Nutrient Delivery System (NIX), a sub-system of the PLC, controls nutrient solution parameters such as EC, pH, and solution levels. When the nutrient EC measurement goes outside a preset range (120-130 mS/m) a set amount of a stock solution of nutrients is automatically added by a metering pump to bring the EC back into operating range [Fortson, 1992]. This paper describes a system developed at Tuskegee University for controlling the EC of a nutrient solution used for growing sweetpotatoes with an EC controller and a computer with LabView data acquisition and instrumentation software. It also describes the preliminary data obtained from the growth of sweetpotatoes using this prototype control system.

Davis, D.↗

Solution-Phase Processes of Macromolecular Crystallization

We have proposed, for the tetragonal form of chicken egg lysozyme, that solution phase assembly processes are needed to form the growth units for crystal nucleation and growth. The starting point for the self-association process is the monomeric protein, and the final crystallographic symmetry is defined by the initial dimerization interactions of the monomers and subsequent n-mers formed, which in turn are a function of the crystallization conditions. It has been suggested that multimeric proteins generally incorporate the underlying multimers symmetry into the final crystallographic symmetry. We posed the question of what happens to a protein that is known to grow as an n-mer when it is placed in solution conditions where it is monomeric. The trypsin-treated, or cut, form of the protein canavalin (CCAN) has been shown to nucleate and grow crystals as a trimer from neutral to slightly acidic solutions. Under these conditions the solution is composed almost wholly of trimers. The insoluble protein can be readily dissolved by weakly basic solution, which results in a solution that is monomeric. There are three possible outcomes to an attempt at crystallization of the protein under monomeric (high pH) conditions: 1) we will obtain the same crystals as under trimer conditions, but at different protein concentrations governed by the self association equilibria; 2) we will obtain crystals having a different symmetry, based upon a monomeric growth unit; 3) we will not obtain crystals. Obtaining the first result would be indicative that the solution-phase self-association process is critical to the crystal nucleation and growth process. The second result would be less clear, as it may also reflect a pH-dependent shift in the trimer-trimer molecular interactions. The third result, particularly for experiments in the transition pH's between trimeric and monomeric CCAN, would indicate that the monomer does not crystallize, and that solution phase self association is not part of the crystal nucleation and growth path. Results are presented for crystallization experiments of CCAN over the pH 6.8 to 9.6 range.

Pusey, Marc L.↗

Method for minimizing convection during crystal growth from solution

Disclosed is a method and apparatus for growing in a gravitational field a microscopic crystal from a solution. Solution is held in a vertical chamber which is relatively thin, the thin dimension being generally perpendicular to the vertical. There is a substrate crystal disposed at either the upper or lower end of the chamber and the crystal grows from this substrate crystal in one direction. In accordance with this invention, the temperature conditions of the solution are controlled so that as the crystal forms the effects of buoyant convection within the solution are minimized. This is accomplished in two different ways depending upon whether the crystal is grown from the upper or lower end of the chamber. When grown from the upper end of the chamber, the temperature of the solution is controlled so that it remains essentially isothermal so that there is essentially no heat loss from the solution. When the crystal is grown from the lower end of the chamber, the temperatures of the solution is controlled so that there is a differential in temperature throughout the solution which provides a positive thermal gradient within the chamber.

Shlichta, Paul J.↗

Weekly Solutions of Time-Variable Gravity from 1993 to 2010

The GRACE mission has been highly successful in determining the time-variable gravity field of the Earth, producing monthly or even more frequent solutions (cf. 10-day) solutions using both spherical harmonics and mascons. However the GRACE time series only commences in 2002 - 2003 and a gap of several years may occur in the series before a GRACE follow-on satellite is launched. Satellites tracked by SLR and DORIS have also been used to study time variations in the Earth's gravitational field. These include (most recently) the solutions of Cox and Chao (2002), Cheng et al. (2004, 2007) and Lemoine et al. (2007). In this paper we discuss the development of a new time series of low degree spherical harmonic fields based on the available SLR, DORIS and GPS data. We develop simultaneous solutions for both the geocenter and the low degree harmonics up to 5x5. The solutions integrate data from SLR geodetic satellites (e.g., Lageos1, Lageos2, Starlette, Stella, Ajisai, Larets, Westpac), altimetry satellites (TOPEX/Poseidon, Envisat, Jason-1, Jason-2), and satellites tracked solely by DORIS (e.g. SPOT2-5). We discuss some pertinent aspects of the satellite-specific modeling. We include altimeter crossovers in the weekly solutions where feasible and time permits. The resulting geocenter time series is compared with geophysical model predictions and other independently-derived solutions. Over the GRACE time period the fidelity and consistency with the GRACE solutions are presented.

Lemoine, F.↗

Solution Preserves Nucleic Acids in Body-Fluid Specimens

A solution has been formulated to preserve deoxyribonucleic acid (DNA) and ribonucleic acid (RNA) in specimens of blood, saliva, and other bodily fluids. Specimens of this type are collected for diagnostic molecular pathology, which is becoming the method of choice for diagnosis of many diseases. The solution makes it possible to store such specimens at room temperature, without risk of decomposition, for subsequent analysis in a laboratory that could be remote from the sampling location. Thus, the solution could be a means to bring the benefits of diagnostic molecular pathology to geographic regions where refrigeration equipment and diagnostic laboratories are not available. The table lists the ingredients of the solution. The functions of the ingredients are the following: EDTA chelates divalent cations that are necessary cofactors for nuclease activity. In so doing, it functionally removes these cations and thereby retards the action of nucleases. EDTA also stabilizes the DNA helix. Tris serves as a buffering agent, which is needed because minor contaminants in an unbuffered solution can exert pronounced effects on pH and thereby cause spontaneous degradation of DNA. SDS is an ionic detergent that inhibits ribonuclease activity. SDS has been used in some lysis buffers and as a storage buffer for RNA after purification. The use of the solution is straightforward. For example, a sample of saliva is collected by placing a cotton roll around in the subject's mouth until it becomes saturated, then the cotton is placed in a collection tube. Next, 1.5 mL of the solution are injected directly into the cotton and the tube is capped for storage at room temperature. The effectiveness of the solution has been demonstrated in tests on specimens of saliva containing herpes simplex virus. In the tests, the viral DNA, as amplified by polymerase chain reaction, was detected even after storage for 120 days.

Pierson, Duane L.↗