Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIZE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

SU-E-T-298: Small Field Total Scatter Factors Using a Commercial Scintillator Detector: Calibration Parameters Are Not Independent of Field Size

Purpose: To evaluate the accuracy in total scatter factor (Sc,p) determination for small fields using commercial plastic scintillator detector (PSD). The manufacturer's spectral discrimination method to subtract Cerenkov light from the signal is discussed. Methods: Sc,p for field sizes ranging from 0.5 to 10 cm were measured using PSD Exradin (Standard Imaging) connected to two channel electrometer measuring the signals in two different spectral regions to subtract the Cerenkov signal from the PSD signal. A Pinpoint ionisation chamber 31006 (PTW) and a non-shielded semiconductor detector EFD (Scanditronix) were used for comparison. Measures were performed for a 6 MV X-ray beam. The Sc,p are measured at 10 cm depth in water for a SSD=100 cm and normalized to a 10'10 cm{sup 2} field size at the isocenter. All detectors were placed with their symmetry axis parallel to the beam axis.We followed the manufacturer's recommended calibration methodology to subtract the Cerenkov contribution to the signal as well as a modified method using smaller field sizes. The Sc,p calculated by using both calibration methodologies were compared. Results: Sc,p measured with the semiconductor and the PinPoint detectors agree, within 1.5%, for field sizes between 10'10 and 1'1 cm{sup 2}. Sc,p measured with the PSD using the manufacturer's calibration methodology were systematically 4% higher than those measured with the semiconductor detector for field sizes smaller than 5'5 cm{sup 2}. By using a modified calibration methodology for smalls fields and keeping the manufacturer calibration methodology for fields larger than 5'5cm{sup 2} field Sc,p matched semiconductor results within 2% field sizes larger than 1.5 cm. Conclusion: The calibration methodology proposed by the manufacturer is not appropriate for dose measurements in small fields. The calibration parameters are not independent of the incident radiation spectrum for this PSD. This work was partially financed by grant 2012 of Barcelona board of the AECC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-454: Impact of Calculation Grid Size On Dosimetry and Radiobiological Parameters for Head and Neck IMRT

Purpose: IMRT has become standard of care for complex treatments to optimize dose to target and spare normal tissues. However, the impact of calculation grid size is not widely known especially dose distribution, tumor control probability (TCP) and normal tissue complication probability (NTCP) which is investigated in this study. Methods: Ten head and neck IMRT patients treated with 6 MV photons were chosen for this study. Using Eclipse TPS, treatment plans were generated for different grid sizes in the range 1–5 mm for the same optimization criterion with specific dose-volume constraints. The dose volume histogram (DVH) was calculated for all IMRT plans and dosimetric data were compared. ICRU-83 dose points such as D2%, D50%, D98%, as well as the homogeneity and conformity indices (HI, CI) were calculated. In addition, TCP and NTCP were calculated from DVH data. Results: The PTV mean dose and TCP decreases with increasing grid size with an average decrease in mean dose by 2% and TCP by 3% respectively. Increasing grid size from 1–5 mm grid size, the average mean dose and NTCP for left parotid was increased by 6.0% and 8.0% respectively. Similar patterns were observed for other OARs such as cochlea, parotids and spinal cord. The HI increases up to 60% and CI decreases on average by 3.5% between 1 and 5 mm grid that resulted in decreased TCP and increased NTCP values. The number of points meeting the gamma criteria of ±3% dose difference and ±3mm DTA was higher with a 1 mm on average (97.2%) than with a 5 mm grid (91.3%). Conclusion: A smaller calculation grid provides superior dosimetry with improved TCP and reduced NTCP values. The effect is more pronounced for smaller OARs. Thus, the smallest possible grid size should be used for accurate dose calculation especially in H and N planning.

60 APPLIED LIFE SCIENCES↗

SU-F-18C-12: On the Relationship of the Weighted Dose to the Surface Dose In Abdominal CT - Patient Size Dependency

Purpose: It is possible to measure the patient surface dose non-invasively using radiolucent dosimeters. However, the patient size specific weighted dose remains unknown. We attempted to study the weighted dose to surface dose relationship as the patient size varies in abdominal CT. Methods: Seven abdomen phantoms (CIRS TE series) simulating patients from an infant to a large adult were used. Size specific doses were measured with a 100 mm CT chamber under axial scans using a Siemens Sensation 64 (mCT) and a GE 750 HD. The scanner settings were 120 kVp, 200 mAs with fully opened collimations. Additional kVps (80, 100, 140) were added depending on the phantom sizes. The ratios (r) of the weighted CT dose (Dw) to the surface dose (Ds) were related to the phantom size (L) defined as the diameter resulting the equivalent cross-sectional area. Results: The Dw versus Ds ratio (r) was fitted to a linear relationship: r = 1.083 − 0.007L (R square = 0.995), and r = 1.064 − 0.007L (R square = 0.953), for Siemens Sensation 64 and GE 750 HD, respectively. The relationship appears to be independent of the scanner specifics. Conclusion: The surface dose to the weighted dose ratio decreases linearly as the patient size increases. The result is independent of the scanner specifics. The result can be used to obtain in vivo CT dosimetry in abdominal CT.

60 APPLIED LIFE SCIENCES↗

TH-C-18A-10: The Influence of Tube Current On X-Ray Focal Spot Size for 70 KV CT Imaging

Purpose: Focal spot blooming is an increase in the focal spot size at increased tube current and/or decreased tube potential. In this work, we evaluated the influence of tube current on the focal spot size at low kV for two CT systems, one of which used a tube designed to reduce blooming effects. Methods: A slit camera (10 micron slit) was used to measure focal spot size on two CT scanners from the same manufacturer (Siemens Somatom Force and Definition Flash) at 70 kV and low, medium and maximum tube currents, according to the capabilities of each system (Force: 100, 800 and 1300 mA; Flash: 100, 200 and 500 mA). Exposures were made with a stationary tube in service mode using a raised stand without table movement or flying focal spot technique. Focal spot size, nominally 0.8 and 1.2 mm, respectively, was measured parallel and perpendicular to the cathode-anode axis by calculating the full-width-at-half-maximum of the slit profile recording using computed radiographic plates. Results: Focal spot sizes perpendicular to the anode-cathode axis increased at the maximum mA by 5.7% on the Force and 39.1% on the Flash relative to that at the minimal mA, even though the mA was increased 13-fold on the Force and only 5- fold on the Flash. Focal spot size increased parallel to the anode-cathode axis by 70.4% on Force and 40.9% on Flash. Conclusion: For CT protocols using low kV, high mA is typically required. These protocols are relevant in children and smaller adults, and for dual-energy scanning. Technical measures to limit focal spot blooming are important in these settings to avoid reduced spatial resolution. The x-ray tube on a recently-introduced scanner appears to greatly reduce blooming effects, even at very high mA values. CHM has research support from Siemens Healthcare.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-CD-209-05: Impact of Spot Size and Spacing On the Quality of Robustly-Optimized Intensity-Modulated Proton Therapy Plans for Lung Cancer

Purpose: To investigate how spot size and spacing affect plan quality, especially, plan robustness and the impact of interplay effect, of robustly-optimized intensity-modulated proton therapy (IMPT) plans for lung cancer. Methods: Two robustly-optimized IMPT plans were created for 10 lung cancer patients: (1) one for a proton beam with in-air energy dependent large spot size at isocenter (σ: 5–15 mm) and spacing (1.53σ); (2) the other for a proton beam with small spot size (σ: 2–6 mm) and spacing (5 mm). Both plans were generated on the average CTs with internal-gross-tumor-volume density overridden to irradiate internal target volume (ITV). The root-mean-square-dose volume histograms (RVH) measured the sensitivity of the dose to uncertainties, and the areas under RVH curves were used to evaluate plan robustness. Dose evaluation software was developed to model time-dependent spot delivery to incorporate interplay effect with randomized starting phases of each field per fraction. Patient anatomy voxels were mapped from phase to phase via deformable image registration to score doses. Dose-volume-histogram indices including ITV coverage, homogeneity, and organs-at-risk (OAR) sparing were compared using Student-t test. Results: Compared to large spots, small spots resulted in significantly better OAR sparing with comparable ITV coverage and homogeneity in the nominal plan. Plan robustness was comparable for ITV and most OARs. With interplay effect considered, significantly better OAR sparing with comparable ITV coverage and homogeneity is observed using smaller spots. Conclusion: Robust optimization with smaller spots significantly improves OAR sparing with comparable plan robustness and similar impact of interplay effect compare to larger spots. Small spot size requires the use of larger number of spots, which gives optimizer more freedom to render a plan more robust. The ratio between spot size and spacing was found to be more relevant to determine plan robustness and the impact of interplay effect than spot size alone. This research was supported by the National Cancer Institute Career Developmental Award K25CA168984, by the Fraternal Order of Eagles Cancer Research Fund Career Development Award, by The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research, by Mayo Arizona State University Seed Grant, and by The Kemper Marley Foundation.

60 APPLIED LIFE SCIENCES↗

Effect of Particle Size on the Dissolution of Pt 3 Co/C and Pt/C PEMFC Electrocatalysts

Potentiostatic and potentiodynamic Pt and Co dissolution were investigated for three Pt 3 Co/C catalysts with particle sizes of 4.9, 8.1, and 14.8 nm in aqueous electrolyte at potentials encountered by the PEMFC cathode. For all three Pt 3 Co/C catalysts under prolonged potentiostatic dissolution, the dissolved Pt steady state concentration increases from 0.85 V to reach a maximum at 1.1−1.15 V and decreases at higher potentials. The dependence of the dissolved Pt steady state concentration on particle size reveals that catalyst stability decreases with decreasing mean particle size, whereas the stability under potential cycling conditions is non-monotonic with particle size. Preferential dissolution of Co from all three Pt 3 Co catalysts was observed at all potentials, which increases at >1.1 V, the region over which Pt dissolution decreases, reflecting the opposing effects of Pt oxide formation on Pt and Co dissolution. Comparison of Pt 3 Co/C and Pt/C with similar mean particle sizes (4.9 vs 5.0 nm) and particle size distributions reveals that the Pt 3 Co/C has a higher potentiostatic dissolution rate (4–5 times), a higher steady state concentration of dissolved Pt (∼2 times), and a larger change in electrochemically-active surface area (ECA) (18 times) after prolonged cycling, indicating that Pt 3 Co has inferior stability. The higher rates of Pt dissolution for Pt 3 Co vs Pt have been attributed to higher extents of surface Pt oxidation, as determined using voltammetric oxide reduction charges and the white line intensities in Pt L 3 X-ray absorption spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Power-Law Scaling in the Internal Variability of Cumulus Cloud Size Distributions due to Subsampling and Spatial Organization

In this study, the spatial structure of cumulus cloud populations is investigated using three-dimensional snapshots from large-domain LES experiments. The aim is to understand and quantify the internal variability in cloud size distributions due to subsampling effects and spatial organization. A set of idealized shallow cumulus cases is selected with varying degrees of spatial organization, including a slowly organizing marine precipitating case and five more quickly organizing diurnal cases over land. A subdomain analysis is applied, yielding cloud number distributions at sample sizes ranging from severely undersampled to nearly complete. A strong power-law scaling is found in the relation between cloud number variability and subdomain size, reflecting an inverse linear relation. Scaling subdomain size by cloud size yields a data collapse across time points and cases, highlighting the role played by cloud spacing in controlling the stochastic variability. Spatial organization acts on top of this baseline model by increasing the maximum cloud size and by enhancing the variability in the number of smallest clouds. This reflects that the smaller clouds start to live on top of larger-scale thermodynamic structures, such as cold pools, which favor or inhibit their formation. Compositing all continental cumulus cases suggests the existence of a prototype diurnal time dependence in the spatial organization. A simple stochastic expression for cloud number variability is proposed that is formulated in terms of two dimensionless groups, which allows objective estimation of the degree of spatial organization in simulated and observed cumulus cloud populations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data for Influence of Particle Size on NIR Spectroscopic Characterization of Sorghum Biomass for the Biofuel Industry

NIR spectroscopy is a rapid and accurate green technology for high-throughput biomass characterization, including sorghum ( Sorghum bicolor ), a promising energy crop for the biofuel industry. This study assessed the influence of particle size on NIR spectroscopic analysis (wavelength range: 867–2535 nm) of sorghum biomass composition. Grown under field conditions, a total of 113 types of genetically diverse sorghum accessions were dried, ground, and sieved (<250, 250–600, 600–850, and > 850 µm particle size) for developing partial least square regression (PLSR) prediction models for moisture, ash, extractive, glucan, xylan, acid-soluble lignin (ASL), acid-insoluble lignin (AIL), and total lignin (ASL + AIL). Overall, smaller particle sizes provided better model performance, while no single particle size provided the best performance for all the selected components. With only 9 selected bands and 4 latent variables (LVs), the best PLSR model was obtained for moisture with particle size of 600–850 µm with the square root of the coefficient of determination (R) of 0.85, the ratio of prediction to deviation (RPD) of 2.2, and the root mean square error (RMSE) of 0.46 % in external validation. Similar model performances were also obtained for ash, extractive, glucan, and xylan. This study showed that size reduction could effectively improve NIR spectroscopic analysis for lipid-producing sorghum biomass for the biofuel industry.

Biomass Analytics↗

Beam Size Measurement by Optical Diffraction Radiation and Laser System for Compton Polarimeter

Beam diagnostics is an essential constituent of any accelerator, so that it is named as "organs of sense" or "eyes of the accelerator." Beam diagnostics is a rich field. A great variety of physical effects or physical principles are made use of in this field. Some devices are based on electro-magnetic influence by moving charges, such as faraday cups, beam transformers, pick-ups; Some are related to Coulomb interaction of charged particles with matter, such as scintillators, viewing screens, ionization chambers; Nuclear or elementary particle physics interactions happen in some other devices, like beam loss monitors, polarimeters, luminosity monitors; Some measure photons emitted by moving charges, such as transition radiation, synchrotron radiation monitors and diffraction radiation-which is the topic of the first part of this thesis; Also, some make use of interaction of particles with photons, such as laser wire and Compton polarimeters-which is the second part of my thesis. Diagnostics let us perceive what properties a beam has and how it behaves in a machine, give us guideline for commissioning, controlling the machine and indispensable parameters vital to physics experiments. In the next two decades, the research highlight will be colliders (TESLA, CLIC, JLC) and fourth-generation light sources (TESLA FEL, LCLS, Spring 8 FEL) based on linear accelerator. These machines require a new generation of accelerator with smaller beam, better stability and greater efficiency. Compared with those existing linear accelerators, the performance of next generation linear accelerator will be doubled in all aspects, such as 10 times smaller horizontal beam size, more than 10 times smaller vertical beam size and a few or more times higher peak power. Furthermore, some special positions in the accelerator have even more stringent requirements, such as the interaction point of colliders and wigglor of free electron lasers. Higher performance of these accelerators increases the difficulty of diagnostics. For most cases, intercepting measurements are no longer acceptable, and nonintercepting method like synchrotron radiation monitor can not be applied to linear accelerators. The development of accelerator technology asks for simutanous diagnostics innovations, to expand the performance of diagnostic tools to meet the requirements of the next generation accelerators. Diffraction radiation and inverse Compton scattering are two of the most promising techniques, their nonintercepting nature avoids perturbance to the beam and damage to the instrumentation. This thesis is divided into two parts, beam size measurement by optical diffraction radiation and Laser system for Compton polarimeter. Diffraction radiation, produced by the interaction between the electric field of charged particles and the target, is related to transition radiation. Even though the theory of diffraction radiation has been discussed since 1960s, there are only a few experimental studies in recent years. The successful beam size measurement by optical diffraction radiation at CEBAF machine is a milestone: First of all, we have successfully demonstrated diffraction radiation as an effective nonintercepting diagnostics; Secondly, the simple linear relationship between the diffraction radiation image size and the actual beam size improves the reliability of ODR measurements; And, we measured the polarized components of diffraction radiation for the first time and I analyzed the contribution from edge radiation to diffraction radiation.

43 PARTICLE ACCELERATORS↗

A margin based approach to determining sample sizes via tolerance bounds.

This paper proposes a tolerance bound approach for determining sample sizes. With this new methodology we begin to think of sample size in the context of uncertainty exceeding margin. As the sample size decreases the uncertainty in the estimate of margin increases. This can be problematic when the margin is small and only a few units are available for testing. In this case there may be a true underlying positive margin to requirements but the uncertainty may be too large to conclude we have sufficient margin to those requirements with a high level of statistical confidence. Therefore, we provide a methodology for choosing a sample size large enough such that an estimated QMU uncertainty based on the tolerance bound approach will be smaller than the estimated margin (assuming there is positive margin). This ensures that the estimated tolerance bound will be within performance requirements and the tolerance ratio will be greater than one, supporting a conclusion that we have sufficient margin to the performance requirements. In addition, this paper explores the relationship between margin, uncertainty, and sample size and provides an approach and recommendations for quantifying risk when sample sizes are limited.

Newcomer, Justin T.↗

Property Improvement in CZT via Modeling and Processing Innovations . Te-particles in vertical gradient freeze CZT: Size and Spatial Distributions and Constitutional Supercooling

A section of a vertical gradient freeze CZT boule approximately 2100-mm 3 with a planar area of 300-mm 2 was prepared and examined using transmitted IR microscopy at various magnifications to determine the three-dimensional spatial and size distributions of Te-particles over large longitudinal and radial length scales. The boule section was approximately 50-mm wide by 60-mm in length by 7-mm thick and was doubly polished for TIR work. Te-particles were imaged through the thickness using extended focal imaging to locate the particles in thickness planes spaced 15-µm apart and then in plane of the image using xy-coordinates of the particle center of mass so that a true three dimensional particle map was assembled for a 1-mm by 45-mm longitudinal strip and for a 1-mm by 50-mm radial strip. Te-particle density distributions were determined as a function of longitudinal and radial positions in these strips, and treating the particles as vertices of a network created a 3D image of the particle spatial distribution. Te-particles exhibited a multi-modal log-normal size density distribution that indicated a slight preference for increasing size with longitudinal growth time, while showing a pronounced cellular network structure throughout the boule that can be correlated to dislocation network sizes in CZT. Higher magnification images revealed a typical Rayleigh-instability pearl string morphology with large and small satellite droplets. This study includes solidification experiments in small crucibles of 30:70 mixtures of Cd:Te to reduce the melting point below 1273 K (1000°C). These solidification experiments were performed over a wide range of cooling rates and clearly demonstrated a growth instability with Te-particle capture that is suggested to be responsible for one of the peaks in the size distribution using size discrimination visualization. The results are discussed with regard to a manifold Te-particle genesis history as 1) Te-particle direct capture from melt-solid growth instabilities, 2) Te-particle formation from dislocation core diffusion and the formation and breakup of Te-tubes, and 3) Te-particle formation due to classical nucleation and growth as precipitates.

36 MATERIALS SCIENCE↗

Tagging a smaller size class of fish: can it be done?

There is a new acoustic transmitter that is smaller than anything on the market and can be used to tag smaller fish than ever before. It is called the Eel-Lamprey Acoustic Tag (ELAT). Although the technology is ready to use, we cannot deploy it in the field until the biological proof of concept is tested in the lab. As such, we conducted two laboratory studies to evaluate the tag effects of surgical implantation in small (30–95 mm fork length [FL]) fry and smolt sized juvenile salmon. The first study was a survival, transmitter retention, and growth holding study and the second was a swimming performance study. Our goal was to identify a minimum size threshold for Chinook Salmon that can be implanted with an ELAT where survival, ELAT retention, growth, and swimming performance would not be affected compared to an untagged population. In the survival and growth study, fish were held for 50 days. At the end of the study we found that fish as small as 55 mm FL had a 95% survival rate. There was no difference in growth between tagged and untagged fish. The swimming performance study identified a minimum size threshold of 51 mm FL. This indicated the swimming performance of a tagged fish was not different from an untagged fish once the fish was 51 mm or longer. Using the results from the two laboratory studies, 55 mm FL was identified as a minimum size threshold where growth, survival, ELAT retention, and swimming performance were not affected compared to untagged fish. This research confirmed we can tag a smaller size class of fish and provided a minimum size threshold for use in tagging guidelines.

42 ENGINEERING↗

Artifacts in the Aerosol Size Distribution Measured by the Ultra-High-Sensitivity Aerosol Spectrometer (UHSAS)

The ultra-high-sensitivity aerosol spectrometer (UHSAS) (Droplet Measurement Technologies, Longmont, Colorado) is an optical particle size spectrometer that determines aerosol size distributions in the diameter range from 60 to 1000 nm in 100 logarithmically spaced diameter bins1 by measuring the amount of light scattered by individual aerosol particles from a 1054-nm laser. Recently, it was noticed that aerosol size distributions determined by the UHSAS from all U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility sites exhibited modes at diameters greater than ~500 nm (Figure 1, blue arrows). These modes were not present in size distributions determined by another aerosol spectrometer that was co-located with the UHSAS, the Grimm 11D optical particle counter (OPC) (GRIMM Aerosol Technik Ainring GmbH & Co. KG, Germany), which sizes particles into 31 linearly spaced diameters bins from 253 to 35,150 nm using a 683-nm wavelength laser. Additionally, abrupt changes in aerosol particle number concentration with changing particle diameter are seen in UHSAS data at several diameters (Figure 1, red arrows). The purpose of this report is to explain the origin of the modes and the abrupt changes in aerosol size distributions observed by the UHSAS and why they are absent in the data from the Grimm OPC.

54 ENVIRONMENTAL SCIENCES↗

The Sizes of z ∼ 9−10 Galaxies Identified in the Brightest of Reionizing Galaxies (BoRG) Survey

Redshift z = 9–10 object selection is the effective limit of Hubble Space Telescope (HST) imaging capability, even when confirmed with Spitzer. If only a few photometry data points are available, it becomes attractive to add criteria based on their morphology in these J- and H-band images. One could do so through visual inspection, a size criterion, or alternate morphometrics. We explore a vetted sample of Brightest of Reionizing Galaxies (BoRG) z ∼ 9 and z ∼ 10 candidate galaxies and the object rejected by Morishita+ to explore the utility of a size criterion in z = 9–10 candidate selection. A stringent, point-spread function (PSF)-corrected effective radius criterion ([[Formula]]) would result in the rejection of 65%–70% of the interlopers visually rejected by Morishita et al. It may also remove up to ∼20% of bona fide brightest (L≫L{sup ∗}) z = 9 or 10 candidates from a BoRG selected sample based on the Mason et al. luminosity functions, assuming the Holwerda et al. z∼9 size–luminosity relation. We argue that including a size constraint in lieu of a visual inspection may serve in wide-field searches for these objects in, e.g., Euclid or HST archival imaging with the understanding that some brightest (L≫L{sup ∗}) candidates may be missed. The sizes of the candidates found by Morishita et al. follow the expected size distribution of z ∼ 9 for bright galaxies, consistent with the log normal in Shibuya et al. and single objects. Two candidates show high star formation surface density (Σ{sub SFR}>25M{sub ⊙} kpc{sup −2}) and all merit further investigation and follow-up observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Quasar Accretion Disk Sizes from Continuum Reverberation Mapping from the Dark Energy Survey

We present accretion disk size measurements for 15 luminous quasars at 0.7 ≤ z ≤ 1.9 derived from griz light curves from the Dark Energy Survey. We measure the disk sizes with continuum reverberation mapping using two methods, both of which are derived from the expectation that accretion disks have a radial temperature gradient and the continuum emission at a given radius is well described by a single blackbody. Here in the first method we measure the relative lags between the multiband light curves, which provides the relative time lag between shorter and longer wavelength variations. From this, we are only able to constrain upper limits on disk sizes, as many are consistent with no lag the 2σ level. The second method fits the model parameters for the canonical thin disk directly rather than solving for the individual time lags between the light curves. Our measurements demonstrate good agreement with the sizes predicted by this model for accretion rates between 0.3 and 1 times the Eddington rate. Given our large uncertainties, our measurements are also consistent with disk size measurements from gravitational microlensing studies of strongly lensed quasars, as well as other photometric reverberation mapping results, that find disk sizes that are a factor of a few (~3) larger than predictions.

79 ASTRONOMY AND ASTROPHYSICS↗

The SAGA Survey. VI. The Size–Mass Relation for Low-mass Galaxies Across Environments

We investigate how Milky Way (MW)–like environments influence the sizes and structural properties of low mass galaxies by comparing satellites of MW analogs from the Satellites Around Galactic Analogs (SAGA) Survey with two control samples: an environmentally agnostic population from the SAGA background sample and isolated galaxies from the Sloan Digital Sky Survey NASA-Sloan Atlas. All sizes and structural parameters are measured uniformly using pysersic to ensure consistency across samples. We find the half-light sizes of SAGA satellites are systematically larger than those of isolated galaxies, with the magnitude of the offset ranging from 0.05 to 0.12 dex (10%–24%) depending on the comparison sample and completeness cuts. This corresponds to physical size differences between 85 and 200 pc at log 10 (M$_{{\star}}$/M ⊙ ) = 7.5 and 220–960 pc at log 10 (M$_{{\star}}$/M ⊙ ) = 10. This offset persists among star-forming galaxies, suggesting that environment can influence the structure of low-mass galaxies even before it impacts quenching. The intrinsic scatter in the size–mass relation is lower for SAGA satellites than isolated galaxies, and the Sérsic index distributions of satellites and isolated galaxies are similar. In comparison to star-forming satellites, quenched SAGA satellites have a slightly shallower size–mass relation and rounder morphologies at low mass, suggesting that quenching is accompanied by structural transformation and that the processes responsible differ between low- and high-mass satellites. Our results show that environmental processes can imprint measurable structural differences on satellites in MW-mass halos.

Asali, Yasmeen [Yale Univ., New Haven, CT (United ↗

Dependence of Narrow-line Region Sizes on [O III ] Luminosity in Low-redshift Active Galactic Nuclei with Double-peaked Broad Balmer Emission Lines

In this paper, simple but interesting results are reported on the upper limits of narrow-line region (NLR) sizes of a small sample of 38 low-redshift (z < 0.1) active galactic nuclei (AGN) with double-peaked broad emission lines (double-peaked BLAGN), in order to check whether the NLR sizes in type-1 AGN (broad line) and type-2 AGN (narrow line) obey a similar empirical dependence on [O III ] luminosity. In order to correct the inclination effects on projected NLR sizes of type-1 AGN, the accretion disk origin is commonly applied to describe the double-peaked broad Hα line, leading to the determined inclination angles of central disk-like broad-line regions of 38 double-peaked BLAGN. Then, considering the fixed Sloan Digital Sky Survey (SDSS) fiber radius, the upper limits of the NLR sizes of the 38 double-peaked BLAGN can be estimated. Meanwhile, a strong linear correlation between continuum luminosity and [O III ] luminosity is applied to confirm that the [O III ] emissions of the 38 double-peaked BLAGN are totally covered in the SDSS fibers. Considering the reddening-corrected measured [O III ] luminosity, the upper limits of the NLR sizes of the 38 double-peaked BLAGN are within a 99.9999% confidence interval of the expected results from the empirical relation between NLR size and [O III ] luminosity in type-2 AGN. In the current understanding, there are no challenges to the unified model of AGN through the space properties of NLRs.

79 ASTRONOMY AND ASTROPHYSICS↗

Size dependent lattice pseudosymmetry for frustrated decahedral nanoparticles

Geometric frustration—where geometry prevents simultaneous satisfaction of local interactions—generates pseudosymmetry and emergent behaviors across physical and biological systems. At the nanoscale, pseudosymmetric features in crystalline materials manifest as local strain and distortion, but how they depend on particle size and control structural stability remains unclear. Here, we report the first study of a size-dependent crossover in pseudosymmetry in multi-twinned gold nanoparticles (NPs), combining four-dimensional scanning transmission electron microscopy with nanoscale strain mapping grounded in continuum solid mechanics. Analysis of more than 20 decahedral NPs (20–55 nm) reveals pronounced heterogeneity in multiple modes of in-plane strain and displacement field in small NPs as five tetrahedral grains close the geometric gap, without extended defects. With increasing particle size, strain fields homogenize across grains and local phases shift from predominantly low-symmetry body-centered tetragonal motifs at small sizes to face-centered cubic character approaching the bulk limit. We identify a crossover particle size of ~35 nm, well below bulk, correlating with a transition from modified-Wulff shapes to pentagonal bipyramids, consistent with finite element predictions. This quantitative framework for mapping size-dependent strain and pseudosymmetry enables precise design and control of functional crystalline solids and phase transformation for catalysis, photonics, electronics, and energy storage.

Lin, Oliver [University of Illinois at Urbana-Cham↗