Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SINGLE IONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

Strain engineering 4H-SiC with ion beams

Single crystals of 4H-SiC irradiated with 900 keV Si and 21 MeV Ni ions separately and sequentially were examined by Rutherford backscattering spectrometry in channeling geometry, single crystal X-ray diffraction, and Raman scattering. SiC irradiated with 900 keV Si ions to a fluence of 6.3 × 10 14 ions/cm 2 experiences 7.3% strain over the depth of 650 nm. Strain relaxation from ionization-induced annealing was directly studied due to subsequent irradiation with 21 MeV Ni ions to a fluence of 2 × 10 14 ions/cm 2 . These competitive processes suggest the use of ion irradiation to create a specific strain state in 4H-SiC, particularly in films.

36 MATERIALS SCIENCE↗

Progress of the laser ion source upgrade (LION2) for RHIC and NSRL program at Brookhaven National Laboratory

At Brookhaven National Laboratory (BNL), the LION2 ion source is being constructed to replace an existing laser ion ablation ion source (LIS) at the EBIS facility, which provides heavy ion beams of multiple ion species for the operation of NASA Space Radiation Laboratory (NSRL) and Relativistic Heavy Ion Collider (RHIC). The LION1 ion source currently provides singly charged ions of Li, B, C, O, Al, Si, Ca, Ti, Fe, Cu, Zr, Nb, Ag, Tb, Ta, W, Au, Bi, and Th with a rapid-species-change capability. An electron beam ion source, Extended-EBIS captures, confines, and ionizes the ions to high charge state, suitable for injection and acceleration by an RFQ accelerator. Typically, single pulses of the LIS ion species for NSRL are changed sequentially during Galactic Cosmic Ray experiments, while multiple pulses of a given ion beam are provided quasi-simultaneously for RHIC. LION2 will have the same capability of the rapid-species-change with improved beam performance and reliability. LION2 is being constructed in a remote assembly location and is expected to finish in December 2023. The removal of LION1 and installation of LION2 is planned during the December 2023 or summer 2024 shutdown.

43 PARTICLE ACCELERATORS↗

Measurement of Doubly Charged Ions in Ion Thruster Plumes

The ratio of doubly to singly charged ions was measured in the plumes of a 30 cm and of a 40 cm ion thruster. The measured ratio was correlated with observed erosion rates and thruster operating conditions. The measured and calculated erosion rates paralleled variation in the j(sup ++)/j(sup +) ratio and indicated that the erosion was dominated by Xe III. Simple models of cathode potential surfaces which were developed in support of this work were in agreement with this conclusion and provided a predictive capability of the erosion given the ratio of doubly to singly charged ion currents.

Williams, George J., Jr.↗

Trapping of Intact, Singly-Charged, Bovine Serum Albumin Ions Injected from the Atmosphere with a 10-cm Diameter, Frequency-Adjusted Linear Quadrupole Ion Trap

High-resolution real-time particle mass measurements have not been achievable because the enormous amount of kinetic energy imparted to the particles upon expansion into vacuum competes with and overwhelms the forces applied to the charged particles within the mass spectrometer. It is possible to reduce the kinetic energy of a collimated particulate ion beam through collisions with a buffer gas while radially constraining their motion using a quadrupole guide or trap over a limited mass range. Controlling the pressure drop of the final expansion into a quadrupole trap permits a much broader mass range at the cost of sacrificing collimation. To achieve high-resolution mass analysis of massive particulate ions, an efficient trap with a large tolerance for radial divergence of the injected ions was developed that permits trapping a large range of ions for on-demand injection into an awaiting mass analyzer. The design specifications required that frequency of the trapping potential be adjustable to cover a large mass range and the trap radius be increased to increase the tolerance to divergent ion injection. The large-radius linear quadrupole ion trap was demonstrated by trapping singly-charged bovine serum albumin ions for on-demand injection into a mass analyzer. Additionally, this work demonstrates the ability to measure an electrophoretic mobility cross section (or ion mobility) of singly-charged intact proteins in the low-pressure regime. This work represents a large step toward the goal of high-resolution analysis of intact proteins, RNA, DNA, and viruses.

59 BASIC BIOLOGICAL SCIENCES↗

161 Dy Time-Domain Synchrotron Mössbauer Spectroscopy for Investigating Single-Molecule Magnets Incorporating Dy Ions [ 161 Dy time-domain synchrotron Mössbauer spectroscopy as a new way forward for investigating single molecule magnets incorporating Dy ions]

Time–domain synchrotron Mössbauer spectroscopy (SMS) based on the Mössbauer effect of 161 Dy has been used to investigate the magnetic properties of a Dy III –based single–molecule magnet (SMM). The magnetic hyperfine field of [Dy(Cy 3 PO) 2 (H 2 O) 5 ]Br 3 •2 (Cy 3 PO)•2 H 2 O•2 EtOH is with B 0 =582.3(5) T significantly larger than that of the free–ion Dy III with a 6 H 15/2 ground state. This difference is attributed to the influence of the coordinating ligands on the Fermi contact interaction between the s and 4f electrons of the Dy III ion. Furthermore this study demonstrates that 161 Dy SMS is an effective local probe of the influence of the coordinating ligands on the magnetic structure of Dy–containing compounds.

74 ATOMIC AND MOLECULAR PHYSICS↗

A detailed study of collisionless explosion of single- and two-ion-species spherical nanoplasmas

The collisionless adiabatic expansion into vacuum of spherical plasma targets (clusters) composed of cold single- or multispecies ions and hot electrons is studied kinetically by numerical solving of the nonrelativistic equations of motion of plasma particles in the self-consistent electrostatic field. The expansion dynamics for the whole range of electron temperatures from much less than to much higher than the cluster Coulomb energy is described for various initial plasma density profiles and cluster structures. The explosion of two ion species heterogeneous (layered) and homogeneously mixed targets is studied in detail for the wide range of light ion concentration and kinematic parameter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Propagation of Surface Ripples on Pyrochlore Single Crystals Induced by Ion Beam Bombardment

The morphological evolution of ripples formed on the surface of Cd2Nb2O7 pyrochlore single crystals by focused ion beam (FIB) bombardment was investigated using in situ electron microscopy. At high ion fluences and off-normal bombardment angles, faceted surface ripples with a terrace-like structure were observed. The ripple propagation direction was oriented along the projected ion beam direction at incident angles ranging from 35 to 65 following high-dose ion bombardment. One side of the terrace was found to be perpendicular to the incident ion beam direction, while the other side was parallel to the ion beam. The terrace propagation velocity and direction were determined and interpreted on the basis of this asymmetric structure. A model based on the propagation of a shock wave that effectively self-selects a stable slope, was developed in order to explain the observed faceted ripple formation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Heavy Ion and Proton Induced Single Event Transients in Linear Devices

This paper presents a display of heavy-ion and proton-induced single event transients for selected linear devices. The transient vital signs are serious; low LET threshold, high voltage amplitude and extended pulse duration (microsecs.).

heavy ions ions transients linear devices LET thre↗

Barium Chemosensors with Dry-Phase Fluorescence for Neutrinoless Double Beta Decay

The nature of the neutrino is one of the major open questions in experimental nuclear and particle physics. The most sensitive known method to establish the Majorana nature of the neutrino is detection of the ultra-rare process of neutrinoless double beta decay. However, identification of one or a handful of decay events within a large mass of candidate isotope, without obfuscation by backgrounds is a formidable experimental challenge. One hypothetical method for achieving ultra- low-background neutrinoless double beta decay sensitivity is the detection of single 136 Ba ions produced in the decay of 136 Xe (“barium tagging”). To implement such a method, a single-ion-sensitive barium detector must be developed and demonstrated in bulk liquid or dry gaseous xenon. This paper reports on the development of two families of dry-phase barium chemosensor molecules for use in high pressure xenon gas detectors, synthesized specifically for this purpose. One particularly promising candidate, an anthracene substituted aza-18-crown-6 ether, is shown to respond in the dry phase with almost no intrinsic background from the unchelated state, and to be amenable to barium sensing through fluorescence microscopy. This interdisciplinary advance, paired with earlier work demonstrating sensitivity to single barium ions in solution, opens a new path toward single ion detection in high pressure xenon gas.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optima XE Single Wafer High Energy Ion Implanter

The Optima XE is the first production worthy single wafer high energy implanter. The new system combines a state-of-art single wafer endstation capable of throughputs in excess of 400 wafers/hour with a production-proven RF linear accelerator technology. Axcelis has been evolving and refining RF Linac technology since the introduction of the NV1000 in 1986. The Optima XE provides production worthy beam currents up to energies of 1.2 MeV for P{sup +}, 2.9 MeV for P{sup ++}, and 1.5 MeV for B{sup +}. Energies as low as 10 keV and tilt angles as high as 45 degrees are also available., allowing the implanter to be used for a wide variety of traditional medium current implants to ensure high equipment utilization. The single wafer endstation provides precise implant angle control across wafer and wafer to wafer. In addition, Optima XE's unique dose control system allows compensation of photoresist outgassing effects without relying on traditional pressure-based methods. We describe the specific features, angle control and dosimetry of the Optima XE and their applications in addressing the ever-tightening demands for more precise process controls and higher productivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-situ mid-circuit qubit measurement and reset in a single-species trapped-ion quantum computing system

We implement in-situ mid-circuit measurement and reset (MCMR) operations on a trapped-ion quantum computing system by using metastable qubit states in $^{171}\textrm{Yb}^+$ ions. We introduce and compare two methods for isolating data qubits from measured qubits: one shelves the data qubit into the metastable state and the other drives the measured qubit to the metastable state without disturbing the other qubits. We experimentally demonstrate both methods on a crystal of two $^{171}\textrm{Yb}^+$ ions using both the $S_{1/2}$ ground state hyperfine clock qubit and the $S_{1/2}$-$D_{3/2}$ optical qubit. These MCMR methods result in errors on the data qubit of about $2\%$ without degrading the measurement fidelity. With straightforward reductions in laser noise, these errors can be suppressed to less than $0.1\%$. The demonstrated method allows MCMR to be performed in a single-species ion chain without shuttling or additional qubit-addressing optics, greatly simplifying the architecture.

Atomic Physics (physics.atom-ph)↗

In situ midcircuit qubit measurement and reset in a single-species trapped-ion quantum computing system

We implement in situ midcircuit measurement and reset (MCMR) operations on a full-scale trapped-ion quantum computing system by using metastable qubit states in 171 Yb + ions. We compare two methods for isolating data qubits from measured qubits: one shelves the data qubits into the metastable state and the other drives the measured qubit to the metastable state without disturbing the other qubits. We experimentally demonstrate both methods on a crystal of two 171 Yb + ions using both the 𝑆 1/2 ground-state hyperfine clock qubit and the 𝑆 1/2 −𝐷 3/2 optical qubit. These MCMR methods result in errors on the data qubit of about 2% without degrading the measurement fidelity. With straightforward reductions in laser noise, these errors can be suppressed to less than 0.1%. The demonstrated methods allow MCMR to be performed in a single-species ion chain without shuttling or additional qubit-addressing optics, greatly simplifying the system architecture and allowing straightforward integration with existing trapped-ion quantum computers.

coherent control↗