Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCINTILLATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

FInal Report: First Principles Modeling of Mechanisms Underlying Scintillator Non-Proportionality

This final report presents work carried out on the project “First Principles Modeling of Mechanisms Underlying Scintillator Non-Proportionality” at Lawrence Livermore National Laboratory during 2013-2015. The scope of the work was to further the physical understanding of the microscopic mechanisms behind scintillator nonproportionality that effectively limits the achievable detector resolution. Thereby, crucial quantitative data for these processes as input to large-scale simulation codes has been provided. In particular, this project was divided into three tasks: (i) Quantum mechanical rates of non-radiative quenching, (ii) The thermodynamics of point defects and dopants, and (iii) Formation and migration of self-trapped polarons. The progress and results of each of these subtasks are detailed.

36 MATERIALS SCIENCE↗

Current status on plastic scintillators modifications

Recent developments of plastic scintillators are reviewed, from 2000 to March 2015. All examples are distributed into the main purpose, i.e. the nature of the radionuclide provided with the scope of detection of various radiation particles. The main characteristics of these newly created scintillators and their detection properties are given. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emergence of Uranium as a Distinct Metal Center for Building Intrinsic X-ray Scintillators

The combination of high atomic number and high oxidation state in U VI materials gives rise to both high X-ray attenuation efficiency and intense green luminescence originating from ligand-to-metal charge transfer. These two features suggest that U VI materials might act as superior X-ray scintillators, but this postulate has remained substantially untested. Now the first observation of intense X-ray scintillation in a uranyl–organic framework (SCU-9) that is observable by the naked eye is reported. Combining the advantage in minimizing the non-radiative relaxation during the X-ray excitation process over those of inorganic salts of uranium, SCU-9 exhibits a very efficient X-ray to green light luminescence conversion. The luminescence intensity shows an essentially linear correlation with the received X-ray intensity, and is comparable with that of commercially available CsI:Tl. SCU-9 possesses an improved X-ray attenuation efficiency (E>20 keV) as well as enhanced radiation resistance and decreased hygroscopy compared to CsI:Tl.

Chemistry↗

Crystal growth and characterization of high performance KSr 2 Br x I 5-x :Eu scintillators

In this work we investigated the effects of replacing some of the matrix iodine atoms in KSr 2 I 5 :Eu with bromine, forming new solid solutions of KSr 2 Br x I (5-x) :Eu (where 0.05 ≤ x ≤ 1). Transparent 15 and 22mm diameter single crystals of KSr 2 Br x I (5-x) :Eu were grown via the vertical Bridgman technique using a two-zone transparent furnace. The scintillation properties of the mixed compounds were investigated and compared to the non-mixed parent compound, KSr 2 I 5 :Eu. The addition of bromine blue-shifted the x-ray excited emission from 450 to 446 nm, increased the light yield by ~11% and decreased the scintillation decay time by suppressing its secondary component (≥3 μs), while maintaining energy resolutions comparable to the reference crystal. Thermoluminescence glow curves showed that the addition of bromine modified the shallow traps located between 25 and 55 K, suggesting that these traps are responsible for lengthening KSI’s decay time. In large sizes (10.3 cm 3 ), KSr 2 Br 0.10 I 4.90 :Eu 2% had light yields up to 79,000 ph/MeV and energy resolutions as low as 3.2% at 662 keV.

36 MATERIALS SCIENCE↗

Europium concentration effects on the scintillation properties of Cs 4 SrI 6 :Eu and Cs 4 CaI 6 :Eu single crystals for use in gamma spectroscopy

Recently discovered scintillators Cs 4 SrI 6 :Eu and Cs 4 CaI 6 :Eu have shown promising properties for gamma-ray detection in homeland security applications, with <4% energy resolution (at 662 keV) and light yields above 50,000 ph/MeV. However, a thorough investigation of the effects of europium concentration has not yet been conducted. In this work, Eu 2+ concentration was varied from 0.5 mol% to 9 mol%, and Ø7 mm single crystals were grown from the melt via the vertical Bridgman method. Scintillation performance was evaluated as a function of Eu 2+ concentration to determine the optimal amount. The observed trend was improved energy resolution and higher light yield with increasing Eu 2+ concentration up to 7 mol%. The best energy resolution achieved was 3.2% for Cs 4 SrI 6 :Eu 7% and 3.6% for Cs 4 CaI 6 :Eu 7%. Their respective light yields were 71,000 ph/MeV and 69,000 ph/MeV.

36 MATERIALS SCIENCE↗

Scintillation, dosimeter and optical properties of MgF2 transparent ceramics doped with Gd3+

Highlights: • We have developed MgF{sub 2}:Gd{sup 3+} transparent ceramics by SPS. • The samples showed luminescence due to the 4f-4f transitions of Gd{sup 3+}. • The 1% Gd-doped sample has high TSL sensitivity equivalent to commercial personal dosimeters. - Abstract: In this study, we have developed MgF{sub 2}:Gd transparent ceramics by spark plasma sintering (SPS) and evaluated the scintillation, dosimeter and optical properties. All the sample were successfully synthesized in a transparent form with relative densities over 99% to that of the single crystal. The samples were confirmed to show scintillation, thermally-stimulated luminescence (TSL) and optically-stimulated luminescence (OSL). The origin of these emissions was due to the 4f-4f transitions of Gd{sup 3+} appearing as a single peak at 310 nm. In particular, the TSL was very sensitive to X-rays, and especially the 1% Gd-doped sample showed a sensitivity as low as 0.1 mGy. The TSL response increases monotonically with the irradiation dose, and the dynamic range was confirmed to be over 0.1–1000 mGy, which was equivalent sensitivity to that of commercial personal dosimeters.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimization of crystal growth and properties of γ-CuI ultrafast scintillator by the addition of LiI

Highlights: • Large and transparent γ-CuI single crystal with the size over 20 mm was successfully obtained for the first time. • The intensities of near-band-edge emissions of γ-CuI single crystal are greatly enhanced by Li and I dopants. • The 430 nm emission decay time is less than 450 ps under pulsed X-ray irradiation. - Abstract: Large-sized γ-CuI single crystals with ultrafast scintillation property were grown in LiI acetonitrile solvent through evaporation technique. The LiI exhibits unique properties to γ-CuI single crystal preparation. One is that it increases the solubility of CuI in the solvent, which gives rise to a largest-sized (23 × 14 × 2 mm{sup 3}) single crystal with the high optical transmission (over 60%) in the wavelength region of 435–800 nm. The other feature is that it acts as an effective isoelectronic dopant and improves the molar ratio of copper to iodine, which greatly enhances the near-band-edge emissions (411 and 432 nm) and suppresses the broadband emission (680 nm). The decay time of the fast emission under pulsed X-ray excitation is shorter than 450 ps. The results will give a guidance for optimizing the properties of γ-CuI single crystal as an ultrafast scintillator.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Comparison of Performance Between Organic Scintillation Crystals and Moderated (3)He-Based Detectors for Fission Neutron Detection

Direct detection of fast neutrons using organic scintillators is one alternative to moderated thermal neutron detectors deployed to detect fission neutrons - a relevant question in light of dwindling {sup 3}He supplies. Recent developments in materials science have demonstrated the capability to grow larger crystals in reasonable times. In light of these developments, this study compares the relative performance of a {sup 3}He-based neutron module from a commercially available portal monitor with a theoretical organic scintillator of similar overall size. Stilbene serves as a benchmark with its performance estimated from a combination of energy deposition modeled by radiation transport calculations and an assumption of the lowest neutron energy at which pulse shape discrimination can effectively separate neutron and gamma-ray events. Before intrinsic detection efficiencies on par with moderated detector systems can be achieved, the results point to the need for further advances including significant increases in detector size, especially thickness, and/or lower pulse shape discrimination thresholds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Plutonium metal vs. oxide determination with the pulse-shape-discrimination-capable plastic scintillator EJ-299-33

Neutron measurements can be used to distinguish plutonium in metal or oxide form, a capability that is of great interest in nuclear nonproliferation, treaty verification, and other applications. This paper describes measurements performed on well-characterized samples of plutonium oxide and plutonium metal using the pulse-shape-discrimination-capable plastic scintillator EJ-299-33. Results are compared to those obtained with a same-sized detector cell using the liquid scintillator EJ-309. The same optimized, digital pulse shape discrimination technique is applied to both detectors and the neutron pulse height distributions are compared. Results show that the EJ-299-33 plastics can be successfully used for plutonium measurements, where the gamma ray to neutron detection ratio is much higher than for typical radioactive sources. Results also show that EJ-299-33 detectors can be used to characterize plutonium samples, specifically to discriminate between plutonium metal and oxide.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An algorithm for charge-integration, pulse-shape discrimination and estimation of neutron/photon misclassification in organic scintillators

Organic scintillators are frequently used for measurements that require sensitivity to both photons and fast neutrons because of their pulse shape discrimination capabilities. In these measurement scenarios, particle identification is commonly handled using the charge-integration pulse shape discrimination method. This method works particularly well for high-energy depositions, but is prone to misclassification for relatively low-energy depositions. A novel algorithm has been developed for automatically performing charge-integration pulse shape discrimination in a consistent and repeatable manner. The algorithm is able to estimate the photon and neutron misclassification corresponding to the calculated discrimination parameters, and is capable of doing so using only the information measured by a single organic scintillator. This paper describes the algorithm and assesses its performance by comparing algorithm-estimated misclassification to values computed via a more traditional time-of-flight estimation. A single data set was processed using four different low-energy thresholds: 40, 60, 90, and 120 keVee. Overall, the results compared well between the two methods; in most cases, the algorithm-estimated values fell within the uncertainties of the TOF-estimated values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Transparent plastic scintillators for neutron detection based on lithium salicylate

Transparent plastic scintillators with pulse shape discrimination containing 6 Li salicylate have been synthesized by bulk polymerization with a maximum 6 Li loading of 0.40 wt%. Photoluminescence and scintillation responses to gamma-rays and neutrons are reported in this paper. Plastics containing 6 Li salicylate exhibit higher light yields and permit a higher loading of 6 Li as compared to previously reported plastics based on lithium 3-phenylsalicylate. However, pulse shape discrimination performance is reduced in lithium salicylate plastics due to the requirement of adding more nonaromatic monomers to the polymer matrix as compared to those based on lithium 3-phenylsalicylate. Finally, reduction in light yield and pulse shape discrimination performance in lithium-loaded plastics as compared to pulse shape discrimination plastics without lithium is interpreted in terms of energy transfer interference by the aromatic lithium salts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of neutron light output response functions in EJ-309 organic scintillators

An accurate model of the nonlinear detector response of organic scintillators to neutrons is required to correctly simulate fast neutron detection, as well as interpret measured pulse height data. Several empirical and semi-empirical models are available to fit measured scintillator light output data. In this work, EJ-309 light output data from neutrons depositing 1.15–5.15 MeV on hydrogen were analyzed using empirical models as well as semi-empirical models based on the work of Birks and Voltz. Although all tested models fit the experimental light output data well in the measured range, the models were observed to diverge in low-energy extrapolation. The models were then tested by comparing a measurement and MCNPX-PoliMi simulation of an EJ-309 detector response to fast neutrons from a 252 Cf spontaneous fission source. The agreement between the measured and simulated pulse height distributions varied significantly depending on the light output model used. The best agreement between simulated and measured neutron pulse height distributions was achieved by using the Birks model. The bin-by-bin agreement was better than 5% over the range 0.08–2.18 MeVee, and better than 10% from 2.18 to 3.13 MeVee. Furthermore, the integral count rate over the range 0.08–3.14 MeVee differed by less than 1% in absolute units.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radionuclide identification algorithm for organic scintillator-based radiation portal monitor

We have developed an algorithm for on-the-fly radionuclide identification for radiation portal monitors using organic scintillation detectors. The algorithm was demonstrated on experimental data acquired with our pedestrian portal monitor on moving special nuclear material and industrial sources at a purpose-built radiation portal monitor testing facility. The experimental data also included common medical isotopes. The algorithm takes the power spectral density of the cumulative distribution function of the measured pulse height distributions and matches these to reference spectra using a spectral angle mapper. F-score analysis showed that the new algorithm exhibited significant performance improvements over previously implemented radionuclide identification algorithms for organic scintillators. Reliable on-the-fly radionuclide identification would help portal monitor operators more effectively screen out the hundreds of thousands of nuisance alarms they encounter annually due to recent nuclear-medicine patients and cargo containing naturally occurring radioactive material. Lastly, portal monitor operators could instead focus on the rare but potentially high impact incidents of nuclear and radiological material smuggling detection for which portal monitors are intended.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Construction and response of a highly granular scintillator-based electromagnetic calorimeter

Here, a highly granular electromagnetic calorimeter with scintillator strip readout is being developed for future linear collider experiments. A prototype of 21.5 X 0 depth and 180 × 180 mm 2 transverse dimensions was constructed, consisting of 2160 individually read out 10 × 45 × 3 mm 3 scintillator strips. This prototype was tested using electrons of 2–32 Ge V at the Fermilab Test Beam Facility in 2009. Deviations from linear energy response were less than 1.1%, and the intrinsic energy resolution was determined to be ( 12 . 5 ± 0 . 1 ( stat. ) ± 0 . 4 ( syst. ) ) % / E [ Ge V ] ⊕ ( 1 . 2 ± 0 . 1 ( stat. ) - 0 . 7 + 0 . 6 ( syst. ) ) % , where the uncertainties correspond to statistical and systematic sources, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predictive model of scintillator plastic fogging in portals

We have developed a science-based predictive model for fogging of the scintillator plastics deployed in radiation portal monitors. The only input required is the weather conditions [i.e., daily high and low, for temperature and relative humidity (R.H.)]. The code utilizes this information, together with a thermodynamic model of the water content in equilibrium with the plastic surface, a diffusion model of the water transport into the interior of scintillator plastic panel, and a comparison of the resulting paired “water-content/night-temperature” points as a function of position in the panel against an empirical “fog-line” that establishes a water/temperature criterion for the onset of fogging. In conclusion, we have analyzed the behavior of several representative portal monitor sites, and the output of the model analysis is reasonably consistent with observation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving light yield measurements for low-yield scintillators

Light power spectra are introduced as a new tool for relative light yield (LY) determinations. Light event spectra have commonly been used for this purpose. Theoretical background supporting this change is provided. It is shown that the derivative of a light power spectrum can provide a reliable LY measurement at levels as low as 2% of those for high-yield liquid scintillators. In this work, applications to light evolution in the PPO+LAB system and to water-based liquid scintillators are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A helical-shape scintillating fiber trigger and tracker system for the DarkLight experiment and beyond

The search for new physics beyond the Standard Model has interesting possibilities at low energies. For example, the recent 6.8σ anomaly reported in the invariant mass of e + e - pairs from 8 Be nuclear transitions and the discrepancy between predicted and measured values of muon g-2 give strong motivations for a protophobic fifth-force model. At low energies, the electromagnetic interaction is well understood and produces straightforward final states, making it an excellent probe of such models. However, to achieve the required precision, an experiment must address the substantially higher rate of electromagnetic backgrounds. Here in this paper, we present the results of simulation studies of a trigger system, motivated by the DarkLight experiment, using helical-shape scintillating fibers in a solenoidal magnetic field to veto electron–proton elastic scattering and the associated radiative processes. We also assess the performance of a tracking detector for lepton final states using scintillating fibers in the same setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Positron annihilation lifetime spectroscopy using fast scintillators and digital electronics

Positron Annihilation Lifetime Spectroscopy (PALS) is a non-destructive radiological technique widely used in material science studies. PALS typically relies on an analog coincidence measurement setup and allows the estimate of the positron lifetime in a material sample under investigation. The positron trapping at vacancies in the material results in an increased positron lifetime. In this work, we have developed and optimized a PALS experimental setup using organic scintillators, fast digitizers, and advanced pulse processing algorithms. We tested three pairs of different organic scintillators: EJ-309 liquid, EJ-276 newly developed plastic, and BC- 418 plastic, and optimized the data processing parameters for each pair separately. Our high-throughput data analysis method is based on single-pulse interpolation and a constant fraction discrimination (CFD) algorithm. The setup based on the BC-418 detector achieved the best time resolution of 198.3 ± 0.8 ps. We used such optimized setup to analyze two single-crystal quartz samples and found lifetimes of 161 ± 4 ps, 343 ± 12 ps and 1.34 ± 0.05 ns, in good agreement with the characteristic time constants of this material. The proposed experimental set up achieves a time resolution comparable to the minimum positron lifetime in quartz, which makes it possible to accurately characterize material vacancies by discriminating between the lifetimes of either the spin singlet or triplet states of positronium. The optimized data processing algorithms are relevant to all the applications where fast timing is important, such as nuclear medicine and radiation imaging

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗