Ultrasonic scanning of multilayer ceramic chip capacitors

Ultrasonic scanning is compared to neutron radiography and scanning laser acoustic microscopy (SLAM). Data show that SLAM and ultrasonic scanning evaluations are in good agreement. There is poor agreement between N-ray and both ultrasonic techniques because N-ray is insensitive to all but the grossest delaminations. Statistical analysis show a good correlation between ultrasonic scanning and destructive physical analysis.

Bradley, F. N.↗

Scanning afocal laser velocimeter projection lens system

A method and apparatus for projecting and focusing parallel laser light beams from a laser doppler velocimeter on a target area are described. The system includes three lenses. Two lenses work together as a fixed afocal lens combination. The third lens is a movable scanning lens. Parallel laser beams travel from the velocimeter through the scanning lens and through the afocal lens combination and converge, i.e., are focused, somewhere beyond. Moving the scanning lens relative to the fixed afocal combination results in a scanning of the focus area along the afocal combination's optical axis.

Rhodes, D. B.↗

Visual scanning behavior and mental workload in aircraft pilots

This paper describes an experimental paradigm and a set of preliminary results which demonstrate a relationship between the level of performance on a skilled man-machine control task, the skill of the operator, the level of mental difficulty induced by an additional task imposed on the basic control task, and visual scanning performance. During a constant, simulated piloting task, visual scanning of instruments was found to vary as a function of the level of difficulty of a verbal loading task. The average dwell time of each fixation on the pilot's primary instrument increased as a function of the loading. The scanning behavior was also a function of the estimated skill level of the pilots, with novices being affected by the loading task much more than experts. The results suggest that visual scanning of instruments in a controlled task may be an indicator of both workload and skill.

Tole, J. R.↗

Cure kinetics of epoxy matrix resin by differential scanning calorimetry

A study was made on the cure kinetics of an epoxy neat-resin (Narmco 5208) using Differential Scanning Calorimetry (DSC). Two interrelated analytical methods were applied to dynamic DSC data for evaluating the kinetic parameters, such as activation energy, E, the order of reaction, n, and the total heat of polymerization (or crosslinking), delta H sub t. The first method was proposed by Ellerstein (1968), and uses a thorough differential-integral analysis of a single DSC curve to evaluate the kinetic parameters. The second method was proposed by Kissinger (1957), and uses multiple DSC curves obtained at various heating rates to evaluate E regardless of n. Kinetic analysis of Narmco 5208 epoxy resin showed that the reaction order, n, is substantially affected by the rate of heating; i.e., n is approximately 2 at slow scan rates but is reduced to 1.5 at higher scan rates. The activation energy, E, is not affected by the scan rate, and the average value of E is 25.6 + or - 1.8 kcal/mole.

Cizmecioglu, M.↗

Friction estimation technique for Galileo scan platform control

A friction estimation technique has been developed for the scan platform control of the Galileo spacecraft. The purpose of the estimation is to reduce the impact of friction in the scan platform actuator on the pointing performance of the scan platform so that tight pointing requirements can be met. The estimator operates by comparing the actual behavior of the platform with the expected behavior and attributing the difference to the presence of friction. The estimator is coupled with a proportional-integral-derivative controller to generate a control torque for the scan platform actuator. Since the algorithm will be implemented on an onboard digital computer, a stability analysis of the estimator-controller in discrete time is presented. The performance of the design is demonstrated by a sample slew test case.

Chodas, J. L.↗

Visual scanning behavior and pilot workload

Sophisticated man machine interaction often requires the human operator to perform a stereotyped scan of various instruments in order to monitor and/or control a system. For situations in which this type of stereotyped behavior exists, such as certain phases of instrument flight, scan pattern was shown to be altered by the imposition of simultaneous verbal tasks. A study designed to examine the relationship between pilot visual scan of instruments and mental workload is described. It was found that a verbal loading task of varying difficulty causes pilots to stare at the primary instrument as the difficulty increases and to shed looks at instruments of less importance. The verbal loading task also affected the rank ordering of scanning sequences. By examining the behavior of pilots with widely varying skill levels, it was suggested that these effects occur most strongly at lower skill levels and are less apparent at high skill levels. A graphical interpretation of the hypothetical relationship between skill, workload, and performance is introduced and modelling results are presented to support this interpretation.

Tole, J. R.↗

The effectiveness of using real-time eye scanning information for pilot training

A study to evaluate the idea of providing pilots feedback on their scan behavior as an instrumentional training aid was conducted jointly by NASA, Piedmont Aviation, and Old Dominion University. The study used Langley's oculometer system to provide a real-time display of the trainee's scan to the instructor pilot in the aft part of the Boeing 737 training simulator at Piedmont. The trainees' scan behavior was also video-taped for viewing by the instructor and trainee after each training session. Based on qualitative data obtained during the study, scan behavior feedback was an effective tool for pilot training.

Spady, A. A., Jr.↗

Optimized three-dimensional lenses for wide-angle scanning

Three-dimensional bootlace lens antennas with two and four focal points can be optimized to produce high-quality scanned beams over a wide field of view. For two-dimensional scanning, the planar feed locus is replaced by a curved feed locus designed to minimize path length errors. Comparisons with previous bootlace lens designs demonstrate the advantages of this focal distribution. The bifocal lens shows good scanning performance in both principal and orthogonal planes. The quadrufocal lens performs better in its principal plane than in its orthogonal plane. It is also shown that the quadrufocal lens can be realized with a planar outer surface and a circular focal arc, and improved scanning performance is still achievable. Further optimization of the focal arc and/or relaxation of the planar outer surface condition results in quadrufocal lenses with negligible phase errors in the principal plane.

Rappaport, C. M.↗

Noninterlaced-To-Interlaced Television-Scan Converter

Computer text and ordinary images displayed together without text jitter. Scan converter enables superposition of alphanumerical text generated by computer-driven video generator on National Television System Committee (NTSC) standard interlaced-scan image. Made of commercially available integrated circuits and operates in conjunction with NTSC synchronizing-signal generator. Standard television picture transmitted in two interlaced fields. Without scan converter, text image moves up and down by one line as fields change. With scan converter, text image stands still.

Morales, Sergio↗

Systems for ultrasonic scanning, analysis and imagery

A variety of ultrasonic scanning and imagery techniques are used to investigate various aspects of materials and microstructures. Two ultrasonic scanning systems are in use by the Lewis Research Center's Structural Integrity Branch: an immersion scanner and a contact scanning system. The basic principles of scanning are reviewed, examples of images are presented, and structural features suggested by these images are discussed. Both of these systems are custom designed; their capabilities, advantages, and disadvantages are highlighted.

Stang, David B.↗

Image reconstruction from multiple 1-D scans using filtered localized projection

The spatial resolution that can be attained using scanning linear arrays (consisting of discrete IR solid-state detectors) for image acquisition is considered, and a filtered local projection (FLP) method is described which efficiently combines all available scan information into one rectangular grid without the need for explicit interpolation. Mathematically, the FLP algorithm consists of a localized summation followed by an inverse-filter operation, and it has application to nonlinear restoring techniques. The present method is applied, using a linear array, to simulated data for staggered parallel scans and to multiple scan directions. Noise effects and limitations of the technique are also considered.

Frieden, B. Roy↗

Scan-independent slot arrays with parasitic wire arrays in stratified medium

The effect of a parasitic wire array on the scan admittance of a slot array has been investigated. Structures considered can consist of an infinite slot array and an arbitrary number of parasitic infinte arrays of piecewise linear wires, all arrays being embedded in a stratified medium. These include, as particular cases, phased arrays of Clavin elements. Expressing the fields from the arrays as plane waves, a procedure similar to the periodic moment method for infinite periodic structures is set up to obtain the the scan admittance of the slot array. Scan admittances are presented for a slot array with monopole arrays in free space, and a slot array with a tilted dipole array in a stratified medium. Blind spots at which the incident energy is mainly reflected rather than transmitted were found. Results obtained indicate the possibility of using parasitic wire arrays for scan compensation of active slot arrays.

Ng, Kwong T.↗

Tuning and scanning control system for high resolution alexandrite lasers

An alexandrite laser is spectrally narrowed and tuned by the use of three optical elements. Each element provides a successively higher degree of spectral resolution. The digitally controlled tuning and scanning control servo system simultaneously positions all three optical elements to provide continuous high resolution laser spectral tuning. The user may select manual, single, or continuous modes of automated scanning of ranges up to 3.00/cm and at scan rates up to 3.85/cm/min. Scanning over an extended range of up to 9.999/cm may be achieved if the highest resolution optic is removed from the system. The control system is also capable of being remotely operated by another computer or controller via standard RS-232 serial data link.

Smith, James C.↗

Unbalanced Rotating Masses For Scanning

Unbalanced rotating masses low-cost, low-power, lightweight means of generating scanning torques for scientific instruments. Imparts variety of scanning patterns; continuous circular, back-and-forth linear, and, with aid of indexing mechanism, raster. Scanning rate determined by sizes of moment arms and rotational velocities. System of unbalanced rotating masses proposed for scanning gimbaled sensors that observe Sun from balloon-borne gondola. Two unbalanced masses move sensor aim in circular pattern around center of the Sun.

Polites, Michael E.↗

Reconfiguring the RUM experiment to test circular scanning with rotating unbalanced-mass devices on gimbaled payloads

This paper describes a ground-based experiment designed to prove the concept of circular scanning a gimbaled payload with rotating unbalanced-mass (RUM) devices. The experiment is a modified version of a similar experiment which demonstrates line and raster scanning with RUM's. In this paper, a description of the experiment hardware is presented and a detailed design of the servos used in scanning is given. A computer simulation model of the entire system is discussed and simulation results are included. These verify the servo designs and show the RUM's to be an extremely power efficient method for circular scanning.

Polites, M. E.↗

Scanning Tunneling Microscope For Use In Vacuum

Scanning tunneling microscope with subangstrom resolution developed to study surface structures. Although instrument used in air, designed especially for use in vacuum. Scanning head is assembly of small, mostly rigid components made of low-outgassing materials. Includes coarse-positioning mechanical-translation stage, on which specimen mounted by use of standard mounting stub. Tunneling tip mounted on piezoelectric fine-positioning tube. Application of suitable voltages to electrodes on piezoelectric tube controls scan of tunneling tip across surface of specimen. Electronic subsystem generates scanning voltages and collects data.

Abel, Phillip B.↗

Radar sensitivity and antenna scan pattern study for a satellite-based Radar Wind Sounder (RAWS)

Modeling global atmospheric circulations and forecasting the weather would improve greatly if worldwide information on winds aloft were available. Recognition of this led to the inclusion of the LAser Wind Sounder (LAWS) system to measure Doppler shifts from aerosols in the planned for Earth Observation System (EOS). However, gaps will exist in LAWS coverage where heavy clouds are present. The RAdar Wind Sensor (RAWS) is an instrument that could fill these gaps by measuring Doppler shifts from clouds and rain. Previous studies conducted at the University of Kansas show RAWS as a feasible instrument. This thesis pertains to the signal-to-noise ratio (SNR) sensitivity, transmit waveform, and limitations to the antenna scan pattern of the RAWS system. A dop-size distribution model is selected and applied to the radar range equation for the sensitivity analysis. Six frequencies are used in computing the SNR for several cloud types to determine the optimal transmit frequency. the results show the use of two frequencies, one higher (94 GHz) to obtain sensitivity for thinner cloud, and a lower frequency (24 GHz) to obtain sensitivity for thinner cloud, and a lower frequency (24 GHz) for better penetration in rain, provide ample SNR. The waveform design supports covariance estimation processing. This estimator eliminates the Doppler ambiguities compounded by the selection of such high transmit frequencies, while providing an estimate of the mean frequency. the unambiguous range and velocity computation shows them to be within acceptable limits. The design goal for the RAWS system is to limit the wind-speed error to less than 1 ms(exp -1). Due to linear dependence between vectors for a three-vector scan pattern, a reasonable wind-speed error is unattainable. Only the two-vector scan pattern falls within the wind-error limits for azimuth angles between 16 deg to 70 deg. However, this scan only allows two components of the wind to be determined. As a result, a technique is then shown, based on the Z-R-V relationships, that permit the vertical component (i.e., rain) to be computed. Thus the horizontal wind components may be obtained form the covariance estimator and the vertical component from the reflectivity factor. Finally, a new candidate system is introduced which summarizes the parameters taken from previous RAWS studies, or those modified in this thesis.

Stuart, Michael A.↗

Directivity versus element spacing for a scanning array

The results of the present examination of the relationship of directivity with element spacings of linear, rectangular, and hexagonal arrays indicate that element spacings for optimal directivity vary with scan angles; this is especially true in the case of changes in aperture sizes and the appearance of grating lobes in the visible space. Grating lobe effects are more pronounced for isotropic than for directive element arrays. Directivity decreases as the beam scans off from boresight, and rapidly diminishes for scans over 30 deg. The hexagonal array has higher directivity for scans of less than 20 deg, and the linear array for those over 30 deg.

Zimmerman, M.↗