Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAPPHIRE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

TEM Characterization of Solar Wind Effects on Genesis Mission Silicon Collectors

The Genesis Discovery Mission passively allowed solar wind (SW) to implant into substrates during exposure times up to ~853 days from 2001 to 2004. The spacecraft then returned the SW to Earth for analysis. Substrates included semiconductor wafers (silicon, sapphire, and germanium), as well as a number of thin films supported by either silicon or sapphire wafers. During flight, subsets of the SW collectors were exposed to one of 4 SW regimes: bulk solar wind, coronal hole solar wind (CH, high speed), interstream solar wind (IS, low speed) or coronal mass ejections (CMEs). Each SW regime had a different composition and range of ion speeds and, during their collection, uniquely changed their host SW collector. This study focuses on bulk vs IS SW effects on CZ silicon.

Allums, K. K.↗

Center for Isotope Cosmochemistry and Geochronology at NASA Johnson Space Center

Ten years in the making the Center for Isotope Cosmochemistry and Geochronology (CICG) at NASA Johnson Space Center is designed to be a cooperative analytical facility where novel techniques are developed and performed. Our team works collaboratively to operate this integrated lab suite comprising sample preparation, metal-free clean chemistry, and mass spectrometers to measure a wide variety of elements and isotopes in astromaterials. Contamination control is enacted throughout by a positive pressure cascade of HEPA filtered air, weekly surface cleaning and particle counting. Astromaterials processing is performed with application-specific mortar and pestles, heavy liquid separation, a Frantz magnetic separator, as well as hand-picking using optical microscopes in laminar flow boxes. Microsampling is also carried out using a New Wave MicroMill. Elements for isotopic analysis are isolated from acid-digested samples using ion-exchange chromatography. Cross-contamination is minimized with dedicated laminar flow boxes and labware for different purification protocols. Instrumentation includes a ThermoFisher Element XR inductively coupled plasma mass spectrometer (ICP-MS) for quantification of elemental concentrations in dissolved sample solutions. For in situ analysis, a Teledyne Photon Machines Analyte Excite+ laser ablation system is coupled to the Element XR. The ThermoFisher Triton thermal ionization mass spectrometer (TIMS) is used to measure the isotopic composition of elements such as CA, K, Cr, Rb, Sr, Sm, Nd at high precision in processed samples. For a more diverse range of isotopic analyses, CICG houses a Nu Sapphire 1700 multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS), which is a large geometry instrument with a multi-pole collision cell for interference removal. An Applied Spectra Instruments J200 femto-second laser is planned for install this Fall and will be coupled to the Nu Sapphire 1700. NASA’s Internal Scientist Funding Model (ISFM)supports this facility. Advanced analytical geochemistry techniques are applied to targeted astromaterials to address important problems in planetary sciences, with a longer-term goal of preparing for samples collected and returned by space missions. CICG is open to collaborations on projects that utilize the facility’s unique capabilities and are within its research scope. We are particularly eager to support and share expertise with the next generation of planetary scientists.

Justin I Simon↗

Conceptual Design of a Test Section for a Cryogenic Transfer Line Experiment

This project presents the development of a comprehensive computer-aided design (CAD) model for the Transfer Line test section, which is an upcoming test module for the Flow Boiling and Condensation Experiment (FBCE) aboard the International Space Station. The FBCE aims to serve as the primary platform to study two-phase flow in microgravity, and the Transfer Line module aims to utilize its existing hardware to study cryogenic chilldown; a critical component of cryogenic propellant transfer in space. The CAD model was created using SolidWorks software and includes the test section’s main components: a heat transfer line, a flow visualization line, insulation, high-speed visible imaging, and infrared imaging. The heat transfer line primarily consists of a stainless steel tube that will be heated via Joule heating. The flow visualization line consists of segmented Indium-Titanium-Oxide coated sapphire tubes, which allow for visualization of flow regimes by high-speed and infrared cameras, similar thermal properties as the stainless steel tube, and Joule heating via the ITO coating resistance. Polyether Ether Ketone was used to insulate and encapsulate the two sections. High-speed visible imaging and infrared imaging were also incorporated to view the propagation of fluid during inverted annular flow and map out the thermal profile of the ITO-coated sapphire tube. This model serves as the guiding concept design for the Transfer Line project and will assist the project team during future safety reviews and concept design reviews. Overall, this work is significant in two-phase flow research and offers a promising path towards an established facility for cryogenic transfer line research in microgravity.

Flow boiling↗

Current Status of Martian Moons eXploration (MMX) Contamination Control and Curation Activity

Martian Moons eXploration (MMX) is a sample return mission from the Martian moon Phobos. The MMX spacecraft is scheduled to launch in 2026 and return to Earth in 2031. The main science goals of MMX are “to reveal the origin of the Martian moons and make progress in the understanding of planetary system formation and material transport in the solar system, and to observe processes that impact the circumplanetary and surface environments of Mars”. MMX has two sampling systems: coring (C)-sampler and pneumatic (P)-sampler and plans to bring back >10 g of Phobos sample. The retuned sample in the sample capsule will be transferred to the curation facility in ISAS/JAXA for sample curation and subsequent sample analysis. Contamination control of the sample return mission requires special care to prevent terrestrial contamination to the spacecraft, which would ruin the scientific value of the returned sample. Retaining the pristineness of the retuned sample is an important task of the MMX Curation and Sampler Science teams. The basis of the contamination control is (1) to minimize and understand the nature and amount of contaminants, (2) to perform contamination assessment and evaluate the effect of contaminants in the spacecraft on the retuned sample, (3) to employ a contamination knowledge (CK) material coupon in the spacecraft to identify the contaminants in the returned samples. In the MMX contamination control plan, the allowable contamination level for each contaminant is carefully defined. They are mostly set to be 1/1000 of the expected amount of each material in the returned sample and are divided into two main categories: organic and inorganic. The allowable atmospheric leakage rate to the sample container is also defined. The allowable contamination level of the organic materials is based on the composition of carbonaceous chondrites. The target contaminants are amino acids, aliphatic and aromatic hydrocarbons, carboxylic acids, etc. In case of the inorganic materials, the target contaminants are important elements to permit distinguishing the origin of the Martian moon by nucleosynthetic isotope anomalies (Cr, Ti, and Mo) and to reveal the evolution of the Martian moon by chronology (Hf, W, U, Pb, Rb, Sr, Sm, and Nd). The key instrument of contamination control in the sample return mission is the sampler system. The C-sampler has been developed by JAXA and the P-sampler was provided by Honeybee/NASA. In MMX, materials used in the two samplers (C- and P- sampler) were carefully selected to avoid potential contamination from the design stage of the system. The individual parts of the C-sampler FM (Flight Model) were thoroughly cleaned at the curation facility in ISAS/JAXA by the full-course cleaning procedure, which is an ultrasonic cleaning with organic solvents and ultrapure water in several steps. The equivalent level of cleaning was also carried out on the P-Samper FM as well by Honeybee Robotics in the USA. Now, MMX is in the critical phase for contamination control called ATLO: Assembly, Test, and Launch Operations. During the ATLO phase, sampler FM is constantly purged with nitrogen gas and maintained at positive pressure to prevent environmental contamination. The surrounding environments of the sampler FM are also simultaneously monitored using the CK Monitoring Coupon Set, which consists of several witness materials such as a glass petri dish, sapphire glass disk, and carbon adhesive tape (Figure 1). The detailed environmental assessment of each clean room used for the assembly and test of the sampler FM has also been conducted. This assessment includes microbial analysis, which was performed for OSIRIS-REx. Regarding the sample recovery and sample curation, we have started the designing of Sample Container Disassembling Instrument for the sample recovery from the sample container and the MMX curation chamber for sample curation. The curation protocol for the Phobos returned sample has also been discussed by the MMX Sample Analysis Working Team (SAWT). The MMX curation protocol consists of three phases: (1) quick analysis, (2) pre-basic characterization, and (3) basic characterization. (1) is extraction of the sample gas from the sample container and analysis by mass spectrometry, (2) is observation in bulk level, and (3) is observation in grain level and allocation of the sample aliquots. In parallel with the curation protocol, the returned sample undergoes preliminary examination for scientific investigations to achieve science goals. In addition, the CK witness plates made of sapphire glass are on board the sampler system. The CK witness plates will be recovered from the sampler system and analyzed by SAWT for the assessment of in-flight contamination.

Haruna Sugahara↗

An Optical Streaking Method for Measuring Femtosecond Electron Bunches

The measurement of the ultra-short electron bunch length on the femtosecond time scale constitutes a very challenging problem. In the x-ray free electron laser facilities such as the Linac Coherent Light Source, generation of a sub-ten femtoseconds electron beam with 20pC charge is possible, but direct measurements are very difficult due to the resolution limit of the present diagnostics. We propose a new method here based on the measurement of the electron beam energy modulation induced from laser-electron interaction in a short wiggler. A typical optical streaking method requires a laser wavelength much longer than the electron bunch length. In this paper a laser with its wavelength shorter than the electron bunch length has been adopted, while the slope on the laser intensity envelope is used to distinguish the different periods. With this technique it is possible to reconstruct the bunch longitudinal profile from a single shot measurement. Generation of ultrashort x-ray pulses at femtoseconds (fs) scale is of great interest within synchrotron radiation and free electron laser (FEL) user community. One of the simple methods is to operate the FEL facility at low charge. At the Linac Coherent Light Source (LCLS), we have demonstrated the capability of generating ultrashort electron-beam (e-beam) with a duration of less than 10 fs fwhm using 20 pC charge. The x-ray pulses have been delivered to the x-ray users with a similar or even shorter pulse duration. However, The measurement of such short electron or x-ray pulse length at the fs time-scale constitutes a challenging problem. A standard method using an S-band radio-frequency (rf) transverse deflector has been established at LCLS, which works like a streak camera for electrons and is capable of resolving bunch lengths as short as 25 fs fwhm. With this device, the electrons are transversely deflected by the high-frequency time-variation of the deflecting fields. Increasing the deflecting voltage and rf frequency are the right direction to achieve a better resolution. For example, by choosing an X-band transverse deflecting cavity, the expected resolution for LCLS beam with 4.3 GeV is about 1 fs rms. Typically the rf breakdown threshold and the power source availability prevent going to even higher voltage and frequency. With the highly-developed laser techniques, we can choose to streak the beam at optical frequencies. By jumping from rf to optical frequency, the wavelength is shortening by 4 to 5 orders. With an electron bunch length shorter than half period of the laser, we can apply the similar rf deflecting or zero-phasing method for e-beam bunch length measurements using a high-power laser. A short wiggler is required to provide interaction between the electron and the laser. For example, to measure the e-beam at the order of 1 m rms length, a laser with its wavelength of 10 {mu}m may be considered. For a typical few GeV e-beam, the wiggler period has to be large to satisfy the resonance condition. Also, if the e-beam is longer than one laser period, the different modulation periods will overlap and we cannot distinguish them. So this method is so far limited by the achievable long-wavelength laser power. To get an effective modulation on an e-beam of 4.3 GeV, the required laser power is about a few tens GW. In this paper we propose to adopt a high-power Ti:Sapphire laser (wavelength of 800 nm), and use the slope in the intensity envelope to distinguish the different modulation periods. First an ultrashort electron beam interacts with the Ti:Sapphire laser in a wiggler, where the electron energy is modulated at the same periods of the laser. If the laser pulse is long and the short electron bunch is overlapped (in time) with the middle part of the laser, such as the setup at LCLS laser heater, the different energy modulation periods on the electron beam will be overlapped on the energy profile. In this conditionwe typically have a double-horn distribution of the energy profile, and the electron-bunch length information cannot be retrieved. But if the laser pulse (with a Gaussian temporal shape) is relatively short, we can synchronize the e-beam with the laser at the slope region of the intensity envelope, and the amplitude of each energy modulation period will be different. Then these electrons pass through a dispersive section such as a spectrometer, after that this periodically-modulated energy profile can be observed in a transverse screen. By properly choosing the laser parameters, each modulation period will show as a separate streak on the screen. This modulation period in energy dimension correlates to the laser wavelength in time dimension. Since the laser wavelength is a known parameter, no additional calibration is needed. This provides a single shot, self-calibrated method for ultrashort electron bunch length measurements.

43 PARTICLE ACCELERATORS↗

Laser Ion Source Development at HRIBF

This report describes the efforts made to develop a resonant-ionization laser ion source based on tunable Ti:Sapphire lasers for nuclear physics and astrophysics research at HRIBF. Three Ti:Sapphire lasers have been upgraded with individual pump lasers to eliminate laser power losses due to synchronization delays. Ionization schemes for 14 elements have been obtained. Off-line studies show that the overall efficiency of the laser ion source can be as high as 40%. TaC surface coatings have been investigated for minimizing surface and bulk trapping of the atoms of interest.

Liu, Yuan↗

RF Surface Impedance Characterization of Potential New Materials for SRF-based Accelerators

In the development of new superconducting materials for possible use in SRF-based accelerators, it is useful to work with small candidate samples rather than complete resonant cavities. The recently commissioned Jefferson Lab RF Surface Impedance Characterization (SIC) system can presently characterize the central region of 50 mm diameter disk samples of various materials from 2 to 40 K exposed to RF magnetic fields up to 14 mT at 7.4 GHz. We report the recent measurement results of bulk Nb, thin film Nb on Cu and sapphire substrates, Nb{sub 3}Sn sample, and thin film MgB{sub 2} on sapphire substrate provided by colleagues at JLab and Temple University.

36 MATERIALS SCIENCE↗

Surface Impedance of Superconducting Radio Frequency (SRF) Materials

Superconducting radio frequency (SRF) technology is widely adopted in particle accelerators. There remain many open questions, however, in developing a systematic understanding of the fundamental behavior of SRF materials, including niobium treated in different ways and various other bulk/thin film materials that are fabricated with different methods under assorted conditions. A facility that can measure the SRF properties of small samples in a range of 2-40 K temperature is needed in order to fully answer these questions. The Jefferson Lab surface impedance characterization (SIC) system has been designed to attempt to meet this requirement. It consists of a sapphire-loaded cylindrical Nb TE011 cavity at 7.4 GHz with a 50 mm diameter flat sample placed on a non-contacting end plate and uses a calorimetric technique to measure the radio frequency (RF) induced heat on the sample. Driving the resonance to a known field on this surface enables one to derive the surface resistance of a relatively small localized area. TEo11 mode identification has been done at room temperature and 4 K, and has been compared with Microwave Studio® and SuperFish simulation results. RF loss mechanisms in the SIC system are under investigation. A VCO phase lock loop system has been used in both CW and pulsed mode. Two calorimeters, with stainless steel and Cu as the thermal path material for high precision and high power versions, respectively, have been designed and commissioned for the SIC system to provide low temperature control and measurement. A power compensation method has been developed to measure the RF induced power on the sample. Simulation and experimental results show that with these two calorimeters, the whole thermal range of interest for SRF materials has been covered. The power measurement error in the interested power range is within 1.2% and 2.7% for the high precision and high power versions, respectively. Temperature distributions on the sample surface for both versions have been simulated and the accuracy of sample temperature measurements have been analysed. Both versions have the ability to accept bulk superconductors and thin film superconducting samples with a variety of substrate materials such as AI, Al20 3 , Cu, MgO, Nb and Si. Tests with polycrystalline and large grain bulk Nb samples have been done at <15 mT magnetic field. Based on BCS surface impedance, least-squares fittings have been done using SuperFit2.0, a code developed by G. Ciovati and the author. Microstructure analyses and SRF measurements of large scale epitaxial MgB2 films have been reported. MgB2 films on 5 em dia. sapphire disks were fabricated by a Hybrid Physical Chemical Vapor Deposition (HPCVD) technique. The electron-beam backscattering diffraction (EBSD) results suggest that the film is a single crystal complying with a MgB2(0001 )//AI203(0001) epitaxial relationship. The SRF properties of different film thicknesses (200 nm and 350 nm) were evaluated using SIC system under different temperatures and applied fields at 7.4 GHz. A surface resistance of 9±2 1-10 has been observed at 2.2 K. Based on BCS theory with moving Cooper pairs, the electron states distribution at OK and the probability of electron occupation with finite temperature have been derived and applied to anomalous skin effect theory to obtain the surface impedance of a superconductor with moving Cooper pairs. We present the numerical results for Nb.

Xiao, Binping↗

Structural Characterization of Nb Films Deposited by ECR Plasma Energetic Deposition on Crystalline Insulators

An energetic condensation thin film coating technique with an electron cyclotron resonance (ECR) induced plasma ion source is used to deposit Nb thin films on crystalline insulating substrates, such as a-plane and c-plane sapphire (Al2O3) and on magnesium oxide, MgO (100), (110) and (111). Heteroepitaxial Nb films were produced by ECR deposition with regulated substrate temperature. The residual resistance ratio (RRR) of about 1 micron thick films reach unprecedented values (350 - 450) on (11-20) sapphire substrates. The epitaxial relationship of Nb/crystalline substrate is found to be strongly influenced by the substrate bias voltage (adding to the initial Nb+ kinetic energy), the substrate crystalline orientation, and heating conditions. At low substrate temperature, the Nb films demonstrated non-epitaxial crystalline textures, revealed by XRD Pole Figure technique and Electron Backscattering Diffraction (EBSD). The texture might be caused by ?Volmer-Weber? growth mode, i.e. island growth, at low surface adatom mobility. This study shows that the film?s crystal structural character has great impact on its RRR/Tc value, which in turn is related to the electron-mean-free-path of radio-frequency superconductivity. The knowledge learned from this research sheds some light on how to coat low-defect density Nb thin films on SRF cavity-preferred metallic substrates, such as Cu.

Zhao, X.↗

X-ray Pole Figure Analysis on Fiber Textured Epitaxial Niobium Films for SRF Cavities

Single and large grain Nb films are of interest to reduce the cost of SRF cavities. The structural properties and SRF potential of Nb films obtained by coaxial energetic deposition (CEDTM) in an ultra-high vacuum process are compared and discussed. The CEDTM is a hybrid technique with both energetic ion deposition and implantation phases based on cathodic arc plasma sources, which are copious generators of condensable energetic (20-200 eV), multiply charged ions from metal or alloy cathodes. The X-ray pole figure of the thin films revealed grain orientations on Nb films grown at different substrate temperatures that indicate good structural and electrical properties. Single crystalline 110 epilayers of Nb films are grown on a-plane sapphire substrates at 400 degreeC, but at lower temperature, there are two kinds of twins in which the grains are rotated by ~45 degree about the film normal. RRR of ~129 and Tc=9.2K were measured on a Nb film on a-plane sapphire substrate at 400 degreeC, dropping to ~4 on a room temperature substrate.

Seo, Kang↗

Defining Probe Closure Offset and Scan Stitching Methodology for Element Contact Profilometry in the Hot Fuel Examination Facility

The Element Contact Profilometer (ECP) is a non-destructive post-irradiation examination (PIE) method established in the Materials and Fuels Complex (MFC) Hot Fuel Examination Facility (HFEF). The ECP suspends a fuel rod with a standard end-fitting in a vertical orientation and draws it between two opposed Sony probes with sapphire rod tips, which measure the diameter directly as a function of vertical stage position through contact profilometry. The ECP is equipped with concave rollers, which pinch the rod to maintain a consist position between these sapphire probe tips. A schematic of the analysis head is shown in Figure 1. The gripper that suspends the rod end-fitting is able to rotate to allow measuring of any azimuthal angle around the rod. This system is used to characterize the diameter of full-length light water reactor (LWR) irradiated fuel rods at multiple azimuthal angles in support of the Advanced Fuels Campaign (AFC).

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Axion dark matter search with a photonic bandgap cavity haloscope and dielectric tuning rod over 10.25-10.45 GHz

We report the development of a new widely tunable cavity and demonstrate its use in a search for dark matter axions. We achieve unloaded quality factors above $10^{5}$, roughly $25\times$ larger than a bare copper cavity at the same frequency, using concentric sapphire shells to reduce Ohmic losses on the cavity barrel. A rotating sapphire rod tunes our cavity mode over the $10.1-11.7$ GHz range, approximately $16\%$ of its resonant frequency. Using an amplified receiver chain, we demonstrate sensitivity to new axion parameter space by tuning the cavity over the $200$ MHz range between $10.25-10.45$ GHz (42.4 - 43.2, $μ$eV) to constrain the axion-to-photon coupling to $|g_{aγγ}|$$\leq$ 1 $\times$$10^{-12}$${GeV}^{-1}$. This cavity can scan its tuning range about $9$ times faster compared to a bare copper cavity when paired with a photon counting device, laying the groundwork for a definitive search for the QCD axion over $10.1-11.7$ GHz.

Lynn, Morgan [Chicago U.]↗

The selective and efficient laser ion source and trap project LIST for on-line production of exotic nuclides

Laser ion sources based on resonant excitation and ionization of atoms are well-established tools for selective and efficient production of radioactive ion beams. A recent trend is the complementary installation of reliable state-of-theart all solid-state Ti:Sapphire laser systems. To date, 35 elements of the Periodic Table are available at laser ion sources by using these novel laser systems, which complements the overall accessibility to 54 elements including use of traditional dye lasers. Recent progress in the field concerns the identification of suitable optical excitation schemes for Ti:Sapphire laser excitation as well as technical developments of the source in respect to geometry, cavity material as well as by incorporation of an ion guide system in the form of the laser ion source trap LIST.

43 PARTICLE ACCELERATORS↗

High-Voltage Superconducting Fault Current Limiters Based on High-Diffusivity Dielectric Substrates

High-temperature superconducting (HTS) tapes currently used for the manufacture of resistive fault current limiters use metallic substrates upon which the HTS film is grown. Because the alloys used for these substrates, such as Hastelloy, have a rather high resistivity and low thermal conductivity, the HTS film must be protected by a more conducting metallic layer acting as a shunt to avoid burn out during a fault. This shunt layer limits severely the electric field generated during the fault to values smaller than 100 V/m. A long length of tape is then necessary to achieve the desired high voltage. We show here that by using a high thermal diffusivity dielectric substrate such as sapphire, it is possible to obtain much higher electric fields of up to several kilovolts per meter.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fabrication and Magnetic Characterization of CFO/NiO and CFO/NiS Heterostructures

Magnetic analysis of different magnetic bilayers and multilayers is an important step for designing next-generation multiferroic heterostructures. In this study, we have investigated the magnetic interaction at the interface in CFO/NiO hetero-structures grown by pulsed laser deposition on sapphire substrates. The thin film heterostructure samples were characterized by means of X-ray diffraction, scanning electron microscopy (SEM), energy disruptive X-ray spectroscopy (EDS), and superconducting quantum interference device (SQUID) for magnetic measurements. The XRD analysis on different samples shows the crystalline growth of the thin films. The SEM-EDS analysis provides information about structural and elemental compositions of the heterostructure films. A SQUID magnetometer was used to investigate the temperature and field-dependent magnetic properties. To better understand the magnetic properties of the thin film heterostructure samples, zero field cool (ZFC) and field cool (FC) magnetization data were analyzed. At low temperature, ferromagnetic hysteresis loop was observed. A shift in the M-H hysteresis curve was observed for the FC data from the ZFC data, which indicates the presence of exchange bias effect. In addition, we have examined the effect of antiferromagnetic NiS thin films on ferromagnetism of CFO. This study on the magnetic interaction between a ferromagnetic layer and an antiferromagnetic layer can advance the frontier for applications in spin valves, magnetic sensors, and magnetic random access memory.

36 MATERIALS SCIENCE↗

Modification of the plasma-prepared As–Se–Te films and creation on their base the planar waveguides by continuous laser writing

As a result of the previous experiments (Mochalov et al. in Opt Quant Electron 49(8):274:1–274:11, 2017), it was found that the Te-based chalcogenide films prepared by plasma deposition have a transparency window in the range from 1.2 to 20 μm and cannot be modified in the two-photon absorption mode, and in the linear absorption mode only the thermal effects were observed leading to crystallization of the films or their destruction. In this work, PECVD-prepared As–Se–Te films were modified by continuous laser irradiation of different wavelengths—473, 632.8 and 808 nm. For the modification, samples with compositions As{sub 40}Se{sub 50}Te{sub 10} and As{sub 40}Se{sub 44}Te{sub 16} were deposited on a substrate of epi-polished crystalline sapphire. This paper presents the results of studying of the effect of continuous laser radiation on the optical and structural properties of the chalcogenide films samples. Also, planar waveguided structures based on the As–Se–Te films were formed and investigated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Emission from Crystals Irradiated with a Beam of Runaway Electrons

An investigation of the spectral and amplitude-temporal characteristics of emission from different crystals, promising in terms of their application as detectors of runaway electrons, is performed. This emission is excited by subnanosecond electron beams generated in a gas diode. It is found out that at the electron energies of tens–hundreds of kiloelectronvolts, the main contribution into the emission from CsI, ZnS, type IIa artificial and natural diamonds, sapphire, CaF{sub 2}, ZrO{sub 2}, Ga{sub 2}O{sub 3}, CaCO{sub 3}, CdS, and ZnSe crystals comes from the cathodoluminescence; the radiation pulse duration depends on the crystal used and sufficiently exceeds the Cherenkov radiation pulse duration. It is demonstrated that the latter radiation exhibits low intensity and can be detected in the short-wave region of the spectrum in the cases where a monochromator and a high-sensitivity photomultiplier tube (PMT) are used.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Real time reciprocal space mapping of nano-islands induced by quantum confinment.

The effects of quantum confinement have been observed pronouncedly in the island morphology of Pb thin films. The evolution of these nano-islands on Si (111)-(7 x 7) and sapphire (001) surfaces has been studied with a new X-ray diffraction method. A charge-coupled device (CCD) camera was used to collect two- and three-dimensional (2-D and 3-D, respectively) maps of the surface X-ray diffraction in real time. Large ranges of the reflectivity curves, with rocking curves at every point on the reflectivity curves, could be measured continuously in a relatively short amount of time. The abundance of information from 2-D k-space maps reveals clear changes in the growth modes of these thin Pb films. With the 3-D extension of this method, it was possible to observe the ordering of the islands. The islands maintain a nearly uniform interisland distance but lack any angular correlation. The interisland ordering is correlated well with the development of 'magic' island heights caused by quantum confinement.

36 MATERIALS SCIENCE↗