Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reproducibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 703 records · Page 39

A simple technique to reduce evaporation of crystallization droplets by using plate lids with apertures for adding liquids

This article describes the use of evaporation control lids that are fitted to crystallization plates to improve the reproducibility of trials using as little as 5 nl. The plate lids contain apertures which are large enough for the transfer of protein containing droplets, but small enough to greatly reduce the rate of evaporation during the time needed to prepare the plate. A method is described for using plate lids to reduce evaporation in low-volume vapor-diffusion crystallization experiments. The plate lids contain apertures through which the protein and precipitants were added to different crystallization microplates (the reservoir was filled before fitting the lids). Plate lids were designed for each of these commonly used crystallization microplates. This system minimizes the dehydration of crystallization droplets containing just a few nanolitres of protein and precipitant, and results in more reproducible diffraction from the crystals. For each lid design, changes in the weight of the plates were used to deduce the rate of evaporation under different conditions of temperature, air movement, droplet size and precipitant. For comparison, the state of dehydration was also visually assessed throughout the experiment. Finally, X-ray diffraction methods were used to compare the diffraction of protein crystals that were conventionally prepared against those that were prepared on plates with plate lids. The measurements revealed that the plate lids reduced the rate of evaporation by 63–82%. Crystals grown in 5 nl drops that were set up with plate lids diffracted to higher resolution than similar crystals from drops that were set up without plate lids. The results demonstrate that plate lids can be instrumental for improving few-nanolitre crystallizations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the stability of capacitance-diaphragm gauges with ceramic membranes

Capacitance-diaphragm gauges with ceramic membranes or diaphragms have been on the market for about 15 years. The long-term stability of these devices with full scales from 13 Pa to 133 kPa has been tested in the past decade by the calibration of gauges used by the manufacturer as reference gauges on the production line. These reference gauges were calibrated annually on a primary standard. It was found that the reproducibility of these devices depends on their full scale. For 13 Pa, the annual reproducibility near full scale varied between 0.02% and 0.04%, and for full scales of 133 Pa and higher, it varied between 0.005% and 0.03% of full scale. The reproducibility of the ceramic capacitance-diaphragm gauges for full scales of 133 Pa and 1.3 kPa was significantly lower than the uncertainty of a primary standard applying the static-expansion method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In vivo verification of superficial dose for head and neck treatments using intensity-modulated techniques

Skin dose is one of the key issues for clinical dosimetry in radiation therapy. Currently planning computer systems are unable to accurately predict dose in the buildup region, leaving ambiguity as to the dose levels actually received by the patient's skin during radiotherapy. This is one of the prime reasons why in vivo measurements are necessary to estimate the dose in the buildup region. A newly developed metal-oxide-semiconductor-field-effect-transistor (MOSFET) detector designed specifically for dose measurements in rapidly changing dose gradients was introduced for accurate in vivo skin dosimetry. The feasibility of this detector for skin dose measurements was verified in comparison with plane parallel ionization chamber and radiochromic films. The accuracy of a commercial treatment planning system (TPS) in skin dose calculations for intensity-modulated radiation therapy treatment of nasopharyngeal carcinoma was evaluated using MOSFET detectors in an anthropomorphic phantom as well as on the patients. Results show that this newly developed MOSFET detector can provide a minimal but highly reproducible intrinsic buildup of 7 mg cm{sup -2} corresponding to the requirements of personal surface dose equivalent Hp (0.07). The reproducibility of the MOSFET response, in high sensitivity mode, is found to be better than 2% at the phantom surface for the doses normally delivered to the patients. The MOSFET detector agrees well with the Attix chamber and the EBT Gafchromic registered film in terms of surface and buildup region dose measurements, even for oblique incident beams. While the dose difference between MOSFET measurements and TPS calculations is within measurement uncertainty for the depths equal to or greater than 0.5 cm, an overestimation of up to 8.5% was found for the surface dose calculations in the anthropomorphic phantom study. In vivo skin dose measurements reveal that the dose difference between the MOSFET results and the TPS calculations was on average -7.2%, ranging from -4.3% to -9.2%. The newly designed MOSFET detector encapsulated into a thin water protective film has a minimal reproducible intrinsic buildup recommended for skin dosimetry. This feature makes it very suitable for routine IMRT QA and accurate in vivo skin dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Implementation and validation of an ultrasonic tissue characterization technique for quantitative assessment of normal-tissue toxicity in radiation therapy

The goal of this study was to implement and validate a noninvasive, quantitative ultrasonic technique for accurate and reproducible measurement of normal-tissue toxicity in radiation therapy. The authors adapted an existing ultrasonic tissue characterization (UTC) technique that used a calibrated 1D spectrum based on region-of-interest analysis. They modified the calibration procedure by using a reference phantom instead of a planar reflector. This UTC method utilized ultrasonic radio-frequency echo signals to generate spectral parameters related to the physical properties (e.g., size, shape, and relative acoustic impedance) of tissue microstructures. Three spectral parameters were investigated for quantification of normal-tissue injury: Spectral slope, intercept, and midband fit. They conducted a tissue-mimicking phantom study to verify the reproducibility of UTC measurements and initiated a clinical study of radiation-induced breast-tissue toxicity. Spectral parameter values from measurements on two phantoms were reproducible within 1% of each other. Eleven postradiation breast-cancer patients were studied and significant differences between the irradiated and untreated (contralateral) breasts were observed for spectral intercept (p=0.003) and midband fit (p<0.001) but not for slope (p=0.14). In comparison to the untreated breast, the average difference in the spectral intercept was 2.99{+-}0.75 dB and the average difference in the midband fit was 3.99{+-}0.65 dB. The preliminary clinical study demonstrated the feasibility of using the quantitative ultrasonic method to evaluate normal-tissue toxicity in radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A solid iodinated phantom material for use in tomographic x-ray imaging

PURPOSE: Iodinated phantoms are of value in x-ray imaging for quality control measurements, system calibration, and for use in the research setting; however, the liquid phantoms that are most often used have several limitations including variability between repeated dilutions, inhomogeneities from air bubbles or precipitants, and long set up times. Although suitable materials have been investigated for projection radiography, quantitative measurements of contrast enhancement in computed tomography (CT) have become increasingly important in the clinic, and a need exists for a durable and reproducible iodinated phantom material. In this work, the authors describe a solid radiographic phantom material that has an accurately known concentration of iodine distributed uniformly throughout its volume and that has stable properties over time. This material can be molded or machined into a desired shape to create a test object or for use in an anthropomorphic phantom. Methods: Two sets of calibration phantoms were produced with a clinically relevant range of iodine concentrations. Measurements were made on these phantoms to characterize the material properties in terms of accuracy of iodine concentration, radiographic uniformity, temporal stability of x-ray attenuation, and manufacturing repeatability. Experimentally measured linear x-ray attenuation coefficients were compared to those predicted by a theoretical model. The uniformity of the iodine distribution in the material was assessed by measuring image intensity variation, both in projection images and in reconstructed CT volumes. The reproducibility of manufacture was estimated on a set of independently produced samples. A longitudinal study was performed to assess the stability of the material x-ray characteristics over time by making measurements at 6 month intervals. Results: Good agreement was seen between the experimental measurements of effective attenuation and the theoretically predicted values. It is estimated that a desired iodine concentration could be produced to within 0.04 mg/ml. Comparison of the measured effective linear iodine attenuation coefficients of eight 1.0 mg/ml samples indicated a manufacturing reproducibility of {+-}0.03 mg/ml iodine. Variations in uniformity across each of the samples were on the order of image intensity fluctuations ({sigma}). No inhomogeneities due to mixing or settling were apparent. An analysis of longitudinal data collected for both calibration sets revealed no perceptible change in radiographic properties over the first 6 months after manufacture, nor over a subsequent 1.5 yr period from 1 yr postmanufacture onward. Conclusions: The uniformity, stability, and precision of this iodinated material suggest that it is suitable for use in accurate calibration tools for contrast tomographic imaging.

36 MATERIALS SCIENCE↗

Validation of GPUMCD for low-energy brachytherapy seed dosimetry

Purpose: To validate GPUMCD, a new package for fast Monte Carlo dose calculations based on the GPU (graphics processing unit), as a tool for low-energy single seed brachytherapy dosimetry for specific seed models. As the currently accepted method of dose calculation in low-energy brachytherapy computations relies on severe approximations, a Monte Carlo based approach would result in more accurate dose calculations, taking in to consideration the patient anatomy as well as interseed attenuation. The first step is to evaluate the capability of GPUMCD to reproduce low-energy, single source, brachytherapy calculations which could ultimately result in fast and accurate, Monte Carlo based, brachytherapy dose calculations for routine planning. Methods: A mixed geometry engine was integrated to GPUMCD capable of handling parametric as well as voxelized geometries. In order to evaluate GPUMCD for brachytherapy calculations, several dosimetry parameters were computed and compared to values found in the literature. These parameters, defined by the AAPM Task-Group No. 43, are the radial dose function, the 2D anisotropy function, and the dose rate constant. These three parameters were computed for two different brachytherapy sources: the Amersham OncoSeed 6711 and the Imagyn IsoStar IS-12501. Results: GPUMCD was shown to yield dosimetric parameters similar to those found in the literature. It reproduces radial dose functions to within 1.25% for both sources in the 0.5< r <10 cm range. The 2D anisotropy function was found to be within 3% at r = 5 cm and within 4% at r = 1 cm. The dose rate constants obtained were within the range of other values reported in the literature.Conclusion: GPUMCD was shown to be able to reproduce various TG-43 parameters for two different low-energy brachytherapy sources found in the literature. The next step is to test GPUMCD as a fast clinical Monte Carlo brachytherapy dose calculations with multiple seeds and patient geometry, potentially providing more accurate results than the TG-43 formalism while being much faster than calculations using general purpose Monte Carlo codes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characteristics of an OSLD in the diagnostic energy range

Purpose: Optically stimulated luminescence (OSL) dosimetry has been recently introduced in radiation therapy as a potential alternative to the thermoluminescent dosimeter (TLD) system. The aim of this study was to investigate the feasibility of using OSL point dosimeters in the energy range used in diagnostic imaging. Methods: NanoDot OSL dosimeters (OSLDs) were used in this study, which started with testing the homogeneity of a new packet of nanoDots. Reproducibility and the effect of optical treatment (bleaching) were then examined, followed by an investigation of the effect of accumulated dose on the OSLD indicated doses. OSLD linearity, angular dependence, and energy dependence were also studied. Furthermore, comparison with LiF:Mg,Ti TLD chips using standard CT dose phantoms at 80 and 120 kVp settings was performed. Results: Batch homogeneity showed a coefficient of variation of <5%. Single-irradiation measurements with bleaching after each OSL readout was found to be associated with a 3.3% reproducibility (one standard deviation measured with a 8 mGy test dose), and no systematic change in OSLDs sensitivity could be noted from measurement to measurement. In contrast, the multiple-irradiation readout without bleaching in between measurements was found to be associated with an uncertainty (using a 6 mGy test dose) that systematically increased with accumulated dose, reaching 42% at 82 mGy. Good linearity was shown by nanoDots under general x-ray, CT, and mammography units with an R{sup 2} > 0.99. The angular dependence test showed a drop of approximately 70% in the OSLD response at 90 deg. in mammography (25 kVp). With the general radiography unit, the maximum drop was 40% at 80 kVp and 20% at 120 kVp, and it was only 10% with CT at both 80 and 120 kVp. The energy dependence study showed a range of ion chamber-to-OSLDs ratios between 0.81 and 1.56, at the energies investigated (29-62 keV). A paired t-test for comparing the OSLDs and TLDs showed no significant variation (p > 0.1). Conclusions: OSLDs exhibited good batch homogeneity (<5%) and reproducibility (3.3%), as well as a linear response. In addition, they showed no statistically significant difference with TLDs in CT measurements (p > 0.1). However, high uncertainty (42%) in the dose estimate was found as a result of relatively high accumulated dose. Furthermore, nanoDots showed high angular dependence (up to 70%) in low kVp techniques. Energy dependence of about 60% was found, and correction factors were suggested for the range of energies investigated. Therefore, if angular and energy dependences are taken into consideration and the uncertainty associated with accumulated dose is avoided, OSLDs (nanoDots) can be suitable for use as point dosimeters in diagnostic settings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a dynamic flow imaging phantom for dynamic contrast-enhanced CT

Purpose: Dynamic contrast enhanced CT (DCE-CT) studies with modeling of blood flow and tissue perfusion are becoming more prevalent in the clinic, with advances in wide volume CT scanners allowing the imaging of an entire organ with sub-second image frequency and sub-millimeter accuracy. Wide-spread implementation of perfusion DCE-CT, however, is pending fundamental validation of the quantitative parameters that result from dynamic contrast imaging and perfusion modeling. Therefore, the goal of this work was to design and construct a novel dynamic flow imaging phantom capable of producing typical clinical time-attenuation curves (TACs) with the purpose of developing a framework for the quantification and validation of DCE-CT measurements and kinetic modeling under realistic flow conditions. Methods: The phantom is based on a simple two-compartment model and was printed using a 3D printer. Initial analysis of the phantom involved simple flow measurements and progressed to DCE-CT experiments in order to test the phantoms range and reproducibility. The phantom was then utilized to generate realistic input TACs. A phantom prediction model was developed to compute the input and output TACs based on a given set of five experimental (control) parameters: pump flow rate, injection pump flow rate, injection contrast concentration, and both control valve positions. The prediction model is then inversely applied to determine the control parameters necessary to generate a set of desired input and output TACs. A protocol was developed and performed using the phantom to investigate image noise, partial volume effects and CT number accuracy under realistic flow conditionsResults: This phantom and its surrounding flow system are capable of creating a wide range of physiologically relevant TACs, which are reproducible with minimal error between experiments ({sigma}/{mu} < 5% for all metrics investigated). The dynamic flow phantom was capable of producing input and output TACs using either step function based or typical clinical arterial input function (AIF) inputs. The measured TACs were in excellent agreement with predictions across all comparison metrics with goodness of fit (R{sup 2}) for the input function between 0.95 and 0.98, while the maximum enhancement differed by no more than 3.3%. The predicted output functions were similarly accurate producing R{sup 2} values between 0.92 and 0.99 and maximum enhancement to within 9.0%. The effect of ROI size on the arterial input function (AIF) was investigated in order to determine an operating range of ROI sizes which were minimally affected by noise for small dimensions and partial volume effects for large dimensions. It was possible to establish the measurement sensitivity of both the Toshiba (ROI radius range from 1.5 to 3.2 mm ''low dose'', 1.4 to 3.0 mm ''high dose'') and GE scanner (1.5 to 2.6 mm ''low dose'', 1.1 to 3.4 mm ''high dose''). This application of the phantom also provides the ability to evaluate the effect of the AIF error on kinetic model parameter predictions. Conclusions: The dynamic flow imaging phantom is capable of producing accurate and reproducible results which can be predicted and quantified. This results in a unique tool for perfusion DCE-CT validation under realistic flow conditions which can be applied not only to compare different CT scanners and imaging protocols but also to provide a ground truth across multimodality dynamic imaging given its MRI and PET compatibility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Objective models of compressed breast shapes undergoing mammography

Purpose: To develop models of compressed breasts undergoing mammography based on objective analysis, that are capable of accurately representing breast shapes in acquired clinical images and generating new, clinically realistic shapes. Methods: An automated edge detection algorithm was used to catalogue the breast shapes of clinically acquired cranio-caudal (CC) and medio-lateral oblique (MLO) view mammograms from a large database of digital mammography images. Principal component analysis (PCA) was performed on these shapes to reduce the information contained within the shapes to a small number of linearly independent variables. The breast shape models, one of each view, were developed from the identified principal components, and their ability to reproduce the shape of breasts from an independent set of mammograms not used in the PCA, was assessed both visually and quantitatively by calculating the average distance error (ADE). Results: The PCA breast shape models of the CC and MLO mammographic views based on six principal components, in which 99.2% and 98.0%, respectively, of the total variance of the dataset is contained, were found to be able to reproduce breast shapes with strong fidelity (CC view mean ADE = 0.90 mm, MLO view mean ADE = 1.43 mm) and to generate new clinically realistic shapes. The PCA models based on fewer principal components were also successful, but to a lesser degree, as the two-component model exhibited a mean ADE = 2.99 mm for the CC view, and a mean ADE = 4.63 mm for the MLO view. The four-component models exhibited a mean ADE = 1.47 mm for the CC view and a mean ADE = 2.14 mm for the MLO view. Paired t-tests of the ADE values of each image between models showed that these differences were statistically significant (max p-value = 0.0247). Visual examination of modeled breast shapes confirmed these results. Histograms of the PCA parameters associated with the six principal components were fitted with Gaussian distributions. The six-component model was also used to generate CC and MLO view mammogram breast shapes, using the mean PCA parameter values of these distributions and randomly generated values based on the fitted Gaussian distributions, which resemble clinically encountered breasts. A spreadsheet with the data necessary to apply this model is provided as the supplementary material. Conclusions: Our PCA models of breast shapes in both mammographic views successfully reproduce analyzed breast shapes and generate new clinically relevant shapes. This work can aid in research applications which incorporate breast shape modeling, such as x-ray scatter correction, dosimetry, and image registration.

60 APPLIED LIFE SCIENCES↗

Dosimetric properties of an amorphous silicon EPID for verification of modulated electron radiotherapy

Purpose: To investigate the dosimetric properties of an electronic portal imaging device (EPID) for electron beam detection and to evaluate its potential for quality assurance (QA) of modulated electron radiotherapy (MERT). Methods: A commercially available EPID was used to detect electron beams shaped by a photon multileaf collimator (MLC) at a source-surface distance of 70 cm. The fundamental dosimetric properties such as reproducibility, dose linearity, field size response, energy response, and saturation were investigated for electron beams. A new method to acquire the flood-field for the EPID calibration was tested. For validation purpose, profiles of open fields and various MLC fields (square and irregular) were measured with a diode in water and compared to the EPID measurements. Finally, in order to use the EPID for QA of MERT delivery, a method was developed to reconstruct EPID two-dimensional (2D) dose distributions in a water-equivalent depth of 1.5 cm. Comparisons were performed with film measurement for static and dynamic monoenergy fields as well as for multienergy fields composed by several segments of different electron energies. Results: The advantageous EPID dosimetric properties already known for photons as reproducibility, linearity with dose, and dose rate were found to be identical for electron detection. The flood-field calibration method was proven to be effective and the EPID was capable to accurately reproduce the dose measured in water at 1.0 cm depth for 6 MeV, 1.3 cm for 9 MeV, and 1.5 cm for 12, 15, and 18 MeV. The deviations between the output factors measured with EPID and in water at these depths were within {+-}1.2% for all the energies with a mean deviation of 0.1%. The average gamma pass rate (criteria: 1.5%, 1.5 mm) for profile comparison between EPID and measurements in water was better than 99% for all the energies considered in this study. When comparing the reconstructed EPID 2D dose distributions at 1.5 cm depth to film measurements, the gamma pass rate (criteria: 2%, 2 mm) was better than 97% for all the tested cases. Conclusions: This study demonstrates the high potential of the EPID for electron dosimetry, and in particular, confirms the possibility to use it as an efficient verification tool for MERT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality assurance of proton beams using a multilayer ionization chamber system

Purpose: The measurement of percentage depth-dose (PDD) distributions for the quality assurance of clinical proton beams is most commonly performed with a computerized water tank dosimetry system with ionization chamber, commonly referred to as water tank. Although the accuracy and reproducibility of this method is well established, it can be time-consuming if a large number of measurements are required. In this work the authors evaluate the linearity, reproducibility, sensitivity to field size, accuracy, and time-savings of another system: the Zebra, a multilayer ionization chamber system.Methods: The Zebra, consisting of 180 parallel-plate ionization chambers with 2 mm resolution, was used to measure depth-dose distributions. The measurements were performed for scattered and scanned proton pencil beams of multiple energies delivered by the Hitachi PROBEAT synchrotron-based delivery system. For scattered beams, the Zebra-measured depth-dose distributions were compared with those measured with the water tank. The principal descriptors extracted for comparisons were: range, the depth of the distal 90% dose; spread-out Bragg peak (SOBP) length, the region between the proximal 95% and distal 90% dose; and distal-dose fall off (DDF), the region between the distal 80% and 20% dose. For scanned beams, the Zebra-measured ranges were compared with those acquired using a Bragg peak chamber during commissioning.Results: The Zebra demonstrated better than 1% reproducibility and monitor unit linearity. The response of the Zebra was found to be sensitive to radiation field sizes greater than 12.5 × 12.5 cm; hence, the measurements used to determine accuracy were performed using a field size of 10 × 10 cm. For the scattered proton beams, PDD distributions showed 1.5% agreement within the SOBP, and 3.8% outside. Range values agreed within −0.1 ± 0.4 mm, with a maximum deviation of 1.2 mm. SOBP length values agreed within 0 ± 2 mm, with a maximum deviation of 6 mm. DDF values agreed within 0.3 ± 0.1 mm, with a maximum deviation of 0.6 mm. For the scanned proton pencil beams, Zebra and Bragg peak chamber range values demonstrated agreement of 0.0 ± 0.3 mm with a maximum deviation of 1.3 mm. The setup and measurement time for all Zebra measurements was 3 and 20 times less, respectively, compared to the water tank measurements.Conclusions: Our investigation shows that the Zebra can be useful not only for fast but also for accurate measurements of the depth-dose distributions of both scattered and scanned proton beams. The analysis of a large set of measurements shows that the commonly assessed beam quality parameters obtained with the Zebra are within the acceptable variations specified by the manufacturer for our delivery system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-275: Impact of the Intra and Inter Observer Variability in the Delineation of Parotid Glands On the Dose Calculation During Head and Neck Helical Tomotherapy

Purpose: The intra- and inter-observer variability in delineation of the parotids on the kilo-voltage computed tomography (kVCT) and mega-voltage computed tomography (MVCT) were examined to establish their impact on the dose calculation during adaptive head and neck helical tomotherapy (HT). Methods: Three observers delineated left and right parotids for ten randomly selected patients with oropharynx cancer treated on HT. The pre-treatment kVCT and the MVCT from the first fraction of irradiation were selected to delineation. The delineation procedure was repeated three times by each observer. The parotids were delineated according to the institutional protocol. The analyses included intra-observer reproducibility and inter-structure, -observer and -modality variability of the volume and dose. Results: The differences between the left and right parotid outlines were not statistically significant (p>0.3). The reproducibility of the delineation was confirmed for each observer on the kVCT (p>0.2) and on the MVCT (p>0.1). The inter-observer variability of the outlines was significant (p<0.001) as well as the inter-modality variability (p<0.006). The parotids delineated on the MVCT were 10% smaller than on the kVCT. The inter-observer variability of the parotids delineation did not affect the average dose (p=0.096 on the kVCT and p=0.176 on the MVCT). The dose calculated on the MVCT was higher by 3.3% than dose from the kVCT (p=0.009). Conclusion: Usage of the institutional protocols for the parotids delineation reduces intra-observer variability and increases reproducibility of the outlines. These protocols do not eliminate delineation differences between the observers, but these differences are not clinically significant and do not affect average doses in the parotids. The volumes of the parotids delineated on the MVCT are smaller than on the kVCT, which affects the differences in the calculated doses.

60 APPLIED LIFE SCIENCES↗

SU-F-BRE-05: Development and Evaluation of a Real-Time Robotic 6D Quality Assurance Phantom

Purpose: A 6 degree-of-freedom robotic phantom capable of reproducing dynamic tumor motion in 6D was designed to more effectively match solid tumor movements throughout pre-treatment scanning and radiation therapy. With the abundance of optical and x-ray 6D real-time tumor tracking methodologies clinically available, and the substantial dosimetric consequences of failing to consider tumor rotation as well as translation, this work presents the development and evaluation of a 6D instrument with the facility to improve quality assurance. Methods: An in-house designed and built 6D robotic motion phantom was constructed following the so-called Stewart-Gough parallel kinematics platform archetype. The device was then controlled using an inverse kinematics formulation, and precise movements in all six degrees of freedom (X, Y, Z, pitch, roll, and yaw) as well as previously obtained cranial motion, were effectively executed. The robotic phantom movements were verified using a 15 fps 6D infrared marker tracking system (Polaris, NDI), and quantitatively compared to the input trajectory. Thus, the accuracy and repeatability of 6D motion was investigated and the phantom performance was characterized. Results: Evaluation of the 6D platform demonstrated translational RMSE values of 0.196 mm, 0.260 mm, and 0.101 mm over 20 mm in X and Y and 10 mm in Z, respectively, and rotational RMSE values of 0.068 degrees, 0.0611 degrees, and 0.095 degrees over 10 degrees of pitch, roll, and yaw, respectively. The robotic stage also effectively performed controlled 6D motions, as well as reproduced cranial trajectories over 15 minutes, with a maximal RMSE of 0.044 mm translationally and 0.036 degrees rotationally. Conclusion: This 6D robotic phantom has proven to be accurate under clinical standards and capable of reproducing tumor motion in 6D. Consequently, such a robotics device has the potential to serve as a more effective system for IGRT QA that involves both translational and rotational dimensions. Research was partially funded by NIH Grant T32 EB002103-21 from NIBIB. Contents are solely the responsibility of the authors and do not necessarily represent the official views of the NIBIB or NIH.

60 APPLIED LIFE SCIENCES↗

TH-C-19A-02: Characterization of An Actively Controlled Graphite Probe Calorimeter

Purpose: To construct and experimentally evaluate the performance of a miniature probe-format graphite calorimeter (GPC) with built-in active control. The GPC is the first ever calorimeter designed specifically for routine clinical use. Methods: The original GPC design, developed as part of our previous work, was modified to accommodate a micro-thin, resistive heating element and sensing thermistors embedded in the outermost graphite layer. A software-based process control loop was written to maintain a predefined set point temperature throughout the detector by precisely modulating the current flowing through the resistive element. Continuous feedback is provided to the controller by the additional thermistors. A functioning prototype was constructed in-house and operated in adiabatic mode in a 6 MV photon beam. Ten sets of measurements of varying duration (10 to 60 seconds) and repetition rate (200 to 600 MU/min) were analyzed. Reproducibility, linearity and dose rate dependence were assessed. Results: A total of 47 individual measurements were performed using the active GPC. The reproducibility, defined here as the sample standard deviation weighted across all 10 measurement sets, was found to be 0.37%. Similarly, the standard error (type A uncertainty) was 0.17%. Linearity was quantified by plotting signal as a function of monitor units delivered at 600 MU/min. The adjusted R-square of the resulting linear fit was 0.9996. Dose rate dependence, evaluated as the change in normalized response (signal/MU) as a function of repetition rate, was found to be statistically insignificant. Conclusions: The incorporation of active control has resulted in a marked improvement in the GPC's reproducibility and it allows the user to now perform measurements within minutes of setup. With this refinement, it is estimated that the overall standard uncertainty in the absolute determination of dose to water is 1%, making the GPC comparable to a calibrated ionization chamber. This research has received financial support from Sun Nuclear Corporation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a 6DOF robotic motion phantom for radiation therapy

Purpose: The use of medical technology capable of tracking patient motion or positioning patients along 6 degree-of-freedom (6DOF) has steadily increased in the field of radiation therapy. However, due to the complex nature of tracking and performing 6DOF motion, it is critical that such technology is properly verified to be operating within specifications in order to ensure patient safety. In this study, a robotic motion phantom is presented that can be programmed to perform highly accurate motion along any X (left–right), Y (superior–inferior), Z (anterior–posterior), pitch (around X), roll (around Y), and yaw (around Z) axes. In addition, highly synchronized motion along all axes can be performed in order to simulate the dynamic motion of a tumor in 6D. The accuracy and reproducibility of this 6D motion were characterized. Methods: An in-house designed and built 6D robotic motion phantom was constructed following the Stewart–Gough parallel kinematics platform archetype. The device was controlled using an inverse kinematics formulation, and precise movements in all 6 degrees-of-freedom (X, Y, Z, pitch, roll, and yaw) were performed, both simultaneously and separately for each degree-of-freedom. Additionally, previously recorded 6D cranial and prostate motions were effectively executed. The robotic phantom movements were verified using a 15 fps 6D infrared marker tracking system and the measured trajectories were compared quantitatively to the intended input trajectories. The workspace, maximum 6D velocity, backlash, and weight load capabilities of the system were also established. Results: Evaluation of the 6D platform demonstrated translational root mean square error (RMSE) values of 0.14, 0.22, and 0.08 mm over 20 mm in X and Y and 10 mm in Z, respectively, and rotational RMSE values of 0.16°, 0.06°, and 0.08° over 10° of pitch, roll, and yaw, respectively. The robotic stage also effectively performed controlled 6D motions, as well as reproduced cranial trajectories over 15 min, with a maximal RMSE of 0.04 mm translationally and 0.04° rotationally, and a prostate trajectory over 2 min, with a maximal RMSE of 0.06 mm translationally and 0.04° rotationally. Conclusions: This 6D robotic phantom has proven to be accurate under clinical standards and capable of reproducing tumor motion in 6D. Such functionality makes the robotic phantom usable for either quality assurance or research purposes.

60 APPLIED LIFE SCIENCES↗

An externally and internally deformable, programmable lung motion phantom

Purpose: Most clinically deployed strategies for respiratory motion management in lung radiotherapy (e.g., gating and tracking) use external markers that serve as surrogates for tumor motion. However, typical lung phantoms used to validate these strategies are based on a rigid exterior and a rigid or a deformable-interior. Such designs do not adequately represent respiration because the thoracic anatomy deforms internally as well as externally. In order to create a closer approximation of respiratory motion, the authors describe the construction and experimental testing of an externally as well as internally deformable, programmable lung phantom. Methods: The outer shell of a commercially available lung phantom (RS-1500, RSD, Inc.) was used. The shell consists of a chest cavity with a flexible anterior surface, and embedded vertebrae, rib-cage and sternum. A custom-made insert was designed using a piece of natural latex foam block. A motion platform was programmed with sinusoidal and ten patient-recorded lung tumor trajectories. The platform was used to drive a rigid foam “diaphragm” that compressed/decompressed the phantom interior. Experimental characterization comprised of determining the reproducibility and the external–internal correlation of external and internal marker trajectories extracted from kV x-ray fluoroscopy. Experiments were conducted to illustrate three example applications of the phantom—(i) validating the geometric accuracy of the VisionRT surface photogrammetry system; (ii) validating an image registration tool, NiftyReg; and (iii) quantifying the geometric error due to irregular motion in four-dimensional computed tomography (4DCT). Results: The phantom correctly reproduced sinusoidal and patient-derived motion, as well as realistic respiratory motion-related effects such as hysteresis. The reproducibility of marker trajectories over multiple runs for sinusoidal as well as patient traces, as characterized by fluoroscopy, was within 0.25 mm RMS error. The motion trajectories of internal and external radio-opaque markers as measured by fluoroscopy were found to be highly correlated (R > 0.95). Using the phantom, it was demonstrated that the motion trajectories of regions-of-interest on the surface as measured by VisionRT are highly consistent with corresponding fluoroscopically acquired surface marker trajectories, with RMS errors within 0.26 mm. Furthermore, it was shown that the trajectories of external and internal marker trajectories derived from NiftyReg deformation vector fields were within 1 mm root mean square errors comparing to trajectories obtained by segmenting markers from individual fluoro frames. Finally, it was shown that while 4DCT can be used to localize internal markers for sinusoidal motion with reasonable accuracy, the localization error increases significantly (by a factor of ∼2) in the presence of cycle-to-cycle variations that are observed in patient-derived respiratory motion. Conclusions: The authors have developed a realistic externally and internally deformable, programmable lung phantom that will serve as a valuable tool for clinical and investigational motion management studies in thoracic and abdominal radiation therapies.

60 APPLIED LIFE SCIENCES↗

SU-E-J-158: Audiovisual Biofeedback Reduces Image Artefacts in 4DCT: A Digital Phantom Study

Purpose: Irregular breathing motion has a deleterious impact on 4DCT image quality. The breathing guidance system: audiovisual biofeedback (AVB) is designed to improve breathing regularity, however, its impact on 4DCT image quality has yet to be quantified. The purpose of this study was to quantify the impact of AVB on thoracic 4DCT image quality by utilizing the digital eXtended Cardiac Torso (XCAT) phantom driven by lung tumor motion patterns. Methods: 2D tumor motion obtained from 4 lung cancer patients under two breathing conditions (i) without breathing guidance (free breathing), and (ii) with guidance (AVB). There were two breathing sessions, yielding 8 tumor motion traces. This tumor motion was synchronized with the XCAT phantom to simulate 4DCT acquisitions under two acquisition modes: (1) cine mode, and (2) prospective respiratory-gated mode. Motion regularity was quantified by the root mean square error (RMSE) of displacement. The number of artefacts was visually assessed for each 4DCT and summed up for each breathing condition. Inter-session anatomic reproducibility was quantified by the mean absolute difference (MAD) between the Session 1 4DCT and Session 2 4DCT. Results: AVB improved tumor motion regularity by 30%. In cine mode, the number of artefacts was reduced from 61 in free breathing to 40 with AVB, in addition to AVB reducing the MAD by 34%. In gated mode, the number of artefacts was reduced from 63 in free breathing to 51 with AVB, in addition to AVB reducing the MAD by 23%. Conclusion: This was the first study to compare the impact of breathing guidance on 4DCT image quality compared to free breathing, with AVB reducing the amount of artefacts present in 4DCT images in addition to improving inter-session anatomic reproducibility. Results thus far suggest that breathing guidance interventions could have implications for improving radiotherapy treatment planning and interfraction reproducibility.

60 APPLIED LIFE SCIENCES↗

SU-E-J-202: Performance of the Patient QA Systems in a Hybrid MRI-Linac

Purpose: The first clinical MR-linac will soon become operational, therefore patient plan QA procedures and equipment have to become MRcompatible. Reference dosimetry is affected by the magnetic field, however, relative dosimetry using patient QA systems haven’t been investigated extensively. The purpose of this study was to examine the performance characteristics of the MR-compatible ArcCHECK and Delta4 systems in a transverse 1.5 T magnetic field. Methods: Recently MR-compatible versions of both ArcCheck (Sun Nuclear) and Delta4 (Scandidos) have been developed. To examine the performance characteristics within the magnetic field, the reproducibility, dose linearity, dose rate dependence, field size and angular dependence were evaluated on the MR-linac (8 MV FFF beam, SAD of 142 cm) and a conventional linac (Elekta, 6MV). To allow comparison of the measurements with and without magnetic field, the measurement setup for the conventional linac is adapted to mimic the setup at the MR-linac if possible (e.g. SAD, dose rate). The results from the MR-linac were benchmarked to the results from the conventional linac as being the clinical reference. Results: At the moment of writing, measurements for the Delta4 are still running. Therefore, only the results of the ArcCheck are presented in this abstract. No significant difference was observed in the reproducibility of the ArcCheck (<0.06%) between both linacs. The maximum dose response difference when measuring the dose linearity was less than 0.4% and the varying dose rate resulted in maximal dose differences of 1.0% for both linacs. Response variation for varying field sizes was <2.6% at the conventional linac, and <1.0% at the MR-linac. Angular response was similar for both linacs. Conclusion: The reproducibility, dose linearity, dose rate dependence, field size and angular dependence of the MR compatible ArcCheck were not influenced by the presence of a transverse 1.5 T magnetic field. The results for the Delta4 are about to follow. Equipment is generously provided by Sun Nuclear Corporation (Melbourne, USA) and Scandidos (Uppsala, Sweden)

60 APPLIED LIFE SCIENCES↗